• Title/Summary/Keyword: Mechanical Efficiency

Search Result 4,920, Processing Time 0.028 seconds

Effect of Particle Concentration on Digital Holographic PTV Measurement (입자 농도가 Digital Holographic PTV 측정에 미치는 영향에 관한 연구)

  • Kim Seok;Lee Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.10 s.253
    • /
    • pp.929-934
    • /
    • 2006
  • The digital HPTV(holographic particle tracking velocimetry) velocity field measurement system consists of four steps: recording, numerical reconstruction, particle extraction and velocity extraction. In the velocity extraction process, we improved the two frame PTV algorithm to extract 3-D displacement information of each particle located in 3D space. Because a digital CCD camera was used, some factors such as spatial resolution, numerical aperture, and particle concentration influenced on the performance of the developed digital HPTV. Especially, the particle concentration $(C_o)$ affected the reconstruction efficiency and recovery ratio in the numerical reconstruction and particle extraction procedure. In this paper, the effect of particle concentration reconstruction efficiency and recovery ratio were analyzed experimentally. Optimal particle concentration was found to be in the range of $C_o=11{\sim}17\;particles/mm^3$.

A Study on Improvement of Performance for Perforated Type Total HEX Element (다공형 유로를 적용한 전열교환기 소자의 성능향상에 관한 연구)

  • Kwak, Kyung-Min;Bai, Cheol-Ho;Kim, Jee-Yong;Chu, Euy-Sun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.7
    • /
    • pp.529-536
    • /
    • 2007
  • The perforated type element for a heat recovery ventilation system has been studied to improve the performance. Four holes of diameter of 6mm are punched out for each flow channel to break the boundary layer development and increase the turbulence. KS cooling and heating conditions and test procedures are applied for study. The efficiencies are compared to those of the typical element with smooth surface. For cooling operations, the temperature, latent and enthalpy efficiencies increase 2.5%, 18% and 8%, respectively. For heating operations, the temperature, latent and enthalpy efficiencies increase 3%, 5% and 3.2%, respectively.

Effect of Operating Conditions on Drying Efficiency for Coal Drying Facilities in a Steel Making Plant (제철플랜트용 석탄건조설비에서 운전조건 변경이 건조성능에 미치는 영향)

  • Jeon, Hae-Seak;Moon, Seung-Jae;Yoo, Hoseon
    • Plant Journal
    • /
    • v.5 no.4
    • /
    • pp.73-79
    • /
    • 2009
  • Increase of consumption in limited coal reserves leads prices surging. As a result, iron works which produce products with coal are in difficulties. Accordingly, it is required a lot of research of using non-caking coal that is relatively low cost and has abundant reserves. Direct drying and indirect drying are two major methods of drying the coal. Recently, to minimize the needed calories and to save energy, using fluidbed or fluidizing method is a recent main trend of minimizing the size of the facility and maximizing energy efficiency. However there is also disadvantage such as increasing facility investment because of installing additional facilities in the latter part. In this study, we will have theoretical researches on the indirect drying method with heat exchange system which have been traditionally used. As a result it is expected to increase the efficiency of the facility operation.

  • PDF

Temperature and exhaust gas conversion efficiency of catalytic converters for natural gas vehicles (천연가스자동차 촉매의 온도분포 및 배기정화 특성)

  • Choe, Byeong-Cheol;Kim, Yeong-Gil;Sakai, Takayuki
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.2
    • /
    • pp.205-212
    • /
    • 1998
  • Experiments were conducted to investigate the temperature profile and the emissions conversion efficiency of catalytic converters for natural gas vehicles. Two types of the catalyst structure and several transient engine operating conditions were used. The dual-bed catalyst effectively reduced the emissions in a transient period due to the low heat capacity of the front bed. The lanthanoid additives were effective in improving catalyst durability. When the natural gas fueled engine were operated outside of a very narrow window of excess air ratio (from 0.993 to 1.004), the HC and NOx conversion efficiency dropped off. The drop-off were especially fast on the lean side of the window.

Effects of Inner Jet Injection on Particle Deposition in the Annular Modified Chemical Vapor Deposition Process Using Concentric Tubes (환상형원관을 사용하는 수정된 화학증착(MCVD)방법에서 내부 제트분사가 입자부착에 미치는 영향)

  • 최만수;박경순
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.1
    • /
    • pp.212-222
    • /
    • 1994
  • In the annular Modified Chemical Vapor Deposition process using two concentric tubes, the inner tube is heated to maintain high temperature gradients to have high thermophoretic force which can increase particle deposition efficiency. However, higher axial velocity in a narrow gap between inner and outer tubes can result in a longer tapered entry length. In the present paper, a new concept using an annular jet from the inner tube is presented and shown to significantly reduce the tapered entry length with maintaining high efficiency. Effects of a jet injection on heat transfer, fluid flow and particle deposition have been studied. Of particular interests are the effects of jet velocity, jet location and temperature on the deposition efficiency and tapered length . Torch heating effects from both the previous and present passes are included and the effect of surface radiation between inner and outer tubes is also considered.

A study on the development of the high efficiency condensing heat exchanger (고효율 응축형 열교환기 개발에 관한 연구)

  • Lee, Geum-Bae;Park, Sang-Il;Park, Jun-Tae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.5
    • /
    • pp.589-601
    • /
    • 1997
  • A computer simulation program of a high efficiency condensing heat exchanger is developed. The flue gas flows outside bare tube bundles both in strong cross flow and in weak counter flow and the cooling water inside the tubes. Condensing heat exchangers achieve high efficiency by reducing flue-gas temperatures to a level at which most of the water vapor in the flue gas is condensed and the latent heat associated with phase change of the water is recovered. The computer model has been verified by comparison with measured data. To verify the model, heat transfer coefficient was adjusted, along with the mass transfer diffusion coefficient and pressure drop coefficient, to achieve agreement between predicted and measured data. The efficiencies of heat exchanger increase 2.3 ~ 8.1% by condensations of 6.3 ~ 62.6% of the water vapor in the flue gas.

Comparative studies of gasification potential of agro-waste with wood and their characterization

  • Tripathi, Amarmani;Shukla, S.K.
    • Advances in Energy Research
    • /
    • v.3 no.3
    • /
    • pp.181-194
    • /
    • 2015
  • In this work, an experimental study of the gasification on wood was carried out in downdraft type fixed bed Gasifier attached with 10 kW duel fuel diesel engine. The main objective of the study was to use wood as the biomass fuel for downdraft Gasifier and to evaluate the operating parameter of gasifier unit to predict its performance in terms of gas yield and cold gas efficiency. The influence of different biomass on fuel consumption rate, gas yield and cold gas efficiency was studied. Composition of producer gas was also detected for measuring the lower heating value of producer gas to select the feed stock so that optimum performance in the existing gasifier unit can be achieved. Under the experimental conditions, Lower heating value, of producer gas, cold gas efficiency and gas yields, using wood as a feed stock, are $4.85MJ/m^3$, 46.57% and $0.519m^3/kg$.

Design of the Outlet-Port Tube of a Cyclone-Type Oil Separator for a Compressor (사이클론 방식 유분리기의 출구 튜브 설계)

  • Jang, Seongil;Ahn, Joon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.8
    • /
    • pp.402-408
    • /
    • 2015
  • A series of numerical simulations have been carried out to study the performances of cyclone-type oil separators, which are designed for refrigeration-system compressors. The corresponding working fluid is R22, which is a typical refrigerant, whereby a mineral-oil droplet is supplied (Ed-highlight-My interpretation). The outlet-tube length in relation to the total chamber volume is considered a design parameter. Depending on the tube length, the separation efficiency varies from 98.7% to 99.3%, while the predicted pressure drop is between 5.1 kPa and 6.4 kPa. Considering both the pressure drop and separation efficiency, the length of the outlet-port tube of the separator is 152 mm.

Evaluation of Particle Removal Efficiency during Jet Spray and Megasonic Cleaning for Aluminum Coated Wafers

  • Choi, Hoomi;Min, Jaewon;Kulkarni, Atul;Ahn, Youngki;Kim, Taesung
    • Journal of the Semiconductor & Display Technology
    • /
    • v.11 no.3
    • /
    • pp.7-11
    • /
    • 2012
  • Among various wet cleaning methods, megasonic and jet spray gained their popularity in single wafer cleaning process for the efficient removal of particulate contaminants from the wafer surface. In the present study, we evaluated these two cleaning methods for particle removal efficiency (PRE) and pattern damage on the aluminum layered wafer surface. Also the effect of $CO_2$ dissolved water in jet spray cleaning is assessed by measuring PRE. It is observed that the jet spray cleaning process is more effective in terms of PRE and pattern damage compared to megasonic cleaning and the mixing of $CO_2$ in the water during jet sprays further increases the PRE. We believe that the outcome of the present study is useful for the semiconductor cleaning process engineers and researchers.

Comparative Thermodynamic Analysis of Organic Rankine Cycle and Ammonia-Water Rankine Cycle (유기랭킨사이클과 암모니아-물 랭킨사이클의 열역학적 성능의 비교 해석)

  • KIM, KYOUNG HOON;KIM, MAN-HOE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.5
    • /
    • pp.597-603
    • /
    • 2016
  • In this paper a comparative thermodynamics analysis is carried out for organic Rankine cycle (ORC) and ammonia-water Rankine cycle (AWRC) utilizing low-grade heat sources. Effects of the working fluid, ammonia concentration, and turbine inlet pressure are systematically investigated on the system performance such as mass flow rate, pressure ratio, turbine-exit volume flow, and net power production as well as the thermal efficiency. Results show that ORC with a proper working fluid shows higher thermal efficiency than AWRC, however, AWRC shows lower mass flow rate of working fluid and lower pressure ratio of expander than ORC.