• Title/Summary/Keyword: Measurement Indicator

Search Result 495, Processing Time 0.023 seconds

A Modified Residual-based Extended Kalman Filter to Improve the Performance of WiFi RSSI-based Indoor Positioning (와이파이 수신신호세기를 사용하는 실내위치추정의 성능 향상을 위한 수정된 잔차 기반 확장 칼만 필터)

  • Cho, Seong Yun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.7
    • /
    • pp.684-690
    • /
    • 2015
  • This paper presents a modified residual-based EKF (Extended Kalman Filter) for performance improvement of indoor positioning using WiFi RSSI (Received Signal Strength Indicator) measurement. Radio signal strength in indoor environments may have irregular attenuation characteristics due to obstacles such as walls, furniture, etc. Therefore, the performance of the RSSI-based positioning with the conventional trilateration method or Kalman filter is insufficient to provide location-based accurate information services. In order to enhance the performance of indoor positioning, in this paper, error analysis of the distance calculated by using the WiFi RSSI measurement is performed based on the radio propagation model. Then, an IARM (Irregularly Attenuated RSSI Measurement) error is defined. Also, it shows that the IARM error is included in the residual of the positioning filter. The IARM error is always positive. So, it is presented that the IARM error can be estimated by taking the absolute value of the residual. Consequently, accurate positioning can be achieved based on the IEM (IARM Error Mitigated) EKF with the residual modified by using the estimated IARM error. The performance of the presented IEM EKF is verified experimentally.

Design of Performance Measurement Indicators for the Small and Medium Sized Manufacturing Company (중소(中小)제조업의 성과평가를 위한 성과측정지표 설계 방법)

  • Hong, Hyun-Gi;Oh, Sang-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.4
    • /
    • pp.887-894
    • /
    • 2009
  • Recently many companies has implied the measurement system to measure the organizational and personal performance. For that purpose the measurement system based on Balanced Scorecard(BSC) is broadly implemented. For the successful and effective measurement of performance measurement the design of measurement methodology and indicators should be carried out by experts in this field, and "the objectivity" should be kept in the whole process. But due to the financial difficulties many of the companies have relied on the standard (performance measurement) software, which is avaliable in the market. In this paper the performance measurement. Indicators has been presented for the small and medium sized manufacturing company. As the result of this research the presented performance measurement indicators for administration, operation and R&D part are statistically verified as it is effective.

대사열의 발생을 이용한 활성슬러지의 활성 측정

  • Park, Sun-Eung;Heo, Won
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.04a
    • /
    • pp.398-401
    • /
    • 2000
  • A device to measure the temperature difference between the supernatant and the sediment blanket in the course of SV30 measurement in processing of activated sludge process. The temperature elevation in the sludge sediment represent the metabolic heat production by the microorganisms and can be an indicator for the capability of waste treatment. The utilities of the device for the analysis of activated sludge process were demonstrated in this report.

  • PDF

A Study on the Measurement and Evaluation of LSC Roundness by Index Head (INDEX HEAD를 이용한 절대 진원도의 측정 평가에 관한 연구)

  • Lee, Dong-Ju
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.8 no.3
    • /
    • pp.18-26
    • /
    • 1991
  • A study on the measuring and evaluation of LSC(Least Square Center) roundness was carried out. The experimental set-up was made by index head and indicator, and the measuring data were compensated by a developed computer program. The results obtained are as follows : 1) An index head can conveniently be used to measure LSC roundness. 2) A program for calculating LSC roundness is developed. 3) Without a high quality roundnes measuring apparatus, LSC roundness can be measured and calculated by using index head and the developed program in machine shop as well as in a measuring room

  • PDF

Recovery Voltage Measurements of Oil-immersed Transformer

  • Li, Ming-Hua;Dong, Ming;Qu, Yan-Ming;Yan, Zhang
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.5
    • /
    • pp.230-234
    • /
    • 2006
  • One of the methods currently being investigated as a possible non-intrusive diagnostic tool for condition monitoring of power transformer and cable is the recovery voltage measurement, which will be improving the ability to detect the content of water concentration and the ageing process in the insulation system and may thus be an indicator of insulation quality and its ageing status. The polarization phenomenon was studied using RVM with oil-paper samples. In order to interpret its mechanism, the Extended Debye model was introduced. With different circuit parameters, various simulation results were gotten. Furthermore, with the test samples of different ageing condition, measurements are accomplished in the lab. On the basis of this experiment as well as theoretical analysis, correlations between polarizations and ageing were analyzed.

A Study on Establishing Performance Measurement and Evaluation System of ATM (ATM 성능측정 및 평가체계 구축 연구)

  • Seo, Youngsung;Park, Bomi;Kim, Jun-hyuk
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.26 no.1
    • /
    • pp.37-43
    • /
    • 2018
  • There has been the migration to a performance-based approach in many areas which include transition planning at global, regional and local levels, performance-based navigation and safety management. Achieving continuous success of Air Traffic Management (ATM) systems would require a performance-based approach to raise productivity and efficiency of it through performance measurements and reviews. This paper considers establishment planning of performance measurement and evaluation system for ATM. Related to key performance areas proposed by International Civil Aviation Organization, performance indicators and metrics which could be used to measure and evaluate ATM performance are presented. Also, organizational system and operational planning for efficient operation of ATM are presented.

1/f-LIKE FREQUENCY FLUCTUATION IN FRONTAL ALPHA WAVE AS AN INDICATOR OF EMOTION

  • Yoshida, Tomoyuki
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2000.04a
    • /
    • pp.99-103
    • /
    • 2000
  • There are two approaches in the study of emotion in the physiological psychology. The first is to clarify the brain mechanism of emotion, and the second is to evaluate objectively emotions using physiological responses along with our feeling experience. The method presented here belongs to the second one. Our method is based on the "level-crossing point detection" method. which involves the analysis of frequency fluctuations of EEG and is characterized by estimation of emotionality using coefficients of slopes in the log-power spectra of frequency fluctuation in alpha waves on both the left and right frontal lobe. In this paper we introduce a new theory of estimation on an individual's emotional state by using our non-invasive and easy measurement apparatus.

  • PDF

Manufacturing Process of Translucent Microemulsion and Its Stability (Translucent Microemulsion의 제조 공정과 안정성)

  • Bae, Duck-Hwan;Shin, Jae-Sup
    • Journal of the Korean Applied Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.167-173
    • /
    • 2000
  • The process variables for the manufacture of translucent microemulsion prepared with 2-octyl dodecanol, 12-hydroxy stearic acid cholesteryl , POE(40)HCO and 1,3-butandiol were examined initially (primary emulsion) and following aging for three months. The techniques empolyed in this study were particle size, turbidity, interfacial tension and microfluidizer. Particle size analysis and turbidity measurement to evaluate the emulsion stability were used. It was concluded that the process of the emulsification was an important indicator of the stability of the translucent microemulsion. From the particle size and and turbidity measurement of translucent microemulsion, adding the surfactant to the oil phase before the emulsification was found to be the most important factor for the stability of emulsions. We found that interfacial tension of the adding the surfactant to the oil phase is lower than that of the adding the surfactant to aqueous phase. In spite of hydrophilic surfactant, adding the surfactant to aqueous phase produced inferior emulsion to that to oil phase.

Study on the Observability of a Calibration System for a Parallel Tilting Table with Measuerment Operator (측정연산자에 의한 병렬기구 틸팅 테이블의 관측성에 관한 연구)

  • Park Kun Woo;Lee Min Ki;Kim Tae Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.6 s.237
    • /
    • pp.795-803
    • /
    • 2005
  • This paper studies the observability of calibration system with a measurement operator. The calibration system needs a simple digital indicator to measure the mobile table movements with respect to the MC coordinate. However, it yields the concern about the poor parameter observability due to measuring only a part of the movements. We uses the QR-decomposition to find the optimal calibration configurations maximizing the linear independence of rows of an observation matrix. The number of identifiable parameter is examined by the rank of the observation matrix, which represents the parameter observability. The method is applied to a 6-axis MC with parallel tilting table and the calibration results are presented. These results verify that all necessary kinematic parameters are observable and the calibration system has robustness to the noise using optimal calibration configurations.

An Evaluation Framework for Defense Informatization Policy

  • Jung, Hosang;Lee, Sangho
    • Journal of Multimedia Information System
    • /
    • v.7 no.1
    • /
    • pp.73-86
    • /
    • 2020
  • The well-known sentence, "You can't manage what you don't measure" suggests the importance of measurement. The Ministry of National Defense (MND) in Korea is measuring the effort of informatization for various dimensions such as validity, adequacy, and effectiveness using the MND evaluation system to obtain positive and significant effects from informatization. MND views the defense informatization domain as divided into the defense informatization policy, the defense informatization project, and the defense informatization level, which can measure the informatization capability of the MND and the armed forces or organizations. Furthermore, it feels there is some limitation, such as those related to ambiguity and reliability, present in the system. To overcome the limitations in the existing system to evaluate the defense informatization policy, this study proposes a revised evaluation framework for the policy of defense informatization, its indicators, and measurement methods.