• 제목/요약/키워드: Measurement path

검색결과 759건 처리시간 0.029초

공간탐색경로에 따른 3차원 시각구조 도출과 정량적 개방도 측정에 관한 연구 (A Study on the Deduction of 3-Dimmensional Visual Structure and measurement of Quantitative Openness in Accordance with Spatial Probe Routes)

  • 김석태
    • 한국실내디자인학회논문집
    • /
    • 제19권6호
    • /
    • pp.112-120
    • /
    • 2010
  • Human can recognize the environment by detecting spatial perception, and most of environmental perception depends on visual perception. In view that the acquisition of spatial information is accomplished through visual recognition, analysis of visual structure contained in the space is thought to be very important sector in studying the characteristic of the space. The history of studies on visual structure of space, however, wasn't too long, and furthermore most of the theories up to now focused on static and planar principles. Under this circumstance, this study is intended to suggest new theory by combining Isovist theory and VGA theory that have been actively discussed as the theory on visual perception-based spatial structure and supplementing them between each other to expand into 3-dimensional model. The suggested theory is a complex principle in dimensional and dynamic form in consideration of visual direction, which forms 3-dimentional virtual model that enables visualization of the property of spatial structure as the routine discriminating whether visual connection is made between viewing point and target point, and the target point is included in the visual field quadrangular pyramid or not. Such model was built up by an analysis application where four probe paths were applied to simulate the visual structure that occurs in virtual space, and then the characteristics were analyzed through quantification. In result, in spite of the path with equal space and equal length, significant difference in the acquired quantity of spatial information could be found depending on the probe sequence. On the contrary, it was found that probe direction may not affect the acquired quantity of information and visual property of the space.

우리나라 선박 항로구간의 DGPS 전파 특성에 관한 연구 (A Study on the DGPS Radiobeacon Propagation Measurement of Domestic Ferry Lines)

  • 전중성;이서정
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권4호
    • /
    • pp.491-499
    • /
    • 2011
  • 1999년부터 운영이 시작된 팔미도, 어청도 DGPS 해상 기준국을 시작으로 우리나라에서는 총 17개의 DGNSS 기준국을 운영하고 있는 명실상부한 DGNSS 운영 인프라의 강국이 되었다. 본 논문은 DGPS 해양 기지국을 근간으로 사용하여 우리나라의 대표적인 정기여객선 항로 구간인 제주에서 인천, 부산에서 제주, 제주에서 녹동 구간의 300 kHz 주파수의 해상 및 육상에서의 전파특성을 측정하여, 해안 DPGS 기준국에서 서비스 범위를 조사함으로써, 우리나라 DGNSS 서비스 영역을 측정하였다. 서 남해안의 선박 항로구간의 DGPS 서비스 도달범위를 확인해 본 결과 우수한 품질의 전파신호가 100 NM(권장서비스 범위) 이상 도달됨을 확인하였다. 또한 이를 통하여 선박 안전항행 및 다양한 해양안전시설물에 대하여 위치보정정보의 활용과 향후 DGPS 해양 기준국 확장에 유용할 것으로 판단된다.

다연동 온실의 자연환기효율성 비교 분석 (Comparative Study on Efficiencies of Naturally-Ventilated Multi-Span Greenhouses in Korea)

  • 권순홍;정성원;권순구;박종민;최원식;김종순
    • 한국산업융합학회 논문집
    • /
    • 제20권1호
    • /
    • pp.8-18
    • /
    • 2017
  • This research analyzed the ventilation effect of the multi-span greenhouse based on the types of greenhouse structure, weather conditions, and locations inside the greenhouse. To compare and analyze the ventilation effects with different types of greenhouse, the uniform environmental conditions should be selected in advance. But these factors are not controlled and require tense many precision facilities and labor forces. Thus, the CFD simulation was used for the air stream to be analyzed qualitatively and quantitatively. In addition, for the ventilation effect analysis, the TGD (Tracer Gas Decay) was used to overcome the shortcomings of the current ventilation measurement method. The calculation error of ventilation rate using TGD was low (10.5%). Thus, the TGD is very effective in calculating the ventilation efficiency. The wind direction of 90 degrees showed the best ventilation effect. The ventilation rate also decreased along the air circulation path, and the rate was the lowest around the outlet. The computed fluid method (CFD) turned out to be a power tool for simulating flow behavior in greenhouse.

광 마이크로폰의 주파수 응답특성 분석 (Analysis of Frequency Response Characteristics in Optical Microphone)

  • 염경태;김관규;허도근;김용갑
    • 한국콘텐츠학회논문지
    • /
    • 제8권6호
    • /
    • pp.8-15
    • /
    • 2008
  • 본 논문에서는 광 마이크로폰의 주파수 응답특성 분석을 위해 시스템을 제안하고 구현하였다. 현재 사용되어지고 있는 캐패시턴스 마이크로폰과 광섬유 전송로형 광 마이크로폰(FOM)은 낮은 지향성과 크기, 무게, 비싼 가격 등에서 단점을 나타내고 있다. 반면 제안된 광 마이크로폰은 저가의 소자로 구성할 수 있으며, 소형, 경량화, 높은 지향성 등의 장점을 갖는다. 본 논문에서 제안하는 광 마이크로폰의 헤드 부는 인가된 음압에 따라서 전후로 움직이게 되어있으며, 반사판이 부착되어 있는 형태로 구성되어 있다. 광 헤드와 진동판사이의 거리를 변화시켜가며 응답특성을 측정하여 선형성과 민감도가 최대인 지점을 동작 점으로 결정하였다. 컴퓨터 기반 음향 측정/분석 프로그램인 Smaart Live와 USBPre를 사용하여 음향 신호의 주파수를 변화시켜 가며 구현한 광 마이크로폰의 광전 변환된 신호의 출력을 측정하였으며, 기존의 캐패시턴스 마이크로폰과 비교 분석하였다. 측정된 광 마이크로폰은 비교 콘덴서 마이크로폰과 거의 동일한 출력 특성을 나타내었으며, 주파수 대역폭은 약 ${\pm}3$[dB] 이내에서 300[Hz]-3[kHz] 정도의 성능을 나타내었다.

Simultaneous imaging and radiometric performance simulation for computer generated GOCI optical system with measured characteristics

  • Jeong, Soo-Min;Jeong, Yu-Kyeong;Ryu, Dong-Ok;Yoo, Jin-Hee;Kim, Seong-Hui;Cho, Seong-Ick;Ham, Sun-Jeong;Youn, Heong-Sik;Woo, Sun-Hee;Kim, Sug-Whan
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2008년도 한국우주과학회보 제17권2호
    • /
    • pp.27.3-28
    • /
    • 2008
  • In this study, we report a new Monte Carlo ray tracing technique for estimating GOCI (Geostationary Ocean Color Instrument) radiative transfer characteristics and imaging performance simultaneously. First, a full scale GOCI optical model was constructed with measured characteristics at the component level and placed in the geostationary orbit. An optical model of approximated GOCI target area centered at the Korean penninsular was then built using the USGS coastal line data and representative land and sea surface reflectivity data. The light rays launched from a simulated sun model travel to the Earth surface, where they are reflected and scattered. Some of the light rays that are headed to the GOCI model in the orbit were selected and traced, as they have entered into the GOCI aperture. As they pass through each GOCI optical part, the ray path and intensity are adjusted according to the measured characteristics for reflection, transmission, refractive index and surface scattering. The ray-traced imaging and radiative transfer performance indicators confirm that the computer generated GOCI optical system with measured characteristics can be used for in-orbit operation simulation following the designed measurement sequence. The computational technique and its implications as a operation support tool are discussed.

  • PDF

부정교합 진단을 위한 교합력 분석 소프트웨어의 설계 및 구현 : A Pilot Study (Design and Implementation of Occlusion Force Analysis Software for Malocclusion Diagnosis : A Pilot Study)

  • 박경종;김태윤;최흥국
    • 한국멀티미디어학회논문지
    • /
    • 제12권1호
    • /
    • pp.147-155
    • /
    • 2009
  • 교합력 측정과 분석은 힘의 관계를 분석하여 치아의 역학적 관계를 진단하는 방법이다. 본 연구에서는 새로운 교합력 측정 및 분석 시스템 개발의 기초 연구로써 측정 소프트웨어를 설계 및 구현하고 유용성을 평가한다. 이를 위해 교합력의 정상, 비정상을 효과적으로 측정할 수 있는 다양한 도구들을 개발하였다. 첫째, 치아에 작용하는 힘의 중심 변화를 나타내는 표지의 경로와 14개로 나뉜 치아 영역별 교합력 분포를 정량적인 수치와 함께 가시화 하였으며, 둘째, 교합력이 어느 치아의 특정한 영역으로 치우쳐서 작용하는가를 판단할 수 있도록 하기 위해 좌 우 치아 영역의 힘의 균형을 비율로 측정할 수 있는 도구를 구현하였다. 또한 0.5초 단위로 측정된 교합력의 변화를 소프트웨어 상에서 기록할 수 있도록 하였다. 센서 시트 방식의 측정 하드웨어와 연동하여 테스트한 결과, 힘의 분포와 균형을 효과적으로 확인할 수 있었다.

  • PDF

급성심근경색증 환자 중증도 보정 사망 모형 개발 (Development of Mortality Model of Severity-Adjustment Method of AMI Patients)

  • 임지혜;남문희
    • 한국산학기술학회논문지
    • /
    • 제13권6호
    • /
    • pp.2672-2679
    • /
    • 2012
  • 본 연구는 급성심근경색증 환자의 사망률 측정을 위한 중증도 보정 모형을 개발하여 의료의 질 평가에 필요한 기초자료를 제공하고자 수행되었다. 이를 위해서 질병관리본부의 2005-2008년 퇴원손상환자 699,701건의 자료를 분석하였다. Charlson Comorbidity Index 보정 방법을 이용한 경우와 새롭게 개발된 중증도 보정 모형의 예측력 및 적합도를 비교하기 위해 로지스틱 회귀분석을 실시하였다. 새롭게 개발된 모형에는 연령, 성, 입원경로, PCI 유무, CABG 유무, 동반질환 12가지 변수가 포함되었다. 분석결과 CCI를 이용한 중증도 보정 모형보다 새롭게 개발된 중증도 보정 사망 모형의 C 통계량 값이 0.796(95%CI=0.771-0.821)으로 더 높아 모형의 예측력이 더 우수한 것으로 나타났다. 본 연구를 통하여 중증도 보정 방법에 따라 사망률, 유병률, 예측력에도 차이가 있음을 확인하였다. 향후에 이모형은 의료의 질 평가에 이용하고, 질환별로 임상적 의미와 특성, 모형의 통계적 적합성 등을 고려한 중증도 보정모형이 계속해서 개발되어야 할 것이다.

3차 혼변조 왜곡 특성이 우수한 K-band 상향변환기 설계 (The Design of K-band Up converter with the Excellent IMD3 Performance)

  • 정인기;이영철
    • 한국정보통신학회논문지
    • /
    • 제8권5호
    • /
    • pp.1120-1128
    • /
    • 2004
  • 본 논문에서는 우수한 OIP3(ouput intercept point) 특성을 가지는 평형전력증폭단을 설계하고 이를 적용하여 K-band 상향변환기를 설계 및 제작하였다. 상향변환기의 구성은 전력 증폭기단, 국부발진신호 제거필터, 주파수혼합기및 IF단으로 구성하였으며 RF 경로의 동작 유무를 판단하기 위한 국부 루프 경로와 출력 전력을 감시하기 위한 감시 단자로 구성하여 소요되는 전력을 예측하였다. K-대역 MMIC를 이용하여 평형전력증폭단을 제작하였으며 전력 예측값에 의하여 상향변환기를 설계 제작하였다. 설계된 상향변환기의 이득은 $40\pm$2dB, PldB는 29dBm의 특성을 가지며, OIP3는 37.25dBm의 높은 특성이 나타내었다. 특히 전력증폭단의 MMIC를 조정하여 30dB이상의 이득을 제어하였다. 본 논문에서 제작한 상향변환기는 PTP 및 PTMP용 트랜시버에 사용할 수 있으며, QAM 및 QPSK 변조방식을 이용하는 디지털 통신 시스템 및 BWA(Broad Wireless System)에도 적용할 수 있다.

Development of Mandibular Movements Measuring System Using Double Stereo-Cameras

  • Park, Soon-Yong;Park, Sung-Kee;Cho, Chang-Hyun;Kim, Mun-Sang;Park, Mi-Gnon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1183-1188
    • /
    • 2005
  • In this paper, we propose a 3D automated measuring system which measures the mandibular movements and the reference plane of the jaw movements. In diagnosis and treatment of the malocclusions, it is necessary to estimate the mandibular movements and the reference plane of the jaw movements. The proposed system is configured with double stereo-cameras, PC, two moving pattern plates(MPPs), two fixed pattern plates(FPPs) and one orbital marker. The virtual pattern plate is applied to calculate the homogeneous transformation matrices which describe the coordinates systems of the FPP and MPP with respect to the world coordinates system. To estimate the parameters of the hinge axis, the Euler's theorem is applied. The hinge axis points are intersections between the FPPs and the hinge axis. The coordinates of a hinge axis point with respect to the MPP coordinates system are set up to fixed value. And then, the paths of the jaw movement can be calculated by applying the homogeneous transformation matrix to fixed hinge axis point. To examine the accuracy of the measurements, experiments of measuring the hinge axis points and floating paths of them are performed using the jaw motion simulator. As results, the measurement errors of the hinge axis points are within reasonable boundary, and the floating paths are very similar to the simulator's moving path.

  • PDF

동축 공동 공진기를 이용한 물방울 감지 센서 설계에 관한 연구 (Design of the Rain Sensor using a Coaxial Cavity Resonator)

  • 이윤민;김진국
    • 한국인터넷방송통신학회논문지
    • /
    • 제18권5호
    • /
    • pp.223-228
    • /
    • 2018
  • 본 논문은 동축 공동 공진기를 이용한 레인센서를 설계하고 제작한다. 선형적으로 빗방울을 감지할 수 있는 레인센서는 전압 제어 발진기 (VCO), 동축 공동 공진기, RF 스위치, RF 검출기, A / D 컨버터, DAC 및 마이크로 컨트롤러로 구성되었다. 설계된 레인 센서의 작동 주파수 범위는 2.5GHz ~ 3.2GHz이며, 입력 전압과 전류 소스는 24 [V / DC]와 1 [A]이다. 설계된 센서 회로는 VCO, RF 스위치, 고주파수 3GHz에서 소자의 주파수 특성을 변화시키는 RF 검출기를 포함한다. 센서 회로의 주파수 특성에 대한 오차를 교정한다. 이를 위해 공진기에 신호를 보내지 않고 RF 검출기로 신호를 직접 전달하는 기준 경로를 만든다. 시뮬레이션 및 측정 결과에 따르면 시뮬레이션된 공진기 주파수와 제작된 공진기 주파수 사이에 0-50MHz 차이가 있음을 알 수 있다.