• Title/Summary/Keyword: Measurement Indicator

Search Result 495, Processing Time 0.029 seconds

Novel approach for early damage detection on rotor blades of wind energy converters

  • Zerbst, Stephan;Tsiapoki, Stavroula;Rolfes, Raimund
    • Smart Structures and Systems
    • /
    • v.14 no.3
    • /
    • pp.419-444
    • /
    • 2014
  • Within this paper a new approach for early damage detection in rotor blades of wind energy converters is presented, which is shown to have a more sensitive reaction to damage than eigenfrequency-based methods. The new approach is based on the extension of Gasch's proportionality method, according to which maximum oscillation velocity and maximum stress are proportional by a factor, which describes the dynamic behavior of the structure. A change in the proportionality factor can be used as damage indicator. In addition, a novel deflection sensor was developed, which was specifically designed for use in wind turbine rotor blades. This deflection sensor was used during the experimental tests conducted for the measurement of the blade deflection. The method was applied on numerical models for different damage cases and damage extents. Additionally, the method and the sensing concept were applied on a real 50.8 m blade during a fatigue test in the edgewise direction. During the test, a damage of 1.5 m length was induced on the upper trailing edge bondline. Both the initial damage and the increase of its length were successfully detected by the decrease of the proportionality factor. This decrease coincided significantly with the decrease of the factor calculated from the numerical analyses.

The Characteristics and Relationships of Learning Abilities by Brain Preference and EEG According to Elementary School Students Academic Achievement Level (초등학생의 학업성취수준에 따른 뇌 선호도와 뇌파에 의한 학습능력의 특성 및 관계)

  • Kim, Jin Seon;Shim, Jun Young
    • Korean Journal of Child Studies
    • /
    • v.36 no.6
    • /
    • pp.85-100
    • /
    • 2015
  • This study divided elementary school 6th graders of into a higher academic achievement group (n=19) and a lower academic achievement group (n=19) in order to examine the tendency of left and right hemisphere preferences, characteristics and relationships of learning ability factors by means of EEG. For this purpose, brain waves in performing higher cognitive tasks for 5 min. were measured with a two-channel (Fp1, Fp2) EEG measurement system and hemisphere preference was measured by means of a questionnaire. Our results were as follows. First, hemisphere preference indicated that the higher group showed a left hemisphere tendency and the lower group indicated a right hemisphere tendency. Second, the first learning ability test found that the higher group performed its task rapidly with higher levels of concentration and cognitive strength and lower loading and the lower group conducted its task more slowly with lower levels of concentration and cognitive strength and higher loading. The second test showed that the higher group performed its task rapidly with lower levels of concentration.

Comparisons of Physiological and Psychosocial Symptoms for Breast Cancer Patients with and without Lymphedema (유방암 환자의 림프부종 유무에 따른 신체적 및 심리사회적 상태)

  • Park, Jin Hee
    • Korean Journal of Adult Nursing
    • /
    • v.18 no.3
    • /
    • pp.357-366
    • /
    • 2006
  • Purpose: The purpose of this study were to examine the incidence of lymphedema and to compare to physiological and psychosocial symptoms between breast cancer patients with lymphedema and without lymphedema. Method: Four hundreds fifty women with breast cancer receiving mastectomy were recruited from two out-patient breast clinics of A and S university hospitals in Seoul, Korea from October, 2004 to May, 2005. Lymphedema was defined by circumferential measurement. Differences greater than 2cm between the affected arm and normal arm were considered to be lymphedema. A descriptive design was used for this study and data was collected using a structured questionnaire. The data were analyzed using descriptive statistics and independent t-test. Results: Lymphedema developed in 112(24.9%) of the 450 subjects. Subjects with lymphedema reported more severe sensation change of arm and more depression and confusion than subjects without lymphedema. Range of motion of shoulder as a physical indicator and social support, however, were not significantly different between the two groups. Conclusion: Lymphedema is recognized as an unpleasant and uncomfortable consequence of breast cancer-related treatment. Therefore, more research is needed to evaluate the impact of lymphedema on quality of life in patients with lymphedema and the efficacy of nursing intervention.

  • PDF

A Theoretical Study on the Measurement of User Information Satisfaction on the Information System (정보시스템 이용자의 정보만족도 측정에 관한 이론적 고찰)

  • Ahn, Sang-Keun;Choi, Min-Ho;Kim, Sung-Soo
    • Journal of Agricultural Extension & Community Development
    • /
    • v.4 no.1
    • /
    • pp.201-209
    • /
    • 1997
  • The objective of this study were 1) to review concepts of user information satisfaction (UIS), 2) to analyze tools for measuring user information satisfaction, 3) to identify factors affecting information satisfaction. The study was carried out by the analysis of literatures related to information system. The construct of UIS has been operationalized in many different ways. Several studies employed single-item rating scales; such scales have been criticized as unreliable. Single-item scales also provide little information as to what the user finds dissatisfying(satisfying) and are thus of limited utility outside a research setting. Multiple-item UIS measures have become increasingly common. Generally, they are of two types. The first focuses on the information system product. With such diverse names as "system acceptance", "output quality", and "appreciation", these scales focus on the content of the information system and the manner in which the information is presented. The second type of multiple-item scale includes the organizational support for developing and maintaining the system as well as the system product itself. This type of instrument contains items concerned with training, documentation, development procedures, systems maintenance, etc., as well as items related to system content. Thus it provides an indicator of the overall quality of information services provided by an information service function. Generally, UIS measures have not been carefully validated. Recently, however, several rigorous attempts have been made to develop valid and reliable UIS measure.

  • PDF

Development of Disposable Enzyme-linked Immunosensor Strip Platform (일회용 스트립형 효소면역센서용 플랫폼의 개발)

  • Choi, Ji-Hye;Yi, Seung-Jae;Chang, Seung-Cheol;Kim, Kyung-Chun
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.400-405
    • /
    • 2011
  • This study introduced the development of a strip type disposable enzyme-linked immunosensor platform for the detection of IgG. Strips of the strip sensor were fabricated by using commercial nitrocellulose filter membranes and a housing holder for the strips was manufactured by using a standard injection molding process for a plastic material. An IgG-urease conjugate was prepared and used for the competitive immune-binding with sample IgG. From the enzymatic reaction between the conjugated urease and urea added, ammonia was generated and caused a localized alkaline pH change on the immobilized antibody band which was coated onto the sensor strips. This pH increase subsequently caused a color change of the antibody band in the presence of a pH indicator, phenol red. Used in conjunction with a competitive immunoassay format, the intensity of the color produced is directly linked with the concentration of target analyte, IgG, and specific measurement of IgG in a lateral flow immunoassay format was achieved over the range 100 ppb to 2000 ppb IgG.

Development of a Low-cost Automatic Water Quality Diagnosis System for Cooling Towers (저가형 냉각탑 자동 수질 진단 시스템 개발)

  • Kim, Jung Hwan;Park, Han-Bin;Kang, Taesam;Park, Jungkeun
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.58-65
    • /
    • 2014
  • We developed a low-cost automatic diagnosis system for water quality in cooling towers to measure the concentrations of key ingredients such as $Ca^{2+}$, $Cl^-$, $PO{_4}^{3-}$, and $Fe^{2+}$. $Ca^{2+}$, and $Cl^-$ are the main factors that cause the generation of scale, corrosion, and sludge in water pipes. $PO{_4}^{3-}$ prevents corrosion, sludge and scale by inhibiting the ions (i.e., $Ca^{2+}$, $Cl^-$) from sticking to the pipes. $Fe^{2+}$ is an indicator of pipe corrosion. The proposed system consists of a microprocessor, a specimen container and heater, a precision pump, relays and valves, LED optical sources, and photo detectors. It automatically collects water samples and carries out pretreatment for determining the concentration of each chemical, and then estimates the concentration of each ion using low-cost LED optical sources and detectors. Experimental results showed that the accuracy of the proposed system is sufficiently high for water quality diagnosis and management of cooling towers, demonstrating the possibility of the proposed system's wide usage in real environments.

The Characteristics, Detection and Control of Bacteriophage in Fermented Dairy Products (발효유제품에서 박테리오파지의 특성, 검출과 제어)

  • Ahn, Sung-Il;Azzouny, Rehab A.;Huyen, Tran Thi Thanh;Kwak, Hae-Soo
    • Food Science of Animal Resources
    • /
    • v.29 no.1
    • /
    • pp.1-14
    • /
    • 2009
  • This study was to review the classification, detection and control of bacteriophage in fermented dairy products. Bacteriophage has lytic and/or lysogenic life cycles. Epidemiologically speaking, detected major phages are c2, 936 and p335. Among them p335 has been the largest concern in dairy industry. Traditionally, various analytical technologies, such as spot, starter activity, indicator test, ATP measurement and conductimetric analysis, have been used for the phage detection. In recent years, advanced methods such as flow cytometric method, petrifilm, enzyme linked immunosorbent assay (ELISA) and multiflex PCR diagnostic kit have been deveoloped. The phage contamination has been controlled by using heat, high-pressure treatment, and the combinations of heat and pressure, and/or chemical. Also some starter cultures with phage-resistant character have been developed to minimize the concentration of phages in dairy product. Bacteriophage inhibition media such as calcium medium was also mentioned. To prevent the contamination of bacteriophage in dairy industry, further researches on the detection and control of phage, and phage resistant starters are necessary in the future.

Characteristics of Benthic Chlorophyll a and Sediment Properties in the Tidal Flats of Kwangyang Bay, Korea

  • Sin, Yong-Sik;Ryu, Sang-Ock;Song, Eun-Sook
    • ALGAE
    • /
    • v.24 no.3
    • /
    • pp.149-161
    • /
    • 2009
  • Characteristics of benthic microalgae and sediment properties were investigated for the intertidal flats of Kwangyang Bay, Korea. Sampling stations were selected every 100 m in the intertidal flats from land-side to open ocean at two different sampling sites. Samples were collected in June 2004, July, September, November, February and May 2005. Sediments properties were measured including temperature, water contents, sediment bulk density, nutrient concentrations in porewater. Chlorophyll a concentrations in surface sediment (0.5 cm) were measured and relationships between the chlorophyll a and various sediment properties were analyzed to identify major mechanisms regulating biomass of benthic microalgae in the intertidal flats using simple linear regression analysis. Sediment chlorophyll a concentrations were maximum during winter and minimum during warm seasons ranging from 4.4 mg $m^{-2}\;to\;81.2\;mg\;m^{-2}$. No clear spatial variations were observed for the sediment chlorophyll a in the study sites. Results from regression analysis suggested that benthic microalgae biomass was affected by sediment temperature and nutrients especially ammonium and silicate. Grazing effect was estimated using chlorophyll: pheopigments ratio, indirect indicator of grazing activity, and the positive correlation of the ratio and chlorophyll a implied that microalgae biomass is affected by grazing of zoobenthos although direct measurement of grazing activity is required to determine the importance of top-down controls in the benthic microalgae dynamics.

Vibration fatigue prediction using design sensitivity analysis (설계 민감도 해석을 활용한 진동내구 예측방법 연구)

  • Kim, Chan-Jung;Ju, Hyung-Jun;Shin, Sung-Young;Kwon, Sung-Jin;Lee, Bong-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.488-493
    • /
    • 2011
  • Authors previously suggested the design sensitivity analysis based on transmissibility function and identified the sensitivity of measured point over the small modification of system dynamics. On the other hand, the acceleration data will not reveal the strain information at the same location and authors suggested energy isoclines that successfully predict the fatigue damage on the interesting location to overcome the drawback of acceleration over fatigue society. Both of methodologies, sensitivity analysis and fatigue damage prediction, commonly use the response acceleration response as main indicator. In this paper, authors investigate the advanced method of vibration fatigue prediction using design sensitivity analysis to enhance the accuracy of predicted accumulated fatigue. Uni-axial vibration testing is performed with finite element model of a simple notched specimen and the prediction of fatigue damage at notched location is conducted for accelerations at different measurement locations that show different sensitivity contribution, either.

  • PDF

Relationship Between pH and Temperature of Electroless Nickel Plating Solution

  • Nguyen, Van Phuong;Kim, Dong-Hyun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.33.1-33.1
    • /
    • 2018
  • pH is expressed mathematically as $pH=-{\log}[H^+]$, is a measure of the hydrogen ion concentration, [$H^+$] to specify the acidity or basicity of an aqueous solution. The pH scale usually ranges from 0 to 14. Every aqueous solution can be measured to determine its pH value. The pH values below 7.0 express the acidity, above 7.0 are alkalinity and pH 7.0 is a neutral solution. The solution pH can be determined by indicator or by measurement using pH sensor, which measuring the voltage generated between a glass electrode and a reference electrode according to the Nernst Equation. The pH value of solutions depends on the temperature and the activity of contained ions. In nickel electroless plating process, the controlled pH value in some limited ranges are extremely important to achieve optimal deposition rate, phosphorus content as well as solution stability. Basically, nickel electroless plating solution contains of $Ni^{2+}ions$, reducing agent, buffer and complexing agents. The plating processes are normally carried out at $82-92^{\circ}C$. However, the change of its pH values with temperatures does not follow any rule. Thus, the purpose of study is to understand the relationship between pH and temperature of some based solutions and electroless nickel plating solutions. The change of pH with changing temperatures is explained by view of the thermal dynamic and the practical measurements.

  • PDF