• Title/Summary/Keyword: Measurement Indicator

Search Result 495, Processing Time 0.031 seconds

Distributions of Formaldehyde in Seoul in June, 2005 (2005년 6월의 서울시 대기의 포름알데히드 농도분포 특징)

  • Hwang Jung hoon;Lee Mee hye;Lee Gang woong;Han Jin seock
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.1
    • /
    • pp.63-71
    • /
    • 2006
  • An automated carbonyl measurement system was constructed. Atmospheric carbonyl compounds were extracted onto DNPH containing collection solution while flowing through a glass coil. Each carbonyl species was separated on a HPLC column and quantified by UV absorption detector. Using this system, carbonyl compounds were continuously measured at the campus of Korea University in Seoul, Korea during June, 2005. Sampling resolution was 30 minutes and the detection limit of HCHO was 0.19 ppbv. Also, $\O_{3}$, it's precursors, and meteorological parameters were measured. The maximum, minimum, average, and median concentrations of HCHO during the whole experiment was 35.8 ppbv, 1.4 ppbv, 11.7 ppbv, and 9.3 ppbv respectively. Formaldehyde showed a distinct diurnal variation with a broad maximum around 13 $\sim$ 15, which was 1 $\sim$ 3 hours ahead of an ozone maximum. During a couple of days, however, HCHO concentrations were kept high through the night or increased concomitantly with NOx in the morning. These results imply that HCHO was mainly produced from the photochemical oxidation of VOCs, but local emission sources couldn't be ruled out. The differences between daily maximum and minimum of $O_{3}$ and HCHO were calculated for 11 days of June, when typical diurnal variations were observed for the two species. A strong positive correlation was found between $\Delta O_{3}$ and $\Delta HCHO$ and the average mole ratio of $\Delta HCHO$ to $\Delta O_{3}$ was 2.6. It indicates that formaldehyde played a key role in $\Delta O_{3}$ production as an indicator species in Metropolitan Seoul during June, 2005.

Hybrid ABS based Inter-Cell Scheduling Algorithms for QoS Improvement of Heterogeneous Networks (이기종 네트워크의 QoS 향상을 위한 Hybrid ABS기반 셀 간 스케줄링 알고리즘)

  • Kim, Myung-Dong;Seong, Hyeon-Kyeong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.17 no.1
    • /
    • pp.1-9
    • /
    • 2016
  • In this paper, for the improvement of quality of service(QoS) performance of heterogeneous networks, multi-cell scheduling is proposed. In order to implement the proposed algorithm, for the recognition of the impact on the throughput performance of users, macro-pico-cells that form distributed architecture were proposed. In operating heterogeneous networks, considering the centralized structure, a macro-RRH(Remote Radio Head) deployment scenario was proposed. For interference mitigation of the proposed system, by applying the optional sub-frame, through CQI(Channel Quality Indicator) measurement for each sub-frame period, constraint conditions were measured according to system situations. For the simplification, the pattern of the same ABS muting was assumed. In the above two multi-cell environments, the algorithm of high-speed load balancing maintenance was proposed.

Study on the Measurement of Liquid Limit Using a Penetration Resistance of Small Cone in Clay Soil (소형콘의 관입저항력을 이용한 점토의 액성한계측정에 관한 연구)

  • Son, Moorak;Lee, Jaeyong
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.10
    • /
    • pp.5-15
    • /
    • 2016
  • This study investigated both water content and penetration resistance of small cone of various clay soils that were made of Kaolinite and Bentonite with different mixing ratios and compared the results with those of the existing dynamic (Casagrande test) and static (fall cone test) tests directly. The comparison showed that the water content at the inflection point on a curve of water content and penetration resistance was very similar to the liquid limit from a fall cone test. The penetration resistance of small cone at the inflection point was 0.2 kPa, and it was ascertained that the water content at the inflection point represents a liquid limit of clay soils. From the study results, it was found that the penetration resistance of 0.2 kPa with the small cone can be an indicator of the liquid limit of clay soils in practice. Finally a test procedure to measure the liquid limit of clay soil based on a penetration resistance of small cone was proposed.

Knowledge Management of Hospital Clinical Support Department - A Case Study of a Laboratory in S Hospital's Eye Center - (병원 진료지원부서의 역량강화를 위한 지식경영 : S병원 안센터검사실 사례연구)

  • Rhee, Shang-Ro;Kim, Kwang-Jum;Lee, Hyun-Ju
    • Korea Journal of Hospital Management
    • /
    • v.18 no.4
    • /
    • pp.113-130
    • /
    • 2013
  • The aim of this article is to propose a framework for standardization of knowledge based on a case study of clinical operation to guide initial hospital knowledge management projects. Both quantitative and qualitative data for the project from 2009 through 2012 were collected for analysis. In a study of knowledge management project of a lab in S Hospital's Eye Center, this research examines the standardization of operational knowledge for competence enhancement of the lab. The lab defined and standardized the knowledge concern of the lab operation and the in-group from 2008. Organizations are often unaware of the potential value of tacit knowledge in both clinical and administrative area. The main finding from the case study is that analysis of such tacit knowledge of a lab in a hospital can be transformed into explicit knowledge for organizational capabilities such as improved quality, responsiveness and competitive advantage. Concepts from Nonaka's theory are used to investigate processes of knowledge standardization, examining the strategic value of tacit knowledge and the need to rely primarily on internal documentation processes. Since there has been limited research on hospital knowledge management. it may also be useful to researchers in generating propositions for further study.

  • PDF

Comparison of Non-Destructive Testing Images using $^{192}Ir$ and $^{75}Se$ with Computed Radiography System (Computed Radiography 시스템에 $^{192}Ir$$^{75}Se$ 동위원소를 적용하여 촬영한 비파괴검사 영상 비교)

  • Kang, Sang-Mook;Chol, Chang-Il;Lee, Seung-Kyu;Park, Sang-Ki;Kim, Yong-Kyun
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.1
    • /
    • pp.26-33
    • /
    • 2010
  • A computed Radiography (CR) system by use of reusable Image Plate (IP) offers a convenient and reliable way to replace a conventional film-screen system for NDT (non-destructive testing) field. The quality of a radiography to detect a defect of welded objects depends on the procedure embracing several factors such as measurement conditions, image plate type/class, radiation energy, radiation type, and source to image plate distance. Also, the ability of images to detect a flaw reduces with increasing object thickness. In the study, the properties of gamma ray source were summarized for NDT field and inspection images of CR image system manufactured by FUJI were acquired using $^{75}Se$ and $^{192}Ir$ with welded objects. We analyzed the gray scale of hole defect image by using XCAP image processing program and calculated the image contrast and SNR in definition. Also the sesitivities of image quality indicator(IQI) were calculated for hot and cooling tube image of $^{75}Se$ and $^{192}Ir$.

Precision Positioning of a Stationary Transporter Using a Fault Detection and Isolation Method (정적 상태의 이동체 위치 정밀도 향상을 위한 오류 검출 및 배제 기법)

  • An, Jong-Woo;Kim, Yun-Ki;Lee, Jae-Kyung;Lee, Jangmyung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.10
    • /
    • pp.859-868
    • /
    • 2016
  • This paper proposes a new global positioning system (GPS) receiver algorithm to improve the positioning accuracy of a transporter using fault detection and isolation techniques from satellite signals. To improve the positioning accuracy, several factors including a feasible number of satellite signals, SNR, NAV Measurement Quality Indicator (mesQI), and Doppler, among others, have been utilized in the proposed algorithm. To increase the number of feasible satellite signals, an erroneous satellite signal has been replaced by the previous one. In conventional approaches, received GPS signals are analyzed and directly determined to be contaminated or not. The only clean signals are utilized for identifying the current location. This fault detection and isolation (FDI) feasibility test is popular for commercial GPS receivers. In the urban environment, especially near a building, the feasible number of satellite signals becomes insufficient to position the transporter. To overcome this problem, satellite signals are efficiently selected and recovered. Additionally, using the proposed GPS receiver algorithm, a feasible number of satellite signals can be increased, thereby improving the positional accuracy. Real world experiments using a transporter that carries blocks in a shipyard have demonstrated the superiority of the proposed algorithm compared to conventional approaches.

A Study on fairness of broadcasting by AHP (AHP를 활용한 지상파 TV방송의 선거보도 공정성 연구)

  • Park, Seung-Jun;Kim, Dug-Mo
    • Journal of Digital Convergence
    • /
    • v.12 no.11
    • /
    • pp.171-181
    • /
    • 2014
  • As the use of mass media in modern politics grows, its influential power is getting larger than before. Therefore, fairness of broadcasting is identified as a very important factor in the current law. In particular, whether the mass media has balanced attitude toward election issues has been a critical point, which maked the current law have separate provisons to deal with it. As for the fairness and bias, most existing studies had focused on how long the media dealt with the specific political issues, which leads to only quantitative analysis. Also, most analysis of the contents had been based on very personal judgement and evaluation of researchers rather than following the criteria which is based on scientific method. This study introduced the AHP analysis method to compare the quantitative data and qualitative data altogether, which aims to develope the indicator for weighted measures and measurement of the fairness. Research findings reveals that each broadcaster has, MBC was highly biased and KBS and SBS followed that. Compared with existing studies regarding the political fairness of the media.

The Study on Common Cold recorded in Chinese Medical Journal (중의잡지(中醫雜誌)에 보고(報告)된 감모(感冒)에 대(對)한 고찰(考察))

  • Lim, Do-Hee;Bae, Han-Ho;Park, Yang-Chun
    • Journal of Haehwa Medicine
    • /
    • v.13 no.2
    • /
    • pp.231-249
    • /
    • 2004
  • This study analyzed the contents of the research papers concerning the common cold recorded in Chinese medical journal published over the period between 2000 and 2004. As a result, the following conclusion was drawn. 1. Among the clinical research papers, There are a lot of treatment papers of traditional chinese medicine in the method of treatment. There are a lot of papers about Feng-Re-Xing(風熱型) and Xu-Zheng-Xing(虛證型) in the Bian-Zheng-Lei-Xing(辨證類型) 2. "Zhong-Yi-Xu-Zheng-Bian-Zheng-Can-Kao-Biao-Zhun" ("中醫虛證辨證參考標準"), "Zhong-Yi-Nei-Ke-Wu-Ban-Jiao-Cai"("中醫內科五版敎材"), "Zhong-Hua-Ren-Min-Gong-He-Guo-Zhong-Yi-Yao-Hang-Ye-Biao-Zhun"("中華人民共和國醫藥行業標準"), "Gan-Mao-Zhen-Duan-Biao-Zhun"("感冒診斷漂準"), "Zhong-Yi-Bing-Zheng-Zhen-Duan-Liao-Xiao-Biao-Zhun"("中醫病證診斷療效標準"), "Quan-Guo-Gao-Deng-Yi-Xue-Yuan-Xiao-Zhong-Yi-Zhuan-Ye-Jiao-Cai"("全國高等醫藥院校中醫專業敎材") are used as the criterion for diagnosis in Chinese medicine. 3. It is mainly used "Zhong-Yi-Bing-Zheng-Zhen-Duan-Liao-Xiao-Biao-Zhun"("中醫病證診斷療效標準") as the criterion for treatment effect evaluation, and symptom of traditional chinese medicine, the frequency and the duration of common cold, measurement of immunologic function are used as assistant evaluation indicator. 4. The research papers reported that the use of prescriptions such as Chai-Qi-Fang-Jiao-Tang, Tui-Re-He-Ji(退熱合劑), Ti-Xu-Gan-Mao-He-Ji(體虛感冒合劑), Yu-Ping-Feng-San-He-Gui-Zhi-Tang(玉屛風散合桂枝湯), Chai-Guan-Jie-Re-Ke-Li(柴貫解熱顆粒), Hu-Qin-He-Ji(蒿芩合劑), Lian-Hua-Feng-Cha(蓮花峰茶), Kang-Gan-He-Ji(抗感合劑), Bing-Du-He-Ji(病毒合劑), Zhong-Gan-Ling-Pian(重感靈片) led to the high efficacy 5. The pharmacological research papers reported that Yu-Ping-Feng-San(玉屛風散) have influence on IgA, phagocytic function of macrophage, the total number of splenocyte and PEC.

  • PDF

A Study on the Results of the National Evaluation on Public Library Management During 2010~2013 (전국 공공도서관 운영평가의 성과에 관한 연구 - 2010년~2013년도를 중심으로 -)

  • Cha, Mikyeong;Pyo, Soon Hee
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.26 no.2
    • /
    • pp.241-268
    • /
    • 2015
  • Since 2008, the Presidential Committee on Library and Information has conducted 'National Library Management Evaluation,' and almost all of the public libraries have participated in the evaluation. In order to find the effect of the Evaluation on the public libraries, this study analyzed four years of the performance scores (2010~2013) during the period of the $1^{st}$ National Library Development Plan 2009~2013, which used the same measurement, were analyzed by the size groups and regions. The results indicated positive effect on the quality of the internal process such as planning and collection building. Yet attainment gab remains between metropolitan and the other regions, and also different relationship exists between input and attainment among the public library size groups. It suggested the policy development considering the library size and the regional difference.

Electric Fuel Sender Apparatus for the Vehicles Using CPW Transmission Line (CPW 전송선을 이용한 전자식 자동차용 연료 센더 장치)

  • Son Tae-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.4 s.107
    • /
    • pp.380-386
    • /
    • 2006
  • Electric fuel sender fur the vehicle fuel gauge system was designed and fabricated based on the CPW(Co-Planer Waveguide) transmission line theory. It is applied on this system that characteristic impedance of RF transmission line can be varied by the surrounded material of the line. By the characteristic impedance owing the level of gasoline or diesel fuel in vehicle fuel tank, CPW line has corresponding reflected signal as much as changed impedance. Detected signal is amplified, and delivered to fuel indicator into cluster unit on dash board. Conventional floating mechanical buoy level gauge has several defects as low reliability and high break down rate by mechanical operation, and has not good linearity for the fuel level difference. CPW line with electric circuits are constructed on 1.6 mm thickness epoxy substrate, and measurement shows that this system has more accurate level and better linearity than conventional mechanical system. New electric fuel sender which has good productivity with long lifetime and low-in-cost by the SMT chip assembling could be replaced this system with conventional floating buoy system.