• Title/Summary/Keyword: Measuring parameters

Search Result 1,230, Processing Time 0.039 seconds

The Effect of Temperature and Concentration of Setting Solution on the Rheological Properties of Injectable Calcium Phosphate (경화액의 농도와 온도가 인산칼슘시멘트의 유변학적 성질에 미치는 영향에 관한 연구)

  • Yoo, Hyun-Mi;Chang, Seok-Woo;Park, Dong-Sung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.1
    • /
    • pp.73-82
    • /
    • 2009
  • Injectable calcium phosphate cement (CPC) has been used as bone substitute successfully due to good biocompatibility and osteoconductivity. One of the important mechanical characteristics of CPC is flowablility, which can be evaluated by measuring rheological parameters. However, there have been few studies that measured rheological properties of CPC. The purpose of this study was to evaluate the effects of temperature and concentrations of 2 kinds of setting solutions, hydroxyprophyl methylcellulose (HPMC) and polyacrylic acid (PAA), on rheological properties of CPC. The CPC used was dicalcium phosphate dihydrate (DCPD). Rheological properties of CPC paste were measured using rheometer. The effect of concentrations of each solution (2% and 1% HPMC and 35% and 17.5% PAA) was evaluated. The effect of temperature ($25^{\circ}C$ and $37^{\circ}C$) on the rheological properties of CPC was also investigated. The statistical analysis was carried out with Mann-whitney test with Bonferronis collection. CPC with both setting solutions showed shear thinning behavior. Higher concentrations of setting solution (2% HPMC and 35% PAA) produced significantly higher viscosity than lower concentrations of setting solution (1% HPMC and 17.5% PAA). CPC with HPMC showed significantly higher viscosity at $37^{\circ}C$ that at $25^{\circ}C$. CPC with PAA showed lower viscosity at $37^{\circ}C$ than at $25^{\circ}C$, although the difference was not statistically significant. The results showed that CPC with HPMC or PAA solutions are pseudoplastic and the concentrations of setting solutions and temperature may have an effect on the rheological properties of CPC paste. These results showed that the flowability of injectable CPC could be improved by use of increasing frequency of oscillation. In clinical practice, the use of ultrasonic vibration would be helpful in application of injectable CPC. CPC with HPMC could be more easily applicated at $25^{\circ}C$ than $37^{\circ}C$. The use of lower concentrations of HPMC and PAA solution would be beneficial in terms of flowability.

Antioxidant activity of Bamboo powder and its immunoreactivity in the pig (대나무 분말의 항산화력과 돼지의 면역 활성에 미치는 영향)

  • Song, Yuno;Chu, Gyo-Moon;Jang, Sun-Hee;Goo, Ae-Jin;Ko, Yeoung-Gyu;Ha, Ji Hee;Lee, Jae-Young;Kang, Suk-Nam;Song, Young-Min;Cho, Jae-Hyeon
    • Korean Journal of Veterinary Service
    • /
    • v.37 no.2
    • /
    • pp.111-122
    • /
    • 2014
  • The present study was designed to explore the antioxidant effect of Bamboo powder and its immunoreactivity in pigs. We investigated the functional properties of Bamboo extracts by means of measuring the contents of total polyphenols and flavonoid as well as determining ABST, DPPH radical scavenging activity, and hydroxyl radical scavenging activity and anticancer activity. The total phenolic compound and flavonoids contents of Bamboo extracts were 171.25 mg/g and 127.5 mg/g, respectively. The DPPH radical, hydroxyl radical, ABST radical scavenging activity of Bamboo extracts were 17.3%, 12.5% and 21.5%, respectively. Evidenced by MTT and cell cycle assay, Bamboo dose-dependently inhibited the cell proliferation and induced G0/G1-phase arrest in CHO cells at concentrations of 100, 250, and 500 ${\mu}g/ml$ Bamboo extracts. More than 80% of apoptotic cells were observed by staining with annexin V in 500 ${\mu}g/ml$ Bamboo-treated CHO cells, indicating that Bamboo had potent anticancer activities. Next, to investigate the effect of Bamboo on cytokine, immunoglobulin concentration, and blood compositions, flatting pigs were fed with Bamboo powder for 38 days. Flatting pigs were divided into 4 groups; basal diet (control), basal diet supplemented with 1% Bamboo powder (T1), 2% Bamboo powder (T2), and 3% Bamboo powder (T3). The level of hemoglobin increased in the all Bamboo-fed groups compared with the normal control group. In particular, platelet levels in the all Bamboo-treated groups increased by approximately 90% compared with the levels from pig on a normal control. Serum levels of immunoglobulins (IgG, IgA) in the pigs fed Bamboo powder were modestly increased, and the interferon-${\gamma}$ level also was strongly increased in 2% or 3% Bamboo-fed groups compared with the levels in control groups. Together, these results demonstrated that Bamboo extracts had an effective capacity of scavenging for ABTS, DPPH, and hydroxyl radicals and showed correlation with potent phenol and flavonoid contents, thus suggesting its antioxidant potential. Moreover, administration of Bamboo in 2~3% improved blood parameters and platelets, and especially immunity-related ones such as IgG, IgA, and interferon-${\gamma}$, leading to be potential feed additives in flatting pigs.

A Feasibility Study on the Use of Liner and Cover Materials Using Sewage Sludge (하수슬러지의 차수재 및 복토재로의 이용타당성에 관한 연구)

  • 유남재;김영길;박병수;정하익
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.2
    • /
    • pp.43-71
    • /
    • 1999
  • This research is an experimental work of developing a construction material using municipal wastewater sludge as liner and cover materials for waste disposal landfill. Weathered granite soil and flyash, produced as a by-product in the power plant, were used as the primary additives to improve geotechnical engineering properties of sludge. For secondary additives, bentonite and cement were mixed with sludge to decrease the permeability and to increase the shear strength, respectively. Various laboratory test required to evaluate the design criteria for liner and cover materials, were carried out by changing the mixing ratio of sludge with the additives. Basic soil properties such as specific gravity, grain size distribution, liquid and plastic limits were measured to analyze their effects on permeability, compaction, compressibility and shear strength properties of mixtures. Laboratory compaction tests were conducted to find the maximum dry densities and the optimum moisture contents of mixtures, and their effectiveness of compaction in field was consequently evaluated. Permeability tests of variable heads with compacted samples, and the stress-controlled consolidation tests with measuring permeabilities of samples during consolidation process were performed to obtain permeability, and to find the compressibility as well as consolidational coefficients of mixtures, respectively. To evaluate the long term stability of sludges, creep tests were also conducted in parallel with permeability tests of variable heads. On the other hand, for the compacted sludge decomposed for a month, permeability tests were carried out to investigate the effect of decomposition of organic matters in sludges on its permeability. Direct shear tests were performed to evaluate the shear strength parameters of mixed sludge with weathered granite, flyash and bentonite. For the mixture of sludge with cement, unconfined compression tests were carried out to find their strength with varying mixing ratio and curing time. On the other hand, CBR tests for compacted specimen were also conducted to evaluate the trafficability of mixtures. Various test results with mixtures were assessed to evaluate whether their properties meet the requirements as liner and cover materials in waste disposal landfill.

  • PDF

Effect of Pulse Energy and Pulse Repetition Rate at the Identical Total Power During Enamel Ablation Using an Er:YAG Laser (Er:YAG 레이저를 이용한 치아 삭제시 동일출력에서 펄스에너지와 조사반복률의 영향)

  • Won, Jung-Yeon;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.31 no.3
    • /
    • pp.223-229
    • /
    • 2006
  • The objectives of this study was to investigate the amount of tooth ablation and the change of intrapulpal temperature by Er:YAG laser as it relates to pulse energy and pulse repetition rate at the identical power and, thereby, to reveal which of the two parameters strongly relates with ablation efficiency and intrapulpal temperature. Extracted healthy human molar teeth were sectioned into two pieces and each specimen was irradiated within the combination of pulse energy and pulse repetition time at the same power of 3W; $300mJy{\times}10Hz$ group, $200mJy{\times}15Hz$ group, and $150mJy{\times}20Hz$ group. Each specimen comprised ten tooth specimens. A laser beam with conjunction of a water flow rate of 1.6 ml/min was applied over enamel surfaces of the specimens during 3 seconds and the ablation amount was determined by difference in weight before and after irradiation. To investigate the temperature change in the pulp according to the above groups, another five extracted healthy human molar teeth were prepared. Each tooth was embedded into resin block and the temperature-measuring probes were kept on the irradiated and the opposite walls in the dental pulp during lasing. When the power was kept constant at 3W, ablation amount increased with pulse energy rather than pulse repetition rate (p=0.000). Although intrapulpal temperature increased with pulse repetition rate, there were no significant differences among the groups and between the irradiated and the opposite pulpal walls, except at a condition of $150y{\times}20Hz$ (p=0.033). Conclusively, it is suggested that ablation efficacy is influenced by pulse energy rather than pulse repetition rate.

A Comparative Study on Quantifying Uncertainty of Vitamin A Determination in Infant Formula by HPLC (HPLC에 의한 조제분유 중 비타민 A 함량 분석의 측정불확도 비교산정)

  • Lee, Hong-Min;Kwak, Byung-Man;Ahn, Jang-Hyuk;Jeon, Tae-Hong
    • Korean Journal of Food Science and Technology
    • /
    • v.40 no.2
    • /
    • pp.152-159
    • /
    • 2008
  • The purpose of this study was to determine the accurate quantification of vitamin A in infant formula by comparing two different standard stock solutions as well as various sample weights using high performance liquid chromatography. The sources of uncertainty in measurement, such as sample weight, final smaple vloume, and the instrumental results, were identified and used as parameters to determine the combined standard uncertainty based on GUM(guide to the expression of uncertainty in measurement) and the Draft EURACHEM/CITAC Guide. The uncertainty components in measuring were identified as standard weight, purity, molecular weight, dilution of the standard solution, calibration curve, recovery, reproducibility, sample weight, and final sample volume. Each uncertainty component was evaluated for type A and type B and included to calculate the combined uncertainty. The analytical results and combined standard uncertainties of vitamin A according to the two different methods of stock solution preparation were 627 ${\pm}$ 33 ${\mu}$g R.E./100 g for 1,000 mg/L of stock solution, and 627 ${\pm}$ 49 ${\mu}$g R.E./100 g for 100 mg/L of stock solution. The analytical results and combined standard uncertainties of vitamin A according to the various sample weighs were 622 ${\pm}$ 48 ${\mu}$g R.E./100 g, 627 ${\pm}$ 33 ${\mu}$g R.E./100 g, and 491 ${\pm}$ 23 ${\mu}$g R.E./100 g for 1 g, 2 g, and 5 g of sampling, respectively. These data indicate that the preparation method of standard stock solution and the smaple amount were main sources of uncertainty in the analysis results for vitamin A. Preparing 1,000 mg/L of stock solution for standard material sampling rather than 100 mg, and sampling not more than 2 g of infant formula, would be effective for reducing differences in the results as well as uncertainty.

Effect of the Configuration of Contact Type Textile Electrode on the Performance of Heart Activity Signal Acquisition for Smart Healthcare (스마트 헬스케어를 위한 심장활동 신호 검출용 접촉식 직물전극의 구조가 센싱 성능에 미치는 영향)

  • Cho, Hyun-Seung;Koo, Hye-Ran;Yang, Jin-Hee;Lee, Kang-Hwi;Kim, Sang-Min;Lee, Jeong-Hwan;Kwak, Hwy-Kuen;Ko, Yun-Su;Oh, Yun-Jung;Park, Su-Youn;Kim, Sin-Hye;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.21 no.4
    • /
    • pp.63-76
    • /
    • 2018
  • The purpose of this study was to investigate the effect of contact type textile electrode structure on heart activity signal acquisition for smart healthcare. In this study, we devised six contact type textile electrodes whose electrode size and configuration were manipulated for measuring heart activity signals using computerized embroidery. We detected heart activity signals using a modified lead II and by attaching each textile electrode to the chest band in four healthy male subjects in a standing static posture. We measured the signals four times repeatedly for all types of electrodes. The heart activity signals were sampled at 1 kHz using a BIOPAC ECG100, and the detected original signals were filtered through a band-pass filter. To compare the performance of heart activity signal acquisition among the different structures of the textile electrodes, we conducted a qualitative analysis using signal waveform and size as parameters. In addition, we performed a quantitative analysis by calculating signal power ratio (SPR) of the heart activity signals obtained through each electrode. We analyzed differences in the performance of heart activity signal acquisition of the six electrodes by performing difference and post-hoc tests using nonparametric statistic methods on the calculated SPR. The results showed a significant difference both in terms of qualitative and quantitative aspects of heart activity signals among the tested contact type textile electrodes. Regarding the configurations of the contact type textile electrodes, the three-dimensionally inflated electrode (3DIE) was found to obtain better quality signals than the flat electrode. However, regarding the electrode size, no significant difference was found in performance of heart signal acquisition for the three electrode sizes. These results suggest that the configuration method (flat/3DIE), which is one of the two requirements of a contact type textile electrode structure for heart activity signal acquisition, has a critical effect on the performance of heart activity signal acquisition for wearable healthcare. Based on the results of this study, we plan to develop a smart clothing technology that can monitor high-quality heart activity without time and space constraints by implementing a clothing platform integrated with the textile electrode and developing a performance improvement plan.

Effects of Elevated Temperature after the Booting Stage on Physiological Characteristics and Grain Development in Wheat (밀에서 출수 후 잎의 생리적 특성 및 종실 생장에 대한 수잉기 이후 고온의 효과)

  • Song, Ki Eun;Choi, Jae Eun;Jung, Jae Gyeong;Ko, Jong Han;Lee, Kyung Do;Shim, Sang-In
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.66 no.4
    • /
    • pp.307-317
    • /
    • 2021
  • In recent years, global warming has led to frequent climate change-related problems, and elevated temperatures, among adverse climatic factors, represent a critical problem negatively affecting crop growth and yield. In this context, the present study examined the physiological traits of wheat plants grown under high temperatures. Specifically, the effects of elevated temperatures on seed development after heading were evaluated, and the vegetation indices of different organs were assessed using hyperspectral analysis. Among physiological traits, leaf greenness and OJIP parameters were higher in the high-temperature treatment than in the control treatment. Similarly, the leaf photosynthetic rate during seed development was higher in the high-temperature treatment than in the control treatment. Moreover, temperature by organ was higher in the high-temperature treatment than in the control treatment; consequently, the leaf transpiration rate and stomatal conductance were higher in the control treatment than in the high-temperature treatment. On all measuring dates, the weight of spikes and seeds corresponding to the sink organs was greater in the high-temperature treatment than in the control treatment. Additionally, the seed growth rate was higher in the high-temperature treatment than in the control treatment 14 days after heading, which may be attributed to the higher redistribution of photosynthates at the early stage of seed development in the former. In hyperspectral analysis, the vegetation indices related to leaf chlorophyll content and nitrogen state were higher in the high-temperature treatment than in the control treatment after heading. Our results suggest that elevated temperatures after the booting stage positively affect wheat growth and yield.

Evaluation of waterlogging tolerance using chlorophyll fluorescence reaction in the seedlings of Korean ginseng (Panax ginseng C. A. Meyer) accessions (엽록소 형광반응을 이용한 인삼 유전자원의 습해 스트레스 평가)

  • Jee, Moo Geun;Hong, Young Ki;Kim, Sun Ick;Park, Yong Chan;Lee, Ka Soon;Jang, Won Suk;Kwon, A Reum;Seong, Bong Jae;Kim, Me-Sun;Cho, Yong-Gu
    • Journal of Plant Biotechnology
    • /
    • v.49 no.3
    • /
    • pp.240-249
    • /
    • 2022
  • Measuring chlorophyll fluorescence (CF) is a useful tool for assessing a plant's ability to tolerate abiotic stresses such as drought, waterlogging and high temperature. Korean ginseng is highly sensitive to water stress in paddy fields. To evaluate the possibility of non-destructively diagnosing waterlogging stress using chlorophyll fluorescence (CF) imaging techniques, we screened 57 ginseng accessions for waterlogging tolerance. To evaluate waterlogging tolerance among the 2-year-old Korean ginseng accessions, we treated ginseng plants with water stress for 25 days. The physiological disorder rate was characterized through visual assessment (an assigned score of 0-5). The physiological disorder rates of Geumjin, Geumsun and GS00-58 were lower than that of other accessions. In contrast, lines GS97-62, GS97-69 and GS98-1-5 were deemed susceptible. Root traits, chlorophyll content and the reduction rates decreased in most ginseng accessions. Further, these metrics were significantly lower in susceptible genotypes compared to resistant ones. All CF parameters showed a positive or negative response to waterlogging stress, and this response continuously increased over the treatment time among the genotypes. The CF parameter Fv/Fm was used to screen the 57 accessions, and the results showed clear differences in Fv/Fm between the susceptible and resistant genotypes. Susceptible genotypes had an especially low Fv/Fm value of less than 0.8, reflecting damage to the reaction center of photosystem II. It is concluded that Fv/Fm can be used as a CF parameter index for screening waterlogging stress tolerance in ginseng genotypes.

The Accuracy Evaluation of Digital Elevation Models for Forest Areas Produced Under Different Filtering Conditions of Airborne LiDAR Raw Data (항공 LiDAR 원자료 필터링 조건에 따른 산림지역 수치표고모형 정확도 평가)

  • Cho, Seungwan;Choi, Hyung Tae;Park, Joowon
    • Journal of agriculture & life science
    • /
    • v.50 no.3
    • /
    • pp.1-11
    • /
    • 2016
  • With increasing interest, there have been studies on LiDAR(Light Detection And Ranging)-based DEM(Digital Elevation Model) to acquire three dimensional topographic information. For producing LiDAR DEM with better accuracy, Filtering process is crucial, where only surface reflected LiDAR points are left to construct DEM while non-surface reflected LiDAR points need to be removed from the raw LiDAR data. In particular, the changes of input values for filtering algorithm-constructing parameters are supposed to produce different products. Therefore, this study is aimed to contribute to better understanding the effects of the changes of the levels of GroundFilter Algrothm's Mean parameter(GFmn) embedded in FUSION software on the accuracy of the LiDAR DEM products, using LiDAR data collected for Hwacheon, Yangju, Gyeongsan and Jangheung watershed experimental area. The effect of GFmn level changes on the products' accuracy is estimated by measuring and comparing the residuals between the elevations at the same locations of a field and different GFmn level-produced LiDAR DEM sample points. In order to test whether there are any differences among the five GFmn levels; 1, 3, 5, 7 and 9, One-way ANOVA is conducted. In result of One-way ANOVA test, it is found that the change in GFmn level significantly affects the accuracy (F-value: 4.915, p<0.01). After finding significance of the GFmn level effect, Tukey HSD test is also conducted as a Post hoc test for grouping levels by the significant differences. In result, GFmn levels are divided into two subsets ('7, 5, 9, 3' vs. '1'). From the observation of the residuals of each individual level, it is possible to say that LiDAR DEM is generated most accurately when GFmn is given as 7. Through this study, the most desirable parameter value can be suggested to produce filtered LiDAR DEM data which can provide the most accurate elevation information.

Measuring Consumer-Brand Relationship Quality (소비자-브랜드 관계 품질 측정에 관한 연구)

  • Kang, Myung-Soo;Kim, Byoung-Jai;Shin, Jong-Chil
    • Journal of Global Scholars of Marketing Science
    • /
    • v.17 no.2
    • /
    • pp.111-131
    • /
    • 2007
  • As a brand becomes a core asset in creating a corporation's value, brand marketing has become one of core strategies that corporations pursue. Recently, for customer relationship management, possession and consumption of goods were centered on brand for the management. Thus, management related to this matter was developed. The main reason of the increased interest on the relationship between the brand and the consumer is due to acquisition of individual consumers and development of relationship with those consumers. Along with the development of relationship, a corporation is able to establish long-term relationships. This has become a competitive advantage for the corporation. All of these processes became the strategic assets of corporations. The importance and the increase of interest of a brand have also become a big issue academically. Brand equity, brand extension, brand identity, brand relationship, and brand community are the results derived from the interest of a brand. More specifically, in marketing, the study of brands has been led to the study of factors related to building of powerful brands and the process of building the brand. Recently, studies concentrated primarily on the consumer-brand relationship. The reason is that brand loyalty can not explain the dynamic quality aspects of loyalty, the consumer-brand relationship building process, and especially interactions between the brands and the consumers. In the studies of consumer-brand relationship, a brand is not just limited to possession or consumption objectives, but rather conceptualized as partners. Most of the studies from the past concentrated on the results of qualitative analysis of consumer-brand relationship to show the depth and width of the performance of consumer-brand relationship. Studies in Korea have been the same. Recently, studies of consumer-brand relationship started to concentrate on quantitative analysis rather than qualitative analysis or even go further with quantitative analysis to show effecting factors of consumer-brand relationship. Studies of new quantitative approaches show the possibilities of using the results as a new concept of viewing consumer-brand relationship and possibilities of applying these new concepts on marketing. Studies of consumer-brand relationship with quantitative approach already exist, but none of them include sub-dimensions of consumer-brand relationship, which presents theoretical proofs for measurement. In other words, most studies add up or average out the sub-dimensions of consumer-brand relationship. However, to do these kind of studies, precondition of sub-dimensions being in identical constructs is necessary. Therefore, most of the studies from the past do not meet conditions of sub-dimensions being as one dimension construct. From this, we question the validity of past studies and their limits. The main purpose of this paper is to overcome the limits shown from the past studies by practical use of previous studies on sub-dimensions in a one-dimensional construct (Naver & Slater, 1990; Cronin & Taylor, 1992; Chang & Chen, 1998). In this study, two arbitrary groups were classified to evaluate reliability of the measurements and reliability analyses were pursued on each group. For convergent validity, correlations, Cronbach's, one-factor solution exploratory analysis were used. For discriminant validity correlation of consumer-brand relationship was compared with that of an involvement, which is a similar concept with consumer-based relationship. It also indicated dependent correlations by Cohen and Cohen (1975, p.35) and results showed that it was different constructs from 6 sub-dimensions of consumer-brand relationship. Through the results of studies mentioned above, we were able to finalize that sub-dimensions of consumer-brand relationship can viewed from one-dimensional constructs. This means that the one-dimensional construct of consumer-brand relationship can be viewed with reliability and validity. The result of this research is theoretically meaningful in that it assumes consumer-brand relationship in a one-dimensional construct and provides the basis of methodologies which are previously preformed. It is thought that this research also provides the possibility of new research on consumer-brand relationship in that it gives root to the fact that it is possible to manipulate one-dimensional constructs consisting of consumer-brand relationship. In the case of previous research on consumer-brand relationship, consumer-brand relationship is classified into several types on the basis of components consisting of consumer-brand relationship and a number of studies have been performed with priority given to the types. However, as we can possibly manipulate a one-dimensional construct through this research, it is expected that various studies which make the level or strength of consumer-brand relationship practical application of construct will be performed, and not research focused on separate types of consumer-brand relationship. Additionally, we have the theoretical basis of probability in which to manipulate the consumer-brand relationship with one-dimensional constructs. It is anticipated that studies using this construct, which is consumer-brand relationship, practical use of dependent variables, parameters, mediators, and so on, will be performed.

  • PDF