• 제목/요약/키워드: Measuring sensor

검색결과 1,960건 처리시간 0.033초

PMFBG 센서를 이용한 횡방향 변형률 측정 (Measurement of Transverse Strain Using PMBG Sensor)

  • 윤혁진;김대현;홍창선;김천곤
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2002년도 춘계학술발표대회 논문집
    • /
    • pp.27-30
    • /
    • 2002
  • PMFBG sensor was fabricated using phase mask and Excimer laser. The reflected wavelength of PMFBG sensor had dual peaks due to intrinsic birefringence. To discover the polarization axes, peak sensitivity was measured under compression test. The signal characteristics of PMFBG sensor were also examined in embedding condition. The embedded PMFBG sensor in epoxy block was loaded for the transverse strain measurements. Experiments showed that the PMFBG sensor could successfully measure the transverse strain. This PMFBG sensor is useful for the structures that require measuring transverse stram.

  • PDF

멀티센서 시스템을 이용한 3차원 형상의 기상측정에 관한 연구 (A Study on the 3-dimensional feature measurement system for OMM using multiple-sensors)

  • 권양훈;윤길상;조명우
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 추계학술대회 논문집
    • /
    • pp.158-163
    • /
    • 2002
  • This paper presents a multiple sensor system for rapid and high-precision coordinate data acquisition in the OMM (On-machine measurement) process. In this research, three sensors (touch probe, laser, and vision sensor) are integrated to obtain more accurate measuring results. The touch-type probe has high accuracy, but is time-consuming. Vision sensor can acquire many point data rapidly over a spatial range but its accuracy is less than other sensors. Also, it is not possible to acquire data for invisible areas. Laser sensor has medium accuracy and measuring speed among the sensors, and can acquire data for sharp or rounded edge and the features with very small holes and/or grooves. However, it has range- constraints to use because of its system structure. In this research, a new optimum sensor integration method for OMM is proposed by integrating the multiple-sensor to accomplish mote effective inspection planning. To verify the effectiveness of the proposed method, simulation and experimental works are performed, and the results are analyzed.

  • PDF

루우프형 센서를 이용한 자장측정계 (Magnetic Field Measuring System by using Loop-type Sensor)

  • 이복희;길경석;박동화
    • 센서학회지
    • /
    • 제4권2호
    • /
    • pp.14-21
    • /
    • 1995
  • 본 논문은 전력설비와 뇌방전에 의하여 발생하는 시변자장을 측정할 수 있는 능동성 자장측정계에 대하여 기술하였다. 자장측정계는 루우프형 센서, 차동증폭기로 동작되는 능동성 적분기로 이루어졌다. 시변자장측정계와 교정장치의 이론적 원리 및 설계방법에 대하여 제시하였으며, 교정실험으로부터 주파수대역 $270\;Hz\;{\sim}\;2.3\;MHz$, 응답감도 128 $mV/{\mu}T$를 얻었고, 교정실험계에서 자장센서범위의 자계의 세기는 ${\pm}3\;%$이내로 균일하였다. 적용실험으로는 대전류 발생장치에 의하여 모의 뇌임펄스전류와 진동성 임펄스전류를 발생시켜서 인가전류와 검출자장의 파형을 비교하였으며, 이의 결과는 거의 일치하였고, 편차는 0.5 %이내이었다.

  • PDF

손목 피부 온도에 의한 맥센서 어레이(array)의 신호 변동 및 보정 (Signal Change and Compensation of Pulse Pressure Sensor Array Due to Wrist Surface Temperature)

  • 전민호;전영주;김영민
    • 센서학회지
    • /
    • 제26권2호
    • /
    • pp.141-147
    • /
    • 2017
  • A pressure sensor in pulse measurement system is a core component for precisely measuring the pulse waveform of radial artery. A pulse sensor signal that measures the pulse wave in contact with the skin is affected by the temperature difference between the ambient temperature and skin surface. In this study, we found experimentally that the signal changes of the pressure sensors and a temperature sensor were caused by the temperature of the wrist surface while the pressure sensor was contacted on the skin surface for measuring pulse wave. To observe the signal change of the pulse sensor caused by temperature increase on sensor surface, Peltier device that can be kept at a set temperature was used. As the temperature of Peltier device was kept at $35^{\circ}C$ (the maximum wrist temperature), the device was put on the pulse sensor surface. The temperature and pressure signals were obtained simultaneously from a temperature sensor and six pressure sensors embedded in the pulse sensor. As a result of signal analysis, the sensor pressure was decreased during temperature increase of pulse sensor surface. In addition, the signal difference ratio of pressure and temperature sensors with respect to thickness of cover layer in pulse sensor was increased exponentially. Therefore, the signal of pressure sensor was modified by the compensation equation derived by the temperature sensor signal. We suggested that the thickness of cover layer in pulse sensor should be designed considering the skin surface temperature.

커프 압력 조절에 따른 혈류량 변화 평가를 위한 임피던스법의 구현 (Implementation of Impedance Method to Estimate Blood Flow Variation with Cuff Pressure Change)

  • 정도운;배진우;손정만;예수영;최병철;남기곤;김철한;전계록
    • 센서학회지
    • /
    • 제13권6호
    • /
    • pp.462-472
    • /
    • 2004
  • In this study, we measured the blood flow on arm by non-invasive method and implemented a system to measure variation of the blood flow by estimating bio-electrical impedance and arterial pressure according to cuff pressure. The implemented system measured impedance variation according to pressure variation applied by artificial cuff pressure on the measuring position. The system consisted of pressure measuring part and impedance measuring part using 4-electrode method. Pressure measuring part was composed of semiconductor pressure sensor and electronic circuit for signal processing of sensor output signal. In addition, impedance measuring part was composed of constant current source circuit and lock-in amplifier for detecting impedance signal. We conducted experiments of impedance measuring part using standard resistance for performance evaluation of the implemented system. In addition we experimented to estimate variation of the blood flow by measuring impedances of the experimental group. We estimated ratio of the blood flow resistance using mean arterial pressure and variation of the blood flow. As a result the ratio of the blood flow resistance and variation of blood flow were in an inverse relationship with each other and the correlation coefficient was -0.96776.

Bluetooth를 이용한 지자기센서의 특성에 관한 연구 (A Study on Characteristics of an Terrestrial Magnetism Sensor with Bluetooth)

  • 박선진;정중수
    • 융합보안논문지
    • /
    • 제6권3호
    • /
    • pp.37-47
    • /
    • 2006
  • 본 논문에서는 필립스사의 지자기센서를 블루투스 통신시스템에 연결하여 방위각을 $5^{\circ}$ 단위로 전후 방향으로 기울기 각도를 변화시켜 $360^{\circ}$를 측정하였다. 측정된 방위값은 100M 이내에서 이동하면서 측정값을 블루투스 통신시스템으로 전송하여 측정값을 분석하였다. 블루투스를 이용하여 전파 장애가 없는 평지에서 직선거리 100M 이내에서 방위 측정값은 에러 없이 전송할 수 있었다. 지자기센서를 수평을 유지하면 98%의 신뢰를 가지는 방위측정값을 얻었다. 본 연구를 바탕으로 기울기를 가지는 지형을 이동하는 이동형 지능로봇에 장착 정확도가 향상된 방위 측정값을 전송하여 이동형 로봇의 방위추적을 할 수 있다.

  • PDF

포켈스센서를 이용한 코로나방전 발생시의 전계변화 측정에 관한 연구 (A possible non-contact measuring technique for the variation of the electric field due to corona discharge by use of Pockels sensor)

  • 마지훈;강원종;임윤석;최재옥;장용무;구자윤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.189-192
    • /
    • 2001
  • In this paper, an novel optical measuring system based on the electro-optic effect has been proposed and realized using Pockels cell with a view to detecting partial discharge taking place at the needle plane electrode. This system has the following advantages ; nonmetallic probe sensor, immune to external EMI noise and broad band response of the Pockels cell from DC to GHz. This system is constructed by He-Ne laser, Mach-Zehnder interferometer with Pockels sensor, balanced photo receiver, data acquisition board and PC. The response characteristics of the developed proto type sensor are examined for AC and corona discharge.

  • PDF

VHF 센서를 이용한 GIS에서 부분방전 측정 기법 (Partial Discharge Measuring Technique in GIS using VHF Sensors)

  • 김정태;김동욱;이영조;구자윤;김지홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.2063-2064
    • /
    • 2011
  • UHF PD sensor has some disadvantages in measuring void discharges due to their frequency characteristics lower than 300MHz. Therefore, in this study, the possibility of VHF sensor in measuring partial discharges(PD) in GIS was investigated using simulated experiments. As a result, by installing VHF sensors to the copper bus of the encloser in GIS, it is confirmed that partial discharges could be perfectly detected, which means that VHF PD measuring technique can be the alternative of UHF PD method.

  • PDF

힘 센서를 이용한 CMM용 프로브 개발을 위한 연구 (A Study on the Development of the CMM Probe using Force-Sensor)

  • 송광석;권기환;박재준;조남규
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.411-415
    • /
    • 2002
  • In this paper, a mechanical probe for CMM (Coordinate Measuring Machine) with a three-axis force-sensing unit is proposed, which is capable of measuring an actual contact position without the lobbing effect and the pre-travel error. The force-sensing unit detects the external force, which is act on the stylus of CMM during the measuring process. Thus, the contact point of the stylus of CMM can be estimated ken the direction of measured force components. Based on the structural analysis of the proposed CMM probe, the transformation matrix is derived and calibrated so that it shows linear relationships between the estimated force components from the output voltages and the real input forces. And, the relationships are verified through the computer simulation. The results show that the proposed mechanical probe is very useful fur detecting the contacting force components on measuring process of CMM.

  • PDF

유비쿼터스 헬스케어를 위한 센서 네트워크 기반의 심전도 및 체온 측정 시스템: 1. 센서 네트워크 플랫폼 구축 (A study on WSN based ECG and body temperature measuring system for ubiquitous healthcare: 1. the construction of sensor network platform)

  • 이영동;정완영
    • 센서학회지
    • /
    • 제15권5호
    • /
    • pp.362-370
    • /
    • 2006
  • The wireless sensor network (WSN) based ECG and body temperature measuring system for ubiquitous health-care were designed and developed. The system was composed of a wireless sensor network node, base station and server computer for the continuous monitoring of ECG signals and body temperatures of patients at home or hospital. ECG signal and body temperature data, important vital signals which are commonly used in clinical and trauma care, were displayed on a graphical user interface (GUI). The data transfer from sensor nodes on patients' body to server computer was accomplished through a base-station connected to a server computer using Zigbee compatible IEEE802.15.4 standard wireless communication. Real-time as well as historical, ECG data of elderly persons or patients, can also be retrieved and played back to assist the diagnosis. The ubiquitous health care system presented in this study can effectively reduce social medical expenses, which will be increased greatly in the coming aging society.