• Title/Summary/Keyword: Measurement Indicator

Search Result 495, Processing Time 0.032 seconds

The Comparative Analysis of External Dose Reconstruction in EPID and Internal Dose Measurement Using Monte Carlo Simulation (몬테 카를로 전산모사를 통한 EPID의 외부적 선량 재구성과 내부 선량 계측과의 비교 및 분석)

  • Jung, Joo-Young;Yoon, Do-Kun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.253-258
    • /
    • 2013
  • The purpose of this study is to evaluate and analyze the relationship between the external radiation dose reconstruction which is transmitted from the patient who receives radiation treatment through electronic portal imaging device (EPID) and the internal dose derived from the Monte Carlo simulation. As a comparative analysis of the two cases, it is performed to provide a basic indicator for similar studies. The geometric information of the experiment and that of the radiation source were entered into Monte Carlo n-particle (MCNPX) which is the computer simulation tool and to derive the EPID images, a tally card in MCNPX was used for visualizing and the imaging of the dose information. We set to source to surface distance (SSD) 100 cm for internal measurement and EPID. And the water phantom was set to be 100 cm of the source to surface distance (SSD) for the internal measurement and EPID was set to 90 cm of SSD which is 10 cm below. The internal dose was collected from the water phantom by using mesh tally function in MCNPX, accumulated dose data was acquired by four-portal beam exposures. At the same time, after getting the dose which had been passed through water phantom, dose reconstruction was performed using back-projection method. In order to analyze about two cases, we compared the penetrated dose by calibration of itself with the absorbed one. We also evaluated the reconstructed dose using EPID and partially accumulated (overlapped) dose in water phantom by four-portal beam exposures. The sum dose data of two cases were calculated as each 3.4580 MeV/g (absorbed dose in water) and 3.4354 MeV/g (EPID reconstruction). The result of sum dose match from two cases shows good agreement with 0.6536% dose error.

Pelvic Measurement Indicators to Produce the Gonad Protection of Female Infants (유아기 여아의 생식선 차폐체 제작을 위한 골반 지표 계측)

  • Kwak, Jong-hyeok;Park, Chan-hyeok;Moon, deog-hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.2
    • /
    • pp.101-107
    • /
    • 2016
  • It was performed in this study to provide basic information on production of accurate gonadal shield by measuring pelvic indicators of TDP SD ISP IAD 1CDP and 2CDP. when pelvis ap and hip ap examination was taken, there is no exact position of the reference point of the shield and anatomically more difficult to shield gonad in the case of female infants than male. Results analyzed by height in 70~80 and 110~120 were approximately 30mm 13mm 19mm 20mm 2mm and 7mm difference in TDP SD ISP IAD 1CDP and 2CDP respectively. This value was statistically significant (P<0.05). Results analyzed by age of 2~3 and 6~7 were different on SD ISP IAD and 2CDP by 17mm 10mm 12mm 16mm respectively. it was also statistically significant. However 1CDP was not statistically significant(P>0.05). the difference was nearly about 1mm. Analysis of results by weight of less than 10 and more than 20 showed difference on TDP SD ISP IAD 1CDP and 2CDP by 28mm 14mm 11mm 20mm 3mm and 8mm. it was statistically significant (P<0.05). From the above results, female infants pelvic indicator measurement can be used as reference value for shielding production and especially IAD can present a reference point on the shielding position. Pelvis indicators of female infant has a close correlation. In addition, as it is showen in the statistical difference analysis to have an accurate ovarian shield, gonad shield would be produced and used by height, age and weight.

Study on Glomerular Filtration Rate comparison according to renal depth measurement of kidney donors (신 공여자에서 신장 깊이 측정에 따른 사구체여과율의 비교에 관한 고찰)

  • Lee, Han Wool;Park, Min Soo;Kang, Chun Goo;Cho, Seok Won;Kim, Joo Yeon;Kwon, O Jun;Lim, Han Sang;Kim, Jae Sam;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.48-56
    • /
    • 2014
  • Purpose $^{99m}Tc$-DTPA renal scintigraphy serves as a key indicator to measure a kidney donor's Glomerular Filtration Rate (GFR) and determine the possibility of kidney transplant. The Gates method utilized to measure GFR considers 3 variables of renal depth, injection dose, and net kidney counts. In this research, we seek to compare changes in kidney donors' GFR according to renal depth measurement methods of the 3 variables. Materials and Methods We investigated 32 kidney donors who had visited the hospital from October, 2013 to March, 2014 and received abdominal CT and $^{99m}Tc$-DTPA GFR examination. With the cross-section image of the CT and the lateral image from a gamma camera, we measured the renal depth and compared with renal depth calculation equations-Tonnesen, Taylor, and Itoh methods. Renal depth-specific GFR was calculated by using Xeleris Ver. 2.1220 of GE. Then the results were compared with MDRD (Modification of Diet Renal Disease) GFRs based on serum creatinine level. Results The renal depths measured based on the CT and gamma camera images showed high correlation. Tonessen equation gave the lowest GFR value while the value calculated by using the renal depth of CT image was the highest with a 16.62% gap. MDRD GFR showed no statistically significant difference among values calculated through Taylor, Itoh, CT and gamma camera renal depth application (P>0.05), but exhibited a statistically significant change in the value based on Tonnesen equation (P<0.05). Conclusion This research has found that, in GFR evaluation in kidney donors by utilizing $^{99m}Tc$-DTPA, Tonnesen equation-based Gates method underestimated the value than the MDRD GFR. Therefore, if a MDRD GFR value shows a huge difference from the actual examination value, using an image-based renal depth measurement, instead of Tonnesen equation applied to Gates method, is expected to give an accurate GFR value to kidney donors.

  • PDF

Studies of the Physiological Impediments on the Silkworm(Bombyx mori L.) due to Anthracite Gas -Regarding with Carbon Monoxide and Sulphur Dioxide- (무연탄가스에 의한 가잠의 발육과 생리작용에 미치는 영향에 관한 연구-산화탄소와 무수아황산가스를 중심으로-)

  • 윤종관
    • Journal of Sericultural and Entomological Science
    • /
    • v.10
    • /
    • pp.1-25
    • /
    • 1969
  • Since widely use of anthracite for the radiating purpose in a rearing room in Korea, the weakness of silkworm, poor uniformity of the worm growth, the increase of missing worm ratio, unusual cocoon assorting ratio, and the decrease of cocoon layer ratio have been realized by the author, therefore, he has started out to search the mechanism of these evil influences regarding with various gas densities and terms of the gas treatment which will be supposed to be a warning for temperature control during the silkworm reading work. Among the anthracite gas components, CO or SO$_2$ influence and their complexed harm effect were investigated through the use of anthracite gas, CO and SO$_2$ gas. Meantime, each treatment was applied, separately, during the worm egg stage, young instar, adult instar and whole instar, because the harm intensity for any improperable rearing condition is flexible by the growing stages. Meantime, the gas density and term variation were applied for the above each treatment such as in case of anthracite and CO gas, the following treat methods were used. 1) 0.06% for 30 mins. 2) 0.06% for 1 hour. 3) 0.1% for 1 hour. 4) 0.15% for 1 hour. on the other hand, SO$_2$ gas was used as 1) 120ppm for 30 mins. 2) 200ppm for 30 mins. 3) 400ppm for 30 mins. The measurement of gas density was proceeded by using CO tester (Carbon Monoxide Indicator) and SO$_2$ tester (Indicator Sampler Cgf) which could keep any specific density before each treatment.

  • PDF

Changes of Serum Troponin-T Concentrations in Patients with Open Heart Surgery (개심술환자에 있어 혈청 Troponin-T 농도의 변화에 관한 연구)

  • 박동욱;최석철;김윤규;박종원;조관현
    • Journal of Chest Surgery
    • /
    • v.31 no.2
    • /
    • pp.125-133
    • /
    • 1998
  • This study was designed to identify the efficiency of serum troponin-T(s-TnT) level as a diagnostic indicator for the perioperative myocardial damage with open heart surgery(OHS) and to compare with the conventional myocardial enzyme tests such as isoenzyme fraction of creatine kinase(% CK-MB) and isoenzyme ratio of lactate dehydrogenase(LDH1/LDH2 ratio). The study was performed on 30 adult patients who underwent OHS from Jan. 1996 to June 1996 at Inje University Pusan Paik Hospital, and they were divided into two groups accor- ding to aortic clamping time(ACT) duration : group I(ACT<60 minutes, n=15); group II (ACT>60 minutes, n=15). S-TnT, % CK-MB, and LDH1/LDH2 ratio were measured in serial blood samples from all subjected patients. The results were obtained as follows. 1. In both groups, s-TnT concentrations increased gradually during OHS and elevated significantly at CPB-10(p<0.001). The peak level was noticed at POD 1 in group I(1.10 $\pm$0.19 ng/ml), whereas, at CPB-off in group II(1.88$\pm$0.42 ng/ml). The elevated levels remained until POD 7 in both groups. 2. %CK-MB was risen significantly with the initiation of operations(p<0.001) and the peak levels were noticed at CPB-off in both groups(7.14$\pm$0.86% in group I, 10.69$\pm$1.27% in group II). Thereafter, these levels returned to normal values at POD 3. 3. There were no significant changes in the values of LDH1/LDH2 ratio during and after OHS compared with the control levels(p>0.05). 4. The serial changes of s-TnT were relatively well correlated with those of changes of % CK-MB(r=0.64, p<0.05). 5. The serial s-TnT levels were significantly higher in group II than group I from B-ACR to POD 1(p<0.05), suggesting that duration of aortic clamping time was a major factor concerned with perioperative myocardial injury. In conclusion, measurement of s-TnT is a very useful indicator in assessing the myocardial cell damage and therefore it is expected that serial checking and evaluation of the s-TnT is very available for identification of the perioperative myocardial damage and for postoperative cares in patients with OHS.

  • PDF

Development of Economic Analysis Indicators and Case Scenario Analysis for Decision-making support for Off-Site Construction Utilization of Apartment Houses (OSC 활용 의사결정 지원을 위한 경제성 분석 지표 개발 및 사례 시나리오 분석 - 공동주택 PC공법을 중심으로 -)

  • Yun, Won-Gun;Bae, Byung-Yun;Shin, Eun-Young;Kang, Tai-Kyung
    • Korean Journal of Construction Engineering and Management
    • /
    • v.24 no.6
    • /
    • pp.24-35
    • /
    • 2023
  • Recently, the Ministry of Land, Infrastructure and Transport presented the '6th Construction Technology Promotion Basic Plan' and 'Smart Construction Revitalization Plan (2022.7.20)'. Off-Site Construction (OSC), which involves construction and production of PC (Precast Concrete) and Modular, etc., has advantages in shortening the construction period, reducing costs, improving quality, reducing construction waste, and reducing safety accidents. However, the construction cost is high compared to the traditional RC construction method, which has hindered its utilization and spread. In this study, OSC utilization was improved. An economic analysis indicator and methodology that can support decision-making in the planning and design stages for multi-unit housing were proposed. The factors used in the economic analysis of OSC (based on the PC method) of apartment houses were reviewed. As for the indicators used in the cost and benefit section, 'Construction Period', 'Disaster Occurrence', 'Waste Generation', and 'Greenhouse gas Emission', which reflect the technical advantages of OSC, were derived. In addition, a scenario analysis was conducted based on actual apartment housing case data for the presented economic analysis indicators and benefit calculation standards. The level of benefit that offsets the difference between the existing RC construction method and the construction cost was reviewed. In future studies, it will be necessary to conduct additional case studies to apply the measurement criteria for detailed indicators and supplement the benefit indicators.

Spirometry and Bronchodilator Test

  • Sim, Yun Su;Lee, Ji-Hyun;Lee, Won-Yeon;Suh, Dong In;Oh, Yeon-Mok;Yoon, Jong-seo;Lee, Jin Hwa;Cho, Jae Hwa;Kwon, Cheol Seok;Chang, Jung Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.80 no.2
    • /
    • pp.105-112
    • /
    • 2017
  • Spirometry is a physiological test for assessing the functional aspect of the lungs using an objective indicator to measure the maximum amount of air that a patient can inhale and exhale. Acceptable spirometry testing needs to be conducted three times by an acceptable and reproducible method for determining forced vital capacity (FVC). Until the results of three tests meet the criteria of reproducibility, the test should be repeated up to eight times. Interpretation of spirometry should be clear, concise, and informative. Additionally, spirometry should guarantee optimal quality prior to the interpreting spirometry results. Our guideline adopts a fixed normal predictive value instead of the lower limit of normal as the reference value because fixed value is more convenient and also accepts FVC instead of vital capacity (VC) because measurement of VC using a spirometer is impossible. The bronchodilator test is a method for measuring the changes in lung capacity after inhaling a short-acting ${\beta}-agonist$ that dilates the airway. When an obstructive ventilatory defect is observed, this test helps to diagnose and evaluate asthma and chronic obstructive pulmonary disease by measuring reversibility with the use of an inhaled bronchodilator. A positive response to a bronchodilator is generally defined as an increase of ${\geq}12%$ and ${\geq}200mL$ as an absolute value compared with a baseline in either forced expiratory volume at 1 second or FVC.

Analysis of Galvanic Skin Response Signal for High-Arousal Negative Emotion Using Discrete Wavelet Transform (이산 웨이브렛 변환을 이용한 고각성 부정 감성의 GSR 신호 분석)

  • Lim, Hyun-Jun;Yoo, Sun-Kook;Jang, Won Seuk
    • Science of Emotion and Sensibility
    • /
    • v.20 no.3
    • /
    • pp.13-22
    • /
    • 2017
  • Emotion has a direct influence such as decision-making, perception, etc. and plays an important role in human life. For the convenient and accurate recognition of high-arousal negative emotion, the purpose of this paper is to design an algorithm for analysis using the bio-signal. In this study, after two emotional induction using the 'normal' / 'fear' emotion types of videos, we measured the Galvanic Skin Response (GSR) signal which is the simple of bio-signals. Then, by decomposing Tonic component and Phasic component in the measured GSR and decomposing Skin Conductance Very Slow Response (SCVSR) and Skin Conductance Slow Response (SCSR) in the Phasic component associated with emotional stimulation, extracting the major features of the components for an accurate analysis, we used a discrete wavelet transform with excellent time-frequency localization characteristics, not the method used previously. The extracted features are maximum value of Phasic component, amplitude of Phasic component, zero crossing rate of SCVSR and zero crossing rate of SCSR for distinguishing high-arousal negative emotion. As results, the case of high-arousal negative emotion exhibited higher value than the case of low-arousal normal emotion in all 4 of the features, and the more significant difference between the two emotion was found statistically than the previous analysis method. Accordingly, the results of this study indicate that the GSR may be a useful indicator for a high-arousal negative emotion measurement and contribute to the development of the emotional real-time rating system using the GSR.

Characterizing Fluorescence Properties of Dissolved Organic Matter for Water Quality Management of Rivers and Lakes (하천 및 호소 수질관리를 위한 용존 자연유기물질 형광특성 분석)

  • Hur, Jin;Shin, Jae-Ki;Park, Sung-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.9
    • /
    • pp.940-948
    • /
    • 2006
  • Fluorescence measurements of dissolved organic matter(DOM) have the superior advantages over other analysis tools for applying to water quality management. They are simple and fast and require minimal pretreatment of samples. Fluorescence index($F_{450}/F_{500}$), synchronous spectra, and fluorescence excitation-emission matrices(EEM) of various DOM samples were investigated to discriminate autochthonous/allochthonous composition, protein-like fluorescence, fulvic-like fluorescence, humic-like fluorescence, terestrial humic-like fluorescence by comparing among the real DOM samples of different origins with the help of literature. The samples used included standard purified DOM, lake, river and wastewater treatment effluent. The relative distribution of various DOM composition was derived from the ratios of each fluorescence region. The results were very consistent with those expected from the sample properties. Allochthonous and terrestrial humic-like fluorescence were more prominent in the samples with abundant soil-derived DOM components. In addition, the protein-like fluorescence property was more pronounced in the samples where strong algal or microbial activities were expected. It was also shown that the ratio of protein-like/terrestrial humic-like fluorescence obtained from synchronous spectrum and fluorescence EEM could be used as an indicator for the evaluation of wastewater treatment on the downstream water quality of rivers and for the prediction of the degree of algal/microbial activities in lakes. It is expected that the results of this study will provide the basic information to develop the future water quality management techniques using DOM fluorescence measurements.

Design and Fabrication of 24 GHz 3-Beam Scan Antennas for ACC Applications (자동 주행 차량을 위한 24 GHz 3-Beam Scan 안테나의 설계 및 제작)

  • 원영진;이영주;공영균;김영수
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.1
    • /
    • pp.81-88
    • /
    • 2003
  • For driver's convenience, the ACC(Adaptive Cruise Control) requires a system which determines the direction of vehicles and controls the vehicle to keep the distance among the automobiles constant. This paper describes the microstrip array antennas designed to operate at 24 GHz, and used as a direction indicator of moving vehicles. 8${\times}$2 transmit array antenna with wide beamwidth, 8${\times}$4 receive center array antenna, and two 8${\times}$8 receive array antennas with narrow beamwidth were designed and fabricated. Measurement results for the arrays showed that the azimuthal beamwidth is 50$^{\circ}$and the gain is 16.7 dBi for the transmit array antenna. For the receive array antenna, the center, the left, and the right array antenna have beamwidths of 20$^{\circ}$, 13$^{\circ}$, 13$^{\circ}$respectively, and have gains of more than 20 dBi. The left and right array antenna have the beam tilt angle of ${\pm}$18$^{\circ}$. The measured radiation patterns showed a good agreement with the simulated patterns, and the designed array antennas are suitable fur detecting 3 directions of the vehicle within the scan angle area.