• Title/Summary/Keyword: Measurement Indicator

Search Result 495, Processing Time 0.027 seconds

Automated Pressure-Controlled Discography with Constant Injection Speed and Real-Time Pressure Measurement

  • Kim, Hyoung-Ihl;Shin, Dong-Ah
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.1
    • /
    • pp.16-22
    • /
    • 2009
  • Objective : This study was designed to investigate automated pressure-controlled discography (APCD) findings, to calculate the elastance of intervertebral discs, and to assess the relationship between the calculated elastance and disc degeneration. Methods : APCD was performed in 19 patients. There were a total of 49 intervertebral discs treated. Following intradiscal puncture, a dye was constantly injected and the intradiscal pressure was continuously measured. The elastance of the intervertebral disc was defined as unit change in intradiscal pressure per fractional change in injected dye volume. Disc degeneration was graded using a modified Dallas discogram scale. Results : The mean elastance was 43.0${\pm}$9.6 psi/mL in Grade 0, 39.5${\pm}$8.3 psi/mL in Grade 1, 30.5${\pm}$22.3 psi/mL in Grade 2, 30.5${\pm}$22.3 psi/mL in Grade 3, 13.2${\pm}$8.3 psi/mL in Grade 4 and 6.9${\pm}$3.8 psi/mL in Grade 5. The elastance showed significant negative correlation with the degree of degeneration ($R^2$=0.529, P=0.000). Conclusion: APCD liberates the examiner from the data acquisition process during discography. This will likely improve the quality of data and the reliability of discography. Elastance could be used as an indicator of disc degeneration.

The Different of Yangdorak Diagnosis between Low Back Pain Patients and Medical Checkup Group in Korean Males (한국 성인 남성의 요통환자군과 건강검진군의 양도락 검사결과에 대한 비교연구)

  • Kim, Min-Beum;Kim, Sung-Soo;Lee, Jong-Soo
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.20 no.1
    • /
    • pp.109-117
    • /
    • 2010
  • Objectives : The aim of this study was to investigate the different of yangdorak diagnosis between low back pain patients and medical checkup group. Methods : We analyzed the measurement value of yangdorak on 103 patients with low back pain and 103 medical checkup persons in Korean males from March 1st, 2007 to September 30th, 2008 by using yangdorak(MEDIRA, Neomyth Co., Korea). Results : 1. In comparing results on the yangdorak general mean, low back pain group is statistically significant in comparison with medical checkup group(p<0.001). 2. In comparing results on each meridian yangdorak value, they were statistically significant between two groups(p<0.001). 3. In comparing result on the distance of yangdorak value from the mean, they were statistically significant between two groups at the Bladder-meridian(p<0.05), but not at the Kidney-meridian. Conclusions : This results suggest that yangdorak may be used for a method to objective clinical examination. But further studies are required for a use of practical indicator.

A Study on the Design and Implementation of Fine Dust Measurement LED Using Drone

  • Park, Jong-Youel;Ko, Chang-Bae
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.12 no.4
    • /
    • pp.48-54
    • /
    • 2020
  • Researchers recognized air pollution changes causing diseases and difficulties in living due to environmental pollution following various human activities, and have studied how to avoid fine dust harmful to the human respiratory system to be healthy. To this end, Arduino is used to equip fine dust level sensors in drones to measure the fine dust levels, visualize the measurements with LED indicator colors depending on the measurements to inform users of the danger of fine dust, and use the benefits of drones to specify dangerous fine dust zones and measure the fine dust levels. Users can see the changes depending on the fine dust levels in real time with the LED indicators. This will contributes to measuring fine dust levels easily in dangerous areas. Mission Planner (ArduPilot) is used to set up the GPS of drone, and store the data from the dust sensor as contents. This study aims to establish a method for improving the environment to measure fine dust levels with drones with LED indicators for fine dust, and reduce fine dust.

Survey on the Current Disposal Practices of Food Waste left by Patients & Staff in 20 Hospital Foodservices (병원급식소의 환자 및 직원 잔식의 처리 현황 조사)

  • Kim, Hye-Jin;Hong, Wan-Su
    • Journal of the Korean Dietetic Association
    • /
    • v.2 no.2
    • /
    • pp.158-167
    • /
    • 1996
  • Food waste left by patients in hospitals is an important indicator of the nutritional adequacy of the patients' diet and of their satisfaction with food. Food wasted by patients or staff in hospitals is one of the most serious problem in hospital foodservice systems. The purpose of this study was to evaluate the disposal practices of food waste in hospital foodservices for providing basic information for an efficient solid waste management. This approach was achieved using a variety of qualitative and quantitative information including general food waste practices and measurement of food waste left by patients and staff in 20 hospital foodservices. The average food wasted by patients and staff per day was 402.20kg and 206.98kg respectively, being total food waste of 578.08kg per day. The mean plate waste of a staff was 115.95g, which was much lower than that of a patient (221.03g). As means of food waste treatment, most hospitals(60%) are using animal feed, followed by means of collection by contracters(15%) and disposal of waste collection after condensing. An average monthly cost for disposing food waste was 915,000 won and average 138.58 minutes were spent to dispose food waste in hospital foodservices.

  • PDF

Serum neuron specific enolase is increased in pediatric acute encephalitis syndrome

  • Pratamastuti, Dian;Gunawan, Prastiya Indra;Saharso, Darto
    • Clinical and Experimental Pediatrics
    • /
    • v.60 no.9
    • /
    • pp.302-306
    • /
    • 2017
  • Purpose: This study aimed to investigate whether serum neuron-specific enolase (NSE) was expressed in acute encephalitis syndrome (AES) that causes neuronal damage in children. Methods: This prospective observational study was conducted in the pediatric neurology ward of Soetomo Hospital. Cases of AES with ages ranging from 1 month to 12 years were included. Cases that were categorized as simple and complex febrile seizures constituted the non-AES group. Blood was collected for the measurement of NSE within 24 hours of hemodynamic stabilization. The median NSE values of both groups were compared by using the Mann-Whitney U test. All statistical analyses were performed with SPSS version 12 for Windows. Results: In the study period, 30 patients were enrolled. Glasgow Coma Scale mostly decreased in the AES group by about 40% in the level ${\leq}8$. All patients in the AES group suffered from status epilepticus and 46.67% of them had body temperature >$40^{\circ}C$. Most of the cases in the AES group had longer duration of stay in the hospital. The median serum NSE level in the AES group was 157.86 ng/mL, and this value was significantly higher than that of the non-AES group (10.96 ng/mL; P<0.05). Conclusion: AES cases showed higher levels of serum NSE. These results indicate that serum NSE is a good indicator of neuronal brain injury.

Efficiency Analysis of Contract-managed Business and Industry Foodservice Operations Using Data Envelopment Analysis (자료포락분석(DEA)을 이용한 위탁급식전문업체의 산업체 급식소 효율성 평가)

  • Choi, Kyu-Wan;Park, Young-Min;Shin, Seo-Young;Kwak, Tong-Kyung
    • Korean Journal of Community Nutrition
    • /
    • v.12 no.2
    • /
    • pp.178-188
    • /
    • 2007
  • This study was performed to suggest a new efficiency measurement indicator is necessary for evaluating management efficiency of food service operations in contract-managed foodservice companies, to distinguish efficient food service providers and inefficient ones by measuring comparative efficiency among food service operations, and to provide guidance for effective management through showing benchmarking targets for improving inefficient food service providers. The subjects of this study were the 93 B&I foodservice Operations of a domestic contract food service company. The analysis was conducted using CCR model in DEA model. A software, 'Frontier analyst', was used for the analysis. Based on the results derived from comparison of efficiency evaluation classified by providers with use of DEA, it was possible to identify efficient food providers and inefficient providers, and subsequently provide benchmarking guidelines for improvement of the inefficient groups. In analyzing the differences between the results of DEA efficiency evaluation by detailed operation status of food service providers, there was significant difference of efficiency outcomes in terms of contract types, while there was no significant difference in terms of business condition.

Experimental Verifications of Fatigue Crack Identification Method Using Excitation Force Level Control for a Cantilever Beam (외팔보에 대한 가진력수준제어를 통한 피로균열규명기법의 실험적 검증)

  • Kim Do-Gyoon;Lee Soon-Bok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.10
    • /
    • pp.1467-1474
    • /
    • 2004
  • In this study, a new damage identification method for beam-like structures with a fatigue crack is proposed. which does not require comparative measurement on an intact structure but require several measurements at different level of excitation forces on the cracked structure. The idea comes from the fact that dynamic behavior of a structure with a fatigue crack changes with the level of the excitation force. The 2$^{nd}$ spatial derivatives of frequency response functions along the longitudinal direction of a beam are used as the sensitive indicator of crack existence. Then, weighting function is employed in the averaging process in frequency domain to account for the modal participation of the differences between the dynamic behavior of a beam with a fatigue crack at the low excitation and one at the high excitation. Subsequently, a damage index is defined such that the location and level of the crack may be identified. It is shown from the analysis of vibration measurements in this study that comparison of frequency response characteristics of a beam with a single fatigue crack at different level of excitation forces enables an effective detection of the crack.

The Influence of Menu Factors on DEA Menu Efficiency in Contract-Foodservice Operations (위탁 급식 점포의 메뉴 운영 요인이 메뉴 효율성에 미치는 영향)

  • Park, Ju-Yeon;Choi, Kyu-Wan;Kim, Tae-Hee
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.18 no.2
    • /
    • pp.242-252
    • /
    • 2008
  • The objective of this study was to suggest a new efficiency measurement indicator for evaluating the menu management efficiency of decision making units(DMUs) in contract-foodservice operations and to determine the relationship between the DEA(data envelopment analysis) menu efficiency score and menu factors. The results of applying DEA revealed relatively efficient types of service and frequency of meals. The efficient service was shown as a self-service type that operates Monday to Saturday. The considered menu factors included meal price, food cost per meal, meal counts, number of menu items, use of favorite menu use, forecasting error, accuracy of ordering, ratio of inventory, ratio of food loss, use of processed foods and use of prepared vegetables are considered. There were significant correlations between the DEA score and meal price, meal counts, number of menu items, ratio of food loss, accuracy of ordering and use of processed foods respectively. According to the regression results, menu price had a positive influence on the DEA menu efficiency score, and food cost per meal and the use of prepared foods had negative influences respectively.

  • PDF

The Study on the Measurement of Formaldehyde in Hair by HS-GC-MS (헤드스페이스-가스크로마토그래피-질량분석법에 의한 체모 중 포름알데하이드 측정법 연구)

  • Shin Ho-Sang;Ahn Hye-Sil
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.1 s.88
    • /
    • pp.67-70
    • /
    • 2006
  • A gas chromatography/mass spectrometric method was developed for the determination of formaldehyde in hair. 0.3mg of hair was placed in 10ml headspace vial. 1.5mM pentafluorophenylhydrazine solution (pH 2) in 0.03 M phosphoric acid and $20\;{\mu}l$ of 500 mg/l $acetone-d_6$ as internal standard were added in vial and sealed tightly with cap. The solution was heated for 30 min at $90^{\circ}C$ in heating block. The extraction, the derivatization and the evaporation were performed simultaneously. After heating of the solution, 0.5 ml of headspace was taken up and analyzed by gas chromatography-mass spectrometry (GC-MS). Low limit of detection (LaD) and Low limit of quantitation (LOQ) of formaldehyde were 0.5 and 1.5 ng/g, respectively. The method was used to analyze formaldehyde in rat hair after oral exposure. The developed method may be valuable to be used to analyze formaldehyde in human hair.

Pulse wave analysis system using wrist type oximeter for u-Health service (u-Health 서비스 지원을 위한 착용형 옥시미터를 이용한 맥파 분석 시스템)

  • Jung, Sang-Joong;Seo, Yong-Su;Chung, Wan-Young
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.17-24
    • /
    • 2010
  • This paper describes a real time reliable monitoring method and analysis system using wrist type oximeter for ubiquitous healthcare service based on IEEE 802.15.4 standard. Photoplethysmograph(PPG) is simple and cost effective technique to measure blood volume change. In order to obtain and monitor physiological body signals continuously, a small size and low power consumption wrist type oximeter is designed for the measurement of oxygen saturation of a patient unobtrusively. The measured data is transferred to a central PC or server computer by using wireless sensor nodes in wireless sensor network for storage and analysis purposes. LabVIEW server program is designed to monitor stress indicator from heart rate variability(HRV) and process the measured PPG to accelerated plethysmograph(APG) by appling second order derivatives in server PC. These experimental results demonstrate that APG can precisely describe the features of an individual's PPG and be used as estimation of vascular elasticity for blood circulation.