• 제목/요약/키워드: Measuring head

검색결과 413건 처리시간 0.024초

Tribological diagnostics of machinery

  • Myshkin, N.K.
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1990년도 제11회 학술강연회초록집
    • /
    • pp.7-31
    • /
    • 1990
  • Tribologicsl diagnostics as the ensemble of means and methods of continuous monitoring of the state of friction characteristics of moving junctions is playing an ever important part in the development of friction, lubrication, and wear theory end practice. The scheme presenting the main areas of tribological diagnostics is given in Fig. I. This growing part of TD is determined by the general tendency of modern technology, expressed in an attempt to organically combine the functions of measuring, evaluating,and predicting the parameters and characteristics of the processee taking place in the operating device. The logical result of this integration in future is the closed system correcting its operation in accordance with sn established program. Unfortunately, tribotechnicsl devices are still very far from such an ideal system at the present time. While in the friction assemblies with hydrodynamic lubrication it is possible in the first approximation to realize feed-backs in the lubricant circulation system with the aid of monitoring of the pressure, temperature and filtration, in the systems operating without lubrication and with boundary lubricetion even the process of selection of the diagnostic parameters has not been completed.

  • PDF

골프공의 속도 측정 (Measuring of Golf Ball's Velocity)

  • 신성윤;김희애;장대현;이현창;이양원
    • 한국컴퓨터정보학회:학술대회논문집
    • /
    • 한국컴퓨터정보학회 2013년도 제48차 하계학술발표논문집 21권2호
    • /
    • pp.123-125
    • /
    • 2013
  • 우리는 흔히 골프 클럽의 휘둘러 골프공이 맞아 나가는 것을 보게 된다. 본 논문에서는 골프채 헤드가 골프공을 일정속도로 움직여 치고 난 후 골프채의 헤드는 같은 방향으로 일정 속도로 움직일 때 골프공을 치고 날아가는 골프공의 속도를 구한다. 골프공을 치기 전의 속도가 각각 다를 경우의 골프공의 속도를 각각 구한다. 골프를 칠 때 헤드의 속도, 골프공의 질량, 임팩트, 임팩트 후의 날아가는 속도, 그리고 임팩트 후의 이동 방향 등을 쉽게 알아보도록 하는 것이 본 논문의 목적이다.

  • PDF

TSSG-pulling of Sillenite $Bi_{12}TiO_{20}$ for EOS Application

  • Miyazawa, Shintaro
    • 한국결정성장학회:학술대회논문집
    • /
    • 한국결정성장학회 1999년도 PROCEEDINGS OF 99 INTERNATIONAL CONFERENCE OF THE KACG AND 6TH KOREA·JAPAN EMG SYMPOSIUM (ELECTRONIC MATERIALS GROWTH SYMPOSIUM), HANYANG UNIVERSITY, SEOUL, 06월 09일 JUNE 1999
    • /
    • pp.227-250
    • /
    • 1999
  • The reproducibility of successive growth of Bi12TiO20(BTO) single crystals using a top-seeded solution growth (TSSG) pulling method was evaluated by measuring the lattice constants and their standard deviations. A substantial phase diagram in the region close to the stoichiometric BTO was established experimentally for this purpose, and the existence of a retrograde solid solution close to a BTO was clarified. It was emphasize that a starting solution, with a 10.0~10.1 mol% TiO2 concentration, results in large single crystals with a highly homogeneous lattice constant of within $\pm$1x10-4$\AA$, when the solidified fraction of the grown crystal is less than about 45%. A wavelength dispersion of refractive index was measured for the first time, an it was verified that the refractive index of BTO is larger than that of BSO(Bi12TiO20), allowing the voltage sensitivity of EOS higher than the case with BSO as a probe head.

  • PDF

마이크로 캔틸레버 굽힘 측정을 위한 센싱시스템 (Sensing System for Measuring Deflection of Microcantilever)

  • 김현철;이상헌
    • 대한기계학회논문집B
    • /
    • 제36권9호
    • /
    • pp.961-964
    • /
    • 2012
  • 원자현미경에서 시편의 높이정보를 얻기 위한 마이크로 캔틸레버의 굽힘은 optical lever 방식이나 간섭원리에 기반한 방식으로 이루어졌으나, 부피와 가격적인 측면에서 이들 방식은 많은 개선의 여지를 가지고 있다. 따라서 본 논문에서는 이전 방식의 단점을 극복하기 위하여, 간단한 구조로 구현이 가능한 비점 수차방식을 기반으로한 광픽업헤드를 이용하여 마이크로 캔틸레버의 굽힘 측정시스템을 개발하였다. 개발된 시스템은 실험실에서 제작한 원자현미경에 적용하여 그 가능성을 확인하였다.

Experimental Analysis of Radiative Heat Interchange on Furnace Exit Plane of a Steam Boiler

  • Ahn, Kook-Young;Antonovsky, Vjacheslav-Ivanovich
    • Journal of Mechanical Science and Technology
    • /
    • 제15권2호
    • /
    • pp.239-247
    • /
    • 2001
  • Measured radiative heat fluxes on the furnace exit plane of a heavy duty power boiler of steam output 1650 T/h are discussed. A high-ash pulverized bituminous coal was used. Such measurements are necessary to improve heat fluxes inside a steam boiler furnace was manufactured. An extra small heat radiation sensor was placed in the water cooled head of the probe. The sensor had no direct contact with furnace gases and measured only the radiant energy. There was no exposure to convective heat transfer. With the radiometric probe, one can obtain a spherical indicatrix of radiation intensity as well as hemispherical radiative heat flux incident on any surface passing through a measuring point inside the furnace. Thus, the quantity of radiation energy, passing through the furnace exit plane, to the convective heating surfaces and the quantity of radiation energy going in the opposite direction were measured. A formula for relative radiative heat flux on the furnace exit plane has been proposed.

  • PDF

단기통 엔진 헤드에서 흡기포트의 정상유동에 관한 연구 (A Study on the Steady Flow of Intake Port in Single Cylinder Engine Head)

  • 김대열;최수광
    • 한국공작기계학회논문집
    • /
    • 제16권4호
    • /
    • pp.13-21
    • /
    • 2007
  • This paper presents characteristics of steady flow by variation of a combustion chamber and an intake port. Gas flow field inside a combustion chamber is the important factor in improving combustion stability and reduction of emission level. The flow characteristics such as flow coefficient, tumble ratio and swirl ratio are measured by the steady flow rig test with an impulse meter in this study. In the measuring, the valve lifts are varied between 1mm to 10mm. The three combustion chambers and two intake ports were applied to the steady flow apparatus in order to investigate the effect of swirl and tumble on the in-cylinder flow. As a result, tumble ratio were found to be different by variation of the combustion chambers and the intake ports. The data from the present study can be applied to design of a similar engine as basic data.

열차의 운행패턴과 속도에 따른 한국형 고속전철용 판토그라프의 접촉력과 가속도 거동의 변화 경향 (Variation Trends of the Contact Force between Pantograph-Catenary and Acceleration Behavior According to the Train Running Speed and Driving Pattern in Korean High Speed Train)

  • 목진용;김영국;박춘수;김기환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.200-205
    • /
    • 2004
  • The pantograph for Korean High Speed Train was developed and had been evaluating by through 'G7-R&D project for home grown high speed train technology' In this study, in mechanical aspect, the variation trend of contact force between pantograph and catenary according to the train running speed and driving pattern is conducted. A measuring system for current collecting performance and mechanical characteristics is used for this study, developed and installed on the prototype Korean High Speed Train, and physical characteristics were measured while the KHST runs on the test track. Through this study, remarkable trends of variation are found and analyzed from measured acceleration and vertical contact force between the pan head in pantograph and contact wire in catenary system according to the driving pattern and the train raised a running speed up to 300km/h.

  • PDF

New Dynamic Fiber Orientation Sensor Based on Dielectric Anisotropy Measurement Technology

  • Sawamoto, Hidetada;Nagata, Shinichi
    • 한국펄프종이공학회:학술대회논문집
    • /
    • 한국펄프종이공학회 2006년도 PAN PACIFIC CONFERENCE vol.1
    • /
    • pp.161-166
    • /
    • 2006
  • A new fiber orientation sensor has been developed and tested on an actual paper machine to demonstrate its capability to function as a real-time monitoring system. First, we demonstrate the ability of the sensor system to detect the change in the fiber orientation angle while the sensor head, and not the paper, was intentionally rotated from $-90^{\circ}\;to\;+70^{\circ}$ with respect to the paper-traveling direction. Next, we demonstrate that this system can successfully detect the change in the magnitude and angle of fiber orientation in running paper when the direction of material flow on the wire was changed on the paper machine. The angle and magnitude of fiber orientation were independently confirmed by SST and MOA measurements. Furthermore, we found that the system was capable of measuring the basis weight and the moisture content of running paper while detecting the angle and magnitude of fiber orientation.

  • PDF

TSSG-pulling of sillenite $Bi_{12}TiO_{20}$ for EOS application

  • Miyazawa, Shintaro
    • 한국결정성장학회지
    • /
    • 제9권4호
    • /
    • pp.424-431
    • /
    • 1999
  • The reproducibility of successive growth of $Bi_{12}TiO_{20}$ (BTO) single crystlas using a top-seeded solution growth (TSSG) pulling method was evalutated by measuring the lattice constants and their standard deviations. A substantial phase diagram in the region close to the stoichiometric BTO was established expermentally for this purpose, and the existence of a retrograde solid solution close to a BTO was clarified. It was emphasized that a starting solution, with a 10.0~10.1 mol% $TiO_{2}$ concentration, results in large single crystals with a highly homogeneous lattice constant of within ${\pm}1{\times}10^{-4}\AA$, when the solidified fraction of the grown crystal is less than about 45 %. A wavelength dispersion of refractive index was measrued for the first time, and it was verified that the refractive index of BTO is larger than that of BSO($Bi_{12}TiO_{20}$), allowing the voltage sensitivity of EOS higher than the case with BSO as a probe head.

  • PDF

Specific Heat Measurement of Insulating Material using Heat Diffusion Method

  • Choi, Yeon-Suk;Kim, Dong-Lak
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권2호
    • /
    • pp.32-35
    • /
    • 2012
  • The objective of the present work is to develop a precise instrument for measuring the thermal property of insulating material over a temperature range from 30 K to near room temperature by utilizing a cryocooler. The instrument consists of two thermal links, a test sample, heat sink, heat source and vacuum vessel. The cold head of the cryocooler as a heat sink is thermally anchored to the thermal link and used to bring the apparatus to a desired temperature in a vacuum chamber. An electric heater as a heat source is placed in the middle of test sample for generating uniform heat flux. The entire apparatus is covered by thermal shields and wrapped in multi-layer insulation to minimize thermal radiation in a vacuum chamber. For a supplied heat flux the temperature distribution in the insulating material is measured in steady and transient state. The thermal conductivity of insulating material is measured from temperature difference for a given heat flux. In addition, the specific heat of insulating material is obtained by solving one-dimensional heat diffusion equation.