• Title/Summary/Keyword: Measurement View

Search Result 942, Processing Time 0.026 seconds

Investigation of Ag Migration from Ag Paste Bump in Printed Circuit Board (Ag Paste bump 구조를 갖는 인쇄회로기판의 Ag migration 발생 안전성 평가)

  • Song, Chul-Ho;Kim, Young-Hun;Lee, Sang-Min;Mok, Jee-Soo;Yang, Yong-Suk
    • Korean Journal of Materials Research
    • /
    • v.20 no.1
    • /
    • pp.19-24
    • /
    • 2010
  • The current study examined Ag migration from the Ag paste bump in the SABiT technology-applied PCB. A series of experiments were performed to measure the existence/non-existence of Ag in the insulating prepreg region. The average grain size of Ag paste was 30 nm according to X-ray diffraction (XRD) measurement. Conventional XRD showed limitations in finding a small amount of Ag in the prepreg region. The surface morphology and cross section view in the Cu line-Ag paste bump-Cu line structure were observed using a field emission scanning electron microscope (FE-SEM). The amount of Ag as a function of distance from the edge of Ag paste bump was obtained by FE-SEM with energy dispersive spectroscopy (EDS). We used an electron probe micro analyzer (EPMA) to improve the detecting resolution of Ag content and achieved the Ag distribution function as a function of the distance from the edge of the Ag paste bump. The same method with EPMA was applied for Cu filled via instead of Ag paste bump. We compared the distribution function of Ag and Cu, obtained from EPMA, and concluded that there was no considerable Ag migration effect for the SABiT technology-applied printed circuit board (PCB).

A Study on Simultaneous Adjustment of GNSS Baseline Vectors and Terrestrial Measurements

  • Nguyen, Dinh Huy;Lee, Hungkyu;Yun, Seonghyeon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.38 no.5
    • /
    • pp.415-423
    • /
    • 2020
  • GNSS (Global Navigation Satellite System) is mostly used for high-precise surveys due to its accuracy and efficiency. But this technique does not always fulfill the demanding accuracy in harsh operational environments such as urban canyon and forest. One of the remedies for overcoming this barrier is to compose a heterogeneous surveying network by adopting terrestrial measurements (i.e., distances and angles). Hence, this study dealt with the adjustment of heterogeneous surveying networks consisted of GNSS baseline vectors, distances, horizontal and vertical angles with a view to enhancing their accuracy and so as to derive an appropriate scheme of the measurement combination. Reviewing some technical issues of the network adjustments, the simulation, and experimental studies have been carried out, showing that the inclusion of the terrestrial measurements in the GNSS standalone overall increased the accuracy of the adjusted coordinates. Especially, if the distances, the horizontal angles, or both of them were simultaneously adjusted with GNSS baselines, the accuracy of the GNSS horizontal component was improved. Comparing the inclusion of the horizontal angles with those of the distances, the former has been more influential on accuracy than the latter even though the same number of measurements were employed in the network. On the other hand, results of the GNSS network adjustment together with the vertical angles demonstrated the enhancement of the vertical accuracy. As conclusion, this paper proposes a simultaneous adjustment of GNSS baselines and the terrestrial measurements for an effective scheme that overcomes the limitation of GNSS control surveys.

A Basic Study on the Estimation of Discharge Current Waveform and the Insulation Diagnosis by the Measurement of Electromagnetic Environment (전자환경 측정에 의한 방전전류 파형추정과 절연진단의 기초 연구)

  • Park, Gwang-Seo;Kim, Gi-Chae;Kim, Lee-Guk;Park, Won-Ju;Lee, Gwang-Sik
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.10
    • /
    • pp.492-499
    • /
    • 2002
  • This paper presents the method for an estimation of discharge current waveform in short gap discharge by radiated electromagnetic fields. The method of current waveform estimation is to use the one antenna method (single field method) with a measured electric or magnetic field at given field point by a time domain antenna. In order to verify the availability of the estimation theory, the discharge current waveform estimation was performed by one antenna methods using the measured electric fields of Wilson & Ma and compared with experiments. In addition diagnosis technique for power equipments is able to prevent from large accidents by finding signs of tile accidents before they happen. From the results of the estimation of discharge current, we have a possibility for the application of insulation diagnosis technique for power equipments using S$F_6$ gas. From this point of view, this paper simulated discharge progress and partial discharge by using needle-plan electrodes system in S$F_6$, studied the distribution of frequency spectrum of the radiated electromagnetic waves using a biconical antenna and a spectrum analyzer. From the experimental results of this study, according to the consideration of the mutual relation between frequency spectrum of the radiated electromagnetic waves and discharge progress, it was confirmed that detecting Partial discharge and estimating discharge progress in S$F_6$ could be Possible.

FLIP CHIP ON ORGANIC BOARD TECHNOLOGY USING MODIFIED ANISOTROPIC CONDUCTIVE FILMS AND ELECTROLESS NICKEL/GOLD BUMP

  • Yim, Myung-Jin;Jeon, Young-Doo;Paik, Kyung-Wook
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.6 no.2
    • /
    • pp.13-21
    • /
    • 1999
  • Flip chip assembly directly on organic boards offers miniaturization of package size as well as reduction in interconnection distances resulting in a high performance and cost-competitive Packaging method. This paper describes the investigation of alternative low cost flip-chip mounting processes using electroless Ni/Au bump and anisotropic conductive adhesives/films as an interconnection material on organic boards such as FR-4. As bumps for flip chip, electroless Ni/Au plating was performed and characterized in mechanical and metallurgical point of view. Effect of annealing on Ni bump characteristics informed that the formation of crystalline nickel with $Ni_3$P precipitation above $300^{\circ}C$ causes an increase of hardness and an increase of the intrinsic stress resulting in a reliability limitation. As an interconnection material, modified ACFs composed of nickel conductive fillers for electrical conductor and non-conductive inorganic fillers for modification of film properties such as coefficient of thermal expansion(CTE) and tensile strength were formulated for improved electrical and mechanical properties of ACF interconnection. The thermal fatigue life of ACA/F flip chip on organic board limited by the thermal expansion mismatch between the chip and the board could be increased by a modified ACA/F. Three ACF materials with different CTE values were prepared and bonded between Si chip and FR-4 board for the thermal strain measurement using moire interferometry. The thermal strain of ACF interconnection layer induced by temperature excursion of $80^{\circ}C$ was decreased with decreasing CTEs of ACF materials.

  • PDF

Effect of Acupuncture at the LU5(Reinforcement), LU10(Reduction) on the Pulsation Scale of Chon, Gwan and Chuk region using High Resolution Infrared Camera (척택.어제 침자가 고해상도 적외선 카메라로 관찰한 촌구맥 부위의 온도 Pulsation 변화에 미치는 영향 연구)

  • Na, Chang-Su;Jeon, Hyo-Sang;Kim, Jee-Hyun
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.2
    • /
    • pp.127-133
    • /
    • 2011
  • Arteria radialis is a branch of the brachial artery extending down the forearm around the wrist where it closes to skin surface. In the oriental medicine, the skin above arteria radialis has an important role because oriental medicine practitioners put their finger tips on the area, and diagnose patient's health conditions by feeling the pulsation of the arterial contraction. The finger tip diagnostic method relies on subjective decision of the practitioner; and there is a need to develop an objective diagnostic modality. The pulsation of the arterial contraction appears not only a movement on the site but also as temperature fluctuation due to pulsatile feeding of warmer blood. The goal of this study is to demonstrate a feasibility of using an infrared camera quantitatively to detect the temperature fluctuation on the skin. Clinical important three different areas, called chon, gwan, chuk, near a wrist where the arteria radialis reaches close to skin surface are marked with small pieces of surgical tape. A high-speed and high-resolution infrared camera with a 3 cm of field of view measures these areas for 10 second at 200 frames per second with a 320*240 pixel size. The pulsatile temperature fluctuation is calculated after passing a band pass filter to remove any stationary temperature over 10 second. The temperature fluctuation of a healthy male volunteer is measured at a room temperature as a control, and is compared with another measurement performed after 20 minutes staying in a room at a 40 degree Celsius. This comparison is repeated for three times, and indicates that the fluctuation increases after staying 20 minutes in the warm room. This increase becomes smaller when the person stays in the warm room with an acupuncture treatment that decreases body temperature. So that an objective diagnostics on the site may become feasible.

Analysis of Street Environment in Seoul by Introducing Index of Greenness in Streetscape (녹지량 지표로서 녹시율 개념을 도입한 서울시 가로 환경 특성 분석)

  • Cho Yong-Hyeon;Cheong Yong-Moon;Kim Kwang-Dong
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.34 no.1 s.114
    • /
    • pp.1-9
    • /
    • 2006
  • The purposes of this study are to develop the concept and the measurement method of IGS(Index of Greenness in Streetscape) and to analyze the present condition of street environments through field surveys of IGS in Seoul. IGS is a new index which directly expresses human's perceptions of plants in a street and defined as the area ratio of which leaves of plants occupy in an eye-level view of a person standing on the center line of a street. In practice, IGS can be calculated from a photograph taken from a center point of a street at about 1.5 meter height from the ground with single lens reflex camera equiped with 50mm standard lens. The photograph must have a special composition in a way that the center point of the photograph is positioning at the visual vanishing point of street center line. Then the IGS can be calculated by computing the percentage of the area covered with the plant leaves in the photograph. Types of streets in Seoul were classified according to road functions into 4 types. We performed field surveys and calculated IGSs from 300 sample sites in Seoul. Followings summarize some of study results. The average IGSs for arterial roads, highways, alleys and back streets are 16.91%, 16.33%, 13.97% and 7.50% respectively. The difference of average IGS values between Ginkgo biloba and Platanus occidentalis was relatively large. From observation IGSs from April 4th, 2003 to October 2nd, 2003, it was evident that the range and timing of each plant species' IGS change is not the same. According to questionnaire to public officials taking charge of street greening, the current evaluated IGS is 24.4%, and it is expected to be 40.7% in the future.

Measurement of Port Service Quality in Container Transport Logistics Using Importance -Performance Analysis: A Case of Busan Port

  • Ha, Min-Ho;Ahn, Ki-Myung
    • Journal of Navigation and Port Research
    • /
    • v.41 no.5
    • /
    • pp.353-358
    • /
    • 2017
  • This study aims to propose an assessment tool of port service quality (PSQ) in the context of container transport logistics (CTLs), by taking the perspectives from port users. The CTLs defined in this study are the relevant activities of serving the physical flows of a container box from a point of origin via a container port to a point of destination. To address the ports' role in collaboration between its channel members in CTLs, the PSQ measures for all port user groups (i.e. common PSQ measures) are selected based on the relevant CTLs activities involved by port, and its users within terminal/port area as well as throughout the CTLs chain. An importance-performance analysis (IPA) is applied as a diagnostic tool to analyse the status quo of Busan Port in CTLs contexts, by comparing the importance and performance (IP ) scores against each individual CTLs criterion. The findings from the IPA reveal that port managers and policy makers at the Busan Port should concentrate on six PSQ measures (i.e. SR1, SR4, ITS1, VAS1, VAS4, ICI3) to enhance PSQ in CTLs. However, four measures (i.e. ITS2, ITS3, ITS4, VAS2) are identified as a possible overkill, indicating an area of inefficiency where a remedial action of the cost-cutting decision is necessary. On the other hand, the Busan port shows an outstanding performance on four measures such as SR2, SR3, ICI1 and ICI2. The measures are not only important but also high performance. The study findings provide managerial guidance to port managers in Busan Port, in view of searching for managerial and operational strategies for sustainable port growth.

Hydrophilic property by contact angle change of ion implanted polycarbonate (이온주입 Polycarbonate의 접촉각 변화에 의한 친수특성)

  • Lee, Chan-Young;Lee, Jae-Hyung;Lim, Kee-Joe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.533-538
    • /
    • 2003
  • It has been shown that ion implantation produces remarkable improvements in surface-sensitive physical and chemical properties as well as other mechanical properties, in polymers. In this study, ion implantation was performed onto polymer, PC(polycarbonate), in order to investigate surface hydrophilic property through contact angle measurement using distilled water. PC was irradiated with N, Ar, Xe ions at the irradiation energy of $20\;{\sim}\;50keV$ and the dose range of $5{\times}10^{15},\;1{\times}10^{16},\;7{\times}10^{16}\;ions/cm^2$. The contact angle of water has been reduced with increasing fluence and ion mass but increased with increasing implanted energy. The changes of chemical and structural property are discussed in view of infrared spectroscopy and FT-IR, XPS, which shows increasing C-O bonding and C-C bonding. The root mean square of surface roughness examined by means of AFM changed smoothly from 0.387nm to 0.207nm and the change of wettability was discussed with respect to elastic and inelastic collisions obtained as results of TRIM simulation. It was found that wettability of the modified PC surface was affected on change of functional group and nuclear stopping or linear energy transfer(LET, energy deposited per unit track length per ion) that causes chain scission by displacing atom from polymer chains, but was not greatly dependant on surface morphology.

  • PDF

Measurement of Photo-Neutron Dose from an 18-MV Medical Linac Using a Foil Activation Method in View of Radiation Protection of Patients

  • Yucel, Haluk;Cobanbas, Ibrahim;Kolbasi, Asuman;Yuksel, Alptug Ozer;Kaya, Vildan
    • Nuclear Engineering and Technology
    • /
    • v.48 no.2
    • /
    • pp.525-532
    • /
    • 2016
  • High-energy linear accelerators are increasingly used in the medical field. However, the unwanted photo-neutrons can also be contributed to the dose delivered to the patients during their treatments. In this study, neutron fluxes were measured in a solid water phantom placed at the isocenter 1-m distance from the head of an18-MV linac using the foil activation method. The produced activities were measured with a calibrated well-type Ge detector. From the measured fluxes, the total neutron fluence was found to be $(1.17{\pm}0.06){\times}10^7n/cm^2$ per Gy at the phantom surface in a $20{\times}20cm^2$ X-ray field size. The maximum photo-neutron dose was measured to be $0.67{\pm}0.04$ mSv/Gy at $d_{max}=5cm$ depth in the phantom at isocenter. The present results are compared with those obtained for different field sizes of $10{\times}10cm^2$, $15{\times}15cm^2$, and $20{\times}20cm^2$ from 10-, 15-, and 18-MV linacs. Additionally, ambient neutron dose equivalents were determined at different locations in the room and they were found to be negligibly low. The results indicate that the photo-neutron dose at the patient position is not a negligible fraction of the therapeutic photon dose. Thus, there is a need for reduction of the contaminated neutron dose by taking some additional measures, for instance, neutron absorbing-protective materials might be used as aprons during the treatment.

The Effects of Scapular Stabilization Exercise before Rotator Cuff Repair on Pain and ROM of Middle-aged Women (중년여성의 가시위근 봉합술전 어깨뼈 안정화운동이 통증과 ROM향상에 미치는 영향)

  • Kim, Taeyeob;Yoo, Byungkook
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.2 no.1
    • /
    • pp.63-76
    • /
    • 2014
  • Purpose : The purpose of this study was to ascertain the effects of scapular stabilization exercise before rotator cuff surgery on pain and range of motion of middle-aged women. Method : 20 subjects who agreed on this experiment and were diagnosed with rotator cuff rupture participated in this study. Experimental groups were treated while 40 minutes a day, 5 times per week, for 2 weeks before surgery. The effects of scapular stabilization exercise were evaluated on VAS and range of motion. Collected data were analyzed with SPSS for windows ver. 20.0 program. One-way repeated ANOVA was used to examine a significance of each variable by time. Two-way repeated ANOVA was applied to examine a significance of the experimental group against the control group. In all statistical tests, the significance level was set by ${\alpha}=.05$. Result : The results of this study are as follows: 1) In both control and experimental groups, VASs were decreased significantly according to intervention period. There was no significant difference between VASs of two groups. 2) In both control and experimental groups, ROMs of shoulder, flexion, abduction and external rotation were increased significantly according to intervention period. In these three flexibility measurement variables, there were significant differences between ROMs of two groups. Conclusion : In view of all the results in this study, scapular stabilization exercise on before rotator cuff surgery proved to be effective in improving their pain, range of motion after surgery. It will be sufficient data to perform with their own exercise program.