• Title/Summary/Keyword: Measurement Of Distance And Velocity

Search Result 161, Processing Time 0.03 seconds

A Study on Road Traffic Noise Environment Standard Establishment using Measurement Values of $L_{eq}$ ($L_{eq}$의 실측값을 이용한 도로교통소음 환경기준 설정에 관한 연구)

  • Kim, Byong-Sam;Choi, Hong-Chul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.277-282
    • /
    • 2006
  • Road traffic noise is not produced by any one factor rather occurs as a composition of various factors. Its occurrence is made by running engine noise, tire frictional, and exhaust noise etc. The quality of the noise depends on the size of the vehicles, rotation and engine speed, vehicle load, package state of the road and incline etc. The occurrence of noise level of heavy trucks appears louder than smaller vehicles and the noise levels produced differs according to speed and load etc between similar size vehicles. Other factors such as traffic density, average speed, mixing rate of heavy vehicles, and the distance between vehicles also generate road traffic noise. In this paper we examine 2, 4, and 6-lane roads in Jeonju. Consequently, this study examined the means used to measure road traffic noise. It was found that when there is a large traffic density and the average velocity is below 70 km/hr, the noise level could receive a relative proper value by the current measuring means. But in the case of night-time, it was found that the current measuring method is inapposite.

  • PDF

Depth estimation of an underwater target using DIFAR sonobuoy (다이파 소노부이를 활용한 수중표적 심도 추정)

  • Lee, Young gu
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.3
    • /
    • pp.302-307
    • /
    • 2019
  • In modern Anti-Submarine Warfare, there are various ways to locate a submarine in a two-dimensional space. For more effective tracking and attack against a submarine the depth of the target is a critical factor. However, it has been difficult to find out the depth of a submarine until now. In this paper a possible solution to the depth estimation of submarines is proposed utilizing DIFAR (Directional Frequency Analysis and Recording) sonobuoy information such as contact bearings at or prior to CPA (Closest Point of Approach) and the target's Doppler signals. The relative depth of the target is determined by applying the Pythagorean theorem to the slant range and horizontal range between the target and the hydrophone of a DIFAR sonobuoy. The slant range is calculated using the Doppler shift and the target's velocity. the horizontal range can be obtained by applying a simple trigonometric function for two consecutive contact bearings and the travel distance of the target. The simulation results show that the algorithm is subject to an elevation angle, which is determined by the relative depth and horizontal distance between the sonobuoy and target, and that a precise measurement of the Doppler shift is crucial.

An Experimental Study on the Turbulent Flow of a 45$^{\circ}C$ Free Cross Jet (450自由衝突 噴射 의 亂流流動 에 관한 實驗的 硏究)

  • 노병준;김장권
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.8 no.5
    • /
    • pp.442-449
    • /
    • 1984
  • Turbulent jet flow has been studied in many ways; a plane jet, a rectangular jet, an annular jet, a round jet, a wall jet, a parallel jet, a valve jet, a cross jet, a slit jet and etc. In this report, a 45.deg. cross jet flow was tried by using two same dimensioned nozzels(dia..phi.20)which were set up at the exit of the subsonic wind tunnel. Each jet flows to the direction of 22.5.deg. to the axis of downstream of the mixed flow. The centerline of each jet meets at the distance of 217.3mm and their mixing flow could be imagined to develop beyond that distance, so the measurement was effectuated at X/X$_{0}$=1.2-1.5. The section of the mixed flow a elliptic circle which is formed by the 22.5.deg. inclined flows to the X direction. This experimental study aimed at the investigation of the turbulent mixing process of two jets; the mean velocities, the turbulent shear stresses, the correlation coefficients, and the momentum were respectively measured. The mean velocity distribution profiles of the down-stream component measured in the Y direction coincide well with the empirical equation of Gortler and those measured in the Z direction agree with the equation of H. Schlichting. Other mean velocities V over bar and W over bar components were randomly distributed. The higher values with same order of the intensity of turbulence were largely distributed at the central part of the flow. The momentum was decreased up to 70% by the shock losses and the development of intense turbulences, but it kept its value constantly beyond X/d=14. Two-channel hot-wire anemometer systems (model 1050 series), X-type hot-wire made of tungsten (dia. .phi.e.mu.m, long 3mm, model 0252 T5), a computer(model HP 9845B0, and a plotter (model HP 9872C) were used for the experiments and the analyses.s.

Influence of Diverse Atmospheric Conditions on Optical Properties of a Pulse Laser in a Time-of-Flight Laser Range Finder

  • Shim, Young Bo;Kwon, Oh-Jang;Choi, Hyun-Yong;Han, Young-Geun
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.1
    • /
    • pp.1-6
    • /
    • 2015
  • We investigate the propagation characteristics of a pulse laser in a time-of-flight laser range finder (TOF-LRF) system with variations in atmospheric conditions, such as temperature, pressure, relative humidity, and the concentration of $CO_2$. The measurement error of distance related with the group velocity change in the TOF-LRF system is analyzed by considering the refractive index of the standard atmosphere with variations in atmospheric conditions. The dependence of the pulse width broadening induced by chromatic dispersion of the standard atmosphere on the operating wavelength and the initial pulse width of the light sources is discussed. The transmission of air with variations in the relative humidity or the concentration of $CO_2$ is analyzed by using different values of absorption coefficients depending on the operation wavelength of the light source in the TOF-LRF system.

In-situ measurement of railway-traffic induced vibrations nearby the liquid-storage tank

  • Goktepe, Fatih;Kuyuk, Huseyin S.;Celebi, Erkan
    • Earthquakes and Structures
    • /
    • v.12 no.5
    • /
    • pp.583-589
    • /
    • 2017
  • In this study, result of a field investigation of railway traffic-induced vibrations is provided to examine acceptability levels of ground vibration and to evaluate the serviceability of a liquid-storage tank. Free field attenuation of the amplitudes as a function of distance is derived by six accelerometers and compared with a well-known half-space Bornitz's analytical solution which considers the loss of the amplitude of waves due to geometrical damping and material damping of Rayleigh. Bornitz's solution tends to overlap vertical free field vibration compared with in-situ measured records. The vibrations of the liquid-storage tank were compared with the USA, Federal Transportation Railroad Administration (FTA) criteria for acceptable ground-borne vibrations and with the criteria in DIN 4150-3 German standard. Comparing the thresholds stated in DIN 4150-3, absolute peak particle velocities are within the safe limits, however according to FTA velocity level at the top of the water tank exceeds the allowable limits. Furthermore, it is intended to indicate experimentally the effect of the kinematic interaction caused by the foundation of the structure on the free-field vibrations.

Consequence Analysis of Hydrogen Blended Natural Gas(HCNG) using 3D CFD Simulation (CFD를 활용한 수소-천연가스 혼합연료에 대한 피해영향 분석)

  • Kang, Seung-Kyu;Bang, Hyo-Jung;Jo, Young-Do
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.5
    • /
    • pp.15-21
    • /
    • 2013
  • This study evaluated comparison of the risk according to the type of fuel by three-dimensional simulation tool(FLACS). The consequence analysis of fire explosion and jet-fire was carried out in the layout of a typical high-pressure gas filling stations using CNG, hydrogen and 30%HCNG. Under the same conditions, hydrogen had a 30kPa maximum overpressure, CNG had a 0.4kPa and HCNG had a 3.5kPa. HCNG overpressure was 7.75 times higher than the CNG measurement, but HCNG overpressure was only 11.7% compared to hydrogen. In case of flame propagation, hydrogen had a very fast propagation characteristics. On the other hand, CNG and HCNG flame propagation velocity and distance tended to be relatively safe in comparison to hydrogen. The estimated flame boundary distance by jet-fire of hydrogen was a 5.5m, CNG was a 3.4m and HCNG was a 3.9m.

Prediction of Curvature Effects on the Electromagnetic Flowmeter Characteristics with Numerical Simulation (Laminar flow) (곡관의 곡률에 따른 전자기유량계 설치효과의 수치모사에 의한 특성 예측(충류))

  • Lim, Ki Won;Choi, Sang Kyu;Chung, Myung Kyoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.11
    • /
    • pp.1453-1463
    • /
    • 1999
  • An electromagnetic flowmeter, based on a magnetic induction principle; provides an obstructionless flowmeter that essentially averages the velocity distribution over the pipe cross-sectional area. To predict the installation effects, the flowmeter installed near $90^{\circ}$ elbow is simulated by using a commercial code FLUENT(ver. 4.48) for the laminar flow field and a code developed through this study for magnetic field. The installation effects of the flowmeter are estimated by varying a number of the dependent parameters such as the radius of the elbow(Rc=1D, 1.5D, 2D, 3D), the location, Reynolds number and the direction of electrodes plane(${\varphi}$). It was found that all these factors affect the performance of the electromagnetic flowmeter significantly. The longer installation distance from the elbow is not always optimal to minimize the error, and also there exists an optimal location to install the EMF for a minimum error. Especially the flow signal with the electrodes plane direction of ${\varphi}=45^{\circ}$ is shown to yield smallest measurement error regardless of the Reynolds number and the curvature of elbow.

Study on the Jet Impingement Heat Transfer Characteristics at Protruding heated Blocks (돌출 발열블록표면에서의 충돌분류 열전달 특성에 관한 연구)

  • Jeong, In-Gi;Park, Si-U;Park, Su-Cheol
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.12
    • /
    • pp.1670-1677
    • /
    • 2000
  • An experimental investigation on heat transfer characteristics of two-dimensional heated blocks using a confined impinging slot jet has been performed. The effect of jet Reynolds number(Re=3900, 5800, 9700), streamwise block spacing(p/w=0.5, 1, 1.5) and dimensionless nozzle to block distance(H/B=1, 2, 4, 6) have been examined with five isothermally heated blocks. With the measurement of jet mean velocity and turbulence intensity distributions at nozzle exit, initially turbulent regimes, are classified. To clarify local heat transfer characteristics, naphthalene sublimation technique as used. The maximum Nusselt number at the stagnation point for the jet Reynolds number is occurred at H/B=4. Besides, the local and a average heat transfer of heated blocks increase with decreasing streamwise block spacing and increasing jet Reynolds number.

LSAW Velocity Measurement by Using a PVDF Line-Focus Ultrasonic Transducer (PVDF 직선집속 초음파 트랜스듀서에 의한 누설탄성표면파 속도 측정)

  • 윤혁준;하강열;김무준;윤종락
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.1
    • /
    • pp.62-67
    • /
    • 2001
  • Velocities of leaky surface acoustic waves (LSAW/sub s/) were measured by using a line-focus polyvinylidene fluoride (PVDF) transducer and compared with theoretically calculated ones. Isotropic materials of Cu, Al, fused quartz, and anisotropic one of Z-cut α-quartz crystal were used as specimens. The velocities were obtained by the separation time between wave components reflected directly from the surface of specimen and LSAW components according to the defocusing distance. The measured velocities well agree with the theoretical results within 1% error, and it was shown that the leaky pseudo-surface acoustic wave (LPSAW) as well as the LSAW propagates with the typical 6-fold anisotropy on the (0,0,1) surface of α-quartz.

  • PDF

Measurements on the Propagation Path Loss Exponent at Maritime VHF Channel Using Single Carrier Signal (단일 반송파를 이용한 해상 VHF 채널의 전파 경로 감쇠 지수 측정)

  • Kim, Seung-Geun;Kim, Sea-Moon;Yun, Changho;Lim, Yong-Kon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.7
    • /
    • pp.1450-1456
    • /
    • 2015
  • The received signal strengths according to the propagation distance between a transmitting shore station with a 53 m antenna hight and a receiving ship station with about 6m antenna hight from 700 m upto about 20 km are measured at ship's moving velocity of $5{\pm}1m/s$ using a single carrier signal at 150.0625MHz. In this paper, the path loss exponents at the propagation distance from 700 m to 20km are estimated via minimum-mean-square-error method using the measurements of the received signal strength, and the mean of the estimated path loss exponent become 3.79. The estimated propagation path loss exponents is similar to that calculated based on the field-strength values from 2 km to 20 km in Annex 2 of ITU-R P.1546-4, which is measuring results at maritime VHF at 100 MHz carrier frequency. Therefore, the estimated propagation path loss exponent shall be used as the expected path loss exponents for summer in costal area of South Sea of Korea.