• Title/Summary/Keyword: Measurement and assessment

Search Result 1,988, Processing Time 0.036 seconds

The effect of Neurofeedback training on brain wave activity and cognitive performance in chronic stroke patients (뉴로피드백(Neurofeedback) 훈련이 만성 뇌졸중 환자의 뇌파활성도와 인지수행력에 미치는 효과)

  • Lee, Young-Sin;Kim, Sang-Yeob;Kim, Chan-Kyu;Jung, Dae-In;Kim, Kyung-Yoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.5
    • /
    • pp.2329-2337
    • /
    • 2013
  • This study was done objected to the chronic stroke patients in order to evaluate change in brain wave activity and cognitive performance when Neurofeedback training. The subjects were over 6 months ago in chronic stroke patients screened-test through the 20 patients, 10 persons in each group were randomly placed. This was carried out in 4 weeks in total, with control group(n=10) on general physical therapy and experimental group(n=10) on general physical therapy along with Neurofeedback training. The general physical therapy was applied 5 times a week, 30 minutes at once, Neurofeedback training was applied as equally as the general physical therapy, which makes 20 times in total. To learn about the effect before the training, after training, and 2 weeks after the training in electric physiological measurement method of the brain, electroencephalogram(EEG) to examine challenges by calculating the absolute spectrum power for standard EEG change(%), followed by evaluation with clinical assessment tool MMSE-K, Stroop Test, Digit Span Test. As a result of comparing the change in brain wave through EEG, after training and 2 weeks after training showed that absolute ${\alpha}$-power and absolute ${\beta}$-SMR power of experimental group have increased and absolute ${\theta}$-power decreased significantly compared to experimental group I. Moreover, the MMSE-K score in trial appraisal has increased significantly, and the error in Stroop Test and Digit Span Test has decreased significantly. such results, with the chronic stroke patient's brain wave control, Neurofeedback training was determined to improve the cognitive performance. this study suggests a new training possibility of stroke patients by identifying the training effects of Neurofeedback training that trains the brain directly with brain wave control.

The Acceptance Testing of 5 Mega Pixels Primary Electronic Display Devices and the Study of Quality Control Guideline Suitable for Domestic Circumstance (5 Mega 화소 진단용 전자표시장치 인수검사 및 국내 실정에 적합한 정도관리 가이드라인 연구)

  • Jung, Hai-Jo;Kim, Hee-Joung;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.98-106
    • /
    • 2007
  • In June 2005, Yonsei University Medical Center, Severance Hospital upgraded a full-PACS system by adding twenty (5 mega pixels) Totoku ME511L flat panel LCD display devices for diagnostic interpretation purposes. Here we report upon the quantitative (or visual) acceptance testing of the twenty Totoku ME511L display devices for reflection, luminance response, luminance spatial dependency, resolution, noise, veiling glare, and display chromaticity based on AAPM TG 18 report. The tools used in the tests included a telescopic photometer, which was used as a colorimeter, illuminance meter, light sources for reflection assessment, light-blocking devices, and digital TG18 test patterns. For selected 8 flat panel displays, mean diffuse reflection coefficient ($R_d$) was $0.019{\pm}0.02sr^{-1}$. In the luminance response test, luminance ratio (LR), maximum luminance difference ($L_{max}$), and deviation of contrast response were $550{\pm}100,\;2.0{\pm}1.9%\;and\;5.8{\pm}1.8%$, respectively. In the luminance uniformity test, maximum luminance deviation was $14.3{\pm}5.5%$ for the 10% luminance of the TG18-UNL10 test pattern. In the resolution test with luminance measurement method, percent luminance (${\Dalta}L$) at the center was $0.94{\pm}0.64%$. In all cases of noise testing, rectangular target In every square in the three quadrants was visible and all 15 targets except the smallest one in the every corner pattern and the center pattern. The glare ratio (GR) was $12,346{\pm}1,995$. The color uniformity, (u',v'), was $0.0025{\pm}0.0008$. Also, the research results of qualify control guideline of primary disply devices suitable for domestic circumstance are presented All test results are in-line with the criteria recommended by AAPM TG18 report and are thus fully acceptable for diagnostic image interpretation. As a result, the acceptance testing schedule described provides not only an acceptance standard but also guidelines for quality control, optimized viewing conditions, and a means for determining the upgrading time of LCD display devices for diagnostic interpretation.

  • PDF

Production and Assessing Usefulness of the Moving Phantom for Respiration Gated Radiotherapy (호흡동조 방사선치료용 팬텀의 제작 및 유용성 평가)

  • Lee, Yang-Hoon;Lee, Jae-Hee;Yoo, Suk-Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.135-144
    • /
    • 2010
  • Purpose: The purpose of this study is that through production of phantom for respiration gated radiotherapy, assessing appropriacy of exposure dose for the therapy using RPM (Real-time Position Management). Materials and Methods: We located measurement object on the phantom for respiration gated radiotherapy made of 2 linear actuator, acrylic panel, stanchion, iron plate ets. to drive (up, down, front, back). Using 4D CT scan, we analyzed patient's respiration and reproduced the movement by computer. On the phantom, we located a 2D-Array (PTW) and an White water phantom (4.5 cm) and used DMLC (interval 2 cm) in the field size $10{\times}10\;cm$, then exposed 21EX X-ray 100 MU, in the case of phantom was (1) static (2) moving (3) gated using RPM respectively gantry $0^{\circ}$ and $90^{\circ}$ We measured with a 0.125 CC ionization chamber (PTW) on the phantom (7.5 cm) in the same condition. Results: Ionization chamber: There were within 0.3% of error with gating respiration and approximately 2% of error without gating in the same condition. 2D-Array: Gantry $90^{\circ}$, field size $10{\times}10\;cm$, using DMLC. There were within 3% of error with gating respiration and approximately 16% of error without gating. Conclusion: The phantom for respiration gated radiotherapy makes plans considering patient's movement, quantitative analysis of exposure dose and proper assessment therapy for IMRT patients using RPM possible.

  • PDF

A Model based Vocational Evaluation for People with Psychiatric Disabilities (정신장애인 직업재활모델과 직업평가 - 직업기능척도 개발을 위한 예비연구 -)

  • Lee, Seong-Gyu;Kim, Sang-Hee
    • Korean Journal of Social Welfare
    • /
    • v.54
    • /
    • pp.123-147
    • /
    • 2003
  • It is well known that one of essential features of psychiatric disability is vocational impairment. Since the year of 2000 when psychiatric disability was declared as one of disability categories in Korea, vocational rehabilitation programs have been actively administered. At this point, it is compelling that vocational evaluation serves as a means of screening out the most promising candidates, identifying their vocational deficits and strengths, designing the individualized vocational interventions, and evaluating vocational outcomes. Still, vocational evaluation for people with psychiatric disabilities has been more problematic than for any other group with disabilities. The authors argued that vocational evaluation for people with psychiatric disabilities should be based on a certain vocational rehabilitation model to address those problems. It is because there exists an indispensible relationship between the vocational rehabilitation model and vocational evaluation. In other words, the main purposes, measurement time points, and focus of vocational evaluation may depend on which of vocational rehabilitation models to make a choice of. In addition, the vocational rehab model(i.e., vocational readiness model or graduation model) underlying traditional vocational evaluation does not seem to work for people with psychiatric disabilities. Authors argued that accelerating model fits for psychiathric characteristics which are often unpredictable and turbulent. As a preliminary step of developing vocational functioning instrument incorporating the demand characteristics of the accelerating model, post-hoc analyses were done on data from a vocational functioning measure and the results were critically examined from viewpoints of accelerating model. For these purposes, discussions were made about a) general functioning of vocational evaluation, (b) relation between vocational rehabilitation model and vocational evaluation, (c) the reasons why the accelerating model is more appropriate to the characterstics of psychiatric clients than the graduation model, (d) post-hoc analytic results reviewed from viewpoints of accelerating model-based vocational evaluation This study is significant in that it attempted model-based, model-specific vocational evaluation as a preliminary step for developing vocational functioning assessment instruments ill future.

  • PDF

Measurement and Assessment of Absolute Quantification from in Vitro Canine Brain Metabolites Using 500 MHz Proton Nuclear Magnetic Resonance Spectroscopy: Preliminary Results (개의 뇌 조직로부터 추출한 대사물질의 절대농도 측정 및 평가: 500 MHz 고자장 핵자기공명분광법을 이용한 예비연구결과)

  • Woo, Dong-Cheol;Bang, Eun-Jung;Choi, Chi-Bong;Lee, Sung-Ho;Kim, Sang-Soo;Rhim, Hyang-Shuk;Kim, Hwi-Yool;Choe, Bo-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.2
    • /
    • pp.100-106
    • /
    • 2008
  • The purpose of this study was to confirm the exactitude of in vitro nuclear magnetic resonance spectroscopy(NMRS) and to complement the defect of in vivo NMRS. It has been difficult to understand the metabolism of a cerebellum using in vivo NMRS owing to the generated inhomogeneity of magnetic fields (B0 and B1 field) by the complexity of the cerebellum structure. Thus, this study tried to more exactly analyze the metabolism of a canine cerebellum using the cell extraction and high resolution NMRS. In order to conduct the absolute metabolic quantification in a canine cerebellum, the spectrum of our phantom included in various brain metabolites (i.e., NAA, Cr, Cho, Ins, Lac, GABA, Glu, Gln, Tau and Ala) was obtained. The canine cerebellum tissue was extracted using the methanol-chloroform water extraction (M/C extraction) and one group was filtered and the other group was not under extract processing. Finally, NMRS of a phantom solution and two extract solution (90% D2O) was progressed using a 500MHz (11.4 T) NMR machine. Filtering a solution of the tissue extract increased the signal to noise ratio (SNR). The metabolic concentrations of a canine cerebellum were more close to rat’s metabolic concentration than human’s metabolic concentration. The present study demonstrates the absolute quantification technique in vitro high resolution NMRS with tissue extraction as the method to accurately measure metabolite concentration.

  • PDF

Change of Regional Myocardial Blood Flow After Transmyocardial Laser Revascularization in Porcine Model of Chronic Myocardial Ischemia (돼지 만성 심근허혈 모델에서 경심근레이저혈류재건술 후 국소 심근 혈류량의 변화)

  • Park, Kay-Hyun;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.662-671
    • /
    • 2001
  • Background: This study was aimed to assess improvement in myocardial perfusion after TMR by measuring regional myocardial blood flow(RMBF) in porcine model of chronic myocardial ischemia. Material and Method: Ameroid ring was placed around the proximal left circumflex coronary artery in fourteen pigs. After 4 weeks, the control group(7 pigs) underwent rethoracotomy only, and the TMR group(7 pigs) underwent Ho:YAG laser TMR at the circumflex territory. After another 4 weeks, the animals were sacrificed for the measurement of RMBF using colored microspheres. The ratio of RMBF between the circumflex territory and the interventricular septum was calculated and compared. Result: At 4 weeks after ameroid constriction, RMBF of the circumflex territory decreased to 46∼89% of RMBF of the interventricular septum. In five of six animals in the TMR group, RMBF of the circumflex territory at 8 weeks after ameroid constriction was higher compared with RMBF at 4 weeks after ameroid constriction. However, the improvement was statistically significant only in two animals. In three of the four animals in the control group, RMBF of the circumflex territory also increased at 8 weeks compared with RMBF at 4 weeks. The degree of increase in RMBF was not different between the control and the TMR groups. Conclusion: In porcine model of chronic myocardial ischemia, the degree of increase in RMBF of the ischemic area after Ho:YAG TMR was not different from the increase by development of native collateral circulation. Perfusion of ischemic myocardium after TMR is not thought to improve to the degree that can be demonstrated by currently available method of assessment such as radioisotope myocardial scintigraphy.

  • PDF

Effects of Pregnant Rate after Embryo Transfer in Oxygen Consumption of Embryos in Korean Cattle (한우 수정란의 산소 소비량이 수청란이식 수태윷에 미치는 영향)

  • Choe, Chang-yong;Son, Jun-Kyu;Cho, Sang-Rae;Kang, Da-won;Yeon, Seong-Heum;Choi, Sun-Ho;Choi, Soo-Ho;Kim, Nam-Tae;Kim, Jae-Bum;Jung, Yeon-Sub;Kim, Sung-Jae;Jung, Jin-Woo;Bok, Nan-Hee;Yoo, Yong-Hee;Son, Dong-Soo
    • Journal of Embryo Transfer
    • /
    • v.25 no.3
    • /
    • pp.145-148
    • /
    • 2010
  • Oxygen consumption has been regarded as a useful indicator for assessment of mammalian embryo quality. This study was performed to investigate whether oxygen consumption reflects morphological grade of in vivo derived bovine blastocyst-stage embryos (blastocyst). The oxygen consumption of in vitro produced blastocyst was compared to its total cell number. In addition, pregnant rate was measured after transplantation of in vivo blastocysts with different oxygen consumption. The quality of blastocyst collected on day 7 after artificial insemination was categorized as grade I and II (G I and G II) based on microscopic observation of the morphology. Oxygen consumption of blastocyst was measured using a scanning electrochemical microscopy (SECM) and total cell number of in vitro blastocyst was enumerated by counting cells stained by propidium iodide. Pregnancy of recipient cow was confirmed with rectal palpation after 60 days of embryo transfer. The oxygen consumptions of G I blastocysts were significantly higher than those of G II blastocysts ($10.2{\times}10^{15}/mol\;s^{-1}$ versus $6.4{\times}10^{15}/mol\;s^{-1}$, p<0.05). Total cell numbers of in vitro blastocysts were 74.8, 90.7, and 110.2 in the oxygen consumption of below 10.0, 10.0~12.0, and over $12.0{\sim}10^{15}/mol\;s^{-1}$ respectively. Total cell number was significantly increased in embryos with high oxygen consumption (p<0.05). Pregnant rate in recipient cow was 0, 50, and 85.7% in the transplantation of embryo with the oxygen consumption of below 10.0, 10.0~12.0, and over $12.0{\times}10^{15}/mol\;s^{-1}$, respectively. These results suggest that measurement of oxygen consumption may help increase the pregnant rate of bovine embryos.

A preliminary assessment of high-spatial-resolution satellite rainfall estimation from SAR Sentinel-1 over the central region of South Korea (한반도 중부지역에서의 SAR Sentinel-1 위성강우량 추정에 관한 예비평가)

  • Nguyen, Hoang Hai;Jung, Woosung;Lee, Dalgeun;Shin, Daeyun
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.6
    • /
    • pp.393-404
    • /
    • 2022
  • Reliable terrestrial rainfall observations from satellites at finer spatial resolution are essential for urban hydrological and microscale agricultural demands. Although various traditional "top-down" approach-based satellite rainfall products were widely used, they are limited in spatial resolution. This study aims to assess the potential of a novel "bottom-up" approach for rainfall estimation, the parameterized SM2RAIN model, applied to the C-band SAR Sentinel-1 satellite data (SM2RAIN-S1), to generate high-spatial-resolution terrestrial rainfall estimates (0.01° grid/6-day) over Central South Korea. Its performance was evaluated for both spatial and temporal variability using the respective rainfall data from a conventional reanalysis product and rain gauge network for a 1-year period over two different sub-regions in Central South Korea-the mixed forest-dominated, middle sub-region and cropland-dominated, west coast sub-region. Evaluation results indicated that the SM2RAIN-S1 product can capture general rainfall patterns in Central South Korea, and hold potential for high-spatial-resolution rainfall measurement over the local scale with different land covers, while less biased rainfall estimates against rain gauge observations were provided. Moreover, the SM2RAIN-S1 rainfall product was better in mixed forests considering the Pearson's correlation coefficient (R = 0.69), implying the suitability of 6-day SM2RAIN-S1 data in capturing the temporal dynamics of soil moisture and rainfall in mixed forests. However, in terms of RMSE and Bias, better performance was obtained with the SM2RAIN-S1 rainfall product over croplands rather than mixed forests, indicating that larger errors induced by high evapotranspiration losses (especially in mixed forests) need to be included in further improvement of the SM2RAIN.

Usefulness of Interferon-$\gamma$ Measurement Following Stimulation of Tuberculosis-specific Antigens for Diagnosis of Latent Tuberculosis Infection in Children Exposed to Pulmonary Tuberculosis (폐결핵 접촉력을 가진 소아에서 잠복 결핵 감염의 진단을 위한 결핵 특이항원 자극 인터페론-감마 측정의 유용성)

  • Sung, Ji Yeon;Ki, Joo Hwa;Yang, Mi Ae;Kim, So Hee;Eun, Byung Wook;Kim, Nam Hee;Park, Kyoung Un;Lee, Jina;Choi, Eun Hwa;Lee, Hoan Jong
    • Pediatric Infection and Vaccine
    • /
    • v.15 no.1
    • /
    • pp.52-58
    • /
    • 2008
  • Purpose : Whole blood interferon-$\gamma$ assay was developed and many studies showed its usefulness in diagnosing tuberculosis (TB) including latent tuberculosis infection (LTBI). However, assessment in children has been limited. This study was undertaken to evaluate the usefulness of QuantiFERON-TB Gold for the diagnosis of LTBI in children exposed to pulmonary TB. Methods : Children who visited Seoul National University Bundang Hospital with a history of TB exposure were enrolled from January 2006 to December 2007. They were evaluated with chest x-rays, tuberculin skin test (TST) and QuantiFERON-TB Gold test. TST was retested 3 months later for those with initial negative reactivity. Definition of LTBI was made on the basis of the TST reactivity. Results : Among the 103 children with a history of TB exposure, 49 children were tested with chest x-ray, TST, and QuantiFERON-TB Gold. Twenty-two were males. Median age was 7.5 years (range; 3 months to 14.7 years). According to TST reactivity, LTBI was in 8 (19%), no infection was in 21 (50%), possible LTBI was in 13 (31%). QuantiFERON-TB Gold test was positive in 5 of the 49 subjects (10%); 3 of the 13 subjects (23.1%) in unknown status, 1 of the 8 subjects (13%) in LTBI, and 1 of the 21 subjects (5%) without infection. The agreement between the QuantiFERON-TB Gold and the TST was poor (${\kappa}=0.101$). Conclusion : QuantiFERON-TB Gold showed poor sensitivity for the diagnosis of LTBI in children with exposure to TB. QuantiFERON-TB Gold alone does not seem to be useful in the diagnosis of LTBI in children.

  • PDF

Comparison of Radiologic Parameters between Weight Bearing Affected Both Ankle and Single Ankle in Ankle Exam (체중부하 상태의 족관절 검사시 양측 족관절 동시 검사와 편측 족관절 검사의 방사선학적 비교)

  • Cha, Sangyoung;Shin, Jaehan;Choi, Namgil
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.603-610
    • /
    • 2016
  • This study was performed to analyze the results of radiologic parameters compared both leg weight bearing position to single leg weight bearing position in ankle osteoarthritis. Between January 2016 and June 2016, 25 patients (50 ankles) who visited our Hospital to treat ankle pain. In radiographic assessment, We masured tibial anterior surface angle(TAS), tibial medial malleolar angle(TMM), talar tilting angle(TT), joint space width(JSW), tibiotalar joint space, fibulotalar joint space of ankle as radiologic parameters. On the right leg of the both leg weight bearing position, TAS was $87.24^{\circ}$, TT was $6.44^{\circ}$, TMM was $26.76^{\circ}$, fibulotalar joint space was 0.98mm. Right leg of the single leg weight bearing position, TAS was $88.93^{\circ}$, TT was $2.41^{\circ}$, TMM was $19.77^{\circ}$, fibulotalar joint space was 1.6mm. And then, on the left leg of the both leg weight bearing position, TAS was $87.25^{\circ}$, TT was $5.71^{\circ}$, TMM was $23.92^{\circ}$, fibulotalar joint space was 1.22 mm and left leg of the single weight bearing position, TAS was 88.75, TT was $3.19^{\circ}$, TMM $21.45^{\circ}$, fibulotalar joint space was 1.22 mm. There are unsimilarity between measure values of TAS and tibiotalar joint space. As the result of test of weight bearing ankle study, it would be more exact to examine to measure one side in the first time rather than both to conclude on accurate measurement.