• Title/Summary/Keyword: Measurement result filtering

Search Result 47, Processing Time 0.023 seconds

A Study on LED Distance Recognition Measure Using Distance Measurement Correction Algorithm (거리계산 보정 알고리즘을 이용한 LED 거리 인식 측정에 관한 연구)

  • Kim, Ji-Seong;Jung, Dae-Chul;Kim, Yong-Kab
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.2
    • /
    • pp.63-68
    • /
    • 2017
  • In this paper, Distance recognition measurement using distance calculation correction algorithm, was realization through LED dimming control. The calculation values for the RSSI average filtering and the RSSI feedback filtering were calculated and applied to reduce the error of the RSSI value measured from a long distance. It was confirmed that the RSSI values through the average filtering and the RSSI values measured by setting the coefficient value of the feedback filtering to 0.5 were ranged from -61 dBm to - 52.5 dBm, which shows irregular and high values decrease slightly as much as about -2 dBm to -6 dBm as compared to general measurements. A distance calculation correction algorithm to improve the accuracy was applied, which confirmed that as the distance increases, the range of errors decreases. In conclusion, unstable signals were corrected using the RSSI measurement result filtering, and the distance calculation correction algorithm was applied and performed to reduce the range of errors. In addition, RGB colors were implemented by LED to indicate the distance determination and the signal stability.

Improved Collaborative Filtering Using Entropy Weighting

  • Kwon, Hyeong-Joon
    • International Journal of Advanced Culture Technology
    • /
    • v.1 no.2
    • /
    • pp.1-6
    • /
    • 2013
  • In this paper, we evaluate performance of existing similarity measurement metric and propose a novel method using user's preferences information entropy to reduce MAE in memory-based collaborative recommender systems. The proposed method applies a similarity of individual inclination to traditional similarity measurement methods. We experiment on various similarity metrics under different conditions, which include an amount of data and significance weighting from n/10 to n/60, to verify the proposed method. As a result, we confirm the proposed method is robust and efficient from the viewpoint of a sparse data set, applying existing various similarity measurement methods and Significance Weighting.

  • PDF

Study on the influence of a screen in the surface roughness measure sstem based on parametric optical analysis (레이저 반사광을 이용한 표면 거칠기 측정 시스템에서 스크린의 영향에 관한 연구)

  • Seo, Young-Ho;Kim, Hwa-Young;Ahn, Jung-Hwan;Choi, Lee-Jon
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.845-850
    • /
    • 2003
  • The scattered light pattern from a machined surface generally contains much information concerning the surface roughness. The light pattern can be acquired by optical system and analyzed by statistical method. This kind of surface roughness measurement system can be easily adopted on the machine measurement. But the fully assembled system is too complex to implement on small systems using micro-controller. This study proposes the idea of reducing the number of optical components by removing screen and examines image processing of a light pattern to minimize the negative result of incomplete optical system. And the Gaussian blur filtering is concluded to be the best method of proposed measurement system. Furthermore light intensity variation of image pattern can be treated as a signal, therefore FIR filtering gives the similar result of Gaussian blur effect.

  • PDF

A Study on Distance Calculation Revision Algorithm using the Filtering of RSSI Measurement Results (RSSI 측정결과 필터링을 이용한 거리계산 보정 알고리즘에 관한 연구)

  • Kim, Ji-seong;Kim, Yong-kab
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.1
    • /
    • pp.25-31
    • /
    • 2017
  • The indoor location based service proposed in the study was assigned to target a moving user. Positioning in the outdoor environment is accurate while using GPS. However, in an indoor environment, positioning is inaccurate and difficult. In order to overcome this, studies of various techniques for positioning based on wireless communication such as Wi-Fi, Zigbee and Bluetooth are being performed. The RSSI value and the delivery signal of the bluetooth beacon are measured according to the distance, and to a database. It was applied calculating the value for the average RSSI and the RSSI filtering feedback. Filtering is used to reduce the error of the RSSI values that are measured at long distance. When average and feedback filtering coefficient are set with 0.5, irregular and highly RSSI values are decreased. As the distance increases, the range of error is confirmed to have a reduction when using a distance calculation correction algorithm. Finally, when using the RSSI measurement results filtering, it corrects an unstable signal. Also, the distance correction algorithm is used to reduce a range of errors.

PPG Filtering Method for Respiration Measurement in U-Health Care System (U-Health Care 환경에서 호흡측정을 위한 PPG 최적필터기술)

  • Kim, Jong-Hwa;Whang, Min-Cheol;Nam, Ki-Chang
    • Journal of the Ergonomics Society of Korea
    • /
    • v.27 no.4
    • /
    • pp.95-101
    • /
    • 2008
  • This research is to develop PPG filtering method for respiration measurement in U-Health Care system. Respiration rate was determined by filtering PPG and analyzing its spectrum. Optimal filter of PPG has been selected to get respiration by testing 120 sets of experiment data using 700 filtering cases. As a result, 2nd order Bessel-filter that used band-pass cutoff frequency at 0.175~0.4Hz with second order was good at developing respiration signal. Respiration signal in time domain could be continuously analyzed by converting frequency domain using spectrum analysis. 24 seconds has been found to be optimal time duration of collecting PPG data for determining respiration. Therefore, this study was successful of getting not only heart activity but also respiration by only PPG. Minimal invasive measurement obtaining multi-bio information by one sensor can be expected to apply to U-Health Care and human computer interaction.

Real time muscle fatigue monitoring by adaptive filtering algorithm (적응 필터링 알고리즘에 의한 근육 피로도의 실시간 측정)

  • 최영환;홍기릉;김성환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10b
    • /
    • pp.713-716
    • /
    • 1987
  • A new approach to the real-time measurement of muscle fatigue by using adaptive filtering algorithm is proposed. Unlike previously reported methods, it can estimate the muscle fatigue at every sample as the EMG signal statistics change. As a result, the muscle conduction velocity ranged between 4.2-5m/s at low tension and 3-4m/s at fatigue state.

  • PDF

Inward Leakage Test for Particulate Filtering Respirators in Korea (방진마스크의 안면부 누설률에 관한 연구)

  • Han Don-Hee
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.5 s.81
    • /
    • pp.432-439
    • /
    • 2004
  • Korean certification regulation for particulate filtering respirators requires inward leakage (IL) test as European Standards (EN) and the standard levels of regulation are the same as those of EN. This study was conducted to evaluate particulate filtering respirators being commercially used in the market by using IL and assess the characteristics of IL. The study began with discussing the concept of IL, comparison of IL with fit test, and IL measurement method. Three brands of half masks and 10 brands of filtering facepieces (two top class, four 1st class and four 2nd class), total 13 brands respirators, and 10 test panels (subjects) who were classified in 9 facial grids in accordance with face length and lip length, were selected for IL test. IL tests were conducted in the laboratory of 3M Innovation Center which was established by EN standard. As expected ILs of half masks were lower than those of filtering facepiece mask. ILs of half masks and some filtering facepieces were significantly different in manufacturers. ILs of 1st class filtering facepieces were found to be much more than those of 2nd class and thus the result would cause wearers to get confused to select a mask. Four of six brands being no compliance with standards were thought that they should be tested again for certification because of a lot of differences from standards. There were no significant differences among ILs of five exercises. In 6 out of 13 brands lognormal distribution of ILs may be a better fit distribution and in 7 brands both lognormal and normal distributions were rejected. The result indicates that geometric mean may be better than arithmetic mean to establish standard.

A Novel Filtering Method Based on a Nonlinear Tracking Differentiator for the Speed Measurement of Direct-drive Permanent Magnet Traction Machines

  • Wang, Gaolin;Wang, Bowen;Zhao, Nannan;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.358-367
    • /
    • 2017
  • This paper presents a novel filtering method for speed measurements to improve the low-speed performance of the direct-drive permanent magnet traction machines for elevators. Based on the theory of nonlinear tracking differentiator (NTD), this method, which can act as a high performance filter of a raw speed signal, obtains a more accurate speed feedback signal when applying a low-resolution encoder. In addition, it can relieve the interference caused by the position derivative for speed sampling. By analyzing the frequency response of the NTD, the influence of its parameters on the performance of the speed filtering is investigated. Compared with different types of low-pass filters, the proposed method shows a shorter time delay and a stronger ability in terms of noise suppression when the parameters are selected carefully. In addition, when using the measured speed signal through a nonlinear tracking differentiator as the feedback of the system, the motor runs more steadily at low speeds. As a result, the riding comfort of a direct-drive elevator can be improved. The feasibility of the proposed strategy was verified on an 11.7kW elevator traction machine using a commercial inverter.

Quasi-Optimal Linear Recursive DOA Tracking of Moving Acoustic Source for Cognitive Robot Auditory System (인지로봇 청각시스템을 위한 의사최적 이동음원 도래각 추적 필터)

  • Han, Seul-Ki;Ra, Won-Sang;Whang, Ick-Ho;Park, Jin-Bae
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.3
    • /
    • pp.211-217
    • /
    • 2011
  • This paper proposes a quasi-optimal linear DOA (Direction-of-Arrival) estimator which is necessary for the development of a real-time robot auditory system tracking moving acoustic source. It is well known that the use of conventional nonlinear filtering schemes may result in the severe performance degradation of DOA estimation and not be preferable for real-time implementation. These are mainly due to the inherent nonlinearity of the acoustic signal model used for DOA estimation. This motivates us to consider a new uncertain linear acoustic signal model based on the linear prediction relation of a noisy sinusoid. Using the suggested measurement model, it is shown that the resultant DOA estimation problem is cast into the NCRKF (Non-Conservative Robust Kalman Filtering) problem [12]. NCRKF-based DOA estimator provides reliable DOA estimates of a fast moving acoustic source in spite of using the noise-corrupted measurement matrix in the filter recursion and, as well, it is suitable for real-time implementation because of its linear recursive filter structure. The computational efficiency and DOA estimation performance of the proposed method are evaluated through the computer simulations.

Muscle Fatigue Monitoring Using Adaptive Digital Filter (적응 디지철 필터를 이용한 근육 피로도의 측정)

  • 최영환;변윤식;김철주;김성환
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.25 no.9
    • /
    • pp.1074-1080
    • /
    • 1988
  • A new approach to the measurement of muscle fatigue by adaptive digital filtering algorithm is proposed. Unlike previously reported methods, it can estimate the muscle fatigue at every sample as the EMG signal statistics change. As a result, the muscle conduction velocity ranged between 4.2-5m/s at low tension and 3-4m/s at fatigue state.

  • PDF