• Title/Summary/Keyword: Measuring Gap

Search Result 386, Processing Time 0.023 seconds

Characteristics of Fluid Force Reduction for Two Different Square Prisms in a Tandem Arrangement (직렬배열에 놓인 크기가 다른 정방형주의 유체력 저감특성)

  • Ro, Ki Deok;Kang, Chang Whan;Park, Kwon Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.7
    • /
    • pp.435-443
    • /
    • 2017
  • The Characteristics of the flowfields of a square prism having a small square prism were investigated by measuring of lift and drag on the square prism and visualizing the flowfield using PIV. The experimental parameters were the width ratios(H/B=0.2~0.6) of small square prisms to the prism width and the gap ratios (G/B=0~3) between the prism and the small square prism. The drag reduction rate of the square prism initially increased and then decreased with the G/B ratio for the same H/B ratio, and increased with the H/B ratio for the same G/B ratio. The maximum drag reduction rate of 98.0% was observed at H/B=0.6 and G/B=1.0. The lift reduction rate of the square prism was not affected by the width and gap ratios; the total average value was approximately 66.5%. In case of a square prism having a small square prism, the stagnation regions were represented in the upstream and downstream sides of the square prism.

Photoacoustic Investigation of Carrier Transport and Thermal Diffusivity in GaAs and Si (광음향분광법을 이용한 GaAs와 Si 반도체의 열확산도 측정과 운반자특성 연구)

  • Lim, Jong Tae;Han, Ho Youn;Park, Seung Han;Kim, Ung;Choi, Joong Gill
    • Journal of the Korean Chemical Society
    • /
    • v.41 no.7
    • /
    • pp.329-336
    • /
    • 1997
  • Photoacoustic spectroscopy was utilized to investigate the carrier transport and the thermal diffusivity in GaAs and Si. From the frequency dependence of the photoacoustic signal, it is found that heat source was originated from the instantaneous thermalization process in low frequency region. In high frequency region, however, the heat was generated by the nonradiative bulk recombination and the nonradiative surface recombination processes. It was also shown that the photoacoustic effects in GaAs of a direct band gap were governed by all three processes and those in Si of an indirect band gap were produced by the instantaneous thermalization and the nonradiative bulk recombination only. The phase of the photoacoustic signal showed a minimum value in GaAs. In Si, the phase of the photoacoustic signal was monotonically decreased as the modulation frequency was increased, demonstrating the above-mentioned mechanisms of the generation of heat. By measuring the photoacoustic signal, thermal diffusivities of semiconductors were determined to be ∼0.35 ㎠/s for GaAs and ∼1.24 ㎠/s for Si. In addition, the similar values of thermal diffusivities were obtained from the curve fitting of photoacoustic phase spectra.

  • PDF

The Scale Development of Consumer's Charity Impulse : Focusing on Donation Behavior toward Non-profit Organization (소비자의 자선적 충동에 관한 측정도구의 개발 - 비영리단체에 대한 기부행위를 중심으로 -)

  • Ock, Jung-Won;Seo, Hae-Jin
    • Management & Information Systems Review
    • /
    • v.33 no.3
    • /
    • pp.1-19
    • /
    • 2014
  • Main research question of this study is based on situational gap between donation motivation and behaviour in non-profit organization. However, researches investigating the gap were limited. Therefore, this study examined components of psychological variables. Specially, we proposed the variables about consumer's impulsive motivation or behavior on impulse literature in donation toward non-profit organization. This study conducted a scale development to measure consumer's charity donation impulse based on non-conscious viewpoint. For the development of measurement tool for charity donation impulse, we conducted two stages of research process. First, the measurement items of charity donation impulse were developed through FGI and in-depth interview on experts. Secondly, the factor analysis was performed, and then some items were eliminated through this analysis. As a result, we found the final scale with 26 items, which were named as evaluation sensitivity charity impulse, reward sensitivity charity impulse, functional impulse, non-planning charity impulse. These results showed that the measurement items developed in this study were confirmed to be useful tools for measuring charity donation impulse.

  • PDF

THE SHEAR BOND STRENGTH BETWEEN DICOR AND SEVERAL VENEERING PORCELAINS (Dicor와 수종 전장도재간의 전단결합강도)

  • Ryoo, Kyung-Hee;Lee, Sun-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.2
    • /
    • pp.165-179
    • /
    • 1993
  • Dicor has not been prescribed routinely, in spite of many advantages, because of esthetic limitations by excessive translucency and external shading. In an attempt to solve these problems, the technique of veneering Dicor by aluminous poreclain has been used and recently Dicor Plus system was developed. The purpose of this study was to evaluate the compatibility between Dicor and several veneering porcelains by measuring the shear bond strength and observing the failure mode and interface appearance with SEM. Total 55 Dicor disks(10.0mm diam. X 3.0mm thickness) were fabricated by lost wax technique and divided into five groups of 11. Veneering porcelains such as Dicor Plus, Vitadur Alpha, Vitadur N, Vivodent, and Ceramco II were built up over the center of the treated Dicor surface using paper tube(5.0mm diam. X 4.0mm height) and fired according to the manufacturesr’instructions. A representative sample from each group was completely embedded in epoxy resin and crosssectioned, and remaining 50 samples were embedded in epoxy resin with the bonded area perpendicular to table base. The shear bond strengths were measured by applying the shear load parallel to Dicor surface close to the bonded area. Failure modes and interface appearances were observed using SEM at 15 and 1000 magnification respectively. The obtained results were as follows : 1. The mean shear bond strengths showed Dicor-Dicor Plus(10.53 MPa); Dicor-Vitadur Alpha(8.84 MPa); Dicor-Vitadur N(7.37 MPa); Dicor-Vivodent(4.28 MPa); Dicor-Ceramco II(0.89 MPa). 2. The shear bond strength of Dicor-CeramcoII was significantly decreased compared with Dicor-Dicor Plus(p<0.01), but had no significant difference compared with Dicor-Vivodent(p>0.01). 3. The shear bond strengths of Dicor-Vitadur Alpha and Dicor-Vitadur N were not significantly different compared with Dicor-Dicor Plus(p>0.01). 4. SEM examination of bond failure modes revealed that Dicor-Dicor plus, Dicor-Vitadur Alpha, Dicor-Vitadur N exhibited cohesive failure within Dicor and Dicor-Vivodent exhibited adhesive failure. And Dicor-Ceramco III exhibited adhesive failure and cohesive failure within CeramcoIII together. 5. SEM examination of interfaces revealed that Dicor-Dicor Plus exhibited the most tight contact and Dicor-Vitadur Alpha, Dicor-Vitadur N exhibited acceptible contacts. But Vivodent exhibited discontinuous gap and Ceramco II exhibited large continuous gap.

  • PDF

The sealing Characteristics of sealing glasses and Mn-Zn single crystal ferrite (봉착용 유리와 Mn-Zn 단결정 Ferrite와의 봉착특성에 관한 연구)

  • Yun, Seong-Gi;Han, Joong-Hee;Gang, Won-Ho
    • Korean Journal of Materials Research
    • /
    • v.1 no.4
    • /
    • pp.221-228
    • /
    • 1991
  • In this study we have investigated the sealing characteristics of glasses suitable for producing the magnetic gap of the ferrite head cores which have been widely used for VTR and computer magnetic heads. $PbO-B_2O_3$ g1asses were evaluated by measuring microhardness, thermal expansion coefficient and sliding wear resistance. Concentration distribution of elements at the interface was observed by WDS. wettability was measured by high temperature microscopy. The results were as follows ; 1. In sealing glasses of $PbO-B_2O_3$ system, thermal expansion coefficient and wear volume were increased with increasing PbO content, and were decreased with increasing $B_2O_3$ content. 2. The contact angle of $PbO-B_2O_3$ Systems was mainly influenced by PbO content. 3. The sealing temperature showed a tendency to decrease proportionally with the increase of the coefficient of thermal expansion. 4. The diffusion at the interface between Mn-Zn single crystal ferrite and sealing glasses of $PbO-B_2O_3$ system was dominated by small amount of diffusion of ferrite content into glass part, which was very little affected by sealing heat treatment time.

  • PDF

THE STUDY ABOUT THE MARGINAL FIT OF THE CASTING TITANIUM AND MACHINE-MILLED TITANIUM COPINGS (주조티타늄과 기계절삭티타늄 코핑의 변연적합성에 관한 연구)

  • Oh Su-Yeon;Vang Mong-Sook;Yang Hong-So;Park Sang-Won;Park Ha-Ok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.1
    • /
    • pp.20-28
    • /
    • 2006
  • Statement of problem: The titanium has advantages of a high biocompatibility, a corrosion resistence, low density, and cheep price, so it is focused as a substituted alloy But it is quite difficult to cast with the tranditional method due to the high melting point, reacivity with element at, elevated temperature. By using the CAD-CAM system for the crown construction, it is possible to reduce the errors while proceeding the wax-up, investing, and casting procedure Purpose: The purposes of this study were to measure the marginal adaptation of the casting titanium coping and machine-milled titanium coping according to the casting methods and the marginal configurations. Material and method: The marginal configurations were used chamfer shoulder, and beveled shoulder. The total 30 copings were used, and these are divided into 6 groups according to the manufacturing method and marginal configuration. The gap between margin of the model and the restoration was measured with 3-dimensional measuring microscope. Results: The following results were obtained; 1. casting gold coping demonstrated the best marginal seal, followed by casting titanium coping finally machine-milled titanium copings. 2. In casting titanium coping, chamfer demonstrated the best marginal seal, followed by shoulder and beveled shoulder. There was no significantly difference in shoulder and beveled shoulder. But all margin form has clinically acceptable 3. In machine-milled titanium copings, chamfer demonstrated the best marginal seal, followed by shoulder and beveled shoulder. Beveled shoulder show large and uneven marginal gap Conclusions: Above result revealed that marginal adaptation of the titanim coping is avail able in the clinical range, it can be used as an alternative metal and it is prefered especially in chamfer or shoulder margin during implant superstructure fabrication. But there should be more research on machine-milled titanium in order to use it in the clinics.

THE FIT OF ZIRCONIA FORE FABRICATED WITH CAD/CAM SYSTEM (CAD/CAM system으로 제작한 zirconia core의 적합도)

  • Seong Ji-Yun;Jeon Young-Chan;Jeong Chang-Mo;Lim Jang-Seop
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.5
    • /
    • pp.489-500
    • /
    • 2004
  • Statement of problem: The use of zirconia prostheses fabricated with CAD/CAM system is on an increasing trend in dentistry. However, evaluation of the fit related to internal relief and marginal reproducibility of zirconia has not been reported. Purpose : This study was to evaluate the fit related to internal relief and marginal reproducibility of zirconia core fabricated with CAD/CAM system. Materials and methods: The evaluation was based on 30 zirconia cores and 5 IPS-Empress2 cores. Zirconia cores were fabricated in different conditions of internal relief(0, 10, 20, 30, 40 and $50{\mu}m$), and IPS-Empress2 cores were fabricated in accordance with the manufacturer's instructions. Before cementation, the marginal discrepancies or cores were measured on metal die. And then, each core was cemented to stone die, embedded in an acrylic resin and sectioned in two planes(mesiodistally and labiopalatally). The internal gaps were measured at the margin and axial surface. Measurements for the marginal discrepancies, the internal marginal gaps and the internal axial gaps were performed under a measuring microscope(Compact measuring microscope STM5; Olympus, Japan) at a magnification of ${\times}100$. In addition, the marginal conagurations of metal die, zirconia core and IPS-Empress2 core were examined with SEM(S-2700, Hitachi, Japan). Results : Within the limits of this study the results were as follows. 1. Compared with IPS-Empress2 cores, the marginal discrepancies of zirconia cores had no significant differences. the internal marginal gaps were statistically smaller and the internal axial gaps were statistically larger in each condition of internal relief. 2. The marginal discrepancies and the internal marginal gaps of zirconia cores had no significant differences related to the conditions of internal relief(P>0.05). 3. The internal axial gaps of zirconia cores with $0{\sim}20{\mu}$m for internal relief were significantly larger than that with $50{\mu}m$ (P<(0.0001). 4. SEM micrographs showed favorable marginal reproducibility of zirconia core and smooth texture on the milling surface. Conclusion: The marginal discrepancy and the internal gaps of zirconia core were clinically acceptable and the milling surface was showed smooth texture. For fabrication of the durable esthetic restoration, further investigations on complex design of core, milling accuracy, compatability of enamel porcelain and porcelain firing seems to be needed.

University Enrollment Policy in the Capital Region and Its Impact on Population Dispersal (수도권 대학정원정책의 수동권 인구분산교과에 관한 연구)

  • 임창호;구자훈;안근원
    • Journal of the Korean Regional Science Association
    • /
    • v.9 no.1
    • /
    • pp.45-63
    • /
    • 1993
  • University enrollment has long been regarded as one of the major factors inducing population concentration in Seoul and the Capital Region of Korea. Consequently, since early 1980's increases in enrollment and new establishments of extention universities beyond the boundary of Seoul, has been promoted, while university enrollment quota in Seoul has been strictly controlled. The degree of actual population dispersal, however, resulting from such a university enrollment policy has not been empirically tested. This paper aims at: First, identifying the trend of population growth and evolution process of the university enrollment policy in the Capital Region; Second, comparing the degree of influence of university enrollment on population concetration factors; Third, measuring actual effect of the enrollment control on population dispersal out of Seoul and the Capital Region. Major findings are as follows: First, only a week correlation between population and university enrollment growth trends was found; Second, the relative degree of influence on population concentration in the Capital Region, were order, in the order of magnitude, the physical amenity factor, the socio-cultural amenity factor, the employment climate factor and the educational factor. Third, and most improtant, based on the comparison of spatial distribution of graduated high schools and current residence of the selected university students, the gap between the two distributions was revealed and the inter-regional student population movement was estimated. The result shows that in Seoul's case about one-half of and in Kyunggi Province's case about one-fifth of university enrollment size, contributes to population concentration into Seoul. Fourth, as to the universities outside of the Capital Region, little effect in the case of universities located within the commuting distance, and a little effect on population dispersal in the case of universities located beyond commuting distance, were found. In sum, it seems clear that university enrollment policy in the Capital Region, especially in Inchon/Kyunggi Province has not been effective on student population dispersal out of Seoul and the Capital Region. Therefore, it is strongly recommended that university enrollment policy be throughly re-examined from its goal to the implementation means.

  • PDF

Experiments on the flow field of a circular cylinder having a front vertical plate (정면에 수직평판을 가진 원주의 유동장 특성실험)

  • Ro, Ki-Deok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.198-204
    • /
    • 2016
  • The characteristics of the flow field of a circular cylinder having a small vertical plate at the upstream side are investigated by measuring the fluid force on the circular cylinder and by visualizing the flow field using particle image velocimetry. The experimental parameters are the width ratios (H/B = 0.2-0.6) of the vertical plates to the circular cylinder's diameter, and the gap ratios (G/B = 0-3) between the circular cylinder and the vertical plate. The drag reduction rate and Strouhal number of the circular cylinder increased and then decreased with G/B in the case of the same H/B. The drag reduction rate increased with H/B in the case of the same G/B. In the case of a circular cylinder having a small vertical plate, the stagnation regions are represented on the upstream and downstream sides of the circular cylinder, and the size of that region on the upstream side increased with H/B.

Overview of the Development of the Korean Exposure Factors Handbook

  • Jang, Jae-Yeon;Jo, Soo-Nam;Kim, So-Yeon;Myung, Hyung-Nam
    • Journal of Preventive Medicine and Public Health
    • /
    • v.47 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • A set of exposure factors that reflects the characteristics of individual behavior capable of influencing exposure is essential for risk and exposure assessment. In 2007, the Korean Exposure Factors Handbook was, therefore, issued, driven by the need to develop reliable exposure factors representing the Korean population. The purpose of this study was to overview the development process of the Korean Exposure Factors Handbook and major recommended exposure values for the Korean population to allow information exchanges and comparison of recommended values among nations. The researchers reviewed the domestic data that could be used in the development of exposure factors, confirmed a knowledge gap, and set a priority of development by phases. A methodology to measure exposure factors was established to develop measuring techniques and test their validity. Data were processed or a survey was conducted according to the availability of data. The study thus produced recommended values for 24 exposure factors grouped by general exposure factors, food ingestion factors, and activity factors by setting up a database of exposure factors and carrying out statistical analysis. The study has significantly contributed to reducing the potential uncertainty of the risk and exposure assessment derived by the application of foreign data or research findings lacking representativeness or grounds by developing a set of exposure factors reflecting the characteristics of the Korean people. It will be necessary to conduct revisions in light of the changing statistical values of national data and the exposure factors based on Korean characteristics.