• Title/Summary/Keyword: Measuring control standard

Search Result 200, Processing Time 0.031 seconds

Studies on sterile filters in the preparation of N-13 ammonia injection (N-13 암모니아 주사액 제조 시 멸균필터의 흡착율 차이에 관한 비교 평가)

  • Oh, Chang Bum;Kim, Si Hwal;Cha, Min Jung;Shin, Jin;Ji, Yong Gi;Choi, Sung Ook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.64-68
    • /
    • 2019
  • Purpose In the preparation process for N-13 Ammonia injections, there were radioactive medicines adsorbed on filters remarkably. Hereby, we have compared the adsorption rate and quality test on Millex GS filter and Satorious Minisart filter, both representatively hydrophilic sterilizing filters, also evaluated which filter is more accommodative for N-13 Ammonia injection. Materials and Methods The filters used for sterilization of N-13 Ammonia injections were Millex GS filter($0.22{\mu}m$) mand Satorious Minisart filter ($0.2{\mu}m$), which are generally used to strain aqueous solutions. After the N-13 Ammonia passes through each sterilization filter, the adsorption rate of the filter (n=10) is determined by measuring not only the radioactivity through the filter also the amount of radioactivity remaining in it using a Dose Calibrator. The N-13 Ammonia injections after each filter is tested by the quality control test to conform to the Samsung Medical Center standard. Results The ratio of radioactivity passed through Millex GS indicated $29.0{\pm}17.6%$. Satorious Minisart filters output was $80.9{\pm}3.2%$, respectively. Each ratio of radioactivity adsorbed on the sterile filter was $71.0{\pm}17.6%$ for Millex GS and $19.1{\pm}3.2%$ for the Satorious Minisart filters, respectively. Furthermore, on the ratio of filtered radioactivity, Using Satorious Minisart filter showed about 2.8 times higher than using Millex GS filter. The quality testing of N-13 Ammonia injections through each filter met the Samsung Medical Center standard. Conclusion The Millex GS filter is composed of cellulose acetate and cellulose nitrate, whereas the Satorious Minisart filter if composed only of cellulose acetate. Therefore, the presence of cellulose nitrate in the membrane seems to have made differences. Therefore, the use of Satorious Minisart filter in the preparation of N-13 Ammonia injection solution minimized the loss of radioactive medicines due to filter adsorption, thereby improving the synthesis yield.

Investigation on Factors Influencing the Quality of Life of Arthritis Patients (관절염환자의 삶의 질에 영향을 미치는 요인탐색)

  • Oh, Hyun Ja
    • Korean Journal of Adult Nursing
    • /
    • v.12 no.3
    • /
    • pp.431-451
    • /
    • 2000
  • In this paper, I will examine the variables influencing the Quality of Life of arthritis patients and present basic materials which help arthritis patients have positive thinking in life and ultimately lead a satisfactory life. The subjects for this study are 231 inpatients and outpatients with arthritis living in J and K city in Chonbug Province. For the analysis of collected data I employed the SAS program. The variables for characteristics and the quality of life were analysed by descriptive statistics, T-test and ANOVA, and the relations among variables were analysed through Pearson Correlation; the Regression method was employed to predict the factors affecting quality of life. For the validity of reliance on measuring equipment Cronbach Alpha was used. The results of the study are as follows : (1) The mean score of quality of life of arthritis patients is 3.09(5 in the maximum). The general characteristics which affect the quality of life are age(F=5.13, p=0.0006), standard of education(F=6.49, p=0.0003), marriage status(F=7.77, p=0.0005), monthly pay(F=4.37, p=0.0020), medical benefits (F=4.85, p=0.0087), and supports(F=4.39, p=0.0050). For the disease-related characteristics, there is a significant difference in the 6 items: pain control method(F=5.92, p= 0.0002), physical therapy(F=3.25, p=0.013), whethere or not patients exercise(F=4.62, p=0.0000), regularity of exercise(F=4.79, p=0.0000), frequency of exercise(F=6.29, p=0.0001), and amount of exercise(F=4.62, p=0.0043). Depending on the type of arthritis, there is also a significant difference in the degree of pain felt. The patients with infectious arthritis suffer from pain the most, followed by those with gout, rheumatism and degenerative arthritis, in that order. Although statistics don't show any convincing evidence, those with gout perceive that they are in best health condition, followed by those with rheumatism, degenerative arthritis, and infectious arthritis, in that order(F=2.23, p=0.0669). (2) The quality of life of arthritis patients is correlated positively with perceived health status(r=0.56, p=0.0001), health promoting behavior(r=0.53, p=0.0001), family support (r=0.46, p=0.0001), amount of exercise (r=0.36, p=0.0001), ADL(r=0.36, p=0.0001), HLOC(r=0.32, p=0.0001), frequency of exercise(r=0.32, p=0.0001)in that order, while correlated negatively with the degree of pain felt(r=-0.32, p=0.0001), the number of pain regions(r=-0.19, p= 0.0041), and the duration of pain(r=-0.14, p=0.0279). (3) Regression analysis reveals that the most powerful predictor of the quality of life is perceived health status, which account for 31.11%. The other predictors of the quality of life, which account for 60.22%, are health promoting behavior(16.51%), family support(3.81%), ADL(2.52%), gender(1.86%), the number of family members(1.36%), level of pain(1.24%), duration of pain (1.08%), and level of education(0.67%). The results of the study show that perceived health status and health promoting behavior are the two most important variables. However, considering that the perceived health condition is difficult to control by nursing intervention, it is suggested that the level of expectation for patients, must be decided first, and the health promoting behavior and the family support influencing the quality of life must be taken into account as targets for nursing intervention. As a way of controlling the quality of life, I think that a more comprehensive approach comprising the above important variables along with demographic and general characteristics is needed. I also suggest that we must continue to explore the variables affecting the quality of life and include those variables in nursing intervention.

  • PDF

Circulating Cytokine Levels and Changes During the Treatment in Patients with Active Tuberculosis in Korea (결핵 환자의 치료경과 중 혈청 내 Cytokine 분비와 변화)

  • Ryu, Yon-Ju;Kim, Yun-Jung;Kwon, Jung-Mi;Na, Youn-Ju;Jung, Yu-Jin;Seoh, Ju Young;Cheon, Seon Hee
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.2
    • /
    • pp.140-153
    • /
    • 2003
  • Background : The cell-mediated immune reaction to tuberculosis infection involves a complex network of cytokines. The extent of inflammation, tissue damage and severity of the disease suggested to be determined by the balance between extent and duration of the proinflammatory cytokine response versus those of the suppressive cytokines. The systemic cytokine response in pathogenesis of tuberculosis can be assessed by measuring serum cytokine levels. Method : Serum interleukin-1 beta(IL-$1{\beta}$), IL-2, IL-4, IL-6, IL-10, IL-12(p40), tumor necrosis factor-alpha(TNF-${\alpha}$), interferon-gamma(IFN-${\gamma}$) and transforming growth factor-beta(TGF-${\beta}$) levels were measured in 83 patients with pulmonary tuberculosis, 10 patients with endobronchial tuberculosis before treatment and 20 healthy subjects by using a sandwich ELISA. In patients with pulmonary tuberculosis, they were divided into mild, moderate and far advanced group according to the severity by ATS guidelines. To compare with those of pretreatment levels, we measured serum IL-$1{\beta}$, IL-2, IL-4, IL-6, IL-10, IL-12(p40), TNF-${\alpha}$, IFN-${\gamma}$ and TGF-${\beta}$ levels in 45 of 83 patients with pulmonary tuberculosis after 2 and 6 months of treatment. Results : 1) In sera of patients with active pulmonary tuberculosis(n=83), IL-$1{\beta}$, IL-6(p<0.05), TNF-${\alpha}$, and IFN-${\gamma}$ were elevated and TGF-${\beta}$ was decreased comparing to control. IL-2, Il-12(p40), IL-4 and IL-10 were similar between the patients with tuberculosis and control. 2) In endobronchial tuberculosis, IL-6 and TNF-${\alpha}$ were elevated and TGF-${\beta}$ was decreased comparing to control. IL-12(p40) seemed to be elevated comparing to pulmonary tuberculosis. 3) Far advanced tuberculosis showed markedly elevated IL-6 and IFN-${\gamma}$ level(p<0.05). 4) The significant correlations were noted between IL-1, IL-6 AND TNF-${\alpha}$ and between IL-12, Il-2 and IL-4(p<0.01). 5) After 2 and 6 months of standard treatment, the level of IL-6 and IFN-${\gamma}$ was significantly decreased(p<0.05). Conclusion : These results showed that an altered balance between cytokines is likely to be involved in the extent of inflammation, tissue damage and severity of the disease tuberculosis. But, it should be considered diversities of cytokine response according to type of tuberculosis and immunity in clinical application and interpreting future studies.

Analysis of Residual Solvents of [F-18]FDG Using Gas Chromatography (기체크로마토그래프법을 이용한 [F-18]FDG의 잔류용매 분석)

  • Kim, Dong-Il;Lee, Il-Jung;Kim, Shi-Hwal;Chi, Yong-Gi;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.26-29
    • /
    • 2011
  • Purpose: The general test method of the Korean Pharmacopeia specifies the test method on the clauses of quality control after manufacturing. According to KFDA Guidance for Medicines, standards of residual solvents regulates the maximum permissible dose of acetonitrile as 400 ppm, ethanol as 5,000 ppm, and acetic acid as 5,000 ppm. This study aims at identifying the type of resiual solvents in the final [F-18]FDG vial of an automatic synthesizer and measure its residual quantity. Materials and Methods: The center carried out residual solvents test of [F-18]FDG injection using Agilent Technologies 7890A with a Flame Ionization Detector. The column of Agilent Technologies 7890A used in measuring of residual solvents was CP WAX column ($30m{\times}0.53mm{\times}1.0{\mu}m$) and analysis condition was split mode 1:1 at the initial temperature $70^{\circ}C$ which was increased $20^{\circ}C/minute$ after two minutes and maintained at the final $140^{\circ}C$ for two minutes. The analysis method was as following: Firstly, ethanol-acetonitrile-acetic acid mixture was classified into four types of concentration (250-25-250 ppm, 1,000-100-1,000 ppm, 3,000-300-3,000 ppm, and 6,000-600-6,000 ppm), and $1.0{\mu}L$ of each type of concentration was injected into gas chromatography followed by an analysis of its peak domain. Then, a calibration-curve by the external standard method was drawn based on the analysis result. Results: While ethanol and acetonitrile were detected in TRACERlab MX, FASTlab had additional acetic acid. The residual quantity of the ethanol-acetonitrile-acetic acid mixture evaluated using the calibration-curve was average 72 ppm ethanol, 54 ppm acetonitrile, and 1030 ppm acetic acid for FASTlab, whereas average 439 ppm ethanol and 79 ppm acetonitrile for TRACERlab MX. This indicated that both of them were within the maximum permissible dose. Conclusion: Solvent residues in the [F-18]FDG injection were all within maximum permissible doses and proper to be used to examine a patient. The result indicated that types and quantities of solvent resides of radioactive pharmaceuticals vary depending on the automatic synthesizer.

  • PDF

The Study of Fat Infiltration Ratio in Lumbar Paraspinal Muscle of Patient with Herniated Intervertebral Lumbar Disc (요추간판 수핵 탈출증 환자의 요부 척추 주위근 내 지방침윤 비율에 관한 연구)

  • Kong, Bong-Jun;Lee, Jung-Ho;Yong, Min-Sik;Kim, Jin-Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5254-5260
    • /
    • 2012
  • The purpose of this study is to find the relationship between lumber Herniated Nuclesus Pulposus of specific part and fat infiltration in paraspinal muscle. Also we intended to find the relationship between Body Mass Index(BMI) and fat infiltration ratio in the lumber paraspinal muscle based on the sexes of patients. We conducted this study of patients who visited our hospital from May, 2010 to May, 2012. The subjects are composed of 40 patients(20 females and 20 males), who are 30 to 50 years old suffering from severe lumber herniated nuclesus pulposus, who had or were going to have operation treatment. BMI is measured through anthropometry of each patient and fat infiltration inside the muscle is estimated by measuring the cross section area of lumbar paraspinal muscle from mid-cross section of disc(L2-S1) and fat infiltration ratio. The data of this study are analyzed by independent t-test to figure out the difference of fat infiltration between male and female, and by paired sample T-test after getting mean and standard deviation to find the changes of fat infiltration of lumbar on each level. Also correlation analysis is done by setting age as a control variable to find the correlation between BMI and fat infiltration of the whole lumbar. As a result, we could get only the meaningful difference between the sexes on upper lumber part(L2-L3) while we couldn't find any significant difference in the rest of lumbar(L3-S1). Besides, the changes of fat infiltration ratio on each lumbar level increased rapidly from lumbar 3,4 to lumbar 4,5. We also found that there is no correlation between fat infiltration ratio of lumbar paraspinal muscle(L2-S1) and BMI.

A Study on the Characteristics of Condensable Fine Particles in Flue Gas (배출가스 중 응축성미세먼지 특성 연구)

  • Gong, Buju;Kim, Jonghyeon;Kim, Hyeri;Lee, Sangbo;Kim, Hyungchun;Jo, Jeonghwa;Kim, Jeonghun;Gang, Daeil;Park, Jeong Min;Hong, Jihyung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.5
    • /
    • pp.501-512
    • /
    • 2016
  • The study evaluated methods to measure condensable fine particles in flue gases and measured particulate matter by fuel and material to get precise concentrations and quantities. As a result of the method evaluation, it is required to improve test methods for measuring Condensable Particulate Matter (CPM) emitted after the conventional Filterable Particulate Matter (FPM) measurement process. Relative Standard Deviation (RSD) based on the evaluated analysis process showed that RSD percentages of FPM and CPM were around 27.0~139.5%. As errors in the process of CPM measurement and analysis can be caused while separating and dehydrating organic and inorganic materials from condensed liquid samples, transporting samples, and titrating ammonium hydroxide in the sample, it is required to comply with the exact test procedures. As for characteristics of FPM and CPM concentrations, CPM had about 1.6~63 times higher concentrations than FPM, and CPM caused huge increase in PM mass concentrations. Also, emission concentrations and quantities varied according to the characteristics of each fuel, the size of emitting facilities, operational conditions of emitters, etc. PM in the flue gases mostly consisted of CPM (61~99%), and the result of organic/inorganic component analysis revealed that organic dusts accounted for 30~88%. High-efficiency prevention facilities also had high concentrations of CPM due to large amounts of $NO_x$, and the more fuels, the more inorganic dusts. As a result of comparison between emission coefficients by fuel and the EPA AP-42, FPM had lower result values compared to that in the US materials, and CPM had higher values than FPM. For the emission coefficients of the total PM (FPM+CPM) by industry, that of thermal power stations (bituminous coal) was 71.64 g/ton, and cement manufacturing facility (blended fuels) 18.90 g/ton. In order to estimate emission quantities and coefficients proper to the circumstances of air pollutant-emitting facilities in Korea, measurement data need to be calculated in stages by facility condition according to the CPM measurement method in the study. About 80% of PM in flue gases are CPM, and a half of which are organic dusts that are mostly unknown yet. For effective management and control of PM in flue gases, it is necessary to identify the current conditions through quantitative and qualitative analysis of harmful organic substances, and have more interest in and conduct studies on unknown materials' measurements and behaviors.

Evaluation of Airborne Pb Sources in an Industrialized City by Applying Pb Isotope Ratios and Concentrations in PM10 (PM10 내 납의 동위원소와 농도를 활용한 산업도시지역 대기 중 납 오염원 평가)

  • Jo, Wan-Kuen;Lee, Heon-Chul;Kim, Mo-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.3
    • /
    • pp.174-182
    • /
    • 2011
  • The present study evaluated the major lead sources in a steel metallurgy industrialized city by measuring lead isotopes/lead concentrations of ambient air and potential sources in an industrial area and residential areas according to relative distance. The quality control program obtained during the measurement procedure for lead isotopes and concentrations exhibited $0.5ng/m^3$ for method detection limit, more than 90% for recoveries of standard particulate matters, and lower than 0.2% for reproducibility errors of four lead isotopes ($^{204}Pb$, $^{206}Pb$, $^{207}Pb$, $^{208}Pb$). For all three lead isotope ratios ($^{206}Pb/^{204}Pb$, $^{207}Pb/^{206}Pb$, $^{208}Pb/^{206}Pb$), the ratios were obtained in the industrial area were closer to nearby residential area than those of a residential area far away from the industrial area, thereby suggesting that lead sources were more similar each other in the industrial and nearby residential area. Furthermore, for both summer and winter seasons ambient lead concentrations were more than four times higher in the industrial area than in the residential areas and in turn, they were higher in the nearby residential area compared with the far-away residential area. As a result, it was suggested that lead emitted from the industrial area would influence more the ambient lead in the nearby residential area than the far-away residential area. Both slag and traffic emissions are likely to be major lead sources in the industrial and nearby residential areas, since their three lead isotope ratios ($^{206}Pb/^{204}Pb$, $^{207}Pb/^{206}Pb$, $^{208}Pb/^{206}Pb$) were similar to the ratios obtained from ambient air of these two areas. In addition, the lead isotope ratios revealed different pattern between seasons, and the ambient lead concentrations were higher for winter than for summer.

Effect of Gamma Energy of Positron Emission Radionuclide on X-Ray CT Image (양전자 방출 핵종(18F)의 감마에너지가 X선 CT영상에 미치는 영향)

  • Kim, Gha-Jung;Bae, Seok-Hwan;Kim, Ki-Jin;Oh, Hye-Kyong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.10
    • /
    • pp.4418-4424
    • /
    • 2011
  • This study is aimed to assess the effect of the gamma ray of 511keV energy which is emitted from phantom where the positron emission radionuclide was injected on X-ray CT image. As a scanning method, the CT number and pixel value of the reference image where water was injected(0 mCi), and those acquired by changing the capacity of 18F(Fluorine), positron emission radionuclide, into 1 mCi, 2 mCi, 5 mCi, and 10 mCi were measured. As a result of measuring the CT number(HU) of the phantom image where the positron emission radionuclide($^{18}F$) was injected, there were reference water ($-7.58{\pm}0.66$ HU), 1 mCi($-9.85{\pm}0.50$ HU), 2 mCi($-10.27{\pm}0.21$ HU), 5 mCi($-11.31{\pm}0.66$ HU), and 10 mCi($-13.47{\pm}0.38$ HU). Compared with the image where it was filled with water, there was a reduction of 5.89 Hu in 10 mCi, 3.73 in 5 mCi, 2.69 HU in 2 mCi, and 2 HU in 1 mCi. As for the pixel value of the phantom image, there were reference water ($-2.70{\pm}0.75$), 1 mCi($-4.72{\pm}0.58$), 2 mCi($-6.01{\pm}0.78$), 5 mCi($-6.10{\pm}0.84$), and 10 mCi($-8.20{\pm}0.60$). Compared with the reference image, there was a reduction of 5.50 in 10 mCi, 3.40 in 5 mCi, 3.10 in 2 mCi, and 2.02 in 1 mCi. Through this experiment, it was indicated that, with the increase in the dose of the positron emission radionuclide($^{18}F$), the CT number and the pixel value of the image reduced proportionally, and the width of reduction showed a similar value, too. Accordingly, according to the degree of change in X-ray CT image due to the positron emission radionuclide in the quality control item of PET/CT, the proper standard should be established and it should be periodically managed.

A Comparative Analysis of Blood and Urine Luteinizing Hormone Surge According to Different Regimens of Induced Ovulatory Agens in Superovulated Menstrual Cycles (배란유도방법에 의한 과배란주기에서 혈중및 요중 황체화호르몬 Surge에 관한 연구)

  • Park, Won-Jong;Suh, Byung-Hee;Lee, Jae-Hyun
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.15 no.2
    • /
    • pp.103-117
    • /
    • 1988
  • Ovulation induction was done with 3 different regimens as clomid combined with HMG, HMG only, and FSH combined with HMG in 28 menstrual cycles for IVF-ET and GIFT program. The appearance of endogenous LH surge, estradiol plateau, atypical LH surge, and time from initiation to peak of LH surge in serum and urine were observed and compared in 3 groups. 1. The estradiol concentration of serum LH surge day was similar in three groups but 1st group (Clomiphene Citrate+Sequential HMG) was slightly higher at $1924.0{\pm}865.1\;pg/ml$. In regards to the existence of serum estradiol plateau, 3rd group (FSH+Sequential HMG) was highest at 60%, and 1st group and 2nd group (HMG only) were similar at 33% and 44% respectively. 2. The number of ovarian of ovarian follicle which was more than 18mm in diameter was $4.1{\pm}2.0$, $4.2{\pm}2.1$ respectibely for 2nd group and 3rd group. Although the numbers were slightly higher thean 1st group for each ovarian follicle, serum estradiol value per follicle was higher for 1st group at $583.0{\pm}261.2pg/ml$. 3. When measuring the urine LH surge according to Hi-Gonavi and according to the standard set by three different types of surge, simultameous satisfaction for 1st group, 2nd group, 3rd group was two cases, five cases, four cases respectively at 40%, and the remained cases were composed of numorous type combination which satisfied the two definition, simultaneously in this study, the LH surge starting time was determined only in the cases tow combination were satisfied simultaneously at first, but there are something to study more. In one case of the 3rd group. 4. The concentration of LH surge start in urine and serum of 2nd group was highest at306. $0{\pm}287.2IU/l$ and $34.0{\pm}9.9mIU/ml$ and 1st group was low at $116.6{\pm}66.1IU/l$ and 7.4mIU/ml. The urine and serum value of LH was highest at $1644.4{\pm}988.8IU/l$, $65.9{\pm}15.0mIU/ml$ for 2nd group, 1st group was low at urine, and 3rd group was low of serum. With pregnancy established, the LH concentration of urine was relatively high but on the contrary the LH concentration of serum was low compared to urine concentration. 5. Time from LH surge start to the maximun of urine and serum value was highest at 15. $7{\pm}9.1$ hrs and $10.8{\pm}4.9$ hrs for 1st group and 3rd group. With pregnancy established, time was shortened for urine but on the contrary serum showed an increase in time. 6. The concentration of LH which increases with time on urine was highest at 2nd group ($194.6{\pm}76.8\;IU/hour$). The lowest increase for serum was at 3rd group (2.1mIU/hour). With pregnancy established, urine showed more increase than control group ($266.5{\pm}47.4\;IU/hour$) and for serum there was similar increase ($3.4{\pm}0.8\;mIU/hour$). 7. There were two examples of non-typical surge from 1st group and 3rd group each. Among these three cases showed a reestablishment of LH surge after 10-24 hours. 8. Endogenous spontaneous Lh surge occurs once for each 2nd group and 3rd group.

  • PDF

Food & Nutrition Survey of Specific Areas in Seoul Kores (서울시내 계층별 아파트 주민의 영양실태조사)

  • Kim, S.H.;Chung, C.E.;Lee, H.K.;Cho, S.S.;Lee, Y.W.
    • Journal of Nutrition and Health
    • /
    • v.7 no.2
    • /
    • pp.53-63
    • /
    • 1974
  • For the elucidation of the nutritional status of residences of apartments located in various areas in Seoul city, the food and nutrition survey was undertaken by the graduate students from Department of Food & Nutrition, Ewha Womans University in 1973. The socioeconomic stratification was mainly considered for the selection of sample apartments included in this study. Hangang Mansion, KIST, Munwhachon & Bukahyun apts were selected in this respect. A. Common living circumstances. Through the questionaries, author concluded nutritional concept on everyday food life as follows; 1. Higher income seems less effective in everyday food life on the nutritional view point than higher education does. 2. It needs to be urgently improved to be accustomed to use exact measuring concept of foods when they cook. 3. It needs to be improved to serve meals for individual portion at meal table, because the portion control at meal table will effect to national food policy. B. Nutrition Survey. Average daily calroie intake was the highest in Hangang Mansion and lowest in Bukahyun apt., in accordance with their economic living standard, but most of their calorie intakes were lower than the R.D.A. (3000ca1 for male, 2200 Cal for female). But the composition ratio of the total calorie intake was near to the ideal, carbohydrate 60%, protein 15%, fat 25%. Although there were differences in their economic living situations in urban area, most people ingested relatively good quality and large amounts of protein and fat. Vitamin A and Niacine intake exceeded the R.D.A., but the intake of Ca, Thiamine, Riboflavin, Ascorbic Acid were far less than that of R.D.A. C. food Intake. Amounts of total daily food intake were highest in Bukahyun apt. and lowest in Hangang Mansion. These showed adverse aspects to the total calorie intakes and their income levels. The ratio of cereals, $40%{\sim}50%$ of the total food intake, was higher than any other kinds of foods in all apartments. Among the other foods except cereals, there represented the highest level of meats in Hangang Mansion and KIST apt., while intake of Kimchies were highest in Munwhachon and Bukahyun apt. In the case of vegetables and fruits intake, the ratio of them in Hangang Mansion and KIST apt. were high, on the other hand the ratio of starchy roots appeared lowest in Hangang Mansion. For the main sources of protein, meats were ingested in Hangang Mansion and KIST apt., meats and fishery were used in Munwhachon apt., and beans were eaten highly in their meals in Bukahyun apt. These food contents and distributions showed the significant differences not only their economic classes but also regional characteristics.

  • PDF