• 제목/요약/키워드: Measuring Tube

검색결과 344건 처리시간 0.043초

Thrust - Performance Test of Ethylene-Oxygen Single-Tube Pulse Detonation Rocket

  • Hirano, Masao;Kasahara, Jiro;Matsuo, Akiko;Endo, Takuma;Murakami, Masahide
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.205-210
    • /
    • 2004
  • The pulse detonation engine (PDE) has recently expected as a new aerospace propulsion system. The PDE system has high thermal efficiency because of its constant-volume combustion and its simple tube structure. We measured thrust of single-tube pulse detonation rocket (PDR) by two methods using the PDR-Engineering Model (full scale model) for ground testing. The first involved measuring the displacement of the PDR-EM by laser displacement meter, and the second involved measuring the time-averaged thrust by combining a load cell and a spring-damper system. From these two measurements, we obtained 130.1 N of time-averaged thrust, which corresponds to 321.2 sec of effective specific impulse (ISP). As well, we measured the heat flux in the wall of PDE tubes. The heat flux was approximately 400 ㎾/$m^2$. We constructed the PDR-Flight Mode] (PDR-FM). In the vertical flight test in a laboratory, the PDR-FM was flying and keeping its altitude almost constant during 0.3 sec.

  • PDF

비정상유동장에서 모세관점도계의 점도측정 (Viscosity Measurement in the Capillary Tube Viscometer under Unsteady Flow)

  • 박흥준;유상신;서상호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.825-828
    • /
    • 2000
  • The objective of the present study is to develop a new device that the viscous characteristics of fluids are determined by applying the unsteady flow concept to the traditional capillary tube viscometer. The capillary tube viscometer consists of a small cylindrical reservoir, capillary tube, a load celt system oat measures the mass flow rate, interfacers, and computer. Due to the small size of the reservoir the height of liquid in the reservoir decreases as soon as the liquid in the reservoir drains out through the capillary and the mass flow rate in the capillary decreases as the hydrostatic pressure in the reservoir decreases resulting in a decrease of the shear rate in the capillary tube. The instantaneous shear rate and. driving force in the capillary tube are determined by measuring the mass flow rate through the capillary, and the fluid viscosity is determined from the measured flow rate and the driving force.

  • PDF

폐회로 습도계를 이용한 수증기 플럭스 관측시관의 감쇠 효과에 관하여 (On the Effect of Tube Attenuation on Measuring Water Vapor Flux Using a Closed-path Hygrometer)

  • 홍진규;김준;최태진;윤진일
    • 한국농림기상학회지
    • /
    • 제2권3호
    • /
    • pp.80-86
    • /
    • 2000
  • 에디 공분산 방법은 생태계와 대기간의 질량과 에너지 교환을 측정하는데 널리 사용되고 있다. 이 방법은 다른 미기상학적 방법과는 달리 많은 가정을 필요로 하지 않는 직접 측정으로서, 스칼라의 농도 변화를 측정하기 위해 고속 반응의 개회로 또는 폐회로 기기를 필요로 한다. 후자를 사용할 경우, 흡입된 공기가 관을 통과하면서 스칼라의 농도 변동의 감쇠가 일어난다. 이러한 관 감쇠 효과는 측정하고자 하는 난류 플럭스를 과소 평가하게 한다. 난류 흐름의 감쇠 효과를 정량화하기 위해서 개회로 기기와 폐회로 기기로 측정된 수증기 농도를 각각 분석하였다. 통계적 분석에 의하면, 폐회로 기기에서 얻어진 스펙트럼이 0.5 Hz 이상의 영역에서 개회로 기기에서 얻어진 스펙트럼과 서로 다름을 보였다. 낮에는 관 감쇠에 의한 수증기 플럭스의 손실이 5% 이내였으나, 밤에는 풍속이 작고, 난류의 강도가 약하여 플럭스 손실이 상대적으로 크게 나타났다. 이론적으로 계산된 플럭스 손실은 관측 결과와 고주파수 영역에서 약간의 차이를 보였는데, 이것은 수증기가 관의 벽과 상호 작용하면서 플럭스 측정에 영향을 주었기 때문인 것으로 추정된다. 결론적으로, 개회로나 폐회로기기 모두 5% 오차 내에서 수증기 플럭스 관측에 사용할 수 있다. 그러나 대기가 안정할 때는 플럭스 산출시 고주파수에서의 영향을 신중히 고려해 주어야 한다.

  • PDF

Comparison of Analysis Methods for Ammonia from Swine Production Facilities

  • Kim, Ki Y.;Choi, Hong L.;Kim, Chi N.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제17권11호
    • /
    • pp.1608-1614
    • /
    • 2004
  • This study was performed to evaluate the accuracy, validation and applicability of UV spectrophotometer (UV), Ion Chromatography (IC), and Detector tube (DT) methods for measuring ammonia (NH3) concentration in a swine confinement house and swine slurry storage tank. The mean values of $NH_{3}$ emitted from the house and slurry were 5.333 ppm and 42.192 ppm for the IC method; 4.13 ppm and 36.29 ppm for the Detector tube; and 5.417 ppm and 34.193 ppm for the UV method. The accuracy and the correlation of an ammonia level analyzed by the IC method compared to the UV method were 98% and 0.998($R^{2}$) in the swine confinement house and 94% and 0.997($R^{2}$) in the swine slurry storage tank. On the other hand, those of ammonia level measured by the Detector tube compared to the UV method were 77% and 0.957($R^{2}$) in the swine confinement house and 82% and 0.941($R^{2}$) in the swine slurry storage tank. This indicated that the accuracy and the correlation of the IC method compared to the UV method were higher than those of the Detector tube method compared to the UV method. Therefore, it was concluded that the IC method was more accurate in measuring ammonia concentration in a swine house and a swine slurry storage tank. The Detector tube method should not be applied to the swine slurry storage tank in which ammonia concentration is generally higher than 30 ppm because low accuracy is caused by a gross space between scales inscribed in the Detector tube.

A Study on the Crevice Corrosion for Ferritic Stainless Steel by Micro Capillary Tube Method

  • Na Eun-Young;Ko Jae-Yong;Baik Shin-Young
    • 전기화학회지
    • /
    • 제7권4호
    • /
    • pp.179-182
    • /
    • 2004
  • The aim of this study is to investigate the initiation and propagation of crevice corrosion for ferritic stainless steel in artificial crevice based on micro capillary tube method. The 430 stainless steel in artificial crevice is potentiostatically polarized in different sodium chloride solutions. Potentiodynamic and potentiostatic polarization data were measured in situ. The potentials in the crevice were measured by depth profile using the 0.04 mm diameter micro capillary tube inserted in the crevice. The potentials in the crevice ranged from -220 mV to -360 mV vs SCE from opening to bottom of crevice, which are lower than the external surface potential, -200 mV vs SCE. Such a potential drop induced the change of the metal surface state from passive to active. The surface of metal is located in passive state in -200 mV but the inner surface keeps active state below -220 mV, Thus these results show that the It drop mechanism in the crevice was more objective for evaluation and the method was easier to reproduce. Therefore the potential drop is one of the reasons for crevice corrosion by measuring the potentials in narrow crevice with a new micro measuring system.

MF증발기 기초 형상 설계에 관한 연구 (A Study on the Basic Shape of an MF Evaporator)

  • 박용석;성홍석;서정세
    • 한국기계가공학회지
    • /
    • 제18권6호
    • /
    • pp.39-44
    • /
    • 2019
  • The evaporator is a key driver of an air conditioning system's efficiency. In this study, we study methods of maximizing the efficiency of a Massey Ferguson (MF) evaporator by measuring how the cooling performance of different shapes vary with temperature. We varied the tube insertion depth as well as the shape of the evaporator's header and tube. When we compare header shapes of "D", "Ellipse", and "Quadrangle" types, we find that the elliptical header creates the smallest pressure loss and the highest temperature difference. Between tube shapes of "Rectangular", "Projection", and "Circular" types, the "Projection" type tube creates the most temperature difference. We also investigated the depth of tube insertion in the header and find that tube insertion of 5 - 10 mm is feasible; we selected the depths of 5, 7, and 10 mm since they corresponded to approximately 30%, 50%, and 70% of the total width of the header. The tube insertion test demonstrated that a tube insertion depth of 7 mm creates the least pressure loss and the highest temperature difference. In conclusion, the optimal evaporator design uses an "Ellipse" type header, "Projection" type tube, and a tube insertion depth between 30 and 50% of the header width.

열식 질량 유량계 센서관의 과도 특성에 관한 연구 (Study on the Transient Characteristics of the Sensor Tube of a Thermal Mass Flow Meter)

  • 김동권;한일영;김성진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.308-313
    • /
    • 2003
  • Thermal mass flow meters (TMFMs) are most widely used for measuring mass flow rates in the semiconductor industry. A TMFM should have a short response time in order to measure the time-varying flow rate rapidly and accurately. Therefore it is important to study transient heat transfer phenomena in the sensor tube of a TMFM that is the most critical part in the TMFM. In the present work, a simple numerical model for transient heat transfer phenomena of the sensor tube of a TMFM is presented. Numerical solutions for the tube and fluid temperatures in a transient state are obtained using the proposed model and compared with experimental results to validate the proposed model. Based on numerical solutions, heat transfer mechanism in a transient state in the sensor tube is explained. Finally, a correlation for predicting the response time of a sensor tube is presented. The correlation is verified by experimental results.

  • PDF

Simulation and Analysis of ECT Signals Obtained at Tubesheet and Tube Expansion Area

  • Song, Sung-Chul;Lee, Yun-Tai;Jung, Hee-Sung;Shin, Young-Kil
    • 비파괴검사학회지
    • /
    • 제26권3호
    • /
    • pp.174-180
    • /
    • 2006
  • Steam generator (SG) tubes are expanded inside tubesheet holes by using explosive or hydraulic methods to be fixed in a tubesheet. In the tube expansion process, it is important to minimize the crevice gap between expanded tube and tube sheet. In this paper, absolute and differential signals are computed by a numerical method for several different locations of tube expansion inside and outside a tubesheet and signal variations due to tubesheet, tube expansion and operating frequencies are observed. Results show that low frequency is good for detecting tubesheet location in both types of signals and high frequency is suitable for sizing of tube diameter as well as the detection of transition region. Also learned is that the absolute signal is good for measuring tube diameter, while the differential signal is good for locating the top of tubesheet and both ends of the transition region. In the case of mingled anomaly with tube expansion and tubesheet, low frequency inspection is found to be useful to analyze the mixed signal.

토마토 펄라이트 베드재배시 배액전극 제어법에 적합한 측정틀 설계 (Design of Measuring Trays in the Irrigation System Using Drainage Electrodes for Tomato Perlite Bed Culture)

  • 김성은;김영식;심상연
    • 원예과학기술지
    • /
    • 제29권6호
    • /
    • pp.568-574
    • /
    • 2011
  • 토마토 펄라이트 베드재배에서 급액방법으로 배액전극 제어법을 적용하기 위한 적정 측정틀 개발을 위해 본 실험이 수행되었다. 작물로는 대과종 토마토를 사용하였고, 재배 방법은 자루재배와 동일하게 적용하였으며, 급액제어 방법으로 배액전극 제어법을 적용한 다섯 가지 측정틀 처리와 타이머 제어법을 적용한 한 가지 측정틀 처리를 대조구로 하였다. 1차 실험에서는 배지의 수분함량 안정성 조사로 가장 불안정한 Tube-2 처리를 제외하였고, 2차 실험에서는 배지의 수분함량 안정성과 생육과 수확량을 조사하여 성적이 가장 나빴던 Tube-1 처리를 제외하였다. 3차 실험에서 배지의 수분함량 안정성과 생육 및 수확량에서 우수하였으며, WUE와 FUE가 가장 높았던 Up-Board 처리를 선택하였다. Up-Board 처리는 여섯 가지 처리 중에서 가장 경제적이며 측정틀 제작도 용이하여 베드충진 방식에서 배액전극 제어법을 적용하기에 가장 우수한 측정틀 설계였다.

퍼지탐색을 이용한 머신비전 기반의 소형 튜브 내경측정 알고리즘 (Radius-Measuring Algorithm for Small Tubes Based on Machine Vision using Fuzzy Searching Method)

  • ;이상진;김형석;배용환;이병룡
    • 대한기계학회논문집A
    • /
    • 제35권11호
    • /
    • pp.1429-1436
    • /
    • 2011
  • 본 논문에서는 튜브의 내부에 이물질이 있거나, 조명에 의한 영상잡음이 많은 경우에도 내경중심과 내경을 정확하게 측정할 수 있는 머신비전 기반의 새로운 측정알고리즘을 제안하였다. 또한 내경과 외경 중심간의 이격거리인 편심량도 계산할 수 있다. 제안된 알고리즘은 퍼지제어에 바탕을 둔 반복탐색에 의하여 임의의 초기탐색점에서 거리와 방향을 단계적으로 이동함으로써 내경의 중심에 도달하게 한다. 제안된 알고리즘은 계산시간 뿐만 아니라 측정정밀도 면에도 기존의 방법에 비해 우수하였다. 성능을 비교하기 위하여 생산현장에서 생산되는 튜브들을 이용하여 실험을 수행하였고, 실험 결과 제안된 알고리즘을 사용하는 경우가 널리 사용되고 있는 알고리즘인 Hough 변환 방식과 RANSAC 방식보다 계산시간 및 측정정밀도에서 우수함을 보였다.