• Title/Summary/Keyword: Measurement management

Search Result 3,931, Processing Time 0.033 seconds

The Clinical Aspects of Regional Lymphadenitis following BCG Vaccination (BCG 접종 후 국소 림프절염의 임상양상)

  • Bae, Sun Young;Park, Yang Joon;Kim, Jong-Hyun;Oh, Jin Hee;Koh, Dae Kyun;Kang, Jin Han
    • Pediatric Infection and Vaccine
    • /
    • v.13 no.2
    • /
    • pp.137-146
    • /
    • 2006
  • Purpose : A regional lymphadenitis is the most frequent adverse reaction of BCG. In order to find out developmental factors and establish a strategy of management, we investigated the clinical courses of children with lymphadenitis following BCG on the aspect of BCG strains, suppurative rates according to the sizes of lymph node and the clinical difference with or without treatment. Methods : From January 1997 to June 2004, 52 children less than 24 month-age-old diagnosed as BCG lymphadenitis in Department of Pediatrics, St. Vincent's Hospital, The Catholic University of Korea were enrolled. The type of BCG strain, place of vaccination, location and size of lymphadenitis were assessed with medical records, retrospectively. Finally, we analysed the correlations between BCG strains or the sizes of lymph node and natural remission or suppuration. Results : The first detected mean age of BCG lymphadenitis was 5.5 month-age. The larger of the measurement was at the first visiting, the younger of age that was first presented. The most frequent location was the same sided axillary region of BCG injection. Among 52 subjects, 46 cases(88.5%) were vaccinated with intradermal Pastuer strain, and only 5 cases(9.6%) were done with percutaneous multipunctured Tokyo strain. Twenty eight cases(53.8%) were regressed naturally, otherwise 24 cases(46.2%) were suppurated. The larger those were sized, the higher freqeuncies those were suppurated on, significantly. Treatment with medications could not prevent the suppuration and could not shorten the healing periods. Conclusion : We predict that there are differences between the occurrent rate of BCG lymphadenitis and BCG strains or methods. Treatment with medication is not recommended owing to its ineffectiveness. Especially, in case of non-suppurative lymphadenitis should be onlyless influence on the tuberculin skin test, cause less adverse reactions, and is inexpensive. observed without treatment, because it could be regressed naturally. An ideal BCG makes a scar, We should make an effort to choose the best BCG strain that can fulfill such requirements.

  • PDF

Analysis of the growth environment and fruiting body quality of Pleurotus eryngii cultivated by Smart Farming (큰느타리(새송이)버섯 스마트팜 재배를 통한 생육환경 분석 및 자실체 품질 특성)

  • Kim, Kil-Ja;Kim, Da-Mi;An, Ho-Sub;Choi, Jin-Kyung;Kim, Seon-Gon
    • Journal of Mushroom
    • /
    • v.17 no.4
    • /
    • pp.211-217
    • /
    • 2019
  • Currently, cultivation of mushrooms using the Information and Communication Technology (ICT)-based smart farming technique is increasing rapidly. The main environmental factors for growth of mushrooms are temperature, humidity, carbon dioxide (CO2), and light. Among all the mentioned factors, currently, only temperature has been maintained under automatic control. However, humidity and ventilation are controlled using a timer, based on technical experience.Therefore, in this study, a Pleurotus eryngii first-generation smart farm model was set up that can automatically control temperature, humidity, and ventilation. After installing the environmental control system and the monitoring device, the environmental condition of the mushroom cultivation room and the growth of the fruiting bodies were studied. The data thus obtained was compared to that obtained using the conventional cultivation method.In farm A, the temperature during the primordia formation stage was about 17℃, and was maintained at approximately 16℃ during the fruiting stage. The humidity was initially maintained at 95%, and the farm was not humidified after the primordia formation stage. There was no sensor for CO2 management, and the system was ventilated as required by observing the shape of the pileus and the stipe. It was observed that, the concentration of CO2 was between 700 and 2,500 ppm during the growth period. The average weight of the mushrooms produced in farm A was 125 g, and the quality was between that of the premium and the first grade.In farm B. The CO2 sensor was in use for measurement purposes only; the system was ventilated as required by observing the shape of the pileus and the stipe. During the growth period, the CO2 concentration was observed to be between 640 and 4,500 ppm. The average weight of the mushrooms produced in farm B was 102 g.These results indicate that the quality of the king oyster mushroom is determined by the environmental conditions, especially by the concentration of CO2. Thus, the data obtained in this study can be used as an optimal smart farm model, where, by improving the environmental control method of farm A, better quality mushrooms were obtained.

Applicability of Vegetation Index and SPAD Reading to Nondestructive Diagnosis of Rice Growth and Nitrogen Nutrition Status (식생지수와 SPAD를 이용한 벼 생육 및 질소영양상태의 비파괴적 진단 가능성 검토)

  • Kim Min-Ho;Shin Jin-Chul;Lee Byun-Woo
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.50 no.6
    • /
    • pp.369-377
    • /
    • 2005
  • Precise application of topdressing nitrogen (N) fertilizer is indispensible for securing high yield and good quality of rice and minimizing N losses to the environment as well. For precise N management, growth and nitrogen nutrition status (NNS) should be diagnosed rapidly and accurately. The objective of the study was to evaluate the applicability of vegetation index (VI) calculated from hyperspectral canopy reflectance measurement and SPAD reading to nondestructive in situ diagnosis of growth and NNS of rice. Canopy reflectance, SPAD read­ing, growth parameters, and NNS characteristics were measured from various N treatments to evaluate the relationships among them for two cropping seasons from 2001 to 2002. The correlation coefficient of VIs with variables of growth and NNS increased positively as rice canopy became more closed. Regardless of growth stages, VIs had significantly high correlations with LAI, shoot dry weight (DW), shoot N content and nitrogen nutrition index (NNI). Those correlation coefficients increased steadily before heading stage as rice grew up. However, tiller number and leaf N concentration showed significantly high correlations with VIs only at and after panicle initiation stage (PIS). Among the VIs, RVIgreen had significantly higher correlation with the measured parameters than the other VIs: it showed correlation coefficients greater than 0.8 with leaf and shoot N concentration and DW, and much higher coefficients greater than 0.9 with LAI, shoot N content, and NNI. At LAI of below 2.5, VIs had non-significant or low correlations with the growth and NNS indicators due to the background effects. SPAD reading had significantly high correlation with leaf N concentration and NNI at each growth stage. In addition, it had significant correlations with variables of growth and NNS at PIS and booting stage, particularly, at booting stage. Though SPAD reading had a significantly high correlation value at a given growth stage in each year, it showed very weak relationship with variables of growth and NNS when pooled across growth stages and years. In conclusion, RVIgreen was found to be the most reliable VI to estimate the growth and NNS of rice around at PIS, but SPAD reading had much limitations.

Diagnosis and management of the early defoliation of Korean flowering cherry in Gurye (구례 왕벚나무 가로수의 조기낙엽 진단 및 친환경적 관리 방법)

  • Han, Areum;Jin, Seon-deok;Jeong, Gilsang;Won, Ho-yeon;Lee, Young-sang;Son, Se Hwan;Choi, Sunghoon;Kang, Hyejin;Lee, ll Hwan;Han, Ah Reum
    • Korean Journal of Environmental Biology
    • /
    • v.37 no.4
    • /
    • pp.682-689
    • /
    • 2019
  • The Korean flowering cherry is a popular tree. However, the trees have started to defoliate early, including those in Gurye. Thus, it is necessary to identify the causes of the early defoliation and how to manage them. Therefore, the purpose of this study was threefold: 1) to investigate the early defoliation of flowering cherry trees, 2) to identify the differences in growth and flowering of the trees in response to treatment, and 3) to suggest an optimal treatment for the trees. The experiment was conducted in Gurye at a site 3km long with 102 flowering cherry trees along a street. There were three treatments: control, an environmentally friendly insecticide and a disinfectant(treatment 1), and an environmentally friendly insecticide, a disinfectant, and irrigation (treatment 2). The trees in Gurye were compared to trees on Jeju Island. The defoliation rates of the flowering cherry in Gurye were significantly higher than those on Jeju Island at each measurement time. Within Gurye, the defoliation rate was significantly higher in the trees of the control than in the two treatments and only the trees in the control from Gurye had shot-hole disease. Post-treatment, twigs collected from the control during April showed significantly poorer growth, lower numbers of flowering buds per twig, and lower numbers of foliar buds. The trees given treatment 1 showed significantly greater growth, number of total buds, flowering buds per twig, and density of buds than the trees given treatment 2. After analyzing the correlations, it was established that early defoliation led to poorer growth, affecting the flowering of the trees.

Establishment of Choline Analysis in Infant Formulas and Follow-up Formulas by Ion Chromatograph (이온크로마토그래프를 이용한 조제유류 및 영아용·성장기용 조제식 중 콜린 함량 분석법 연구)

  • Hwang, Kyung Mi;Ham, Hyeon Suk;Lee, Hwa Jung;Kang, Yoon Jung;Yoon, Hae Seong;Hong, Jin Hwan;Lee, Hyoun Young;Kim, Cheon Hoe;Oh, Keum Soon
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.5
    • /
    • pp.411-417
    • /
    • 2017
  • This study was conducted to establish the analysis method for the contents of choline in infant formulas and follow-up formulas by ion chromatograph (IC). To optimize the method, we compared several conditions for extraction, purification and instrumental measurement using spiked samples and certified reference material (CRM; NIST SRM 1849a) as test materials. IC method for choline was established using Ion Pac CG column and 18 mM $H_2SO_4$ mobile phase. The parameters of validation were specificity, linearity, LOD, LOQ, recovery, accuracy, precision and repeatability. The specificity was confirmed by the retention time and the linearity, $R_2$ was over 0.999 in range of 0.5~10 mg/L. The detection limit and quantification limit were 0.14, 0.43 mg/L. The accuracy and precision of this method using CRM were 95%, 2.1% respectively. Optimized methods were applied in sample analysis to verify the reliability. All the tested products were acceptable contents of choline compared with component specification for nutrition labeling. The standard operating procedures were prepared for choline to provide experimental information and to strengthen the management of nutrient in infant formula and follow-up formula.

Analysis of Correlation with Cross Sectional Area of Flow and Flow Rate Variation of Discharge Measurement Point in the Upper Stream of Seomjin River (섬진강상류 유량측정지점의 유수단면적과 유량변화에 따른 상관관계 분석)

  • Song, KwangDuck;Kim, KapSoon;Lee, DongJin;Ham, SangIn;Kim, DaeYoung;Oh, TaeYoun;Lee, JaeChoon;Lim, ByungJin
    • Korean Journal of Ecology and Environment
    • /
    • v.46 no.1
    • /
    • pp.94-102
    • /
    • 2013
  • This study was carried out to determine the variation of the water level and crosssection area for investigating changes of stream foreland, and to determine the correlation between the average flow velocity and cross-section area so as to understand the hydrological characteristics of the stream. The slope of the cross-sectional area was changed in water levels of 0.6~1.0 m and 1.8~2.0 m. The first change occurred in the low-water level season, and the second change occurred in the high-water level seasons. It is assumed that the changes occurred due to the geological transfigure. The correlation between the cross-sectional area and the average flow velocity was 0.22~0.86 in the exponential equation and 0.20~0.87 in the linear equation. The low water level had a higher correlation than the high water level, and free weirs in the upper stream showed a very low correlation. Therefore, this study provides novel information for the management of water quality in the riverside, using correlation equations of the water level and flow velocity with the cross section area.

A Study on Intuitive IoT Interface System using 3D Depth Camera (3D 깊이 카메라를 활용한 직관적인 사물인터넷 인터페이스 시스템에 관한 연구)

  • Park, Jongsub;Hong, June Seok;Kim, Wooju
    • The Journal of Society for e-Business Studies
    • /
    • v.22 no.2
    • /
    • pp.137-152
    • /
    • 2017
  • The decline in the price of IT devices and the development of the Internet have created a new field called Internet of Things (IoT). IoT, which creates new services by connecting all the objects that are in everyday life to the Internet, is pioneering new forms of business that have not been seen before in combination with Big Data. The prospect of IoT can be said to be unlimited in its utilization. In addition, studies of standardization organizations for smooth connection of these IoT devices are also active. However, there is a part of this study that we overlook. In order to control IoT equipment or acquire information, it is necessary to separately develop interworking issues (IP address, Wi-Fi, Bluetooth, NFC, etc.) and related application software or apps. In order to solve these problems, existing research methods have been conducted on augmented reality using GPS or markers. However, there is a disadvantage in that a separate marker is required and the marker is recognized only in the vicinity. In addition, in the case of a study using a GPS address using a 2D-based camera, it was difficult to implement an active interface because the distance to the target device could not be recognized. In this study, we use 3D Depth recognition camera to be installed on smartphone and calculate the space coordinates automatically by linking the distance measurement and the sensor information of the mobile phone without a separate marker. Coordination inquiry finds equipment of IoT and enables information acquisition and control of corresponding IoT equipment. Therefore, from the user's point of view, it is possible to reduce the burden on the problem of interworking of the IoT equipment and the installation of the app. Furthermore, if this technology is used in the field of public services and smart glasses, it will reduce duplication of investment in software development and increase in public services.

The effects of the direct nursing care hours with establishment of the nurse substations (Nurse Substation 운영이 직접간호시간 증가에 미치는 효과)

  • Lee, Chug-Hee;Sung, Young-Hee;Kwon, In-Gak;Lee, Soon-Kyu;Jung, Yoen-Yi;Hoe, Sung-Hee;Ryoo, Sung-Suk;Kim, Jung-Suk
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.3 no.2
    • /
    • pp.61-80
    • /
    • 1997
  • The purpose of this study is to measure the direct and indirect nursing care hours with establishment of nurse substations and compare the experimental nursing units with the existing nursing units For this study, two experimental nursing units: (1) a medical nursing unit and (2) a surgical nursing unit with a nurse substation were selected. And two control nursing units : (1) a medical nursing unit and (2) a surgical nursing unit without a nurse substation were selected. After a three-month experimental operation from June 1 to August 31,1996, research data were collected for three days from September 2 to 4, 1996. We investigated the effects of the direct & indirect nursing care hours with establishment of the nurse substations (improved nursing environment) without adding the staff nurses. The effect of establishment of the nurse sub-station was measured for the differences direct & indirect nursing care hours between experimental and control nursing units. An investigator measured the time for a staff nurse to practice each nursing activity and recorded it every minute. Percentage, average, standard deviation, t-test and ANOVA were used for data analysis. The results are as follows: 1. There was no significant difference between the experimental and control nursing units in staffs' working hours during their shift. 2. There were significant diffferences between the experimental and control nursing units in dierct nursing care hours (t=0.0288, p=0.0001) and indirect nursing care hours (t=0.3886, p=0.0103) per patient. 3. There was significant difference between the experimental and control nursing units in direct nursing care hours done by nurses(t=0.0012, p=0.0111) and aids(t=0.3011, p=0.0027). There was significant difference between the experimental and control nursing units in indirect nursing care hours done by head-nurses(t=0.0051, p=0.0253), nurses(t=0.0071, p=0.0024) and aids (t=0.3227, p=0.0351). There was significant difference between the experimental and control nursing units in indirect nursing care hours done by nurses(t=0.0005, p=0.0015) and aids(t=0.2400, p=0.0013) per patient. There was significant difference between the experimental and control nursing units in indirect nursing care hours done by head-nurses(t=0.0005, p=0.0379) and nurses (t=0.0035, p=0.0198) per patient. 4. Thre were significant differences between the experimental and control nursing units in direct nursing care hours (t=0.1134, p=0.0010) and indirect nursing care hours (t=0.7106, p=0.0008) per staff during the day shift. There were significant differences between the experimental and control nursing units in direct nunsing care hours during the day(t=0.0723, p=0.0003) and evening shift (t=0.0004, p=0.0285) per patient, and indirect nursing care hours during the day shift(t=0.5565, p=0.0036) per patient. 5. There were differences between the experiemental and control nursing units in dircet nursing activities including measurement and observation, medication, communication, teratment, hygiene, and nutrition, and in indirect nursing activities including confirmantion, communication, record, computer work, management of goods. But it was not statistically proven. 6. There was difference between the experimental and control nursing units in unmet-need nursing care hours per patient, but not statistically proven.

  • PDF

An Evaluation of the Accuracy of Mini-Wright Peak Flow Meter (mini-Wright Peak Flow Meter에 의한 PEFR 측정의 정확도)

  • Koh, Young-Il;Choi, In-Seon;Na, Hyun-Ju;Park, Seok-Chae;Jang, An-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.2
    • /
    • pp.298-308
    • /
    • 1997
  • Background : Portable devices for measuring peak expiratory flow(PEF) are now of proved value in the diagnosis and management of asthma and many lightweight PEF meters have become available. However, it is necessary to determine whether peak expiratory flow rate(PEFR) measurements measured with peak flowmeters is accurate and reproducible for clinical application. The aim of the present study is to define accuracy, agreement, and precision of mini-Wright peak flow meter(MPFM) against standard pneumotachygraph. Methods : The lung function tests by standard pneumotachygraph and PEFR measurement by MPFM were performed in a random order for 2 hours in 22 normal and 17 asthmatic subjects and also were performed for 3 successive days in 22 normals. Results : The PEFR measured with MPFM was significantly related to the PEFR and $FEV_1$ measured with standard pneumotachygraph in normal and asthmatics(for PEFR, r = 0.92 ; p < 0.001 ; for $FEV_1$, r = 0.78 ; p < 0.001). The accuracy of MPFM was within 100(limits of accuracy recommeded by NAEP) in all the subjects or 22 normal, mean difference from standard pneumotachygraph being 16.5L/min(percentage of difference being 2.90%) or 10.6L/min(percentage of difference being 1.75%), respectively. According to the method proposed by Bland and Altman, the 95% limits of the distribution of differences between MPFM and standard pneumotachygraph after correction of PEFR using our regression equation were +38.2 and -71.5L/min in all the subjects or 20.49~+9.49L/min in 22 normal and was similar to the intraindividual agreements for 3 successive days in normal. There was no statistically significant difference of PEFR measured with MPFM and standard pneumotachygraph among three days(p > 0.05) and the coefficient of variation($2.4{\pm}1.2%$) of PEFR measured with MPFM was significantly lower than that($5.2{\pm}3.5%$) with standard pneumotachygraph in normal (p < 0.05). Conclusion : This results suggest that the MPFM was as accurate and reproducible as standard pneumotachygraph for monitoring of PEFR in the asthmatic subjects.

  • PDF

Daily Shoot Growth Measurement of Zoysiagrass (Zoysia japonica) to Determine Mowing Interval (한국잔디(Zoysia japonica)의 깎기주기 결정을 위한 지상부 생육 조사)

  • Lee, Hyo-Soon;Yang, Geun-Mo;Choi, Joon-Soo
    • Asian Journal of Turfgrass Science
    • /
    • v.24 no.1
    • /
    • pp.16-23
    • /
    • 2010
  • Mowing is an important practice in golf course management. Mowing interval and height can affect net photosynthesis of turfgrass and finally shoot density, tillering, rooting and regrowth of turfgrass. The objectives of this study were to investigate the regrowth rate of zoysiagrass shoot under different mowing height for determination of proper mowing frequency. Recommended mowing interval were calculated by a rule that no more than 33% of the above ground height be removed in a single mowing. Daily shoot growth of zoysiagrass at 10 mm mowing height were 2.1~4.7 mm (July), 1.9~2.9 mm (August), 0.9~1.5 mm (September), and 0.6 mm (October). These results indicate that recommended mowing interval were 1.1~2.3 day for July, 1.7~2.4 day for August, 3.5~5.4 day for September, and 8.5 day for October, respectively. Daily shoot growth of zoysiagrass at 15 to 17 mm mowing height were 4.0~5.3 mm (July), 2.9~4.5 mm (August), 1.4~3.7 mm (September), and 1.3 mm (October). These results indicate that recommended mowing interval were 1.4~1.9 day for July, 1.7~2.5 day for August, 2.3~6.3 day for September, and 6.8 day for October, respectively. Daily shoot growth of zoysiagrass at 18 to 21 mm mowing height were 3.5~4.7 mm (July), 2.9~4.9 mm (August), and 1.5~1.8 mm (September). These results indicate that recommended mowing interval were 1.9~2.6 day for July, 1.8~3.1 day for August, and 5.9~7.0 day for September, respectively. Daily shoot growth of zoysiagrass at 50 mm mowing height were 4.6~4.9 mm (July), 5.0~6.5 mm (August), and 2.5~4.7 mm (September). These results indicate that recommended mowing interval were 5.1~5.4 day for July, 3.9~5.0 day for August, and 5.3~9.8 day for September, respectively.