• 제목/요약/키워드: Mechanical Switch

검색결과 205건 처리시간 0.03초

통신기기 냉각용 하이브리드 냉방시스템의 성능특성 (Cooling Performance of a Hybrid Refrigeration System for Telecommunication Equipment)

  • 전종욱;김용찬;최종민
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.489-494
    • /
    • 2006
  • Electronic and telecommunication industries are constantly trying to develop compact components having high power density. Therefore, a proper heat dissipation method is very important to allow reliable operation of the telecommunication equipment. In this study, a hybrid refrigeration system for a telecommunication equipment room was designed to save energy consumption and improve reliability of the compressor In addition, the performance of the hybrid refrigeration system was measured with a variation of outdoor load. The designed hybrid refrigeration system for the telecommunication equipment shelter saved the energy approximately 50%e at the mode switch temperature of $8.3^{\circ}C$.

  • PDF

스냅스루 좌굴을 이용한 미소스위치의 설계, 제작 및 실험 (Design, Fabrication and tTsting of a Microswitch Using Snap-through Buckling Phenomenon)

  • 고정상;조영호;곽병만;박관흠
    • 대한기계학회논문집A
    • /
    • 제20권2호
    • /
    • pp.481-487
    • /
    • 1996
  • A snapping-beam microswitch has been designed, fabricated and tested. From a design analysis, necessary and sufficient conditions for a snap-through switching fouction have been derived for a clamped shallow beam. The necessary condition has resulted in a geometric relation, in which the ratio of beam thickness to initial beam deflection plays a key role in the snapping ability. The sufficient condition for the snapping action has been obtained as a function of the inertia force due to applied acceleration, and the electrostatic force, adjustable by an inter-electrode voltage. For experimental investigations, a set of microbeams of silicon dioxide/$P^+$silicon bimorphs have been fabricated. Geometric size and mechanical behavior of each material film have been measured from on-chip test structures. Estimated and measured characteristics of the fabricated devices are compared.

통신망을 이용한 경량전철용 직류배전반의 정보 전송방식 (An Information Transmission Method of DC Switch Gear for Light Railway Vehicle using Communication Network)

  • 이현두;전용주;김수남;백병산;류승표;서광덕
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.953-955
    • /
    • 2004
  • This paper describes the information transmission method using communication networks between Remote Terminal Unit(RTU) and Protection and Control system(PCU) of the direct current switchgear for Light Railway Vehicle, and also represents the test result, which carried out in the laboratory. In this test, transmission signal waveform, polling time, response time and request/response frame were measured between RTU and PCU. The field test including the measurements of analog signal and status of the digital logic operation of PCU will be conducted in near future.

  • PDF

통신기지국용 하이브리드 냉방기의 성능특성 연구 (Performance Characteristics of a Hybrid Air-Conditioner for Telecommunication Equipment Rooms)

  • 김용찬;최종민;강훈;윤준상;김영배;최광민;이호성
    • 설비공학논문집
    • /
    • 제18권11호
    • /
    • pp.874-880
    • /
    • 2006
  • The power density and heat dissipation rate per unit area of the telecommunication equipment have been increased with the technology development in the footprint of telecommunication hardware. A proper heat dissipation method from the PCB module is very important to allow reliable operation of its electronic component. In this study, a hybrid air-conditioner for the telecommunication equipment room was designed to save energy and obtain system reliability. For high outdoor temperatures, the hybrid system operates in the vapor compression cycle, while, for low outdoor temperatures, the hybrid system works in the secondary fluid cooling cycle with no operation of the compressor. The performance of the hybrid air-conditioner was measured by varying outdoor and indoor temperatures. The hybrid air-conditioner yielded 50% energy saving compared with the conventional refrigeration system when the mode switch temperature was $8.3^{\circ}C$.

170kV급 단로기용 Composite Insulator 제조기술에 관한 연구 (A Study on the manufacturing Composite Insulator for 170kV D/S)

  • 진상용;;이동원;송원표;송희석;조한구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.34-36
    • /
    • 2002
  • The objective of this study is to develop the composite insulator for 170kA disconnecting switch. In this paper, we have investigated the test procedure about each component(FRP tube, flange, shed) through technical standard(IEC 61462) and obtained demand characteristics by mechanical & electrical property test.

  • PDF

Development of the Controlled Switching Device for a Cirrcuit Breaker

  • Kim, Ik-Mo;Kim, Myung-Chan;Choi, Young-Chan;Ryu, Sung-Sic;Kim, Dong-Hyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.558-560
    • /
    • 2004
  • Studies on the controlled switching method have been done to prevent the power system surges which cause the insulation deterioration and electro magnetic compatibility (EMC) problems during closing and opening of a circuit breaker. The controlled switching method controls the closing and tripping time in coincidence with the voltage or current to suppress switching surge. It is used to switch condenser bank, no load transformer, and shunt reactor. In this study, basic concept of the controlled switching is introduced, and also the test is performed to find parameters of the controlled switching in a 24kV vacuum circuit. And then, the control device hardware using TMS320C31 DSP has been designed and manufactured. It has been found that the application of IT technology to a circuit breaker is very effective to depress the switching surge.

  • PDF

Torque Ripple Suppression Method for BLDCM Drive Based on Four-Switch Three-Phase Inverter

  • Pan, Lei;Sun, Hexu;Wang, Beibei;Su, Gang;Wang, Xiuli;Peng, Guili
    • Journal of Power Electronics
    • /
    • 제15권4호
    • /
    • pp.974-986
    • /
    • 2015
  • A novel inverter fault-tolerant control scheme is proposed to drive brushless DC motor. A fault-tolerant inverter and its three fault-tolerant schemes (i.e., phase A fault-tolerant, phase B fault-tolerant, and phase C fault-tolerant) are analyzed. Eight voltage vectors are summarized and a voltage vector selection table is used in the control scheme to improve the midpoint current of the split capacitors. A stator flux observer is proposed. The observer can improve flux estimation, which does not require any speed adaptation mechanism and is immune to speed estimation error. Global stability of the flux observer is guaranteed by the Lyapunov stability analysis. A novel stator resistance estimator is incorporated into the sensorless drive to compensate for the effects of stator resistance variation. DC offset effects are mitigated by introducing an integral component in the observer gains. Finally, a control system based on the control scheme is established. Simulation and experiment results show that the method is correct and feasible.

10W급 MEMS 스위치를 이용한 송수신모듈 소형화 개발 (Miniaturization Development of Transmit/Receive Module using a 10W MEMS switch)

  • 이희민;전병철;이복형
    • 한국정보통신학회논문지
    • /
    • 제20권12호
    • /
    • pp.2417-2424
    • /
    • 2016
  • 항공기용 능동위상배열레이다와 같이 한정된 플랫폼에 장착되는 레이다에 사용하는 부품은 소형/경량화 특성이 매우 중요하다. 또한 최근의 능동위상배열레이다는 목표물의 탐지/추적이 가능한 다목적 레이다로 사용하기 위해 수천 개의 송수신모듈이 안테나의 배열형태로 개발되며, 여기에 적용하기 위한 송수신모듈 크기와 무게는 전체 레이다를 설계하는데 중요한 요소이다. 본 논문에서는 국산화 개발된 10W급 RF MEMS 스위치를 이용하여 소형 송수신 모듈을 개발하였고, 기존에 순환기(Circulator)를 사용한 것보다 회로 면적을 약 86.5% 수준으로 줄였다. 개발된 송수신모듈은 주요 전기적 요구 성능을 만족했을 뿐만 아니라, MIL-STD의 환경시험을 통과하여 군수 부품으로 적합함을 확인하였다. 송수신모듈에 적용된 MEMS 스위치는 적응형 수신기 (Adaptive Tunable Receiver), 재구성 가능한 스마트 능동위상배열안테나(Reconfigurable smart active antenna), 광대역 빔조향 안테나 등에도 적용할 수 있다.

내지진용 리드스위치를 이용한 일체형원자로용 위치지시기 개발 (Development of Control Rod Position Indicator using Seismic-Resistance Reed Switches for Integral Reactor)

  • 유제용;김지호;허형;최명환;손동성
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.593-596
    • /
    • 2008
  • The reed switch position transmitter (RSPT) is used as a position indicator for the control rod in commercial nuclear power plants made by ABB-CE. But this position indicator has some problems when directly adopting it to the integral reactor. The Control Element Drive Mechanism (CEDM) for the integral reactor is designed to raise and lower the control rod in steps of 2mm in order to satisfy the design features of the integral reactor which are the soluble boron free operation and the use of a nuclear heating for the reactor start-up. Therefore the resolution of the position indicator for the integral reactor should be achieved to sense the position of the control rod more precisely than that of the RSPT of the ABB-CE. This paper adopts seismic resistance reed switches to the position indicator in order to reduce the damages or impacts during the handling of the position indicator and earthquake.

  • PDF

면취 공정의 능동 제어를 위한 공압식 자동 강재 면취기와 센서 시스템의 제작 및 실험 (Fabrication and Experiment of Pneumatic Steel Plate Chamfering Machine and Sensor System for Active Control of Chamfering)

  • 나영민;이현석;김민효;박종규
    • 한국기계가공학회지
    • /
    • 제19권12호
    • /
    • pp.80-86
    • /
    • 2020
  • With the exception of welding activities, it is forbidden to use electricity in shipyards, owing to safety concerns such as the possibility of fire, explosions, and short circuits. In this paper, an automatic chamfering machine using pneumatics is proposed for use in such environments. Customers specify their requirements and the machine derives the corresponding theoretical design conditions. The proposed machine was used to perform 3D modeling, and its suitability and performance were confirmed via cutting experiments of the manufactured device. Two types of sensors may be used in this system: contact and non-contact. In the case of the contact type, an end-stop switch that can recognize the end of the material is installed, and when the machine reaches the end of the material, the end-stop switch is operated to cut off the air pressure. In the non-contact type, four sensors were used: photonic, ultrasonic, metal detection, and encoder. The use of the four sensors was repeated 30 times, and the average error determined. Thus, the optimum sensor was identified.