• Title/Summary/Keyword: Measuring head

Search Result 411, Processing Time 0.023 seconds

Correlation between Unfavorable Split in the Distal Segment during the Bilateral Sagittal Ramus Osteotomy and Skeletal Relapse: Cone-Beam Computed Tomography Study

  • Kim, Young-Hoon;Lee, Baeksoo;Kwon, Yong-Dae;Ohe, Joo-Young;Lee, Jung-Woo;Jung, Junho;Lee, Seok Mo;Choi, Byung-Joon
    • Journal of Korean Dental Science
    • /
    • v.14 no.2
    • /
    • pp.110-117
    • /
    • 2021
  • Purpose: The purpose of this article is to study the relationship of unintentionally extended split in the distal segment during the bilateral sagittal split ramus osteotomy (BSSRO) and skeletal relapse. Materials and Methods: Twenty patients with mandibular prognathism were divided into two groups according to whether or not unintentionally extended split had occurred. Cone-beam computed tomography images were taken before surgery (T0), immediately after surgery (T1), and postoperatively at 6 months (T2). The stability was evaluated by measuring the change of Nasion perpendicular-Pogonion (N-Pog) distance. Result: Both groups showed mild advancement of Pog during follow-up. In both groups, the condyle head rotated inward and moved posterioinferiorly after surgery, but tended to return to their original position during follow-up. Conclusion: There was no statistically significant difference between the two groups in mandible position. Moreover, the condylar position was stable. If it is difficult to proceed reduction of the unintentionally extended split, careful inspection should be performed to prevent subsequent complications during follow-up.

Model Tests on a Plastic Pipe Pile for the Analysis of Noise, Energy Transfer Effect and Bearing Capacity due to Hammer Cushion Materials (해머 쿠션 재질에 따른 모형말뚝의 소음, 에너지 전달효율 및 지지력 분석)

  • Lim, Yu-Jin;Hwang, Kwang-Ho;Park, Young-Ho;Lee, Jin-Gul
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.12
    • /
    • pp.33-43
    • /
    • 2006
  • Driving tests using model plastic piles with different hammer cushion materials were performed in order to evaluate the efficiency of energy transfer ratio from the hammer, degree of vibration of the surrounding ground and noise due to impacting. A small pile driving analyzer (PDA) was composed using straingages and Hopkinson bar which is measuring force signal and pile-head velocity. The hammer cushion (cap block) materials used for the model driving tests were commercial Micarta, plywood, polyurethane, rubber (SBR) and silicone rubber. The highest energy transfer ratio was obtained from Micarta in the same soil and driving conditions. Micarta was followed by polyurethane, plywood, rubber and silicone in descending order. The more efficient energy transfdr ratio of the hammer cushion materials became, the bigger average noisy (sound) level was found. In addition, Micarta and polyurethane provided bigger bearing capacities than other materials compared in the same soil and driving conditions in which the static loading tests were performed at the end of driving.

Effects of grain-based pecking blocks on productivity and welfare indicators in commercial broiler chickens

  • Byung-Yeon Kwon;Hyun-Gwan Lee;Yong-Sung Jeon;Ju-Yong Song;Jina Park;Sang-Ho Kim;Dong-Wook Kim;Kyung-Woo Lee
    • Animal Bioscience
    • /
    • v.37 no.3
    • /
    • pp.536-546
    • /
    • 2024
  • Objective: This experiment was conducted to investigate the effect of grain-based pecking blocks on productivity and welfare status at two commercial broiler welfare-certified farms. Methods: Production and welfare indicators were assessed at two farms (designated Farm A and B). Both farms had two windowless houses with forced tunnel-type ventilation and housed broilers at stocking densities of approximately 16.7 birds/m2 (Farm A) and 16.8 birds/m2 (Farm B). Each house was divided into two or three equal sections and was provided with or without pecking blocks. Grain-based pecking blocks, measuring 25 × 25 × 25 cm, were given to broilers in both farms at 1 block per 1,000 birds. Various parameters including productivity (body weight and flock uniformity), corticosterone levels (in fecal droppings and feathers), footpad dermatitis, hock burn, feather dirtiness, gait score, litter quality, body surface temperature, and volatile fatty acids in fecal samples were assessed at 26 days of age, whereas litter quality was analyzed at 13 and 26 days of age. Results: There were no significant effects of providing pecking blocks on productivity (body weight and uniformity), fecal and feather corticosterone, welfare indicators (i.e., footpad dermatitis, hock burn, feather cleanliness, and gait score), and litter quality (i.e., moisture, nitrogen, and pH). No differences in body surface temperature between the control and enrichment treatments were noted in Farm B, but body surface temperatures of the head (p = 0.029) and legs (p = 0.011) in the enrichment vs. control group were elevated in Farm A. Butyrate concentration in the enrichment vs control group was higher in Farm B (p = 0.023), but this effect was not detected in Farm A. Conclusion: It is concluded that grain-based pecking blocks did not affect performance and welfare indicators. Further studies are warranted to elucidate the potential impact of grain-based pecking blocks on gut health indicators.

Boophone disticha attenuates five day repeated forced swim-induced stress and adult hippocampal neurogenesis impairment in male Balb/c mice

  • Nkosiphendule Khuthazelani Xhakaza;Pilani Nkomozepi;Ejekemi Felix Mbajiorgu
    • Anatomy and Cell Biology
    • /
    • v.56 no.1
    • /
    • pp.69-85
    • /
    • 2023
  • Depression is one of the most common neuropsychiatric disorders and is associated with dysfunction of the neuroendocrine system and alterations in specific brain proteins. Boophone disticha (BD) is an indigenous psychoactive bulb that belongs to the Amaryllidacae family, which is widely used in Southern Africa to treat depression, with scientific evidence of potent antidepressant-like effects. The present study examined the antidepressant effects of BD and its mechanisms of action by measuring some behavioural parameters in the elevated plus maze, brain content of corticosterone, brain derived neurotropic factor (BDNF), and neuroblast differentiation in the hippocampus of Balb/c mice exposed to the five day repeated forced swim stress (5d-RFSS). Male Balb/c mice were subjected to the 5d-RFSS protocol to induce depressive-like behaviour (decreased swimming, increased floating, decreased open arm entry, decreased time spent in the open arms and decreased head dips in the elevated plus maze test) and treated with distilled water, fluoxetine and BD. BD treatment (10 mg/kg/p.o for 3 weeks) significantly attenuated the 5d-RFSS-induced behavioural abnormalities and the elevated serum corticosterone levels observed in stressed mice. Additionally, 5d-RFSS exposure significantly decreased the number of neuroblasts in the hippocampus and BDNF levels in the brain of Balb/c mice, while fluoxetine and BD treatment attenuated these changes. The antidepressant effects of BD were comparable to those of fluoxetine, but unlike fluoxetine, BD did not show any anxiogenic effects, suggesting better pharmacological functions. In conclusion, our study shows that BD exerted antidepressant-like effects in 5d-RFSS mice, mediated in part by normalizing brain corticosterone and BDNF levels.

Comparison of Radiation Dose in the Measurement of MDCT Radiation Dose according to Correction of Temperatures and Pressure, and Calibration of Ionization Chamber (MDCT 선량측정에서 온도와 압력에 따른 보정과 Ionization Chamber의 Calibration 전후 선량의 비교평가)

  • Lee, Chang-Lae;Kim, Hee-Joung;Jeon, Seong-Su;Cho, Hyo-Min;Nam, So-Ra;Jung, Ji-Young;Lee, Young-Jin;Lee, Seung-Jae;Dong, Kyung-Rae
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.49-55
    • /
    • 2008
  • This study aims to conduct the comparative analysis of the radiation dose according to before and after the calibration of the ionization chamber used for measuring radiation dose in the MDCT, as well as of $CTDI_w$ according to temperature and pressure correction factors in the CT room. A comparative analysis was conducted based on the measured MDCT (GE light speed plus 4 slice, USA) data using head and body CT dosimetric phantom, and Model 2026C electrometer (RADICAL 2026C, USA) calibrated on March 21, 2007. As a result, the $CTDI_w$ value which reflected calibration factors, as well as correction factors of temperature and pressure, was found to be the range of $0.479{\sim}3.162mGy$ in effective radiation dose than the uncorrected values. Also, under the routine abdomen routine CT image acquisition conditions used in reference hospitals, patient effective dose was measured to indicate the difference of the maximum of 0.7 mSv between before and after the application of such factors. These results imply that the calibration of the ion chamber, and the correction of temperature and pressure of the CT room are crucial in measuring and calculating patient effective dose. Thus, to measure patient radiation dose accurately, the detailed information should be made available regarding not only the temperature and pressure of the CT room, but also the humidity and recombination factor, characteristics of X-ray beam quality, exposure conditions, scan region, and so forth.

  • PDF

Radiological Projection for Diagnosis of Shoulder Subluxation in Patients with Post-Stroke Hemiplegia (편마비 환자에서의 견관절 아탈구 진단에 유용한 촬영법)

  • Cho, Kwang-Ho;Kang, Yeong-Han
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.253-259
    • /
    • 2009
  • Purpose : The purpose of this study was to find out useful radiological projection of shoulder subluxation in patients with post-stroke hemiplegia. Methods : A total of 33 patients with post-stroke hemiplegia were included(20 men and 13 women, mean age 62.3 years) and having the subluxed shoulder over one finger breath. The shoulder subluxation was determined as the ratio of the radiographic vertical and horizontal distance. The vertical distance was determined by measuring the distance between the most inferolateral point of the acromion and the central point of the humeral head. The horizontal distance was determined by measuring the distance between the central point of the glenoid fossa and the central point of the humeral head. To measure of the shoulder subluxation, the shoulder AP, axial and transthoracic lateral projections were taken on both affected and unaffected shoulders. We analyzed the difference of subluxation distance by t-test. Results : When patients was in sitting position, the average time of being shoulder subluxation was 123 second. There was significant difference between supine($49.90{\pm}13.6\;mm$) and sitting position($60.72{\pm}16.3\;mm$) in the vertical distance of shoulder anterior-posterior projection. Also, there was significant difference on transthoracic lateral projections, Affected $35.92{\pm}6.2\;mm$, Unaffected $28.76{\pm}5.4\;mm$. But in case of shoulder axial projection(supine position), there was no significant difference (Unaffected and affected was $23.01{\pm}9.0\;mm$, $22.45{\pm}8.2\;mm$ each). Conclusion : Radiological projection of shoulder subluxation has diagnostic value when it goes after check out the process of subluxation through finger breadth test. For this, patients must be in sitting and shoulder neutral position about 2 minutes. In addition, Shoulder anterior-posterior and transthoracic projection were significant to diagnose subluxation. But in axial projection, there wasn't meaningful differences.

  • PDF

Egg and Larval Development of Chelon lauvergnii from Korea (한국산 가숭어, Chelon lauvergnii의 난 및 자치어의 형태발달)

  • Kim, Jin-Koo;Kim, Yong-Uk;Byun, Soon-Gyu
    • Korean Journal of Ichthyology
    • /
    • v.12 no.2
    • /
    • pp.137-145
    • /
    • 2000
  • The embryonic and larval development of Chelon lauvergnii (Eydoux & Souleyet) was surveyed by incubating artificially inseminated eggs with parent fishes obtained at Kang-wha island in the mid-western coastal area of Korea on June, 1997. The fertilized eggs were transparent, spherical in shape, measuring 0.95~1.08 mm in diameter, having a large oil globule, and their perivitelline space narrow, and began to hatch at 40 hrs. in water temperature $22{\pm}1^{\circ}C$. The newly hatched larvae were 2.35~2.68 mm in total length with 23 myomeres, anus opened, mouth closed, preanal length 58.7~61.6% of total length, oil globule located in posterior end of yolk sac. Melanophores, branch in shape, were distributed mainly along the ventro-lateral region of trunk part and a few on the anterior end of caudal part and surface of oil globule. The larvae measuring 3.08~3.36 mm in total length absorbed yolk material completely in 3 days after hatching, in which air bladder began to appear and mouth opened. In 8 days after hatching, the larva was measured 5.09 mm in total length, its posterior end of notochord began to flex upward and the caudal fin rays differentiated as 7, finfold of the second dorsal and anal fins appeared. In this time, melanophores, branch in shape, were concentrated in the anterior half region of the caudal part and a few also distributed on the top of head, snout region, ventral margin of lower jaw and isthmus region. In 12 days after hatching, the larva measuring 8.48 mm in total length completed all the fins (D. IV-9; P1. 16; P2. I, 5; A. II, 9) and reached to the juvenile stage. Melanophores, in this time, were distributed on the mid-lateral region of the caudal part in enlargment than before and a few also found in the dorso-lateral region of the trunk part, and in the cheek region.

  • PDF

Analysis Characteristic the Using Surface Electromyography of Head Neck and Around of Shoulder Muscles Express Scaling Working of the Dental Hygienist (치과위생사의 스켈링 작업 시 발현되는 두경부 및 견부 주위 근육들의 표면 근전도를 이용한 특성 분석)

  • Jeon, Eun-Suk;Nam, Kun-Woo;Ha, Mi-Sook
    • Journal of dental hygiene science
    • /
    • v.12 no.4
    • /
    • pp.437-442
    • /
    • 2012
  • The current research examines the aching part and the muscle activity that happens during scaling practice subject to 20 dental hygienic students and therefore propose a basic data according to the working attitude of the Dental Hygienist. During the scaling we used the free EMG (BTS Inc., Milan, Italy) to measure the muscle activity, and in order to check the musculoskeletal pain area we used the Nordic-style questionnaire, and the measured research results are as following: At the moment of scaling according to posture the occurrence of the pain showed no difference among the groups elbow, back, leg, knee, ankle/foot but in the neck, shoulder, wrist/hand, waist showed a high difference in the degree of pain according to posture. Results from measuring the muscular activity according to posture, in the group that had a good posture, the trapezius and brachial muscles showed a change according to time, and in the group that had a bad posture a high muscle activity was shown in larynx, trapezius and brachial muscles. In the muscle activity, the changing aspect between the two parts, the group that fulfilled a scaling in a good posture showed a low muscle activity, but in the group that fulfilled the scaling in a bad posture the muscle activity increased excessively. Therefore we examined that when fulfilling a scaling maintaining a bad posture can help in using more effectively the activity of the muscle, in the future I think there is a need to raise the office efficiency by subjecting to dental hyginiest that are in the clinics and performing experiments.

Exploration into the Determinants of Household Consumption: Liquidity Constraint and Family Characteristics (횡단면 자료를 이용한 가구소비 결정요인에 관한 연구 - 유동성 제약과 가구별 특성을 중심으로 -)

  • Hur, Seok-Kyun
    • KDI Journal of Economic Policy
    • /
    • v.27 no.1
    • /
    • pp.1-38
    • /
    • 2005
  • Our paper aims to estimate a household consumption function in the presence of liquidity constraints as well as household characteristics. Empirical findings from a Korean cross-sectional data (National Survey of Household Income and Expenditure) reveal that several family characteristics, such as household size, number of working members, children in school, and educational level and age of the household head, turn out to be critical determinants of household consumption. Especially, the influence of household size on consumption decision is shown to be highly significant, not only indirectly through its impact on household income, but also directly by affecting the household's preference for consumption itself. While, the other family characteristics primarily influences household income. Our paper distinguishes itself from existing literature in that it greatly improves the explanatory power of the estimated household consumption function by measuring the degree of the liquidity constraint rather than simply identifying its presence. Based on the assumption that the present value of human capital is a function of household characteristics, the degree of the liquidity constraint is represented by the underestimated portion of the human capital. Such a method of implementing the liquidity constraint is useful in treating various types of assets according to their liquidity. Finally, our estimated household consumption function is applied to decompose cross-sectional variances of consumption inequality. The analysis confirms that the overall alleviation in liquidity constraints in Korea after the 1997 currency crisis reduced consumption inequality despite the worsening of income inequality and changes in the demographic composition of family characteristics during the same period.

  • PDF

COMPARATIVE STUDIES OF THE ADHESIVE QUALITIES OF POLYCARBOXYLATE CEMENTS (카복실레이트계 시멘트의 접착력에 관한 비교 연구)

  • Lee, Han-Moo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.17 no.1
    • /
    • pp.23-34
    • /
    • 1979
  • In this study, the adhesive strength of three commercial polycarboxylate cements to ten types of dental casting alloys, such as gold, palladium, silver, indium, copper, nickel, chromium, and human enamel and dentine were measured and compared with that of a conventional zinc phosphate cement. The $8.0mm{\times}3.0mm$ cylindrical alloy specimens were made by casting. The enamel specimens were prepared from the labial surface of human upper incisor, and the dentine specimens were prepared from the occulusal surface of the human molar respectively. Sound extracted human teeth, which had been kept in a fresh condition since, extraction, were mounted in a wax box with a cold-curing acrylic resin to expose the flattened area. The mounted teeth were then placed in a Specimen Cutter (Technicut) and were cut down under a water spray, and then the flat area on the all specimens were ground by hand with 400 and 600 grit wet silicone carbide paper. Two such specimens were then cemented together face-to-face with freshly mixed cement, and moderate finger pressure was applied to squeeze the cement to a thin and uniform film. All cemented specimens were then kept in a thermostatic humidor cabinet regulated at $23{\pm}2^{\circ}C.$ and more than 95 per cent relative humidity and tested after 24 hours and 1 week. Link chain was attached to each alloy specimen to reduce the rigidity of the jig assembly, and then all the specimens were mounted in the grips of the Instron Universal Testing Machine, and a tensile load was delivered to the adhering surface at a cross head speed of 0.20 mm/min. The loads to which the specimens were subjected were recorded on a chart moving at 0.50 mm/min. The adhesive strength was determined by measuring the load when the specimen separated from the cement block and by dividing the load by the area. The test was performed in a room at $23{\pm}2^{\circ}C.$ and $50{\pm}10$ per cent relative humidity. A minimum of five specimens were tested each material and those which deviated more than 15 per cent from the mean were discarded and new specimens prepared. From the experiments, the following results were obtained. 1) It was found that the adhesive strength of the polycarboxylate cement to all alloys tested was considerably greater than that of the zinc phosphate cement. 2) The adhesive strength of the polycarboxylate cements was superior to the non precious alloys, such as the copper, indium, nickel and chromium alloys, but it was inferior to the precious gold, silver and palladium alloys. 3) Surface treatment of the alloy was found to be an important factor in achieving adhesion. It appears that a polycarboxylate cement will adhere better to a smooth surface than to a rough one. This contrasts with zinc phosphate cements, where a rough helps mechanical interlocking. 4) The adhesion of the polycarboxylate cement with enamel was found superior to its adhesion with dentine.

  • PDF