• Title/Summary/Keyword: Measurement Unit

Search Result 1,722, Processing Time 0.028 seconds

An Experimental Study on the Evaluation of Unit-Water Content Acoording to Concrete Aggregate Variables through FDR Sensor (FDR 센서를 통한 콘크리트 골재 변수에 따른 단위수량 평가에 관한 실험적 연구)

  • Youn, Ji-Won;Yu, Seung-Hwan;Yang, Hyun-Min;Yoon, Jong-Wan;Park, Tae-Joon;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.70-71
    • /
    • 2021
  • The unit quantity that affects the workability, shrinkage cracking, and durability of concrete is an important factor. Methods for measuring the unit quantity include a high frequency heating method, a capacitance method, a unit volume mass method, and a simple method. However, these methods have the disadvantage of poor measurement method, time required, and precision. To solve this problem, a relatively simple and fast measurement method was adopted to compensate for the shortcomings through a Frequency Domain Reflection (FDR) sensor, and the unit quantity was used. In addition, the measurement data was analyzed by deep learning to evaluate the unit quantity of concrete.

  • PDF

New Standards for Measurement in Meridians & Acupoints by Taking the Size of Normal Male Legs (정상 성인 남자(男子) 하지부위(下肢部位)의 수혈(?穴) 정위(定位)를 위한 도량형(度量衡) 산출)

  • Yu, Shin-Jong;Kwon, Oh-Sang;Ahn, Seong-Hoon;Kim, Young-Jin;Kim, Kyung-Sik;Sohn, In-Chul;Kim, Jae-Hyo
    • Journal of Pharmacopuncture
    • /
    • v.13 no.1
    • /
    • pp.93-101
    • /
    • 2010
  • Objective : Standard of measurement in Korean Medicine has been changed in dynasty and location. Thus, cun (寸) and chi (尺) as unit of measurement for meridians and acupoints could be recognized as the length of equally divided portions of a certain long bone or the distance between two anatomical landmarks and as an symbolical meaning to date. The goal of this study is to propose a new standard measurement in the metric system for the relative measurement of cun and chi as unit of measurement for meridians and acupoints in normal male legs. Methods : This study was conducted by gauging each parts of normal male legs in the metric system and comparing to the relative measurement of cun and chi as follows; to calculate 1 cun, the length of each parts was divided into the unit of cun referred to Measurement of the Bone in Neijing Lingshu (靈樞 骨度篇); it was compared the unit of cun referred to Measurement of the Bone in Neijing Lingshu with cun which was calculated by dividing subject's height into 75 cun, respectively. Result : There has no significant difference in length of 1 cun among each leg's areas based on a standard of subject's height. The unit of cun by the metric length in the legs was similar to the unit of cun referred to Measurement of the Bone in Neijing Lingshu based on each subject's height. Conclusion : It is suggested that an unit of cun as the measurement for meridians and acupoints in the male legs should be considered to the ranges from 2.4cm to 2.6cm.

A Study on the Investigation of Performance for Evaluation Method of Unit Water Content of Fresh Concrete (굳지 않은 콘크리트 단위수량 추정기법의 성능 검토에 관한 연구)

  • Kim, Yong-Ro;Choi, Il-Ho;Jung, Yang-Hee;Kim, Hyo-Rak;Lee, Do-Bum
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.367-370
    • /
    • 2005
  • In this study, air meter method and capacitance measurement method to apply economically at quality control of ready-mixed concrete among various unit water content measurement technique was selected. Then, it was evaluated estimating performance of unit water content according to the change of water-binder ratio and unit water content. Also, it was examined influence about error occurrence of unit water content by change of properties of used materials. Finally, based on this study, it was proposed fundamental data to utilize measurement technique of unit water content to quality control. of ready-mixed concrete in construction field.

  • PDF

Study on establish for unit of measure for Quality Feature (품질 특성의 측정에 대한 연구)

  • Ree, Sang-Bok
    • Proceedings of the Korean Society for Quality Management Conference
    • /
    • 2010.04a
    • /
    • pp.356-363
    • /
    • 2010
  • In this Paper, We study on establish for unit of measure. Quality means abstract for customer needs. we surveyed unit of measurement of quality feature of Juran, Taguchi, 6 sigma method. We suggest unit of measurement of quality feature. Each enterprise can use defining own unit of measurement of quality feature. Effect is expected in enterprise that these proposals do quality control. There is meaning in direction that measuring mean of quality feature that propose in this treatise understands actuality to be deeply and reconcile exact point of theory.

  • PDF

Study on establish for unit of measure for Quality Feature (다구찌의 품질특성 측정에 대한 고찰과 사례 연구)

  • Park, No-Guk;Lee, Sang-Bok
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2013.04a
    • /
    • pp.163-172
    • /
    • 2013
  • In this Paper, We study on establish for unit of measure. Quality means abstract for customer needs. we surveyed unit of measurement of quality feature of Juran, Taguchi, 6 sigma method. We suggest unit of measurement of quality feature. Each enterprise can use defining own unit of measurement of quality feature. Effect is expected in enterprise that these proposals do quality control. There is meaning in direction that measuring mean of quality feature that propose in this treatise understands actuality to be deeply and reconcile exact point of theory.

  • PDF

Study on establish for unit of measure for Quality Feature (품질 특성의 측정에 대한 분석 사례 연구)

  • Lee, Hui-Chun;Park, No-Guk;Lee, Sang-Bok
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2011.11a
    • /
    • pp.157-165
    • /
    • 2011
  • In this Paper, We study on establish for unit of measure. Quality means abstract for customer needs. we surveyed unit of measurement of quality feature of Juran, Taguchi, 6 sigma method. We suggest unit of measurement of quality feature. Each enterprise can use defining own unit of measurement of quality feature. Effect is expected in enterprise that these proposals do quality control. There is meaning in direction that measuring mean of quality feature that propose in this treatise understands actuality to be deeply and reconcile exact point of theory.

  • PDF

Calculation of Composite Desirability Function According to the Measurement Unit and Numerical Pattern of Characteristics in the Multiple Response Analysis (MRA에서 특성값의 측정단위와 수치형태에 따른 종합 만족도 산출 방법)

  • Choi, Sung-Woon
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2009.11a
    • /
    • pp.565-572
    • /
    • 2009
  • This paper presents the optimization steps with weight and importance of estimated characteristic values in the multiresponse surface analysis(MRA). The research introduces the shape parameter of individual desirability function for relaxation and tighening of specification bounds. The study also proposes the combinded desirability function using arithmetic, geometric and harmonic means considering the measurement unit and numerical pattern.

  • PDF

A New Measurement Unit for Quality control in Venture Business (벤처기업을 위한 새로운 품질관리 측정단위의 개발)

  • Ree, Sang-Bok;Park, Roh-Gook
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.6 no.2
    • /
    • pp.13-24
    • /
    • 2011
  • In this Paper, We study on establish for unit of measure. Quality control is means control for customer needs. We surveyed unit of measurement of quality feature of Juran and Taguchi teaching. We suggest new measure of quality feature. New quality measure which is combined with several quality control measures. Which measurement can be used management control of managerial level of company. We expect this new measurements can be applied and well used.

  • PDF

Development of an AFM-Based System for Nano In-Process Measurement of Defects on Machined Surfaces (가공면미세결함의 나노 인프로세스 측정을 위한 AFM시스템의 개발)

  • Gwon, Hyeon-Gyu;Choe, Seong-Dae;Park, Mu-Hun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.3
    • /
    • pp.537-543
    • /
    • 2002
  • This paper examines a new in-process measurement system for the measurement of micro-defects on the surfaces of brittle materials by using the AFM (Atomic Force Microscopy). A new AFM scanning stage that can also perform nano-scale bending of the sample was developed by adding a bending unit to a commercially available AFM scanner. The bending unit consists of a PZT actuator and sample holder, and can perform static and cyclic three-point bending. The true bending displacement of the bending unit is approximately 1.8mm when 80 volts are applied to the PZT actuator. The frequency response of the bending unit and the stress on the sample were also analyzed, both theoretically and experimentally. Potential surface defects of the sample were successfully detected by this measurement system. It was confirmed that the number of micro-defects on a scratched surface increases when the surface is subjected to a cyclic bending load.

Testing for a Unit Root in an ARIMA(p,1,q) Signal Observed with Measurement Error

  • Lee, Jong-Hyup;Shin, Dong-Wan
    • Journal of the Korean Statistical Society
    • /
    • v.24 no.2
    • /
    • pp.481-493
    • /
    • 1995
  • An ARIMA signal observed with measurement error is shown to have another ARIMA representation with nonlinear restrictions on parameters. For this model, the restricted Newton-Raphson estimator(RNRE) of the unit root is shown to have the same limiting distribution as the ordinary least squares estimator of the unit root in an AR(1) model tabulated by Dickey and Fuller (1979). The RNRE of parameters of the ARIMA(p,1,k) process and unit root tests base on the RNRE are developed.

  • PDF