• Title/Summary/Keyword: Measuring parameters

Search Result 1,230, Processing Time 0.032 seconds

Accuracy of 5-axis precision milling for guided surgical template (가이드 수술용 템플릿을 위한 5축 정밀가공공정의 정확성에 관한 연구)

  • Park, Ji-Man;Yi, Tae-Kyoung;Jung, Je-Kyo;Kim, Yong;Park, Eun-Jin;Han, Chong-Hyun;Koak, Jai-Young;Kim, Seong-Kyun;Heo, Seong-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.4
    • /
    • pp.294-300
    • /
    • 2010
  • Purpose: The template-guided implant surgery offers several advantages over the traditional approach. The purpose of this study was to evaluate the accuracy of coordinate synchronization procedure with 5-axis milling machine for surgical template fabrication by means of reverse engineering through universal CAD software. Materials and methods: The study was performed on ten edentulous models with imbedded gutta percha stoppings which were hidden under silicon gingival form. The platform for synchordination was formed on the bottom side of models and these casts were imaged in Cone beam CT. Vectors of stoppings were extracted and transferred to those of planned implant on virtual planning software. Depth of milling process was set to the level of one half of stoppings and the coordinate of the data was synchronized to the model image. Synchronization of milling coordinate was done by the conversion process for the platform for the synchordination located on the bottom of the model. The models were fixed on the synchordination plate of 5-axis milling machine and drilling was done as the planned vector and depth based on the synchronized data with twist drill of the same diameter as GP stopping. For the 3D rendering and image merging, the impression tray was set on the conbeam CT and pre- and post- CT acquiring was done with the model fixed on the impression body. The accuracy analysis was done with Solidworks (Dassault systems, Concord, USA) by measuring vector of stopping’s top and bottom centers of experimental model through merging and reverse engineering the planned and post-drilling CT image. Correlations among the parameters were tested by means of Pearson correlation coefficient and calculated with SPSS (release 14.0, SPSS Inc. Chicago, USA) ($\alpha$ = 0.05). Results: Due to the declination, GP remnant on upper half of stoppings was observed for every drilled bores. The deviation between planned image and drilled bore that was reverse engineered was 0.31 (0.15 - 0.42) mm at the entrance, 0.36 (0.24 - 0.51) mm at the apex, and angular deviation was 1.62 (0.54 - 2.27)$^{\circ}$. There was positive correlation between the deviation at the entrance and that at the apex (Pearson Correlation Coefficient = 0.904, P = .013). Conclusion: The coordinate synchronization 5-axis milling procedure has adequate accuracy for the production of the guided surgical template.

A Study on the Dynamic Behavior Characteristics of a Small Fishing Crane (소형 어로 크레인의 동적 거동 특성에 관한 연구)

  • 이원섭;이대재
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.3
    • /
    • pp.163-173
    • /
    • 2001
  • The dynamic behavior characteristics of a small fishing crane for inshore and coastal fishing vessels was experimentally analyzed in order to improve the fishing operation and to reduce considerably manual work of fisherman. The small fishing crane was designed to be controlled electro-hydraulically by means of proportional valves and solenoid valves, and also to be controlled the speed of each operation. The dynamic behavior characteristics was investigated by measuring the changes of parameters such as oil pressure, swing angle of load, load tension, the lifting angle and the swing angle of crane arm when the arms extended in a side way was given a test load. The results obtained are summarized as follows: 1. The designed small fishing crane can be proportionally controlled by means of proportional valves and rapidly by operating the solenoid valves, respectively. The capacity, turning angle, maximum reach of crane were 2 T-M, $180^\circ$, 3.7m, respectively. 2. The vertical change of crane arm on the extension of lifting cylinder was $1.2^\circ$/cm, and the swing speed of crane arm due to the extension of swing cylinder by on/off operations of solenoid valves was $15^\circ$/sec, with the swing period of 1.4 sec and the angle fluctuation of $\pm$11.0$^{\circ}$. 3. When changing simultaneously the horizontal and vertical positions of the lifting load by on/off operations of solenoid valves, the swing and lifting speeds of crane arm were $4.46^\circ$/sec and $6.4^\circ$/sec, respectively. 4. The movements of the designed crane were particularly smooth as they are controlled with the aid of proportional valves than by means of solenoid valves.

  • PDF

Flip Angle of the Optimal T1 Effect Using FLASH Pulse Sequence at 3T Abdominal MRI (FLASH를 이용한 3T 복부검사에 있어서 최적의 T1효과를 위한 적정 Flip Angle)

  • Han, Jae-Bok;Choi, Nam-Gil
    • Journal of radiological science and technology
    • /
    • v.32 no.1
    • /
    • pp.101-106
    • /
    • 2009
  • Purpose of this study is to compare the signal intensity (SI) and CNR with T1 weighted image using FLASH at 3T abdominal MRI by varying flip angle (FA). Totally 20 patients (male : 12, female : 8, Age : $28{\sim}63$ years with mean : 51) were examined by 3 Tesla MR scanner (Magnetom Tim Trio, SIEMENS, Germany) with 8 channel body array coil between september and October 2008. Imaging parameters were as follows : FLASH sequence, TR : 120 ms, TE : minimum, FOV (field of view) : $360{\times}300\;mm$, Matrix : $256{\times}224$, slice : 6 mm, scan time : 15 sec and Breath-hold technique. Abdominal image, with a 50 ml syringe filled with water placed in the FOV measuring the water signal, were acquired with varying FA through $10^{\circ}$ to $90^{\circ}$ with $10^{\circ}$ interval. SI's were measured three times at liver parenchyme, water, spleen and background and averaged. The CNR's were measured between the ROIs (region of interest). Statistic analysis was performed with ANOVA test using SPSS software (version 17.0). Less than FA $30^{\circ}$, abdominal images were severely inhomogeneity. Especially, T1 effect of water signal was weak. As the flip angle increased, the signal intensity decreased at all the regions. Especially, flip angle of the highest signal intensity was observed with $40^{\circ}$ at the liver parenchyme, $20^{\circ}$ at water, $30^{\circ}$ at the spleen, respectively. The CNR between liver and water was -60.92 at FA $10^{\circ}$ and 15.16 at FA $80^{\circ}$. The CNR between liver and spleen was -3.18 at FA $10^{\circ}$ and 9.65 at $80^{\circ}$. In conclusion, FA $80^{\circ}$ is optimal for T1 weighted effect using FLASH pulse sequence at 3.0 T abdominal MRI.

  • PDF

A Study of Cleaning Technology for Zirconium Scrap Recycling in the Nuclear Industry (원자력산업에서 지르코늄 스크랩 재활용을 위한 세정기술에 관한 연구)

  • Lee, Ji-Eun;Cho, Nam-Chan;An, Chang-Mo;Noh, Jae-Soo;Moon, Jong-Han
    • Clean Technology
    • /
    • v.19 no.3
    • /
    • pp.264-271
    • /
    • 2013
  • In this study, we optimized the removal condition of contaminants attached on the scrap surface to recycle the scrap generated from the Zr alloy tube manufacturing process back to the nuclear grade. The main contaminant is remnant of watersoluble cooling lubricant that is used in the pilgering manufacture during the tube production, and it is assumed to be compressed and carbonized on the surface of tube. Zirlo alloy tube of ${\phi}9.50mm$, which has high occurrence frequency of scrap, was selected as the object to be cleaned, and cleaning abilities of reagents were evaluated by measuring the characteristics of contaminants remained and by analyzing the surface of the tube after cleaning process. For evaluation of each cleaning agent, we selected two types of sodium hydroxide series and three types of potassium hydroxide series. Furthermore, to confirm dependence on tempe-rature and ultrasonic intensities, cleaning at the room temperature, $40^{\circ}C$, and $60^{\circ}C$ was conducted, and results showed that higher the cleaning temperature and higher the ultrasonic intensity, better the cleaning effect. As a result of the bare-eye inspection, while the use of sodium hydroxide provided satisfactory condition on the tube surface, the use of potassium hydroxide series provided satisfactory condition on the tube surface only when the ultrasonic intensity was over 120 W. In the cleaning effect analysis using the gravimetric method, cleaning efficiency of sodium hydroxide series was as high as 97.6% ($60^{\circ}C$, 120 W), but since the tube surface condition was poor after the use of potassium hydroxide, the gravimetric method was not appropriate. In the analytical result of surface contaminants on the tube surface, C, O, Ca, and Zr were detected, and mainly C and O dominated the proportion of contaminants. It was also found that the degree of cleaning on the tube affected the componential ratio of C and O; if the degree of cleaning is high, or if cleaning is well-conducted, the proportion of C is decreased, and the proportion of O is increased. Based on these results, optimal cleaning for application in the industry can be expected by categorizing cleaning process into three steps of Alkali cleaning, Rinsing, and Drying and by adjusting cleaning parameters in each step.

Comparison of Effectiveness about Image Quality and Scan Time According to Reconstruction Method in Bone SPECT (영상 재구성 방법에 따른 Bone SPECT 영상의 질과 검사시간에 대한 실효성 비교)

  • Kim, Woo-Hyun;Jung, Woo-Young;Lee, Ju-Young;Ryu, Jae-Kwang
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.9-14
    • /
    • 2009
  • Purpose: Nowadays in the nuclear medicine, many studies and efforts are being made to reduce the scan time, as well as the waiting time to be needed to execute exams after injection of radionuclide medicines. Several methods are being used in clinic, such as developing new radionuclide compounds that enable to be absorbed into target organs more quickly and reducing acquisition scan time by increase the number of Gamma Camera detectors to examine. Each medical equipment manufacturer has improved the imaging process techniques to reduce scan time. In this paper, we tried to analyze the difference of image quality between FBP, 3D OSEM reconstruction methods that commercialized and being clinically applied, and Astonish reconstruction method (A kind of Iterative fast reconstruction method of Philips), also difference of image quality on scan time. Material and Methods: We investigated in 32 patients that examined the Bone SPECT from June to July 2008 at department of nuclear medicine, ASAN Medical Center in Seoul. 40sec/frame and 20sec/frame images were acquired that using Philips‘ PRECEDENCE 16 Gamma Camera and then reconstructed those images by using the Astonish (Philips’ Reconstruction Method), 3D OSEM and FBP methods. The blinded test was performed to the clinical interpreting physicians with all images analyzed by each reconstruction method for qualitative analysis. And we analyzed target to non target ratio by draws lesions as the center of disease for quantitative analysis. At this time, each image was analyzed with same location and size of ROI. Results: In a qualitative analysis, there was no significant difference by acquisition time changes in image quality. In a quantitative analysis, the images reconstructed Astonish method showed good quality due to better sharpness and distinguish sharply between lesions and peripheral lesions. After measuring each mean value and standard deviation value of target to non target ratio with 40 sec/frame and 20sec/frame images, those values are Astonish (40 sec-$13.91{\pm}5.62$ : 20 sec-$13.88{\pm}5.92$), 3D OSEM (40 sec-$10.60{\pm}3.55$ : 20 sec-$10.55{\pm}3.64$), FBP (40 sec-$8.30{\pm}4.44$ : 20 sec-$8.19{\pm}4.20$). We analyzed target to non target ratio from 20 sec and 40 sec images. And we analyzed the result, In Astonish (t=0.16, p=0.872), 3D OSEM (t=0.51, p=0.610), FBP (t=0.73, p=0.469) methods, there was no significant difference statistically by acquisition time change in image quality. But FBP indicates no statistical differences while some images indicate difference between 40 sec/frame and 20 sec/frame images by various factors. Conclusions: In the circumstance, try to find a solution to reduce nuclear medicine scan time, the development of nuclear medicine equipment hardware has decreased while software has marched forward at a relentless. Due to development of computer hardware, the image reconstruction time was reduced and the expanded capacity to restore enables iterative methods that couldn't be performed before due to technical limits. As imaging process technique developed, it reduced scan time and we could observe that image quality keep similar level. While keeping exam quality and reducing scan time can induce the reduction of patient's pain and sensory waiting time, also accessibility of nuclear medicine exam will be improved and it provide better service to patients and clinical physician who order exams. Consequently, those things make the image of department of nuclear medicine be improved. Concurrent Imaging - A new function that setting up each image acquisition parameter and enables to acquire images simultaneously with various parameters to once examine.

  • PDF

The Immunohistochemical Analysis for the Expression of Survivin, HSP, and Bcl-2 in Non-small Cell Lung Carcinoma (비소세포폐암에서 Survivin, HSP 및 Bcl-2 발현에 관한 면역조직화학적 분석)

  • Hong, Hyun-Ju;Hong, Seok-Gyun;Lee, Kye-Young;Kim, Woo-Ho;Lee, Choon-Taek;Yoo, Chul-Gyu;Han, Sung-Koo;Shim, Young-Soo;Kim, Young-Whan
    • Tuberculosis and Respiratory Diseases
    • /
    • v.52 no.5
    • /
    • pp.441-452
    • /
    • 2002
  • Background : Anti-apoptotic proteins may be involved in tumor development, progression and the response to treatment, Bcl-2 is by far the most studied anti-apoptotic protein. A novel inhibitor of apoptosis, designated survivin, and the heat shock proteins (HSPs) have recently been found in many human cancers. Immunohistochemical methods were used to determine the expression level of survivin, HSP70 and bcl-2 in non-small cell lung cancer (NSCLC) to evaluate their clinical significance. Materials and Methods : Tissue array slides were obtained from 99 surgically resected NSCLCs. Immunohistochemical staining was performed by an immuno-peroxidase technique using an avidin-biotinylated horseradish peroxidase complex. Anti-survivin rabbit polyclonal antibodies, anti-HSP70 mouse monoclonal antibodies and anti-bcl-2 mouse monoclonal antibodies were used as the primary antibodies. Results : Positive staining of survivin was detected in 33.3% of the cases. Survivin positivity is associated with to females and recurrence. A nonstatistically significant trend toward increased survivin expression was observed in non-smokers, and its expression inversely correlated with the number of cigarettes smoked in smokers. HSP70 was detected in 84.8% but this did not correlated with the clinicopathologic characteristics. Bcl-2 was detected in 18.2% and its expression correlated to tumor recurrence. No significant difference in the median survival time was noted in a comparison of all cases with survivin expression and those without. There was no association between HSP70 or bcl-2 expression and survival. Conclusion : Survivin expression was significantly associated with females and tumor recurrence. In addition its expression was inversely associated with the number of cigarettes smoked. However, HSP70 and bcl-2 expression were not associated with the clinical parameters or survival. This suggests that measuring the survivin levels may be useful in identifying patients at high risk for disease recurrence. Therefore, survivin might be a new diagnostic/therapeutic target in cancer.

The Correlation of Dyspnea and Radiologic Quantity in Patients with COPD (만성폐쇄성폐질환 환자에서 호흡곤란과 영상학적 정량과의 상관관계)

  • Jung, Eun Jung;Kim, Yang Ki;Lee, Young Mok;Kim, Ki-Up;Uh, Soo-Taek;Kim, Yong Hoon;Kim, Do Jin;Park, Choon Sik;Hwang, Jung Hwa
    • Tuberculosis and Respiratory Diseases
    • /
    • v.66 no.4
    • /
    • pp.288-294
    • /
    • 2009
  • Background: A lung hyperinflation, or air trapping, caused by expiratory flow-limitation contributes to dyspnea in patients with chronic obstructive pulmonary disease (COPD). Forced expiratory volume in 1 second ($FEV_1$) has served as an important diagnostic measurement of COPD, but does not correlate with patient-centered outcomes such as dyspnea. Therefore, this study was performed to investigate the role of radiologic quantity in evaluating the dyspnea in patients with COPD by measuring lung hyperinflation in chest x-ray and high resolution chest tomography (HRCT). Methods: Fifty patients with COPD were enrolled in this study. Their subjective dyspnea score (modified Borg scale dyspnea index), spirometry, and lung volume were measured. Simultaneous hyperinflations of chest x-ray score ("chest score") and degree of emphysema of HRCT ("HRCT score") were measured. The "chest score" were composed of lung length, retrosternal space width, and height of the arc of the diaphragm and "HRCT score" were composed of severity and extent of emphysema. Results: The mean age of patients was 69 years old and their mean $FEV_1$ was 51.7%. The Borg score significantly correlated with parameters of spirometry and lung volume, including FVC, $FEV_1$, $FEV_1$/FVC, RV, RV/TLC, and DLCO. The Borg score correlated well with "HRCT score", but did not correlate with "chest score". Also, the Borg scale correlates inversely with body mass index. Conclusion: The quantity of emphysema on chest HRCT may serve as an objective marker of dyspnea in patients with COPD.

Thermal-Denaturation of File Fish Myofibrillar Protein and Protective Effect of Sucrose, Sorbitol and Amino Acids (말쥐치 근원섬유단백질의 열안정성과 및 가지 첨가제의 영향)

  • CHOI Young-Joon;PYEUN Jae-Hyeung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.18 no.5
    • /
    • pp.455-463
    • /
    • 1985
  • Thermal-denaturation of myofibrillar protein of dorsal skeletal muscle from file fish was investigated by measuring denaturation constant($K_D$) and thermodynamic parameters at various temperatures. The protective effects of sucrose, sorbitol and amino acids when added individually or combined were also discussed. The denaturation rate as reflected in inactivation of myofibrillar protein Ca-ATPase was followed the first order reaction. The $K_D$ values at $25^{\circ}C,\;30^{\circ}C,\;and\;35^{\circ}C$ were $19.52{\times}10^{-5},\;112.25{\times}10^{-5},\;and\;247.20{\times}10^{-5}$, respectively. The activation energy of the reaction at $30^{\circ}C$ was 43 kcal/mole. The protective effects of sucrose, sorbitol, glycine, alanine and Na-glutamate were increased with the concentration but the effects of sorbitol and Na-glutamate decreased beyond 1.0 mole. Basic amino acids such as arginine and lysine did not revealed any protective effect on the thermal denaturation. In case of mixed addition, the effects of Na-glutamate to glycine, sorbitol to glycine, and sorbitol to sucrose or sorbitol to Na-glutamate were enhanced 1.2 to 7.0 times as much as that of control (ratio of mixing; 1:1, range of concentration; 0.5 to 1.25 mole). Under the frozen condition at $-20^{\circ}C$, two mixtures such as Na-glutamate to glycine and sorbitol to sucrose apparently revealed the protective effects.

  • PDF

Influence of VEGF Genetic Polymorphism on Peritoneal Solute Transport in Pediatric Dialysis Patients (소아 복막투석환자에서 혈관내피성장인자 유전자 다형성이 복막의 용질이동성에 미치는 영향)

  • Choi, Hyun-Jin;Paik, Kyung-Hoon;Cho, Hee-Yeon;Kang, Hee-Kyung;Cheong, Hae-Il;Choi, Yong;Ha, Il-Soo
    • Childhood Kidney Diseases
    • /
    • v.14 no.2
    • /
    • pp.166-173
    • /
    • 2010
  • Purpose : Genetic and clinical factors can influence the permeability of the peritoneal membrane. The peritoneal equilibration test (PET) is helpful in measuring peritoneal permeability in peritoneal dialysis (PD). We investigated the influence of genetic polymorphism of vascular endothelial growth factor (VEGF) on the PET parameters. Methods : Pediatric patients who underwent PET within 12 months of initiating PD at Seoul National University Children's Hospital and Samsung Medical Center were selected. The patients with positive history of peritonitis before PET were excluded. The VEGF -2578C/A, -14978T/C, -1154G/A, -634G/C, and +936C/T single-nucleotide polymorphisms were genotyped. Results : The mean 4-hour dialysate-to-plasma ratio for creatinine (D/P creatinine) and the mean 4-hour dialysate glucose to baseline dialysate glucose ratio (D/$D_0$ glucose) were $0.56{\pm}0.13$ and $0.43{\pm}0.11$, respectively. The patients with haplotype CTGGC showed higher 4-hour D/P creatinine ($0.67{\pm}0.12$ vs $0.50{\pm}0.09$, P=0.007) and lower 4-hour D/$D_0$ glucose ($0.35{\pm}0.12$ vs $0.47{\pm}0.08$, P=0.037) than those without haplotype CTGGC. Conclusion : The VEGF genetic polymorphism may influence the peritoneal solute transport.

A Performance Comparison of the Mobile Agent Model with the Client-Server Model under Security Conditions (보안 서비스를 고려한 이동 에이전트 모델과 클라이언트-서버 모델의 성능 비교)

  • Han, Seung-Wan;Jeong, Ki-Moon;Park, Seung-Bae;Lim, Hyeong-Seok
    • Journal of KIISE:Information Networking
    • /
    • v.29 no.3
    • /
    • pp.286-298
    • /
    • 2002
  • The Remote Procedure Call(RPC) has been traditionally used for Inter Process Communication(IPC) among precesses in distributed computing environment. As distributed applications have been complicated more and more, the Mobile Agent paradigm for IPC is emerged. Because there are some paradigms for IPC, researches to evaluate and compare the performance of each paradigm are issued recently. But the performance models used in the previous research did not reflect real distributed computing environment correctly, because they did not consider the evacuation elements for providing security services. Since real distributed environment is open, it is very vulnerable to a variety of attacks. In order to execute applications securely in distributed computing environment, security services which protect applications and information against the attacks must be considered. In this paper, we evaluate and compare the performance of the Remote Procedure Call with that of the Mobile Agent in IPC paradigms. We examine security services to execute applications securely, and propose new performance models considering those services. We design performance models, which describe information retrieval system through N database services, using Petri Net. We compare the performance of two paradigms by assigning numerical values to parameters and measuring the execution time of two paradigms. In this paper, the comparison of two performance models with security services for secure communication shows the results that the execution time of the Remote Procedure Call performance model is sharply increased because of many communications with the high cryptography mechanism between hosts, and that the execution time of the Mobile Agent model is gradually increased because the Mobile Agent paradigm can reduce the quantity of the communications between hosts.