• Title/Summary/Keyword: Measurement validation

Search Result 702, Processing Time 0.03 seconds

Vitellogenin ELISA System Based on Monoclonal and Polyclonal Antibodies against Vitellin of Floating Goby (Chaenogobius annularis) (꾹저구(Chaenogobius annularis)의 난황단백질에 대한 다클론 항체와 단글론 항체을 이용한 Vitellogenin ELISA System)

  • Kang, Bong-Jung;Jung, Jee-Hyun;Lee, Je-Yong;Kim, Myung-Hee;Han, Chang-Hee
    • Development and Reproduction
    • /
    • v.9 no.2
    • /
    • pp.135-142
    • /
    • 2005
  • Vitellogenins(VTGs) are the precursor of egg-yolk proteins in most oviparous species from invertebrates to vertebrates. In oviparose vertebrates, VTGs are synthesized in the liver and transported through the blood to oocytes. In female fish, concentrations of plasma VTG increase rapidly at onset of vitellogenesis in the normal reproductive cycle. Male fishes also possess the gene for VTG, but plasma concentrations of the protein typically remain small, presumably due to low levels of endogenous estrogens. However, exposure of males to exogenous estrogenic mimics can result elevated. Therefore, the VTG in fish can be used as a useful biomarker for appropriate tools of endocrine disrupting compounds effects. In this studies, we prepared the test methods that can measure the plasma VTG level in the gobies that live in polluted area with mimic estrogen. For the purpose, we purified VTG of floating goby(Chaenogobius annularis) and prepared specific monoclonal and polyclonal antisera to yolk protein, then developed a sandwich competitive ELISA system for measurement of plasma VTG levels. Validation for the ELISA system using monoclonal and polyclonal antibodies against VTG was tested. The absorbance curve of serial dilutions of serum from vitellogenic female was paralleled to the standard curve of VTG, but normal male was not paralleled. The developed sandwich ELISA system was measured for VTG levels in plasma of common goby(Acanthogobius flaviman) and javeline goby(A. hasta) as well as in plasma of floating goby(C. annularis).

  • PDF

Quantitative Analysis of Contents of Vegetable Oils in Sesame Oils by NIRS (근적외선분광광도법을 이용한 참기름중 이종식용유지 정량법에 관한 연구)

  • Kim, Jae-Kwan;Kim, Jong-Chan;Ko, Hoan-Uck;Lee, Jung-Bock;Kim, Young-Sug;Park, Yong-Bae;Lee, Myung-Jin;Kim, Myung-Gil;Kim, Kyung-A;Park, Eun-Mi
    • Journal of Food Hygiene and Safety
    • /
    • v.22 no.4
    • /
    • pp.257-267
    • /
    • 2007
  • The possibility of rapid non-destructive qualitative and quantitative analysis of vegetable oils such as perilla, com, soybean and rapaseed oils in sesame oils was evaluated. A calibration equation calculated by MPLS(Modified Partial Least Squares) regression technique was developed and coefficients of determination for perilla oil, com oil, soybean oil and rapaseed oil contents were 0.9992, 0.9694, 0.9795 and 0.9790 respectively. According to the data obtained from validation study, $R^2$ of contents of perilla, com, soybean, rapaseed oils were 0.997, 0.848, 0.957 and 0.968, and SEP of content of them 0.747, 5.069, 3.063 and 3.000 by MPLS respectively. The results indicate that the NIRS procedure can potentially be used as a non-destructive analysis method for the rapid and simple measurement of sesame oil mixed with other vegetable oils. The detection limits of the NIRS for perilla oil, com oil, soybean oil and rapaseed oil were presumed as 2%, $15{\sim}20%,\;15{\sim}20%$ and 10%, respectively.

Identifying Genes Related with Radiation Resistance in Oral Squamous Cell Carcinoma Cell Lines (두경부 편평상피세포암주에서 방사선 내성 관련 유전인자의 확인)

  • Lee, Sei-Young;Seol, Jeong-Hun;Park, Haeng-Ran;Cho, Nam-Hoon;Choi, Yoon-Pyo;Rha, Sun-Young;Baek, Seung-Jae;Hwang, Jun-Yeon;Kim, Se-Heon
    • Korean Journal of Head & Neck Oncology
    • /
    • v.27 no.2
    • /
    • pp.190-197
    • /
    • 2011
  • Background and Objective : Radiation resistance(RR) is one of main determinants of treatment outcome in oral squamous cell carcinoma(OSCC), but accurate prediction of RR is difficult. We aim to establish RR OSCC cell lines and identify genes related with RR by a measurement of altered gene expression after inducing RR. Material and Methods : OSCC cell lines, SCC15, SCC25 and QLL1, were treated with 2Gy radiation per session, and parts of them were alive in finally accumulated dosage of 60Gy through 30 times repetition of radiotherapy for inducing RR cell lines. We compared results of cDNA array and proteomics in non-radiated cell lines and RR cell lines to detect changes of gene expression. Western blot was used for the validation of results. Results : cDNA array revealed 265 commonly up-regulated genes and 268 commonly down-regulated genes in 3 RR cell lines comparing their non-radiated counterpart. Among them, 30 cancer related genes were obtained. Proteomics showed 51 commonly altered protein expressions in 3 RR cell lines and 18 cancer related proteins were obtained. Among the detected genes, we found NM23-H1 and PA2G4 were over-expressed in both cDNA array and proteomics. Western blot showed increased expression of NME1 in RR cell lines but not in PA2G4. Conclusion: We concluded that NM23-H1 may be a candidate of RR related gene and over-expression of NM23-H1 could be a biomarker to predict RR in OSCC.

Development of Nursing Activity Cost Calculation Program Using Time-Driven Activity-Based Costing (TD-ABC) (병동 간호활동 원가계산 프로그램 개발 :시간동인 활동기준원가계산 기반으로)

  • Lim, Ji Young;Kang, Sung Bae;Lee, Hyun Hee
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.4
    • /
    • pp.480-494
    • /
    • 2018
  • The purpose of this study is to develop a nursing activity cost calculation program based on Lee's doctoral dissertation using TD-ABC. The developed program has been supplemented with data storage, print out, and graph conversion functions to expand the application possibility. The development of the program consisted of three steps: program requirements analysis, program design and development, and program validation. This program was designed not only to do the cost calculation, but also to compare the cost-effectiveness and cost consumption trends. Consequently, this program is meaningful in that the nursing manager can obtain the cost information necessary for nursing unit management and extend the utilization so that the cost management strategy can be established based on the cost information. Therefore, we propose that the cost-management capacity of clinical nurses should be strengthened and the nursing performance measurement research should be expanded by applying it to various actual clinical nursing management settings. It is suggested that this program should be used as a training medium to strengthen nurse cost management capacity by combining nursing management curriculum at undergraduate level.

Antecedents and Consequences of Supplier's fairness perception (중소공급업체 공정성 지각의 선행요인과 결과요인)

  • Kim, Do-Heon;Kim, Sang-Deok
    • Journal of Distribution Science
    • /
    • v.9 no.2
    • /
    • pp.61-72
    • /
    • 2011
  • The object of this research is to examine the factors leading to intercompany win-win by finding the antecedents and consequences that affect a supplier's fairness perception. We assume that the antecedent factors of a supplier's fairness perception are vertical coordination, cooperation support, information sharing, and legalistic plea. We assume that the consequential factors of a supplier's fairness perception are supply chain dependence and supply chain flexibility. The object industry is an electronic parts manufacturing company. We tested our model by using the SPSS 17.0 and the LISREL 8.5. For measurement validation, we verified by using a confirmatory factor analysis and a reliability analysis. For hypothesis analysis, we did a path analysis with the LISREL 8.5. By checking the modification index and expecting parameter changes, we modified the model. First, the buyer's vertical coordination had a positive effect on the supplier's distributive fairness perception and procedural fairness perception. Second, the buyer's cooperation support had no effect on the supplier's distributive fairness perception and procedural fairness perception: we suppose that the buyer's requests were burdensome, although they cooperated with the supplier. Third, the buyer's information sharing had a positive effect on distributive fairness perception but had no direct effect on procedural fairness perception. Fourth, the buyer's legalistic plea had a negative effect on the supplier's distributive fairness perception. and a negative effect on the supplier's procedural fairness perception at a 0.1 significance level. Fifth, although procedural fairness perception had no direct effect on supply chain dependence, fairness perception had an effect on supply chain dependence and supply chain flexibility both directly and indirectly.

  • PDF

Analysis of the Vibration Characteristics of a High-Speed Train using a Scale Model (축소모델을 통한 고속철도 차량의 진동특성 해석 및 검증)

  • Han, Jae Hyun;Kim, Tae Min;Kim, Jeung Tae
    • Journal of the Korean Society for Railway
    • /
    • v.16 no.1
    • /
    • pp.7-13
    • /
    • 2013
  • A scaled version of a roller rig is developed to demonstrate the dynamic characteristics of a railway vehicle for academic purposes. This rig is designed based on Jaschinski's similarity law. It is scaled to 1/10 of actual size and allows 9-DOF motion to examine the up and down vibration of a train set. The test rig consists of three sub-hardware components: (i) a driving roller mechanism with a three-phase AC motor and an inverter, (ii) a bogie structure with first and second suspensions, and (iii) the vehicle body. The motor of the rig is capable of 3,600rpm, allowing the test to simulate a vehicle up to a maximum speed of 400Km/hr. Because bearings and joints are properly connected to the sub-structures, various motion analyses, such as a lateral, pitching, and yawing motion, are allowed. The slip motion between the rail and the wheel set is also monitored by several sensors mounted in the rig. After the construction of the hardware, an experiment is conducted to obtain the natural frequencies of the dynamic behavior of the specimen. First, the test rig is run and data are collected from six sets of accelerometers. Then, a numerical analysis of the model based on the ADAMS program is derived. Finally, the measurement data of the first three fundamental frequencies are compared to the analytical result and the validation of the test rig is conducted. The results show that the developed roller rig provides good accuracy in simulating the dynamic behavior of the vehicle motion. Although the roller rig designed in this paper is intended for academia, it can easily be implemented as part of a dynamic experiment of a bogie and a vehicle body for a high-speed train as part of the research efforts in this area.

A Quantitative Method for Human Face Volume Using 3D Optical Measurement (3D 측정 기기를 이용한 얼굴의 부피 정량법 연구)

  • Park, Shin-Young;Nam,, Gae-Won;Kim, Seung-Hun;Lee, Hea-Kang;Ahn, Sung-Yeon;Moon, Seong-Joon;Kim, Han-Kon
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.34 no.4
    • /
    • pp.333-338
    • /
    • 2008
  • The evaluation for the visage volume was performed with human and dummy face using PRIMOS $body^{(R)}$. Three researchers measured the dummy face attached different volume of clay (6.6 mL, 13.2 mL, and 19.8 mL). It is identified that the high correlation between measured values and real volume ($R^2=0.99$). The percent (%) of relative standard deviation (RSD) of the data was shown below 10%. In Gage R&R analysis, the percent of contribution, the percent of study variation and distinct categories values were 0.78%, 8.85%, and 15% respectively. Therefore this method was regarded as the good standard condition in aspect of reproducibility and repetitiveness of data. The face volume variation was measured by PRIMOS $body^{(R)}$ on the face in participated 10 healthy Korean women volunteers. Subjects used the product once a day for two weeks as night sleeping pack. After application of the test products, the 3D image data of face were taken 1 and 2 weeks later. We found the face volume was significantly decreased after using products. In conclusion, this novel non-invasive technique was useful in measuring and visualizing alterations in face volume as a consequence of certain treatments. This system will provide a rapid and precise analysis of 3D topographical information for face.

Construction and Validation of Infection Control Practice Scale for Dental Hygienist (치과위생사의 감염관리 실천도 측정도구의 개발과 타당화)

  • Cho, Young-Sik;Jun, Bo-Hye;Choi, Young-Suk
    • Journal of dental hygiene science
    • /
    • v.9 no.1
    • /
    • pp.53-59
    • /
    • 2009
  • Infection control is now recognized as an important quality indicator in dental health service setting. The purpose of this study was to develop and validate Dental Hygienist's Infection Control Practice Scale for quality management of dental health service in Korea. The data of 254 dental hygienists was subjected to exploratory factor analysis using SPSS 16.0 and confirmatory factor analysis using AMOS 16.0. The total items of preliminary scale were 21 items and 5 subscale. Principal component analysis was completed with Varimax rotation. The results show a change in factor structure from 5 factor solution to 4 factor solution. The confirmatory factor analysis confirmed the four subscales(Immunization and periodic tests, Clinical procedure, Handwashing, Personal protection) which have a total of 12 items. After the item deleted because factor loading was low, measured model was tested. The results of the measurement model indicated fit indices: $x^2$= 79.593(df = 38, 0 = 0.000), RMR = 0.045, GFI = 0.940, CFI = 0.904, AGFI = 0.896, NFI = 0.837, TLI = 0.861, RMSEA = 0.67. The squared correlation between four constructs were less than the average variance extracted(AVE) of four constructs. Multiple regression analysis was completed. Dependent variable was the perceived infection control practice by dental hygienist. Independent variables were four summated subscales(R = 0.552, $R^2$= 0.304, Adjusted $R^2$= 0.431, F = 25.813, p = 0.000). Unstandardized coefficients of three independent variables were statistically significant.

  • PDF

Multiple Determinations of Trichloroethylene Metabolites in a Concurrent Biological Media using High Performance Liquid Chromatography Coupled with Tandem Mass Spectrometry (HPLC-MS/MS를 이용한 트리클로로에틸렌 대사산물의 다중 분석법 확립)

  • Ahn, Youngah;Kho, Younglim;Lee, Seungho;Shin, Mi-Yeon;Jeon, Jung Dae;Kim, Sungkyoon
    • Journal of Environmental Health Sciences
    • /
    • v.40 no.2
    • /
    • pp.114-126
    • /
    • 2014
  • Objectives: We aimed to develop a measurement method of five metabolites of trichloroethylene (TCE) in a concurrent biological sample, e.g., trichloroacetic acid (TCA), dichloroacetic acid (DCA), S-(1,2-dichlorovinyl) glutathione (DCVG), S-(1,2-dichlorovinyl)-L-cysteine (DCVC), and N-Acetyl-S-(1,2-dichlorovinyl)-L-cysteine (NAcDCVC) and to validate the method before application to pharmacokinetic study. Methods: TCE metabolites were simultaneously analyzed using high performance liquid chromatography coupled with electrospray ionization mass spectrometry (HPLC-ESI-MS/MS) with as little as 50 ${\mu}L$ of serum and urine. DCA, TCA and NAcDCVC were extracted with diethyl ether, while DCVC and DCVG were extracted by solid phase extraction. This method was validated according to the guidelines for bioanalytical method validation of the Korean National Institute of Toxicological Research. Then, we determined the five metabolites in five strains of mice at 24 hr after exposure to 1 g TCE /kg body weight. Results: The limits of detection for the five metabolites in biological samples ranged from 0.001 to 0.076 nmol/mL, which is comparable to or better than those previously reported. Most calibration curves showed good linearity ($R^2=0.99$), and between-batch variation was less than 20% expressing acceptable robustness and reproducibility. Using this method, we found TCA and DCA were detected in all test mice at 24 hr after the oral administration while NAcDCVC and DCVC were detected in some strains, which showed strain-dependent metabolism of TCE. Conclusions: The present method could provide robust and accurate measurements of major key metabolites of TCE in biological media, which allowed concurrent analysis of TCE metabolism for limited amounts of biospecimens.

Analysis of the Radiation Patterns of Satellite SAR System with Active-Transponder (능동전파반사기를 이용한 위성 SAR 시스템 방사 패턴 분석)

  • Hwang, Ji-Hwan;Kweon, Soon-Koo;Oh, Yisok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.10
    • /
    • pp.1204-1211
    • /
    • 2012
  • Measurement and analysis results of the extracted radiation-patterns from the field-experiments which were conducted to acquire the generic technology for calibration and validation of the satellite SAR system(Synthetic Aperture Radar) are presented in this study. Prototype of active transponder is adjustable within maximum 63.1 dBsm of RCS (Radar Cross Section) and includes the receiving-function with external receiver. To increase an accuracy of these field experiments, we repetitively measured satellite SAR systems of the same operating mode(i.e., COSMO-SkyMed No. 2 & 3, hh-pol., strip-map himage mode, 3 m resolution). Then, the reliability of experimental results was cross-checked through analysis of the RCS of active transponder on SAR image. The property of azimuth radiation patterns of satellite SAR system extracted from them has $0.352^{\circ}$ of HPBW(half-power beamwidth), $0.691^{\circ}$ of FNBW(first-null beamwidth), and 11.17 dB of PSLR(peak to side lobe ratio), respectively.