주거 환기 시스템의 공기 분배 성능 개선 방안 (A Method for Improving Air Distribution Performance at the Residence Ventilation System)

  • 박은준;김용봉;나희형;이상기
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.589-593
    • /
    • 2007
  • In the mechanical ventilation system, it is a fundamental condition to distribute the air equally to the each room. In this study, distribution performance of the air distributor which generally connected to a circular duct was investigated by simulation and experiment. In the first CFD analysis, maximum air flow rate deviation was an 63% in the air distributor model. After numbers of model modification and simulation, maximum flow rate deviation was reduced to 19% in the final simulation model. An air distributor which used in the experiment was produced by using data obtained from the final analysis. When experimental result was compared with analysis result, there was a deviation difference as much as 9%.

  • PDF

유해가스 및 분진이 발생하는 작업장내의 자연환기에 대한 연구 (The Study on Natural Ventilation in Working Places with the Noxious Gas and Dust)

  • 추병길;김철;최종욱;유수열
    • 한국안전학회지
    • /
    • 제15권1호
    • /
    • pp.72-79
    • /
    • 2000
  • In recent, occupational diseases in harmful working places become a social issue. It is the well-known fact that a respiration in polluted working places exert a serious effect on health of workers. Accordingly, the cutting off contaminants air originally is the best way to improve working environments. In these cases, ventilation systems should be essentially installed to dilute or exhaust the contaminated indoor air. In this study, we investigated the characteristics of ventilation system of the noxious gas in working indoor places with natural ventilation by using COMET. The numerical simulations were carried out the natural ventilation with two phase(air, dust). For turbulent flow, Reynolds stresses were closed by the standard $\kappa$-$\varepsilon$ model. The results are as follows ; 1) In the natural exhaust in the working place, the flows of the central region have a more rapid velocity vector than the right and left one. 2) Numerical results show that the distribution of contaminants concentration have greater influence on convection than the case of diffusion by government of velocity vectors. 3) To observe the velocity variation with distance, three location of distance are considered. As results, it shows that the velocity are 0.075(m/s) at y=5(m), 10(m) and mean concentration are raised 10.6% at y=5(m), 10(m). 4) We have presented the useful data for the adequate counterplan in the harmful working places by carrying out the various investigation of the natural ventilation.

  • PDF

철도터널화재용 접이식 대피통로 개발을 위한 양압 조건 도출 (Derivations of Positive Pressure Condition for Development of Foldable Safe Pathway in Railway Tunnel Fires)

  • 김지태;노경철
    • 한국산학기술학회논문지
    • /
    • 제20권1호
    • /
    • pp.284-289
    • /
    • 2019
  • 접이식 대피통로는 철도터널 및 대공간 화재시 임시 피난로를 확보하기 위한 피난지원 시스템으로 화재시 구조물 상부에 거치되어 있던 차연 스크린이 펼쳐지며 피난로를 확보하는 시스템이다. 차연 스크린은 적절한 내화성능을 갖추어야 될 뿐 아니라 밀폐성을 확보하여 외부의 연기를 최대한 막을 수 있는 시스템이 요구된다. 이를 위해 접이식 대피통로 시스템에는 피난로 내부에 양압 조건을 유지해 주기 위한 제연설비가 필요하며, 제연 설비의 설계 및 용량 산정을 위해서는 화원에서 거리별 온도 분포 및 압력 해석이 필요하다. 본 연구에서는 신형전동차의 화재 현상을 모사하여 터널 길이방향별 온도 및 압력 분포를 해석하였다. 차연 스크린 설치 위치에서는 길이방향으로 20미터 이상일 경우에는 차연 스크린 내열온도인 200도를 넘지 않는 것으로 해석되었으며, 압력 또한 거리 증가에 따라 감소하며, 최대 14 Pa, 평균 6 Pa 정도를 보이는 것으로 해석되었다. 또한 상부 보단 하부에서의 압력이 낮기 때문에 실제 양압조건은 이보다 낮을 것으로 보인다. 따라서 접이식 대피통로 설치를 위해서는 차연 스크린내 양압조건을 6 Pa 내외로 유지할 수 있는 제연설비가 필요할 것으로 예측된다.

급성 폐손상 환자에서 Adaptive Support Ventilation 적용 시 호흡지표의 양상 (Evaluation of Respiratory Parameters in Patients with Acute Lung Injury Receiving Adaptive Support Ventilation)

  • 이규성;정우영;정윤정;박주헌;신승수;황성철;박광주
    • Tuberculosis and Respiratory Diseases
    • /
    • 제70권1호
    • /
    • pp.36-42
    • /
    • 2011
  • Background: Adaptive support ventilation (ASV), an automated closed-loop ventilation mode, adapts to the mechanical characteristics of the respiratory system by continuous measurement and adjustment of the respiratory parameters. The adequacy of ASV was evaluated in the patients with acute lung injury (ALI). Methods: A total of 36 patients (19 normal lungs and 17 ALIs) were enrolled. The patients' breathing patterns and respiratory mechanics parameters were recorded under the passive ventilation using the ASV mode. Results: The ALI patients showed lower tidal volumes and higher respiratory rates (RR) compared to patients with normal lungs ($7.1{\pm}0.9$ mL/kg vs. $8.6{\pm}1.3$ mL/kg IBW; $19.7{\pm}4.8$ b/min vs. $14.6{\pm}4.6$ b/min; p<0.05, respectively). The expiratory time constant (RCe) was lower in ALI patients than in those with normal lungs, and the expiratory time/RCe was maintained above 3 in both groups. In all patients, RR was correlated with RCe and peak inspiratory flow ($r_s$=-0.40; $r_s$=0.43; p<0.05, respectively). In ALI patients, significant correlations were found between RR and RCe ($r_s$=-0.76, p<0.01), peak inspiratory flow and RR ($r_s$=-0.53, p<0.05), and RCe and peak inspiratory flow ($r_s$=-0.53, p<0.05). Conclusion: ASV was found to operate adequately according to the respiratory mechanical characteristics in the ALI patients. Discrepancies with the ARDS Network recommendations, such as a somewhat higher tidal volume, have yet to be addressed in further studies.

차량용 에어컨필터 교환시점 알림 시스템 및 과농도 먼지 차단 시스템 (Auto Alarm System of Replacement Period for Vehicle Cabin Filter & Interception System of High Concentration Dust)

  • 이규세;변성욱;김영민;박성우;염영진
    • 대한기계학회논문집A
    • /
    • 제32권11호
    • /
    • pp.1035-1040
    • /
    • 2008
  • Replacement period for vehicle cabin filter of most automobiles is fixed without consideration of conditions of filter and environment. Auto alarm system of replacement period at vehicle cabin filter and interception system of high concentration dust were developed. Control program which is related with the AQS has been developed based on the circuit drive algorithm. This system is expected to be beneficial to passenger's health and to extend the life of the filter which regulates vehicle HVAC system by ventilation mode change at the time of high concentration dust.

국내 2층 돈사와 톱밥돈사의 구조 및 분뇨처리 실태조사 (Field Survey on the Structure and Manure Treatment of Two-Storey and Sawdust Pig Houses in Korea)

  • 정종원;유용희;송준익;김태일;전병수;양창범
    • 한국축산시설환경학회지
    • /
    • 제11권3로
    • /
    • pp.169-176
    • /
    • 2005
  • 본 연구에서는 국내 2층 돈사 및 톱밥돈사를 조사하였으며 현재 양돈에 적용되고 있는 분뇨처리 형태, 사육형태, 환기방식 및 돈사건축비의 실태를 현장조사를 통하여 분석, 평가함으로써 이를 바탕으로 우리나라 기후와 조건에 적합한 분뇨처리와 돼지사육이 가능한 고상식 돈사의 건축모델에 적용 가능성을 고려할 목적으로 무창 2층 돈사와 개방식 톱밥돈사 농장을 방문 조사한 결과를 요약하면 다음과 같다. 1. 2층 돈사의 분뇨에 수분조절재로 톱밥, 수피, 왕겨를 사용하였다. 톱밥돈사는 톱밥만을 사용하였으며, 수분조절재의 사용깊이는 대체로 $30\~60cm$로, 이용기간은 평균 $3\~6$개월 정도 이용하였다. 2. 2층 돈사에서 돼지의 사육형태는 1층에서는 주로 임신돈 및 분만돈을 사육하였고 2층은 자돈과 육성돈을 사육하고 있었다. 3. 환기시스템은 기본적으로 2층 무창돈사는 기계적 환기(mechanical ventilation)시스템을 설치하였고 톱밥돈사는 자연환기(natural ventilation)시스템으로 조합되어 있었다. 4. 2층 돈사의 단열재는 블록, 칼라강판 및 샌드위치 판넬 등을 사용하였고 단열재두께는 지붕 $75\~100mm$, 벽이 $50\~75mm$였으며 천장높이는 최소 2.0, 최대 3.0m로 조사되었다. 5. 평당 건축비는 무창 이층돈사는$70\~1,400$천원 이내였으며, 개방식 톱밥돈사는 자체 건축한 곳을 제외하고는 $300\~400$천원 내외로 건축비가 소요되었다

  • PDF

저심도 도로터널에서 터널과 수직환기구의 단면적 비와 열방출률이 Plug-holing 현상에 미치는 영향에 관한 실험연구 (Experimental Study on the Effect of the Area Ratio between Shaft and Tunnel and Heat Release Rate on the Plug-holing Phenomena in Shallow Underground Tunnels)

  • 홍기배;나준영;유홍선
    • 한국산학기술학회논문지
    • /
    • 제20권4호
    • /
    • pp.619-625
    • /
    • 2019
  • 저심도 터널에서는 온도차에 의한 부력을 이용한 자연배기시스템이 많이 사용되고 있지만 이는 연기배출을 인위적으로 조절할 수 없다. 그러므로 자연배기시스템에서는 수직환기구에서 연기 배출량이 설계된 연기 배출량보다 적어지는 Plug-holing 현상을 고려한 설계가 필수적이다. Plug-holing 현상은 터널과 수직환기구의 형상 위치, 화원의 위치와 발열량 등에 영향을 받는다. 본 연구에서는 터널과 자연 환기구의 단면적 비와 화원의 열방출률이 자연배기시스템에서 발생하는 Plug-holing 현상에 미치는 영향에 대하여 실험적으로 분석하였다. 1/20 크기로 축소시킨 실험모델에서 터널과 수직환기구의 종횡비는 고정시키고 터널과 수직환기구의 단면적 비를 달리하여 Plug-holing 현상에 미치는 영향을 확인하였다. 화원의 열방출율은 0.55 kW, 0.98 kW, 1.67 kW로 고정시켰다. 실험결과, 연기 경계층온도와 수직환기구 내의 온도와의 비교를 통한 Plug-holing 발생을 판단하였고, 터널과 수직환기구의 단면적 비가 증가함에 따라서 수직환기구 하부의 유동과 온도분포 특성이 변함을 확인하였다. 터널 화재 시 Plug-holing 현상은 터널과 수직환기구의 단면적 비에 영향을 받으며 단면적 비가 클수록 Plug-holing 발생 가능성이 증가하였다.