• 제목/요약/키워드: Measurement and Verification

검색결과 907건 처리시간 0.031초

원전 격납건물 누설시험용 무선데이터전송을 적용한 시험장치 개발 (Leakage Rates Measurement System Development of NPP Primary Containment using Wireless Data Communication Method)

  • 류재규;손창호;황희정;김건수;최경식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.916-919
    • /
    • 2003
  • In this paper, we deal with a development of measurement system to apply the leakage rates test of primary containment in nuclear power plant. The measurement test about leakage rates in primary containment is one sort of test to prove safety of nuclear power plant. The parameters which are measured to calculate leakage rates are drybulb temperature, dew point temperature(or relative humidity), absolute pressure and flow. Overall, the measurement system consists of sensor module for data acquisition of the parameters, transfer module for wireless data communication and control module to control system and to calculate leakage rates. Because existing measurement systems are difficult to set in field, we pursued convenience of use, we applied wireless data communication and individual form module using battery. We also changed for the better in confidence. Recently, we are developing a drybulb temperature and a dew point temperature sensor module. We describe about function of developed measurement system, its standard and an plan for verification of measurement system.

  • PDF

터빈유량계를 이용한 유량 측정 시스템의 최적 설계 (Optimal Design of Flow Measurement System Using Turbine Flowmeter)

  • 김홍탁;김부일
    • 한국전자통신학회논문지
    • /
    • 제13권1호
    • /
    • pp.77-84
    • /
    • 2018
  • 터빈유량계(Turbine flowmeter)는 유량 측정시 높은 정확도와 반복성을 위해 선택되지만 교정시의 표준 환경 조건과 현장에서의 환경 조건 차이로 다양한 측정 불확도 요인을 발생시킨다. 또한 교정된 측정값 외의 구간에서의 사용을 위해 신뢰성 높은 보간 기법(Interpolation method)이 필요하다. 따라서 본 논문에서는 유량 측정(Flow measurement) 신뢰성 향상을 위해 터빈유량계의 출력 신호의 정확한 측정과 교정된 결과값의 보간, 온도변화를 실시간 보정(correction)하는 장비를 설계 및 제작하고 성능 검증을 수행함으로 현장에서의 측정 신뢰도를 확보하였다.

기상측정시스템과 오차보정을 이용한 가공정밀도 향상 (Machining Accuracy Improvement by On Machine Part Measurement and Error Compensation)

  • 최진필;민병권;이상조
    • 한국정밀공학회지
    • /
    • 제20권12호
    • /
    • pp.34-41
    • /
    • 2003
  • This paper suggests a methodology fur improving the machining accuracy by compensating for the machining errors based on on-machine measurement process. Probing errors and machine tool errors included in the measurement data were calibrated or compensated to obtain the actual machining errors. Machine tool errors were modeled in forward and backward directions according to the axis movement direction to consider the effects of backlash errors on the measurement data, and model parameters were determined by measuring a cube array artifact. A rectangular workpiece was machined and then measured with a touch probe as a verification experiment. Machining experiments showed that the machining errors were reduced to within the designated tolerance after compensating for the actual machining errors by modifying the original footpath for the next-step machining.

한국형고속열차 고속 궤도검측시스템 (High Speed Rail Measurement System of HSR-350x)

  • 김상수;박춘수
    • 한국철도학회논문집
    • /
    • 제11권2호
    • /
    • pp.115-119
    • /
    • 2008
  • 고속선에서의 궤도틀림은 차량의 주행 안정성 및 소음, 진동 등에 큰 영향을 끼치는 요소이다. 차량의 흔들림을 억제하고 효율적인 선로의 점검 및 관리를 위해서는 정확하고, 고속의 궤도검측기구가 요구되고 있는 실정이다. 본 논문에서는 국내 기술로 제작된 한국형고속열차에 고속 궤도검측시스템을 구축하고, 시운전 시험을 통하여 검측된 궤도 검측 결과를 검토하고자 한다.

고속카메라를 이용한 전차선 압상량 검측 시스템 개발 (Development of an Uplift Measurement System for Overhead Contact Wire using High Speed Camera)

  • 박영;조용현;이기원;김형준;김인철
    • 한국전기전자재료학회논문지
    • /
    • 제22권10호
    • /
    • pp.864-869
    • /
    • 2009
  • The measurement of contact wire uplift in electric railways is one of the most important test parameters to accepting the maximum permitted speed of new electric vehicles and pantographs. The contact wire uplift can be measured over short periods when the pantograph passes monitoring stations. In this paper, a high-speed image measurement system and its image processing method are being developed to evaluate dynamic uplift of overhead contact wires caused by pantograph contact forces of Korea Tilting Train eXpress (TTX) and Korea Train eXpress (KTX). The image measurement system was implemented utilizing a high-speed CMOS (Complementary Metal Oxide Semiconductor) camera and gigabit ethernet LAN. Unlike previous systems, the uplift measurement system using high speed camera is installed on the side of the rail, making maintenance convenient. On-field verification of the uplift measurement system for overhead contact wire using high speed camera was conducted by measuring uplift of the TTX followed by operation speeds at the Honam conventional line and high-speed railway line. The proposed high-speed image measurement system to evaluate dynamic uplift of overhead contact wires shows promising on-field applications for high speed trains such as KTX and TTX.

해양시스템 모형실험을 위한 수중운동계측시스템 개발 연구 (Development of Underwater Motion Measurement System for Model Test of Ocean System)

  • 최종수;홍섭
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2004년도 학술대회지
    • /
    • pp.166-172
    • /
    • 2004
  • An underwater motion measurement system was constructed for applications to the model basin. A commercial motion capture system, FALCON of Motion Analysis Corp., which corrects automatically the distortion caused by refraction of the light passing through water and air, was adopted for underwater motion measurement. The modifications of FALCON system were performed: waterproofing camera housings, markers, connectors, and a new blue ring lighter. the accuracy of the motion measurement was obtained within the calibration error of 0.87mm in average and 0.89mm in standard deviation for the distance of 500mm between two markers on the calibration device. the volume of $2100mm(length)\times2100mm(breadth)\times2300mm(Height)$ was covered with 4 cameras of the underwater motion measurement system. For the performance verification, motion measurement test of a vertical mooring chain model excited at the top end was carried out. The 3D motions of mooring model were measured with variable amplitude and period of the forced excitation. Higher order motions of the mooring model were observed as the excitation period decreases. the performance of the system was verified by successfully measuring 3D motion of mooring model.

  • PDF

동적원심모형 시험을 이용한 부지응답해석 검증시 입력 지진의 결정 (Appropriate Input Earthquake Motion for the Verification of Seismic Response Analysis by Geotechnical Dynamic Centrifuge Test)

  • 이진선
    • 한국지진공학회논문집
    • /
    • 제17권5호
    • /
    • pp.209-217
    • /
    • 2013
  • In order to verify the reliability of numerical site response analysis program, both soil free-field and base rock input motions should be provided. Beside the field earthquake motion records, the most effective testing method for obtaining the above motions is the dynamic geotechnical centrifuge test. However, need is to verify if the motion recorded at the base of the soil model container in the centrifuge facility is the true base rock input motion or not. In this paper, the appropriate input motion measurement method for the verification of seismic response analysis is examined by dynamic geotechnical centrifuge test and using three-dimensional finite difference analysis results. From the results, it appears that the ESB (equivalent shear beam) model container distorts downward the propagating wave with larger magnitude of centrifugal acceleration and base rock input motion. Thus, the distortion makes the measurement of the base rock outcrop motion difficult which is essential for extracting the base rock incident motion. However, the base rock outcrop motion generated by using deconvolution method is free from the distortion effect of centrifugal acceleration.

인터넷 설문조사의 검증에 관한 사례연구 (A case study on verification of internet survey)

  • 류귀열;문영수
    • Journal of the Korean Data and Information Science Society
    • /
    • 제25권1호
    • /
    • pp.11-18
    • /
    • 2014
  • 연구의 목적은 인터넷 설문조사에서 자료의 정확성을 데이터베이스의 자료와 설문조사 자료의 비교를 통해 검정하는 것이다. 설문조사는 2012년 8월 한국과학기술정보연구원의 NDSL 원문이용자를 대상으로 실시하였으며, 검증에 이용된 변수는 나이, 소속기관의 인구통계적 변수와 이용빈도, 이용기간의 행동 변수이다 1차 검정결과 불일치 비율은 나이가 7.5%, 소속기관 15%, 이용빈도 92%, 이용기간 55%로 높게 나타났다. 상세검정을 통해 나이에 대한 불일치 비율을 비관적으로 3%, 낙관적으로 1%로, 소속기관에 대한 불일치 비율을 비관적으로 4.5%, 낙관적으로 2%로 추정할 수 있었다. 불일치비율을 1/4 이하로 대폭 축소시켰다. 이용빈도와 이용기간은 측정오차와 응답자의 기억력 문제, 인터넷 이용행태 등으로 불일치 비율이 높게 나타났다. 이러한 현상은 전통적 설문조사에도 간접적으로 적용될 수 있을 것이다. 본 연구의 결과는 인터넷 설문조사가 믿을만한 자료라는 점을 시사하고 있으며, 보다 정확한 검증을 위해 많은 후속 연구가 필요하다.

Experiment of proof-of-principle on prompt gamma-positron emission tomography (PG-PET) system for in-vivo dose distribution verification in proton therapy

  • Bo-Wi Cheon ;Hyun Cheol Lee;Sei Hwan You;Hee Seo ;Chul Hee Min ;Hyun Joon Choi
    • Nuclear Engineering and Technology
    • /
    • 제55권6호
    • /
    • pp.2018-2025
    • /
    • 2023
  • In our previous study, we proposed an integrated PG-PET-based imaging method to increase the prediction accuracy for patient dose distributions. The purpose of the present study is to experimentally validate the feasibility of the PG-PET system. Based on the detector geometry optimized in the previous study, we constructed a dual-head PG-PET system consisting of a 16 × 16 GAGG scintillator and KETEK SiPM arrays, BaSO4 reflectors, and an 8 × 8 parallel-hole tungsten collimator. The performance of this system as equipped with a proof of principle, we measured the PG and positron emission (PE) distributions from a 3 × 6 × 10 cm3 PMMA phantom for a 45 MeV proton beam. The measured depth was about 17 mm and the expected depth was 16 mm in the computation simulation under the same conditions as the measurements. In the comparison result, we can find a 1 mm difference between computation simulation and measurement. In this study, our results show the feasibility of the PG-PET system for in-vivo range verification. However, further study should be followed with the consideration of the typical measurement conditions in the clinic application.