• Title/Summary/Keyword: Measurement View

Search Result 942, Processing Time 0.029 seconds

Methodology for Measuring the Quality of Three-Dimensional Television (3차원 텔레비전의 품질측정 방법론)

  • Byun, Dae-Ho
    • Journal of Digital Convergence
    • /
    • v.10 no.4
    • /
    • pp.1-9
    • /
    • 2012
  • Emerging three-dimensional television (3DTV) as a new IT product shows a possibility that television is not for just watching broadcasting, but an attractive tool for applying it to our real life. Three dimensional television is generally more effective and attractive than two-dimensional television (2DTV). But it still needs continuous technological improvement to solve its inherent limitations until many customers decide to purchase 3DTVs without hesitation. Innovative products like 3DTV encounter a quality problem leading purchase decision by customers. Quality is regarded as one of the most important factors affecting customers to adopt and use the product. Furthermore, measuring quality effectively is considerable for the 3DTV research. In this paper, we suggest the Analytic Hierarchy Process(AHP) method for evaluating 3DTVs in a view of quality. We describe quality criteria affecting the 3DTV selection through a literature survey and develope an analytical method for measuring quality. We classify the quality of 3DTV into four types and suggest a concept of the quality ratio as a measurement criteria instead of the quality gap. Though a numerical example, we show how priorities of 3DTV with versatile manufacturers is computed.

Method for Selecting a Three Dimensional Television (3차원 텔레비전의 제품선정 방법)

  • Byun, Dae-Ho
    • Journal of Digital Convergence
    • /
    • v.11 no.3
    • /
    • pp.41-48
    • /
    • 2013
  • Emerging three-dimensional television (3DTV) as a new IT product shows a possibility that television is not for just watching broadcasting, but an attractive tool for applying it to our real life. Three dimensional television is generally more effective and attractive than two-dimensional television (2DTV). But it still needs continuous technological improvement to solve its inherent limitations until many customers decide to purchase 3DTVs without hesitation. Innovative products like 3DTV encounter a quality problem leading purchase decision by customers. Quality is regarded as one of the most important factors affecting customers to adopt and use the product. Furthermore, measuring quality effectively is considerable for the 3DTV research. In this paper, we suggest the Analytic Hierarchy Process(AHP) method for evaluating 3DTVs in a view of quality. We describe quality criteria affecting the 3DTV selection through a literature survey and develope an analytical method for measuring quality. We classify the quality of 3DTV into four types and suggest a concept of the quality ratio as a measurement criteria instead of the quality gap. Though a numerical example, we show how priorities of 3DTV with versatile manufacturers is computed.

Development of Online Speller using Non-contact Blink Detection Glasses (비접촉 눈 깜박임 측정 안경형 디바이스를 이용한 실시간 스펠러의 구현)

  • Lee, Jeong Su;Lee, Hong Ji;Lee, Won Kyu;Lim, Yong Gyu;Park, Kwang Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.6
    • /
    • pp.283-290
    • /
    • 2015
  • We proposed blink based online speller for the locked-in syndrome (LIS) patients, paralyzed in nearly all voluntary muscles expect for the eyes, with a simple and easy-to-use eye blink detection glasses. Electrooculogram (EOG) is the golden standard method of eye movement or blink measurement with Ag/AgCl electrodes. However, this method has several drawbacks such as skin irritation and dehydration of conductive gel. To resolve the shortcomings, we used a blink detection system based on a transparent capacitively coupled electrode, which is conductive indium tin oxide (ITO) films. The films make it possible to measure eye blink without direct skin contact and obstruction of field of view. We finally developed user-friendly blink based online speller with the blink detection system. To classify voluntary and non-voluntary blink, we used the double blink for command of the speller. The online speller experiment result with six healthy subjects shows that mean accuracy is 98.96% and letter per minute (LPM) is 4.73, which are better result by comparison with conventional P300 or auditory brain-computer interface (BCI) paradigm. The result of the experiment demonstrates the possibility of applying the proposed system as a communication method for the LIS patients.

A Statistical Model for the Ultra-Wide Bandwidth Indoor Apartment Channel (실내 아파트 환경에서의 통계적 UWB 채널 모델)

  • Park Jin-Hwan;Lee Sang-Hyup;Bang Sung-Il
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.9 s.339
    • /
    • pp.19-28
    • /
    • 2005
  • We establish a statistical model for the ultra-wide bandwidth (UMB) indoor channel based on over 2000 frequency response measurements campaign in a Practical apartment. The approach is based on the investigation of the statistical properties of the multipath profiles measured in different place with different rooms. Based on the experimental results, a characterization of the propagation channel from theoretic view point is described. Also we describe a method for measurement of the channel impulse response and channel transfer function. Using the measured data, the authors compares channel impulse responses obtained from time-domain and channel transfer functions obtained from frequency-domain with statistical path loss model. The bandwidth of the signal used in this experiment is from 10MHz to 8.01 GHz. The time-domain results such as maximum excess delay, men excess delay and ms delay spread are presented. As well as, omni-directional biconical antenna were used for transmitter and receiver In addition, measurements presented here support m channel model including the antenna characteristics.

First Light of the MIRIS, a Compact Wide-field Space IR Telescope

  • Han, Wonyong;Lee, Dae-Hee;Jeong, Woong-Seob;Park, Youngsik;Moon, Bongkon;Park, Sung-Joon;Pyo, Jeonghyun;Kim, Il-Joong;Park, Won-Kee;Lee, Duk-Hang;Seon, Kwang-Il;Nam, Uk-Won;Cha, Sang-Mok;Park, Kwijong;Park, Jang-Hyun;Yuk, In-Soo;Ree, Chang Hee;Jin, Ho;Yang, Sun Choel;Park, Hong-Young;Shin, Ku-Whan;Suh, Jeong-Ki;Rhee, Seung-Wu;Park, Jong-Oh;Lee, Hyung Mok;Matsumoto, Toshio
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.1
    • /
    • pp.49.2-49.2
    • /
    • 2014
  • The MIRIS (Multi-purpose InfraRed Imaging System) is a compact IR space Telescope, which has been developed by KASI since 2008 as the main payload of Korean STSAT-3. It was launched successfully by a Dnepr Rocket at Yasny Launch site, Russia in November 2013. After the launch, the STSAT-3 successfully settled down at Sun synchronous orbit with altitude of ~ 600km. Communications were regularly made between the ground station and the MIRIS with other secondary payload. We made a series of tests of the MIRIS during the verification period and found that all functions including the passive cooling are working as expected. The MIRIS has a wide-field of view $3.67{\times}3.67$ degrees and wavelength coverage from 0.9 to 2.0 micro-meter with the angular resolution of 51.6 arcsec. The main science missions of the MIRIS are (1) mapping of the Galactic plane with Paschen-alpha line (1.88 micro-meter) for the study of warm interstellar medium and (2) the measurement of large angular fluctuations of cosmic near infrared background radiation with I (1.05 micro meter) and H (1.6 micro meter) bands to identify their origin. We present the results of MIRIS initial operation in this paper.

  • PDF

Study on methodology for the assessment of internal and marginal adaptation on fixed dental prosthesis (고정성 보철물의 내면 및 변연적합도를 평가하는 방법에 대한 고찰)

  • Pyo, Se-Wook;Lee, Jun-Jae;Han, Jung-Suk;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.158-168
    • /
    • 2016
  • This article is to review various methods used to investigate internal and marginal adaptation of fixed dental prostheses, and to summarize a merit, worth, and limitation of each method, using some results of previous studies. The methods of measuring internal and marginal gap are divided into two categories in this study; in vivo and in vitro. In vivo methods are clinical evaluations, including exploration, radiography, and impression technique. In vitro methods are laboratory evaluations such as direct view, cross-sectioning, and silicone replica technique using microscope. Measuring by micro computed tomography (CT) or profilometer is also in vitro methods. In recent years, the development of scanning systems is able to analyze 3-dimensional internal and marginal space in detail. As measuring and analyzing technology become more advanced, the ability to thoroughly examine crown adaptation is becoming both simpler and more efficient.

An Electrochemical Study on Corrosion Property of Repair Welding Part for Exhaust Valve (배기밸브 보수 용접부의 부식 특성에 관한 전기화학적 연구)

  • Moon, Kyung-Man;Lee, Kyu-Hwan;Cho, Hwang-Rae;Lee, Myung-Hoon;Kim, Yun-Hae;Kim, Jin-Gyeong
    • Journal of Ocean Engineering and Technology
    • /
    • v.22 no.3
    • /
    • pp.82-88
    • /
    • 2008
  • The diesel engine of the merchant ship has been aperated in severe environments more and more, because the temperature of the exhaust gas of a combustion chamber is getting higher and higher with increasing use of heavy oil of law quality, due to the significant increase in the price of oil in recent some years. As a result, the degree of wear and corrosion between exhaust valve and seat ring is more serious compared to other engine parts. Thus the repair welding of exhaust valve and seat ring is a unique method to prolong the life of the exhaust valve, from an economical point of view. In this study, the corrosion property of both weld metal and base metal was investigated using electrochemical methods such as measurement of corrosion potential, cathodic and anodic polarization curves, cyclic voltammogram, and polarization resistance in 5% H2SO4 solution. The test specimen was a part of an exhaust valve stem being welded as the base metal, using various welding methods. In all cases, the corrosion resistance as well as hardness of the weld metal zone was superior to the base metal. In particular, plasma welding showed relatively good properties for both corrosion resistance and hardness, compared to other welding methods. In the case of DC SMAW (Shielded metal arc welding), corrosion resistance of the weld metal zone was better than that of the base metal, although its hardness was almost same as the base metal.

A Study on Improvement of Lighting Environment of Night-Scape in Anyang-si (안양시 야간경관 조명환경 개선방향에 관한 연구)

  • Park, Joo-Young;Oh, Min-Seok;Kim, Hway-Suh
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.2
    • /
    • pp.27-35
    • /
    • 2009
  • This study aimed to find problems of nightscape of Anyang-si through examination of behavioral pattern at night and measurement of illumination and luminance in accordance with regional classification following 6 regional classifications on the basis of ur1xm characteristic of Anyang-si. Basic concept of nightscape creation was application of improvement plan with analysis of regional problems and creation of artistic value to enhance image of Anyang-si as a city of art. To obtain balance and unity of night illumination, concept of light zoning was applied to smooth-transform method by regions. Especially, right to view harmonized with surrounding scenery was secured through creating gradual skyline compatible with neighbor buildings using division of each buildings according to their heights. In addition, way to improvement of night lighting environment was proposed as to illumination, height, type of lamp and arrangement of street lights and furniture in accordance with regional characteristics.

Investigation of Masking Based Side Channel Countermeasures for LEA (LEA에 대한 마스킹 기반 부채널분석 대응기법에 관한 분석)

  • Kim, ChangKyun;Park, JaeHoon;Han, Daewan;Lee, Dong Hoon
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.26 no.6
    • /
    • pp.1431-1441
    • /
    • 2016
  • In case of ARX based block cipher algorithms with masking countermeasures, there is a need for a method to convert between Boolean masking and arithmetic masking. However, to apply masking countermeasures to ARX based algorithms is less efficient compared to masked AES with single masking method because converting between Boolean and arithmetic masking has high computation time. This paper shows performance results on 32-bit platform implementations of LEA with various masking conversion countermeasures against first order side channel attacks. In the implementation point of view, this paper presents computation time comparison between actual measurement value and theoretical one. This paper also confirms that the masked implementations of LEA are secure against first order side channel attacks by using a T-test.

Fabrication of $SnO_2$ Gas Sensor added by Metal Oxide for DMMP (DMMP 검출용 금속산화물을 첨가한 $SnO_2$ 가스센서 제조)

  • 최낙진;반태현;곽준혁;백원우;김재창;허증수;이덕동
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.54-61
    • /
    • 2003
  • $SnO_2$ gas sensor for the detection DMMP, simulant of nerve gas was fabricated and its characteristics were examined. Sensing materials were $SnO_2$ added by TEX>$\alpha$-$Al_{2}O_{3}$ with 0∼20wt.% and $In_{2}O_{3}$ with 0∼3wt.% and were physically mixed each material. They were deposited by screen printing method on alumina substrate. The sensor was consisted of sensing electrode with interdigit(IDT) type in front and a heater in back side. Its dimension was 7$\times$10$\times$0.6$\textrm{mm}^2$. Crystallite size 8t phase identification, specific surface area and morphology of fabricated $SnO_2$ powders were analyzed by X-ray diffraction(XRD), surface area analyzer(BET) and by a scanning electron microscope(SEM), respectively. Sensor was measured as flow type and sensor resistance change was monitored as real time using LabVIEW program. The best sensitivities were 75% at adding 4wt.% TEX>$\alpha$-$Al_{2}O_{3}$, operating temperature $300^{\circ}C$ and 87% at adding 2wt.% $In_{2}O_{3}$, operating temperature $350^{\circ}C$ to DMMP 0.5ppm. Response and recovery times were about 1 and 3 min., respectively. Repetition measurement was very good with $\pm$3% in full scale. As a result, operating temperature was lower TEX>$\alpha$-$Al_{2}O_{3}$ than $In_{2}O_{3}$, but sensitivity was higher $In_{2}O_{3}$ than $\alpha$-$Al_{2}O_{3}$.