• Title/Summary/Keyword: Measurement Quality

Search Result 4,470, Processing Time 0.031 seconds

A Study on Wireless Data Quality Measurement Method for u-Healthcare Service in HSDPA Environment (HSDPA 환경에서의 u-Healthcare 서비스를 위한 무선 데이터 품질 측정 방안 연구)

  • Yun, Sung-Yeol;Park, Seok-Cheon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.6
    • /
    • pp.127-134
    • /
    • 2011
  • Recently, the wireless data communication infrastructure appearing before the footlights crosses the limit in the wire and develop into the fast speed. Particularly, the issue about the u-Healthcare service using this increases. And the investigation of the quality guarantee of the wireless data network is important for the smooth service providing. However, the quality control research about the wireless network is insufficient because the existing research performs the quality control between the termination about the wired network continually. This paper presented the mobile service quality measurement reference considering the radio environment,that is the method for satisfying the quality guarantee of the wireless data network user offered the u-Healthcare service as the research about this and user needs. For this purpose, wireless data quality measurement indicator and standard was selected. The quality measure evaluation plan was presented according to the service. And each service presented the quality index especially.

Development of Automated Tools for Data Quality Diagnostics (데이터 품질진단을 위한 자동화도구 개발)

  • Ko, Jae-Hwan;Kim, Dong-Soo;Han, Ki-Joon
    • Journal of Information Technology Services
    • /
    • v.11 no.4
    • /
    • pp.153-170
    • /
    • 2012
  • When companies or institutes manage data, in order to utilize it as useful resources for decision-making, it is essential to offer precise and reliable data. While most small and medium-sized enterprises and public institutes have been investing a great amount of money in management and maintenance of their data systems, the investment in data management has been inadequate. When public institutions establish their data systems, inspection has been constantly carried out on the data systems in order to improve safety and effectiveness. However, their capabilities in improving the quality of data have been insufficient. This study develops an automatic tool to diagnose the quality of data in a way to diagnose the data quality condition of the inspected institute quantitatively at the stage of design and closure by inspecting the data system and proves its practicality by applying the automatic tool to inspection. As a means to diagnose the quality, this study categorizes, in the aspect of quality characteristics, the items that may be improved through diagnosis at the stage of design, the early stage of establishing the data system and the measurement items by the quality index regarding measurable data values at the stage of establishment and operation. The study presents a way of quantitative measurement regarding the data structures and data values by concretizing the measurement items by quality index in a function of the automatic tool program. Also, the practicality of the tool is proved by applying the tool in the inspection field. As a result, the areas which the institute should improve are reported objectively through a complete enumeration survey on the diagnosed items and the indicators for quality improvement are presented quantitatively by presenting the quality condition quantitatively.

Development of Gas Chromatography/Mass Spectrometry for the Determination of Essential Fatty Acids in Food Supplemental Oil Products

  • Ahn, Seonghee;Yim, Yoon-Hyung;Kim, Byungjoo
    • Mass Spectrometry Letters
    • /
    • v.4 no.4
    • /
    • pp.75-78
    • /
    • 2013
  • A gas chromatography/mass spectrometric (GC/MS) method was developed as a candidate reference method for the accurate determination of essential fatty acids (linoleic acid, ${\alpha}$- and ${\gamma}$-linolenic acids) in food supplemental oil products. Samples were spiked with three internal standards (stearic acid-$d_{35}$, $^{13}C_{18}$-linoleic acid, and $^{13}C_{18}$-${\alpha}$-linolenic acid). Samples were then subject to saponification, derivatization for methylation, and extraction by organic solvent. For GC/MS measurement, an Agilent HP-88 column, designed for the separation of fatty acid methyl esters, was selected after comparing with other columns as it provided better separation for target analytes. Target analytes and internal standards were detected by selected ion monitoring of molecular ions of their methyl ester forms. The GC/MS method was applied for the measurement of three botanical oils in NIST SRM 3274 (borage oil, evening primrose oil, and flax oil), and measurement results agreed with the certified values. Measurement results for target analytes which have corresponding isotope-labeled analogues as internal standard were calculated based on isotope dilution mass spectrometry (IDMS) approach, and compared with results calculated by using the other two internal standards. Results from the IDMS approach and the typical internal standard approach were in good agreement within their measurement uncertainties. It proves that the developed GC/MS method can provide similar metrological quality with IDMS methods for the measurement of fatty acids in natural oil samples if a proper fatty acid is used as an internal standard.

Fabrication and Evaluation of Digital Signal Processor for Multi-Lane Energy Measurement System (개별 전로 전력 계측을 위한 디지털 신호처리 프로세서 기반 전력 관제 시스템의 제작 및 평가)

  • Kim, Geun-Jun;Kang, Bongsoon
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.619-623
    • /
    • 2018
  • Due to the development of society, the demand for electric power has increased and the quality control of electric power has become an important issue. In order to efficiently perform such power management, we propose a DSP based power measurement system for multi-wire power measurement. Since the conventional power measurement system can measure only the power of one line, a power quality measurement device is required for each line in order to measure the power quality of the individual line. Respectively. The system proposed in this paper proposes a system capable of real-time measurement of power quality at up to 12 points using digital signal processing algorithm, and the prototype based on this system was evaluated through the official test report of Korea Electrotechnology Research Institute. As a result of the performance test, it was evaluated that the error range is excellent at ${\pm}0.3%$.

The application of a nondestructive method to measure the acidity of Korean papers (한지의 산성도 측정을 위한 비파괴적 방법의 적용)

  • Lee, Hye-Yun;Chung, Yong-Jae;Lee, Kyu-Sik;Han, Sung-Hee
    • 보존과학연구
    • /
    • s.20
    • /
    • pp.21-47
    • /
    • 1999
  • According to damage of papers by the chemical cause, papers become to acidify. Among the 3 kinds of method measuring the acidity of paper, one was nondestructive method measuring the surface of the paper by flat type electrode and the others were destructive methods measuring directly by cold water extract method and hot water extract method. In case of the cellulolytic cultural properties, the latter methods were not applied because those methods must bedissociated papers. To measure the paper acidity nondestructively, we investigated the correlation of the nondestructive method and the destructive methods. The conclusions are as follows. 1) In the relationship of the cold water extract method and the hot water extract method, It was indicated that the pH measured by the hot water extract method was high quality printing paper 0.08, rough printing paper 0.13, and Korean paper 0.29 higher than that by the cold water extract method.2) In the relationship of the cold water extract method and the surface measurement method, It showed that the pH value measured by the cold water extract method was high quality printing paper 1.86, rough printing paper 0.80,and Korean paper 0.58 higher than value that by the surface measurement.3) In the relationship of the hot water extract method and the surface measurement method, It showed that the pH value measured by the hot ABSTRACT water extract method was high quality printing paper 1.78, rough printing paper 0.66, and Korean paper 0.29 higher than that by the surface measurement. From the above-mentioned results, the pH value measured by the surface measurement was need to high about 1.78∼1.86 in high quality printing paper, 0.66-0.80 in rough printing paper, and 0.29∼0.58 in Korean paper and the surface measurement with flat type electrode was very available to measure the acidity of Korean papers actually.

  • PDF

On-site conservation of a gilt bronze crown (발굴현장 수습 유물 보존처리)

  • Yu, Jae-Eun
    • 보존과학연구
    • /
    • s.20
    • /
    • pp.49-64
    • /
    • 1999
  • According to damage of papers by the chemical cause, papers become to acidify. Among the 3 kinds of method measuring the acidity of paper, one was nondestructive method measuring the surface of the paper by flat type electrode and the others were destructive methods measuring directly by cold water extract method and hot water extract method. In case of the cellulolytic cultural properties, the latter methods were not applied because those methods must bedissociated papers. To measure the paper acidity nondestructively, we investigated the correlation of the nondestructive method and the destructive methods. The conclusions are as follows. 1) In the relationship of the cold water extract method and the hot water extract method, It was indicated that the pH measured by the hot water extract method was high quality printing paper 0.08, rough printing paper 0.13, and Korean paper 0.29 higher than that by the cold water extract method.2) In the relationship of the cold water extract method and the surface measurement method, It showed that the pH value measured by the cold water extract method was high quality printing paper 1.86, rough printing paper 0.80,and Korean paper 0.58 higher than value that by the surface measurement.3) In the relationship of the hot water extract method and the surface measurement method, It showed that the pH value measured by the hot ABSTRACT water extract method was high quality printing paper 1.78, rough printing paper 0.66, and Korean paper 0.29 higher than that by the surface measurement. From the above-mentioned results, the pH value measured by the surface measurement was need to high about 1.78∼1.86 in high quality printing paper, 0.66-0.80 in rough printing paper, and 0.29∼0.58 in Korean paper and the surface measurement with flat type electrode was very available to measure the acidity of Korean papers actually.

  • PDF

A Study of Security QoS(Quality of Service) Measurement Methodology for Network Security Efficiency (네트워크 보안 효율성 제고를 위한 보안 QoS(Quality of Service) 측정방법론 연구)

  • Noh, Si-Choon
    • Convergence Security Journal
    • /
    • v.11 no.1
    • /
    • pp.39-48
    • /
    • 2011
  • QoS(Quality of Service) is defined "The collective effect of service performance which determines the degree of satisfaction of a user of the service" by ITU-T Rec. E.800. The final goal of information system is to secure the performance efficiency within the required time. The security QoS framework is the modeling of the QoS measurement metrics, the measurement time schedule, instrument, method of measurement and the series of methodology about analysis of the result of measurement. This paper relates to implementing issue and performance measuring about blended mechanism between networking technology and security technology. We got more effectiveness in overall network security, when applying and composing amalgamated security mechanism between network technology and security technology. In this paper, we suggest techniques being used on infrastructure system and also offers a security QoS methodology as a model of more effective way. Methodology proposed in this research has proven that it is possible to measure response time through the scheduled method.

A Study on Searching Stabled EMI Shielding Effectiveness Measurement Point for Military Communication Shelter Using Support Vector Machine and Process Capability Analysis (서포트 벡터 머신과 공정능력분석을 이용한 군 통신 쉘터의 EMI 차폐효과 안정 포인트 탐색 연구)

  • Ku, Ki-Beom;Kwon, Jae-Wook;Jin, Hong-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.321-328
    • /
    • 2019
  • A military shelter for communication and information is necessary to optimize the integrated combat ability of weapon systems in the network centric warfare. Therefore, the military shelter is required for EMI shielding performance. This study examines the stable measurement points for EMI shielding effectiveness of a military shelter for communication and information. The measurement points were found by analyzing the EMI shielding effectiveness measurement data with data mining technique and process capability analysis. First, a support vector machine was used to separate the measurement point that has stable EMI shielding effectiveness according to set condition. Second, this process was conducted with process capability analysis. Finally, the results of data mining technique were compared with those of process capability analysis. As a result, 24 measurement points with stable EMI shielding effectiveness were found.

Effect Analysis of Measurement-related Investment by the PIMS model With Reference to Korean Industrial Firms (PIMS 모형(模型)의 응용(應用)에 의한 측정투자효과분석(測定投資效果分析) 우리나라 주요기업을 중심으로)

  • Kim, Dong-Jin;An, Ung-Hwan
    • Journal of Korean Society for Quality Management
    • /
    • v.18 no.2
    • /
    • pp.117-126
    • /
    • 1990
  • The Purpose of this study is to grasp the general effects of measurement-related investment by industrial firms. We presupposed the hypothesis that the measurement-related investment affects the decrease of product inferiority rates and analyzed the investigation results by means of PIMS(Profit Improvement of Market Strategy) model. As the results, we found out that the firms with positive measurement-related investment showed for less inferiority rates of products considerably. This study put an emphasis on the verification results showing that the considerable increase of measurement-related investment decreases the product inferiority rate by the statistical methods.

  • PDF

A Study on the Development of the measurement system of the Power steering unit for Automobile (자동차용 Poewer steering unit 의 자동측정시스템 개발에 관한 연구)

  • 기창두;김상묵
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.925-928
    • /
    • 1995
  • Recently, the system of the industry demands quick and accurate measurement for the mass production and high quality. Also, we need to improve the accuracy to decrease the failure rate in automatic assembly processing and improve the confidence, durability and the compatibility of parts. To answer this tendency and requirement, we have developed many accrate measuring instruments and methods. In this paper, we develop the whidows program using the DSP board(TMS320C25) which is used the data acquisition and the Visual C $^{++}$ , a windows programming language. We perform the measurement, analysis and output process in GUI(Graphic User Interface)environment. By using system, we will save the time required for the hand-worked measurement and avoid the useless iterative measurement. Furthermore, we expect to improve the productivity through automotive quality control in manufacturing process.s.

  • PDF