• 제목/요약/키워드: Measurement and Verification

검색결과 907건 처리시간 0.031초

혼합효과가 DMA와 CPC를 이용한 입자분포 측정에 미치는 영향에 관한 연구 (Study on the Influence of Mixing Effect to the Measurement of Particle Size Distribution using DMA and CPC)

  • 이윤수;안강호;김상수
    • 대한기계학회논문집B
    • /
    • 제27권3호
    • /
    • pp.326-333
    • /
    • 2003
  • In the measurement using DMA and CPC in series, there is some time delay for particles classified in DMA to detect in CPC. During this time, the DMA time-response changes due to the velocity profile of sampling tube and the diffusion of particles in the volume that exists between the DMA exit and the detector of ultra-fine CPC. This is called mixing effect. In the accelerated measurement methods like the TSI -SMPS, the size distribution is obtained from the correlation between the time-varying electrical potential of the DMA and the corresponding particle concentrations sampled in DMA. If the DMA time -response changes during this delay time, this can cause the error of a size distribution measured by this accelerated technique. The kernel function considering this mixing effect using the residence time distribution is proposed by Russell et al. In this study, we obtained a size distribution using this kernel to compare to the result obtained by the commercial accelerated measurement system, TSI -SMPS for verification and considered the errors that result from the mixing effect with the geometric mean diameters of originally sampled particles, using virtually calculated responses obtained with this kernel as input data.

LSPIV를 이용한 표면유속 측정기법의 검증 및 적용 (Verification and Application of Surface-Velocity Measurement Method Using LSPIV)

  • 김영근;노영신;윤병만
    • 한국수자원학회논문집
    • /
    • 제37권2호
    • /
    • pp.155-161
    • /
    • 2004
  • 본 연구에서는 LSPIV기법의 효율성과 적용성을 검증하기 위해 유속검정용 전동기계를 이용한 검증실험을 통하여 LSPIV기법을 검증하였다. 검증을 실시한 후에 LSPIV기법을 실제하천에 적용하였다 대상하천으로는 경안천의 지류인 능원천과 곤지암천을 선택하였으며, 3차원 유속계 및 기존의 표면유속 측정에 사용해 왔던 전자파 표면유속계의 측정결과와 비교하였다. 본 연구를 통해 나타난 결과를 살펴보면 검증실험에 사용된 전동차의 결과값과 비교했을 때 LSPIV기법의 측정값은 5%이내의 오차로 잘 일치하는 경향을 나타냈으며, 실제하천에 적용하여 기존의 측정장치와 비교하였을 때에도 최대 8% 이내의 오차로 잘 일치하였다.

Verification of Core/Shell Structure of Poly(glycidyl methacrylate-co-divinyl benzene) Microspheres

  • Jin, Jeong-Min;Choi, Jin-Young;Lee, Kang-Seok;Choe, Soon-Ja
    • Macromolecular Research
    • /
    • 제17권5호
    • /
    • pp.339-345
    • /
    • 2009
  • The core/shell type structure of the highly crosslinked poly(glycidylmetharylate-co-divinylbenzene) microspheres prepared in the precipitation polymerization in acetonitrile was thoroughly verified by means of swelling, $^1H$ NMR, XPS, TEM and TGA measurements. In the XPS measurement, the higher the GMA content, the higher the oxygen content was observed, implying that the higher content of GMA is observed in the particle surface. The further verification of the core/shell structure of the poly(GMA-co-DVB) particles was carried out using $^1H$ NMR and TEM techniques, resulting in the poly(GMA-co-DVB) particles with the GMA rich-phase and DVB rich-phase. In overall, the poly(GMA-co-DVB) microspheres consist of a highly crosslinked DVB rich-phase in the core and slightly or non-crosslinked GMA rich-phase in the shell part due to the different reaction ratios between two monomers and self-crosslinking density of DVB.

광학렌즈 자동 검사용 지능형 로봇 비젼 시스템 개발 (Development of Intelligent Robot Vision System for Automatic Inspection of Optical Lens)

  • 정동연;장영희;차보남;한성현
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 춘계학술대회 논문집
    • /
    • pp.247-252
    • /
    • 2004
  • Developed shape awareness technology and vision technology for optical ten slant in this research and including external form state of lens for the performance verification developed so that can be good achieve badness finding. And, establish to existing reflex data because inputting surface badness degree of scratch's standard specification condition directly, and error designed to distinguish from product more than schedule error to badness product by normalcy product within schedule extent after calculate the error comparing actuality measurement reflex data md standard reflex data mutually. Developed system to smallest 1pixel unit though measuring is possible 1pixel as 3.7$\mu\textrm{m}$${\times}$3.7$\mu\textrm{m}$(0.1369${\times}$10/sub-1/$\textrm{mm}^2$) the accuracy to 10/sub-1/mm minutely measuring is possible performance verification and trust ability through an experiment prove.

  • PDF

말뚝 변위 측정시스템의 진동 평가에 의한 정확도 향상 대책 (A Measure for Improvement in Accuracy by Performance Evaluation of a DPRMs)

  • 최영삼;정진태;이계영;한창수
    • 대한기계학회논문집A
    • /
    • 제29권12권
    • /
    • pp.1653-1659
    • /
    • 2005
  • In this study, the performance of a DPRMs is evaluated and the measurement precision for the pile driving is presented. The DPRMs is a visual-measurement system for the pile rebound and the penetration movement using a high speed line-scan camera. The DPRMs generates the measurement deviation. It is caused by the strong impact for the pile driving. To reduce it, the vibration signal analysis about the pile driving is performed. As a result, it is confirmed that the tilting frequency of a camera-tripod structure corresponding to excitation frequency range of the ground is under 40Hz. Through the structure modification, the camera-tripod structure is redesigned to the model being free itself from the excitation frequency range of the ground. By the verification testing about the improvement effects, it is inspected that the tilting and measurement deviation of the redesigned DPRMs are reduced.

비틀림하중을 받는 기계구조물의 ESPI를 이용한 면내변위 측정에 관한 연구 (A Study on Measurement of In-Plane Displacement using ESPI in Mechanical Structure under torsional load)

  • 장석원;이학주;최은오;정찬희
    • 대한기계학회논문집A
    • /
    • 제26권4호
    • /
    • pp.693-700
    • /
    • 2002
  • Recently, the mechanical structures applied to many industrial products, especially in electronic products, appear to be miniaturized and complicated. This trend makes it difficult to analyze the stress distribution of those mechanical structures and generates new challenges for precise measurement of strain. In order to solve this measurement problem many optical measurement techniques have been suggested. Among those, the ESPI(Electronic Speckle Pattern Interferometry) has been considered as one of the most useful tools. But the shortage of recognition and difficulties of measurement have limited its industrial applications in spite of its excellent capabilities. Therefore in this study, not only the verification of the FEA result but the enhancement of industrial application of ESPI was tried by measuring the in-plane displacement of mechanical structure with ESPI, which is difficult to be measured with strain gauge.

Experimental verification and improvement of heat transfer tube local wall temperature measurement method

  • Jiabao Liu;Xiaxin Cao;Peixun Yang
    • Nuclear Engineering and Technology
    • /
    • 제55권12호
    • /
    • pp.4317-4328
    • /
    • 2023
  • To ensure the measuring accuracy of the wall temperature, the outer wall temperature measurement values by using three kinds of thermocouple welding methods were analyzed and evaluated in the paper, including single-point flush-mounted in the wall groove method, single-point insert-mounted in the wall groove, and outer surface direct welding method, based on the application of a tube-in-tube condensing heat exchanger. And the impacts of silver, tin, and thermal resistance adhesive as filling materials on wall temperature measurement were also investigated, and the results were compared to that obtained without filling materials. The results showed that the wall temperatures measured by the three welding methods were lower than the theoretically calculated value. And the wall temperature measured by the outer surface direct welding method was lowest under the same experimental conditions. The wall temperatures measured by single-point flush-mounted and insert-mounted in the wall groove methods were also affected by different welding filling materials. It was found that the greater the thermal resistance of filling materials, the smaller the heat loss. By analyzing the reasons for the low measured value of wall temperature, a new wall temperature measurement method was developed to improve the accuracy of the current measurement method. Meanwhile, the outer wall temperature measurement experiments of vertical and horizontal heat transfer tubes were carried out to validate and calibrate the improved outer wall temperature measurement method. The results showed that the average outer wall temperature deviation measured by the improved wall temperature measurement method ranged from - 0.82% to +2.29% for vertical tubes and - 4.75% to - 1.44% for horizontal tubes, and the improved measurement method had good measurement accuracy.

전 암컷 3배체 넙치(Paralichthys olivaceus)에 대한 효율적인 세포유전학 분석법 (Cytogenetic Analysis of All-Female Triploid Olive Flounder Paralichthys olivaceus for Ploidy Verification)

  • 고민균;정효선;이효빈;김동수
    • 한국수산과학회지
    • /
    • 제49권5호
    • /
    • pp.671-674
    • /
    • 2016
  • We cytogenetically analyzed a triploid King-Nupchi strain of the olive flounder Paralichthys olivaceus to define the simplest, most rapid, and most effective method of ploidy analysis in aquaculture farms. Female triploidy of the flounder King-Nupchi strain was induced by cold shock (3 min post-fertilization at 2-4℃ for 45 min). Triploid induction was confirmed by erythrocyte measurement (nuclear volume, 29.15±2.10 μm3); flow cytometry (2.14±0.03 pg/cell); chromosome count (3N=72); Ag-NOR banding; and silver staining. Silver staining of finned cells obtained using a solid tissue technique was the most effective method of ploidy verification.

병원 위탁급식 품질관리를 위한 품질평가도구 개발 (The Development of a Quality Measurement Tool for a Contract-Managed Hospital Foodservice)

  • 양일선;김현아;이영은;박문경;박수연
    • 대한지역사회영양학회지
    • /
    • 제8권3호
    • /
    • pp.319-326
    • /
    • 2003
  • The purposes of this study were: a) to develop the a quality measurement tool for the contract-managed hospital foodservice, and b) to evaluate their performance with the developed quality measurement tool, and c) to verify the reliability and validity of the quality measurement tool. The developed quality measurement tool comprised two parts, which were foodservice management and medical nutrition care service. The foodservice management part was classified into six functional categories which were Menu, Procurement and Storage, Production and Distribution, Facility and Utility, Sanitation and Safety, and Management and Evaluation. The medical nutrition care service part indicated the medical nutrition care provided. Quality measurement tool had 91 standards and 324 indicators. The quality measurement tools were distributed to the hospital foodservice manager employed by the foodservice company. The 324 indicators were measured by foodservice manager on the 5-Likert-type scales, and then adapted to a 100 point scale. The SPSS Ver. 11.0 was used for statistical analysis. The categories whose scores were evaluated as being high were Procurement', General Sanitation', Personal sanitation' and Waste' and the categories whose scores were evaluated as being low were Diet Order Manual', Standard Recipe', Appropriateness (Facility and Utility)', Check (Facility and Utility)'and Information Management'. All the categories of medical nutrition service were evaluated as having seriously low scores. Therefore, it was necessary for the contract-managed hospital foodservice to improve its performance in the area of medical nutrition care service. For the verification of the developed quality measurement tool, the reliability obtained by calculating Cronbach's α was 0.8747, and the content validity was also proved by scrutiny of the modification of the Professional group's techniques. (Korean J Community Nutrition 8(3) : 319∼326, 2003)

속도시간이력을 이용한 변위 추정 알고리즘에 관한 실험적 검증 (Experimental Verification of Displacement Estimation Algorithm using Velocity Time History)

  • 조성호;전준창;황선근;이희현
    • 한국안전학회지
    • /
    • 제30권4호
    • /
    • pp.99-105
    • /
    • 2015
  • In this study, displacement estimation algorithm, which is not requiring an absolute reference point unlike the conventional displacement measurement method, is developed using the geophone. To estimate displacement of the bridge, measured velocity time signal is integrated in the frequency domain. And, the estimated displacement is compared with the measured result using a conventional method. Based on the dynamic field test results, it was found that the estimated displacement by the present algorithm is similar to that of a conventional method. The displacement estimation algorithm proposed in this paper can be effectively applied to measure the displacement of a structure, which is difficult to install a displacement transducer at the fixed point.