• Title/Summary/Keyword: Measuring parameters

Search Result 1,230, Processing Time 0.033 seconds

Determination of Identifiable Parameters and Selection of Optimum Postures for Calibrating Hexa Slide Manipulators

  • Park, Jong-Hyuck;Kim, Sung-Gaun;Rauf, Abdul;Ryu, Je-Ha
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2737-2742
    • /
    • 2003
  • Kinematic calibration enhances absolute accuracy by compensating for the fabrication tolerances and installation errors. Effectiveness of calibration procedures depends greatly on the measurements performed. While the Cartesian postures are measured completely, all of the geometric parameters can be identified to their true values. With partial pose measurements, however, few geometric parameters may not be identifiable and effectiveness of the calibration results may vary significantly within the workspace. QR decomposition of the identification Jacobian matrix can reveal the non-identifiable parameters. Selecting postures for measurement is also an important issue for efficient calibration procedure. Typically, the condition number of the identification Jacobian is minimized to find optimum postures. This paper investigates identifiable parameters and optimum postures for four different calibration procedures - measuring postures completely with inverse kinematic residuals, measuring postures completely with forward kinematics residuals, measuring only the three position components, and restraining the mobility of the end-effector using a constraint link. The study is performed for a six degree-of-freedom fully parallel HexaSlide type paralle manipulator, HSM. Results verify that all parameters are identifiable with complete posture measurements. For the case of position measurements, one and for the case of constraint link, three parameters were found non-identifiable. Optimal postures showed the same trend of orienting themselves on the boundaries of the search space.

  • PDF

Accuracy evaluation of diagnostic parameters estimated by uroflowmetry technique measuring hydraulic pressure (수압측정 방식의 요류검사 진단매개변수의 정확도 평가)

  • Kim, Kyung-Ah;Choi, Seong-Su;Kim, Sung-Sik;Kim, Kun-Jin;Park, Kyung-Soon;Cha, Eun-Jong
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.413-418
    • /
    • 2007
  • Uroflowmetry is of great convenience to diagnose benign prostate hypertrophy common in aged men. The urinary flow rate is obtained by weight measurement using load cell, however, sensitive to impact noise. An alternative technique was recently proposed to measure hydraulic pressure instead of weight and demonstrated to introduce significantly reduced noise. In this paper, we described the measured diagnostic parameters between the weight and pressure measuring techniques in 10 normal men. The weight and pressure signals were simultaneously acquired during urination, converted into urine volumes, then differentiated to obtain flow rate signals, which showed very similar waveforms. Diagnostic parameters evaluated by pressure measuring technique were well correlated with the standard weight measuring technique (correlation coefficient > 0.99). Therefore, the new uroflowmetry based on hydraulic pressure measurement can provide accurate diagnostic parameters, which would be clinically valid.

Efficient Method for Recovering Spectral Reflectance Using Spectrum Characteristic Matrix (스펙트럼 특성행렬을 이용한 효율적인 반사 스펙트럼 복원 방법)

  • Sim, Kyudong;Park, Jong-Il
    • Journal of Korea Multimedia Society
    • /
    • v.18 no.12
    • /
    • pp.1439-1444
    • /
    • 2015
  • Measuring spectral reflectance can be regarded as obtaining inherent color parameters, and spectral reflectance has been used in image processing. Model-based spectrum recovering, one of the method for obtaining spectral reflectance, uses ordinary camera with multiple illuminations. Conventional model-based methods allow to recover spectral reflectance efficiently by using only a few parameters, however it requires some parameters such as power spectrum of illuminations and spectrum sensitivity of camera. In this paper, we propose an enhanced model-based spectrum recovering method without pre-measured parameters: power spectrum of illuminations and spectrum sensitivity of camera. Instead of measuring each parameters, spectral reflectance can be efficiently recovered by estimating and using the spectrum characteristic matrix which contains spectrum parameters: basis function, power spectrum of illumination, and spectrum sensitivity of camera. The spectrum characteristic matrix can be easily estimated using captured images from scenes with color checker under multiple illuminations. Additionally, we suggest fast recovering method preserving positive constraint of spectrum by nonnegative basis function of spectral reflectance. Results of our method showed accurately reconstructed spectral reflectance and fast constrained estimation with unmeasured camera and illumination. As our method could be conducted conveniently, measuring spectral reflectance is expected to be widely used.

Electrical Parameter Tests of Synchronous Reluctance Motor

  • Khang, Huynh Van;Hwang, Seon-Hwan;Kim, Jang-Mok;Ahn, Jin-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.211-213
    • /
    • 2007
  • The electrical parameters are used to calculate gains in the current regulator as well as to determine the reference currents of speed controller in various control strategies of Synchronous Reluctance Motors (SynRMs). Many methods of measuring or estimating the electrical parameters of SynRM have been proposed by other authors. But almost papers only measure or estimate in the limited conditions without fully considering the effects of inverter, connecting wire and magnetic saturation. The parameter results are usually different from the real system parameters. The drive performance, therefore, can not be good if using inaccurate parameters. In this paper, several methods used to measure the electrical parameters are introduced. The first method is LCR meter. And then, a method determining inductances by measuring AC current and voltage from AC power supply is presented. A new method with high reliability is proposed to measure the electrical parameters of SynRM. The experiment results verify the effectiveness of the new proposed method.

  • PDF

Study on the Identifiable Parameters and Optimum Postures for Calibrating Parallel Manipulators (병렬구조 로봇의 보정을 위한 보정 가능 변수 판별과 최적 자세 선정에 관한 연구)

  • Park, Jong-Hyuck;Kim, Sung-Gaun;Rauf, Abdul;Ryu, Je-Ha
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1476-1481
    • /
    • 2003
  • Kinematic calibration enhances absolute accuracy by compensating for the fabrication tolerances and installation errors. Effectiveness of calibration procedures depends greatly on the measurements performed. This paper investigates identifiable parameters and optimum postures for four different calibration procedures - measuring postures completely with inverse kinematic residuals, measuring postures completely with forward kinematics residuals, measuring only the three position components, and restraining the mobility of the end-effector using a constraint link. The study is performed for a six degree-of-freedom fully parallel HexaSlide type parallel manipulator, HSM. Results verify that all parameters are identifiable with complete posture measurements. For the case of position measurements, one and for the case of constraint link, three parameters were found non-identifiable. Selecting postures for measurement is also an important issue for efficient calibration procedure. Typically, the condition number of the identification Jacobian is minimized to find optimum postures. Optimal postures showed the same trend of orienting themselves on the boundaries of the search space.

  • PDF

Dynamic Thermal Rating of Transmission Line Based on Environmental Parameter Estimation

  • Sun, Zidan;Yan, Zhijie;Liang, Likai;Wei, Ran;Wang, Wei
    • Journal of Information Processing Systems
    • /
    • v.15 no.2
    • /
    • pp.386-398
    • /
    • 2019
  • The transmission capacity of transmission lines is affected by environmental parameters such as ambient temperature, wind speed, wind direction and so on. The environmental parameters can be measured by the installed measuring devices. However, it is impossible to install the environmental measuring devices throughout the line, especially considering economic cost of power grid. Taking into account the limited number of measuring devices and the distribution characteristics of environment parameters and transmission lines, this paper first studies the environmental parameter estimating method of inverse distance weighted interpolation and ordinary Kriging interpolation. Dynamic thermal rating of transmission lines based on IEEE standard and CIGRE standard thermal equivalent equation is researched and the key parameters that affect the load capacity of overhead lines is identified. Finally, the distributed thermal rating of transmission line is realized by using the data obtained from China meteorological data network. The cost of the environmental measurement device is reduced, and the accuracy of dynamic rating is improved.

Development of an Perceptual Video Quality Assessment Metric Using HVS and Video Communication Parameters (인간 시각 특성과 영상통신 파라미터를 이용한 동영상 품질 메트릭 개발)

  • Lee, Won-Kyun;Jang, Seong-Hwan;Park, Heui-Cheol;Lee, Ju-Yong;Suh, Chang-Ryul;Kim, Jung-Joon
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.155-158
    • /
    • 2007
  • In this paper, we solved the underestimation problem of PSNR, which is caused by repeated frames, by easily synchronizing original and decoded frames using the proposed marks. Also we propose full-reference system which can be applied for measuring the quality of various kinds of video communication systems, e.g. wireless handsets, mobile phones and applications for PC. In addition, we propose a new video quality assessment metric using video communication parameters, i.e. frame rate and delay. According to the experiments, the proposed metric is not only appropriate for real-time video communication systems but also shows better correlation with the subjective video quality assessment than PSNR. The proposed measuring system and metric can be effectively used for measuring and standardizing the video quality of future communications.

  • PDF

Room Acoustic Measurement System Using Impulse Response (임펄스응답을 이용한 실내음향 측정 시스템)

    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.5
    • /
    • pp.63-67
    • /
    • 1999
  • Recently, a method of measuring impulse response is widely used for a room acoustic evaluation instead of measuring reverberation time by white noise excitation. Comparing with the traditional reverberation time measurement, this method has many advantages such as good repeatability and the ability to extract various room acoustic parameters at one measurement. In this study, the author developed a measuring system that can extract mono-aural room acoustic parameters from an impulse response measured with MLS (Maximum Length Sequence) signal excitation. These room acoustic parameters include reverberation times(EDT, RT), speech intelligibilities(C50, C80, D, U50, U80, AI) and sound strength(G). This paper introduces the configuration of the developed measuring system, test results and discussions for the measurements at several rooms.

  • PDF

Zoom Lens Calibration for a Video Measuring System (컴퓨터 비젼을 이용한 정밀 측정 장비의 줌 렌즈 캘리브레이션)

  • Hahn, Kwang-Soo;Choi, Joon-Soo;Choi, Ki-Won
    • Journal of Internet Computing and Services
    • /
    • v.6 no.5
    • /
    • pp.57-71
    • /
    • 2005
  • Precise visual measurement applications, like video measuring system (VMS), use camera systems with motorized zoom lens for fast and efficient measurement. In this paper, we introduce an efficient calibration method for zoom lens of VMS controlled by servo motor. For the automated zoom lens calibration of the VMS, only zoom lens setting needs to be calibrated and parameters calibrated by zoom lens settings are image center and pixel size changed by zoom levels, The extrinsic parameters, like focus and iris, do not need to be calibrated since the parameters are usually fixed, It needs a lot of time and effort to calibrate the camera for ali the different zoom levels. In this paper, we also propose an efficient and fast zoom lens calibration method, which calculates the calibration parameters of the zoom lens settings for the minimum number of zoom levels and estimates other parameters for the uncalculated zoom levels using the interpolation of the calculated parameter values.

  • PDF

Development of an optimal measuring device selection system using neural networks (Neural Network을 이용한 최적 측정장비 결정 시스템 개발)

  • 손석배;박현풍;이관행
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.299-302
    • /
    • 2000
  • Various types of measuring devices are used for reverse engineering and inspection in different fields of industry such as automotive, aerospace, computer graphics, and home appliance. In order to measure a part easily and efficiently, it is important to select appropriate measuring device considering the characteristics of each measuring machine and part information. In this research, an optimal measuring device selection system using neural networks is proposed. There are two major steps: Firstly, the measuring information such as curvature, normal, type of surface, edge, and facet approximation is extracted from the CAD model. Second, the best suitable measuring device is proposed using the neural network system based on the knowledge of the measuring parameters and the measuring resources. An example of machine selection is implemented to evaluate the performance of the system.

  • PDF