• Title/Summary/Keyword: Measurement Indicator

Search Result 495, Processing Time 0.026 seconds

Indoor Positioning Algorithm Combining Bluetooth Low Energy Plate with Pedestrian Dead Reckoning (BLE Beacon Plate 기법과 Pedestrian Dead Reckoning을 융합한 실내 측위 알고리즘)

  • Lee, Ji-Na;Kang, Hee-Yong;Shin, Yongtae;Kim, Jong-Bae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.2
    • /
    • pp.302-313
    • /
    • 2018
  • As the demand for indoor location recognition system has been rapidly increased in accordance with the increasing use of smart devices and the increasing use of augmented reality, indoor positioning systems(IPS) using BLE (Bluetooth Lower Energy) beacons and UWB (Ultra Wide Band) have been developed. In this paper, a positioning plate is generated by using trilateration technique based on BLE Beacon and using RSSI (Received Signal Strength Indicator). The resultant value is used to calculate the PDR-based coordinates using the positioning element of the Inertial Measurement Unit sensor, We propose a precise indoor positioning algorithm that combines RSSI and PDR technique. Based on the plate algorithm proposed in this paper, the experiment have done at large scale indoor sports arena and airport, and the results were successfully verified by 65% accuracy improvement with average 2.2m error.

The measurement-based analysis of the effect of CQI and BLER on the transmission rate of a LTE system (실측을 통한 CQI와 BLER가 LTE 시스템의 전송 속도에 미치는 영향 분석)

  • Kim, Beom-Joon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.12
    • /
    • pp.1365-1372
    • /
    • 2014
  • In recent, the LTE(Long-Term Evolution) mobile communication system has been commercialized and a variety of service is being provided. Comparing to the old wireless access systems such as 3G mobile communications, in particular, the LTE system supports a service requiring a high transmission rate by providing broadband wireless access. In order to understand the possibility of successful support of a multimedia service such as IPTV(Internet Protocol Television) through the LTE system, it is necessary to understand the mechanism that decides the transmission rate supported by the LTE system. This paper, therefore, discusses on the relationship between a number of metrics such as CQI and BLER that affects the transmission rate with the measurement results from the field tests.

Metrics Measuring a Quality based on Object-Oriented Design Characteristics (객체지향 설계의 특성을 고려한 품질 평가 메트릭스)

  • Kim, Yu-Kyung;Park, Jai-Nyun
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.2
    • /
    • pp.373-384
    • /
    • 2000
  • There are many researches about metrics to measure a quality of Object-Oriented(OO) software. However, most of them have only discussed a concept or properties of metrics, and have not shown the detailed procedure for measuring them. They also define a measurement indicator as a threshold, but it has been influenced on a project size or application domains. In this paper, we propose metrics based on characteristics of OO design such as size, complexity, coupling and cohesion, and use a propotion to an average as the measurement indicator. It is easy to classify classes which have a result above the average, and to predict classes which reduced the quality of OO design. They will be modified to hold the average. Proposed metrics are analytically evaluated by Weyuker's nine properties. They are satisfied with seven properties except two properties co not apply to OO metrics. Also, we design a quality assessment system, ASSOD(ASsessment System of Object oriented Design), to measure the quality of the OO design independent of the platform.

  • PDF

A Comparative Study on the Measurement Model of Anti-Corruption Index : Anti-Corruption Index and CCEJ's Corruption Index (부패지수 측정모형에 대한 비교연구 : 서울시 시정청렴성지수 측정모형과 경실련 부패지수 측정모형을 중심으로)

  • Park, Yong-Chie;Lee, Chung-Min
    • Survey Research
    • /
    • v.6 no.1
    • /
    • pp.1-38
    • /
    • 2005
  • Considering the importance of corruption index measurement model and the diffusion of popular awareness about the importance of anti-corruption, this research compared and analyzed existing corruption index measurement models. This paper has selected "Anti-Corruption Index model(ACI model)" that was developed by Seoul Development Institute and "CCEJ's Corruption Index model" which is under use by the Citizens' Coaltion for Economic Justice. These two models were analyzed in terms of appropriateness of 'the indicator and index choice method', 'the research design' and 'the use of statistical data'. This analysis shows that two models have some problems. First, at the level of indicator and index choice method, the indicators of CCEJ's corruption index model is too atomized and redundant. As not putting weight of indicator, it did not consider importance of each indicator. Citizens who evaluated the level of corruption didn't participate in the weight evaluation team, which results in failure of the model to reflect the citizens' opinion. Also, because the question about Seoul Metropolis' corruption level is not included, it is not detected difference between real corruption level and perceptive corruption level. Second, in terms of appropriateness of research design, the sample of the CCEJ' corruption index model is too small to get credibility. The objectivity of research method seems to be low because survey was performed by exit interview. In addition, 38 items are overfull in the questionnire of CCEJ's corruption index model compare to 13 items in ACI model. Also, in making up questions, the terms are redundant and unobvious. Third, in regarding with feasibility of the statistical data, the CCEJ's corruption index model uses regulation data for disciplinary punishment of 25 local governments in Seoul from 1995 to 1999. But, it is common ideas of scholars that statistical data indicates the tip of an iceberg in corruption. So for using a statistical data, it needs a data of enough quantity and has a high level credibility. In addition, objective method of giving weight is not developed. In this point of view, the use of statistical data has some limits. To solve this problem, ① objective data should be included in the indicators, ② various indicators should be developed and ③ a method of giving weight should be improved.

  • PDF

A Study on Implementation and Design of Web-based Web-Cost Management System: Part 1; Design (웹 기반의 품질코스트 관리시스템 구축 : 제1부;시스템 설계)

  • Chung Young-Bae;Kim Yon-Soo;Kim Jun-Hong
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.27 no.3
    • /
    • pp.97-105
    • /
    • 2004
  • The purpose of this study is to design and implement web-based quality cost management system to measure the performance of quality improvement activities in the business firms. The designed web-based quality cost management system which is also known as WQCMS (Web-based Q-Cost Management System) utilized newly classified objective performance indicator items to measure quality related activities. Well-classified performance measurement Indicator item lists which are played key role in the system was researched and standardized according to size and business categories of enterprise. Its code standards are based from fundamental PAF Model. Developed WQCMS have ability to collect and analyze quality data generated from various different departments in the inside or outside of the enterprise without any limitations, if end-users are able to access wide area network. It provides the capability to integrate quality information from database and to generate various easy analysis reports to management's needs using built-in analysis tool modules with real-time. The proposed system was developed using Microsofi's .Net technology, ASP.NET and MS-SQL Server 2000. By web-enabling Q-cost management system, the effectiveness of the system management and utilization was realized by easiness of information Integration and economical efficiency.

Study on Optical Characteristics of pH Indicators in the Immobilized Film for Fiber-Optic pH Sensor (광학적 pH 센서를 위한 지시염료가 고정된 필름의 광학적 특성 연구)

  • Kim, Beom Kyu;Park, Byung Gi
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.414-419
    • /
    • 2017
  • The optical characteristics of cresol red, phenol red, and neutral red immobilized in the thin film were investigated with absorbance measurement in order to find a sensing part of a fiber-optic pH sensor. Sol-Gel method with tetramethyl orthosilicate as a precursor was used to immobilize the pH indicators in the thin film. The absorbance spectra were measured when pH indicators were immobilized in the film and were dissolved in the buffer solution. Experimental results showed that the absorbance spectra could be changed when the pH indicator is immobilized in the thin film. As compared with other pH indicators, the neutral red exhibited similar absorbance spectra regardless of physical conditions and was sensitive over whole pH range between 4 and 11. In addition, the absorbance ratio of base peak to acid peak tended to increase in proportion to the increase in pH. Experimental results indicate that the neutral red is a good pH indicator for fabrication of a sensing part of the fiber-optic pH sensor.

Relationship between the Measurement Values of the Digital Dust Indicator and Personal Dust Sampler (Digital 분진계와 개인용 분진 포집기의 측정값의 관계)

  • Yoon, Young-No;Lee, Jeong-Joo;Chung, Ho-Keun;Choi, Ho-Chun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.20 no.2 s.22
    • /
    • pp.255-260
    • /
    • 1987
  • The digital dust indicator (Sibata P-5), one of the direct·reading instruments was evaluated for the respirable dust in the underground coal mine environments. As a reference, respirable dust was determined using three cyclones and/or impactors. All the tests were performed on aerosol in twenty underground coal mines. The coefficients of mass-relative concentration were $0.067{\pm}0.054$ (Mean$\pm$Standard deviation) (range: 0.006-0.172). The relationship between relative concentration and temperature was not significant statistically. Also, the relationship of relative concentration and relative humidity was not significant. Mass concentration and relative concentration were $5.31{\pm}5.22mg/m^3$ and $162{\pm}163$ CPM ($Mean{\pm}Standard$ deviation) respectively. The range of mass concentration was $1.22-22.69mg/m^3$; relative concentration 16-628 CPM. The relationship of mass concentration and relative concentration was not significant in these ranges.

  • PDF

Change of End-tidal PCS During Cardiopulmonary Bypass (체외순환시 호기말 이산화탄소압의 변화)

  • 오중환
    • Journal of Chest Surgery
    • /
    • v.25 no.12
    • /
    • pp.1399-1403
    • /
    • 1992
  • The evaluation of the effectivess of ongoing cardiopulmonary resucitation efforts is dependent on the commonly used methods, such as the presence of femoral or carotid artery pulsations, arterial blood gas determinations, peripheral arterial pressure and intracardiac pressure monitoring. But recent studies suggest that end-tidal carbon dioxide tension serves as a non-invasive measurement of pulmonary blood flow and therefore cardiac output under constant ventilation. A prospective clinical study was done to determine whether end-tidal carbon dioxide monitoring in open heart surgery under cardiopulmonary bypass could be used as a prognostic indicator of bypass weaning. We monitored end-tidal PCO2 values continuously during cardiopulmonary bypass in 30 patients. "Ohmeda 5210 CO-2 monitor" under infrared absorption method were incorperated into the ventilator circuit by means of a side point adaptor between endotracheal tube and ventilator tubing. 18 patients[Group I ] were res-ucitated from partial bypass followed by aorta cross clamp off and 12 patients[Group II ] from aorta cross clamp off followed by partial bypass. But there was no difference between two groups[p>0.05]. The value of end-tidal carbon dioxide tension during ventricular fibrillation or nearly arrest state was 6.6$\pm$2.9 mmHg, and at the time of spontaneous beating was 19.3$\pm$5.6 mmHg[Mean$\pm$Standard deviation], In conclusion end-tidal carbon dioxide tension monitoring provides clinically useful, continous, noninvasive and supplementary prognostic indicator during cardiopulmonary bypass weaning procedures.rocedures.

  • PDF

A Empirical Study on the Influences of Core Factor of Knowledge Management on Organizational Effectiveness - Focus on Construction Industry - (지식경영의 핵심요인이 조직유효성에 미치는 영향에 관한 연구 - 건설산업을 중심으로 -)

  • Cho, Kook-Haeng;Hwang, Kyoo-Il
    • Management & Information Systems Review
    • /
    • v.19
    • /
    • pp.145-170
    • /
    • 2006
  • The purpose of this study is to examine the relationship between core factor of Knowledge Management(KM) and organizational effectiveness. The objects of study are middle manager in hosing construction and civil engineering and construction industry, and the sample size is 228. The core factor of KM and indicator of organizational effectiveness are drawn by literature survey. The core factors are classified into human capital, organizational capital, structural capital, (to put it concretely), job capability, human relation, strategy, information technology, process, sharing culture, leadership, measurement. The indicator of organizational effectiveness are measured by job satisfaction, organization loyalty, competitiveness. The main results of this study can be summarized as the following. 1) The core factor of KM has a positive relationship to organizational effectiveness. Especially, the core factor of sharing culture and leadership are strongly relationship with organizational effectiveness. 2) There was a high positive correlation between job satisfaction and organization loyalty. 3) Human, structural, and structural capital had a different affect on organizational effectiveness. 4) The more job position and educational level high, the more they recognized that KM is necessary for their organization. 5) Among the success factor in KM, the factor of job capability was well perceived to respondent. According to this study, we can analyzed the relationship between success factor and organizational effectiveness, and drawn the most influence success factor on organizational effectiveness. Concurrently, the results of this study will be useful guidelines for shaping the KM operation framework in construction industry.

  • PDF

Usage of RSSI in WAVE Handover (WAVE 핸드오버상에서 수신 신호 세기의 이용)

  • Cho, Woong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.6
    • /
    • pp.1449-1454
    • /
    • 2012
  • Received signal strength indicator (RSSI) represents the strength of the received signal at the front end of analog-to-digital convertor (ADC) input. RSSI value can be used for deciding the status of channel at the receiver. In this paper, the usage of RSSI in handover is studied using the practical measurement data. We first measure RSSI in 5.9GHz frequency band which is commonly used in wireless access in vehicular environments (WAVE) system. i.e., vehicular communications. Then, to implement a fast handover, the usability of RSSI data is analyzed based on the measured data. We also apply handover in practical highway environments.