• Title/Summary/Keyword: Measurement Way

Search Result 1,504, Processing Time 0.025 seconds

QoS Measurement Method of RTP/RTCP for Multimedia Service in BcN (BcN에서 멀티미디어 서비스를 위한 RTP/RTCP의 QoS 측정방법)

  • Lim Jae-Young;Kim Jeong-Ho
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2005.11a
    • /
    • pp.611-615
    • /
    • 2005
  • Having been multimedia services in BcN network, QoS is best important factor. This paper classify existing services and newly to be offered services, analyze quality criterion and measurement method for QoS guarantee in BcN, This paper investigate end-to-end quality criterion, classify measurement method existing and newly to be offered services, search quality criterion, introduce measurement method such as call success rate, packet loss rate, one-way delay, jitter and R-value for end-to-end quality measurement.

  • PDF

On the Method of Measuring the Mobility using the Microwave by the Hall Effect in the semiconductor (마이크로파를 이용하여 반도체내의 Hall에 의한 이동도측정방법)

  • 허영남
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.8 no.2
    • /
    • pp.54-62
    • /
    • 1983
  • The electric characteristics of semiconductor materials can be found by way of various methods, of which the measurement of the carrier mobility is thought to be of great importance. There exist some mobilty measurements, but the measurement based on Hall effect is the most widely uesd. In this paper is adopted the mobility measurement of semiconductor by the use of cylindrical eavity operated in the same shape as TE modes. It is hoped that the resultant values of measurement, the structure of measurement circut, cavity design and the raising of relevant problems may give much help to those who may interested in this field.

  • PDF

Development of 2 Division Illuminance Measurement Mobile Systems (차량을 이용한 2분할 조도측정시스템의 개발)

  • Jo, Deok-Soo;Lee, Chang-Mo;Jung, Seung-Gyun;Seok, Doe-Il;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.1
    • /
    • pp.1-6
    • /
    • 2008
  • It is important to grasp the accurate lighting level for appropriate maintenance of the road lighting equipment. It is developed 2 division illuminance measurement systems. This system has a small size and no need to block the way and achieves the speedy measurement and high accuracy data in automatically measurement. As a result, this system can save expense and time to measure roadway lighting.

A Study on Influencing Factors of Unit-Water Measurement method according to Electrostatic capacity (정전용량에 따른 단위수량 측정기법의 영향인자에 대한 실험적 연구)

  • We, Joon-Woo;Lee, Young-Jin;Kim, Jeong-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.232-233
    • /
    • 2013
  • The unit-water content in fresh concrete determines consistency, and play an important role in condensing the structure of concrete and enhancing the durability of concrete. The capacitance measurement method measure quickly unit-water content and is the best way to apply to construction site. In this study, the unit-water content of capacitance measurement method is estimated according to types and replacemment ratio of admixture. and the field application of capacitance measurement method is reviewed.

  • PDF

Measurement of Secondary Electron Emission Coefficient on Deposition Time of the Silicon Thin Films (실리콘박막의 증착시간에 따른 감마계수 측정법 개발)

  • Lee, Jung-Hui;Choi, Byoung-Jung;Yang, Sung-Chae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.330-331
    • /
    • 2006
  • Recently, plasma display panels (PDPs) are highlighted for the flat type display device. Therefore, much attention has been paid to secondary electron emission coefficient of the electrode protective material of PDPs. As PDPs is developing, the concern about secondary electron emission coefficient ($\gamma$) which is related with PDPs electrode protection material is increasing continually. So the concern about the way to how to measure secondary electron emission coefficient is on the rise. At present, the way to how to measure secondary electron emission coefficient is developed by some research groups, which is giving some research part's advance help. In this research, we have studied how to measure secondary electron emission coefficient which is related with various thin films more conveniently than previous measurement method. We studied the method of measurement of secondary electron emission coefficient (${\gamma}$) of amorphous silicon films by using Paschen's curve.

  • PDF

Study of an Estimation Method of Thrust Measurement Uncertainty for the Solid Rocket Motors (고체 추진기관의 추력측정불확도 추정 방법 연구)

  • Lee, Kyu Joon;Kwon, Younghwa;Lee, Young Won
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.24 no.3
    • /
    • pp.18-30
    • /
    • 2020
  • This study deals an estimation method of thrust measurement uncertainty in solid rocket motors. Guidelines of the force measurement uncertainty estimation have been provided by ISO, domestic and international organizations. However, all of them are described by focusing on the force calibration machines and force transducers with a conceptually-driven way. Thus the guidelines cannot be directly applicable to uncertainty estimation of calibration equation and its linear approximation, which are critical error sources in the thrust measurement. In this paper, the equations taking into account effects of both error sources are derived based on fundamental concepts of measurement uncertainty. These are applied to the real thrust measurement system where a relatively simple estimation method for the thrust measurement uncertainty is proposed.

One-Way Delay Estimation Using One-Way Delay Variation and Round-Trip Time (단방향 지연 변이와 일주 지연을 이용한 양단간의 단방향 지연 추정)

  • Kim, Dong-Keun;Lee, Jai-Yong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.1
    • /
    • pp.175-183
    • /
    • 2008
  • QoS-support technology in networks is based on measuring QoS metrics which reflect a magnitude of stability and performance. The one-way delay measurement of the QoS metrics especially requires a guarantee of clock synchronization between end-to-end hosts. However, the hosts in networks have a relative or absolute difference in clock time by reason of clock offsets. flock skews and clock adjustments. In this paper, we present a theorem, methods and simulation results of one-way delay and clock offset estimations between end-to-end hosts. The proposed theorem is a relationship between one-way delay, one-way delay variation and round-trip time And we show that the estimation error is mathematically smaller than a quarter of round-trip time.

  • PDF

Computer Vision Based Measurement, Error Analysis and Calibration (컴퓨터 시각(視覺)에 의거한 측정기술(測定技術) 및 측정오차(測定誤差)의 분석(分析)과 보정(補正))

  • Hwang, H.;Lee, C.H.
    • Journal of Biosystems Engineering
    • /
    • v.17 no.1
    • /
    • pp.65-78
    • /
    • 1992
  • When using a computer vision system for a measurement, the geometrically distorted input image usually restricts the site and size of the measuring window. A geometrically distorted image caused by the image sensing and processing hardware degrades the accuracy of the visual measurement and prohibits the arbitrary selection of the measuring scope. Therefore, an image calibration is inevitable to improve the measuring accuracy. A calibration process is usually done via four steps such as measurement, modeling, parameter estimation, and compensation. In this paper, the efficient error calibration technique of a geometrically distorted input image was developed using a neural network. After calibrating a unit pixel, the distorted image was compensated by training CMLAN(Cerebellar Model Linear Associator Network) without modeling the behavior of any system element. The input/output training pairs for the network was obtained by processing the image of the devised sampled pattern. The generalization property of the network successfully compensates the distortion errors of the untrained arbitrary pixel points on the image space. The error convergence of the trained network with respect to the network control parameters were also presented. The compensated image through the network was then post processed using a simple DDA(Digital Differential Analyzer) to avoid the pixel disconnectivity. The compensation effect was verified using known sized geometric primitives. A way to extract directly a real scaled geometric quantity of the object from the 8-directional chain coding was also devised and coded. Since the developed calibration algorithm does not require any knowledge of modeling system elements and estimating parameters, it can be applied simply to any image processing system. Furthermore, it efficiently enhances the measurement accuracy and allows the arbitrary sizing and locating of the measuring window. The applied and developed algorithms were coded as a menu driven way using MS-C language Ver. 6.0, PC VISION PLUS library functions, and VGA graphic functions.

  • PDF

Single Outlier Removal Technology for TWR based High Precision Localization (TWR 기반 고정밀 측위를 위한 단일 이상측정치 제거 기술)

  • Lee, Chang-Eun;Sung, Tae-Kyung
    • The Journal of Korea Robotics Society
    • /
    • v.12 no.3
    • /
    • pp.350-355
    • /
    • 2017
  • UWB (Ultra Wide Band) refers to a system with a bandwidth of over 500 MHz or a bandwidth of 20% of the center frequency. It is robust against channel fading and has a wide signal bandwidth. Using the IR-UWB based ranging system, it is possible to obtain decimeter-level ranging accuracy. Furthermore, IR-UWB system enables acquisition over glass or cement with high resolution. In recent years, IR-UWB-based ranging chipsets have become cheap and popular, and it has become possible to implement positioning systems of several tens of centimeters. The system can be configured as one-way ranging (OWR) positioning system for fast ranging and TWR (two-way ranging) positioning system for cheap and robust ranging. On the other hand, the ranging based positioning system has a limitation on the number of terminals for localization because it takes time to perform a communication procedure to perform ranging. To overcome this problem, code multiplexing and channel multiplexing are performed. However, errors occur in measurement due to interference between channels and code, multipath, and so on. The measurement filtering is used to reduce the measurement error, but more fundamentally, techniques for removing these measurements should be studied. First, the TWR based positioning was analyzed from a stochastic point of view and the effects of outlier measurements were summarized. The positioning algorithm for analytically identifying and removing single outlier is summarized and extended to three dimensions. Through the simulation, we have verified the algorithm to detect and remove single outliers.

Development of a Flow Rate Sensor Using 2-way Cartridge Valve (2-유로 카트리지 밸브를 이용한 유압용 유량 센서의 개발)

  • 홍예선;이정오
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.9
    • /
    • pp.2381-2389
    • /
    • 1993
  • In this paper the design and test results of a dynamic flow rate sensor was reported. This sensor comprises an 2-way cartridge valve as standard hydraulic component and a displacement sensor. Its working principle bases on the linear relationship between the flow rate and the piston displacement of 2-way cartridge valves under constant pressure drop. This principle is well known, however it is not easy to develop a flow rate sensor with the measurement range of 300 1/min, pressure loss of less than 8 bar at 300 1/min, maximum linearity error of less than $\pm$1% and the maximum rising time of 10 ms. This paper describes the design procedure of the flow rate sensor, the improvement procedure of static performance and test method and results of dynamic performance.