• Title/Summary/Keyword: Measurement Equipment

Search Result 1,714, Processing Time 0.029 seconds

Study on Measurement Accuracy by Auto-Collimation using Theodolite (데오드라이트를 이용한 자동 시준에 의한 측정 정확도에 관한 연구)

  • Lee Byoung-Gi;Kwon Jae-Wook;Yoon Yong-Sik
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1793-1796
    • /
    • 2005
  • The auto-collimation by using theodolite has been accomplished for the straight measurement and the horizontality adjustment. But according to the procedure of auto-collimation or composition of the measurement equipment, an error of the measurement can be occurred. Therefore, this paper accomplished the research for enhancement of measurement accuracy according to measurement procedure of auto-collimation. For that, it has been compared the study of the combination of several precise measurement equipment with using of several theodolite.

  • PDF

Strategies Used by Young Children in Weight Measurement Tasks ($4{\sim}6$세 유아의 무게 측정전략 발달에 관한 연구)

  • Rhee, Bo-Young;Kim, Ju-Young
    • Journal of the Korean Home Economics Association
    • /
    • v.45 no.7
    • /
    • pp.49-60
    • /
    • 2007
  • The purpose of this study was to analyze the weight measurement tasks according to children's ages and whether 4-to 6-year-old children use proper measurement equipment to measure weight. The study subjects were 105 preschool children: 37,38, and 30 4-, 5-, and 6-year-old children, respectively. The results showed that young children use 3 to 4 strategies. They used a strategy to estimate objects visually on the first step in measurement by direct comparison. On the second step, in measurement by nonstandard unit, they held up objects with one hand or two hands. That is, two strategies were shown in measuring objects with hands in this second step. On the third step, which is measured by standard unit, they used a strategy to choose the equal arm balance out of suggested measurement equipment.

A fast high-resolution vibration measurement method based on vision technology for structures

  • Son, Ki-Sung;Jeon, Hyeong-Seop;Chae, Gyung-Sun;Park, Jae-Seok;Kim, Se-Oh
    • Nuclear Engineering and Technology
    • /
    • v.53 no.1
    • /
    • pp.294-303
    • /
    • 2021
  • Various types of sensors are used at industrial sites to measure vibration. With the increase in the diversity of vibration measurement methods, vibration monitoring methods using camera equipment have recently been introduced. However, owing to the physical limitations of the hardware, the measurement resolution is lower than that of conventional sensors, and real-time processing is difficult because of extensive image processing. As a result, most such methods in practice only monitor status trends. To address these disadvantages, a high-resolution vibration measurement method using image analysis of the edge region of the structure has been reported. While this method exhibits higher resolution than the existing vibration measurement technique using a camera, it requires significant amount of computation. In this study, a method is proposed for rapidly processing considerable amount of image data acquired from vision equipment, and measuring the vibration of structures with high resolution. The method is then verified through experiments. It was shown that the proposed method can fast measure vibrations of structures remotely.

Device Development for Measurement of Bed Load and Suspended Particle Movement in Coastal Water and its Application to Field (연안의 부유물 이동 측정 장치 개발과 현장 적용)

  • Lee, Chung Il
    • Journal of Environmental Science International
    • /
    • v.23 no.2
    • /
    • pp.323-330
    • /
    • 2014
  • Transport of bed load and suspended particle in coastal waters is main factor causing change in shoreline, and effective measurement method and appropriate equipment is required. To measure bed load and suspended particle transport an equipment was designed and manufactured, and it was applied in the field. The equipment consists of four main elements, body supporter, bed load and suspended particle sampler, sampler support and lock. Eight samplers were installed along the circumference of each supporter, and each sample is a 45-degree intervals. The field experiment was done once along Gyeongpo beach in August 2013. This note described the design and function of the equipment and results of field experiments.

A Study on Evaluation Criteria and Procedures for Measuring Radiation Leakage of Aviation Security Equipment (항공보안장비 방사선 누출량 측정을 위한 평가 기준 및 절차에 관한 연구)

  • Kihyun Kim;Ye-Eun Jeong;Ye-Jun Kim;Yong Soo Kim
    • Journal of Korean Society for Quality Management
    • /
    • v.51 no.3
    • /
    • pp.435-444
    • /
    • 2023
  • Purpose: To attain advanced performance certification, safety aspects along with functionality and performance are essential. Hence, this study suggests radiation leakage assessment methods for aviation security equipment during its performance certification. Methods: Detection technology guided the choice of radiation leakage assessment targets. We then detailed measurement and evaluation methods based on equipment type and operation mode. Equipment was categorized as container or box types for establishing measurement procedures. Results: We've developed specific radiation leakage assessment procedures for different types of aviation security equipment, crucial for ensuring airport safety. Using these procedures allows efficient evaluation of compliance with radiation leakage standards. Conclusion: The suggested radiation leakage assessment method aims to enhance aviation security and reliability. Future research will focus on identifying risks in novel aviation security equipment detection technologies and establishing safety standards.

Experimental verification and improvement of heat transfer tube local wall temperature measurement method

  • Jiabao Liu;Xiaxin Cao;Peixun Yang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4317-4328
    • /
    • 2023
  • To ensure the measuring accuracy of the wall temperature, the outer wall temperature measurement values by using three kinds of thermocouple welding methods were analyzed and evaluated in the paper, including single-point flush-mounted in the wall groove method, single-point insert-mounted in the wall groove, and outer surface direct welding method, based on the application of a tube-in-tube condensing heat exchanger. And the impacts of silver, tin, and thermal resistance adhesive as filling materials on wall temperature measurement were also investigated, and the results were compared to that obtained without filling materials. The results showed that the wall temperatures measured by the three welding methods were lower than the theoretically calculated value. And the wall temperature measured by the outer surface direct welding method was lowest under the same experimental conditions. The wall temperatures measured by single-point flush-mounted and insert-mounted in the wall groove methods were also affected by different welding filling materials. It was found that the greater the thermal resistance of filling materials, the smaller the heat loss. By analyzing the reasons for the low measured value of wall temperature, a new wall temperature measurement method was developed to improve the accuracy of the current measurement method. Meanwhile, the outer wall temperature measurement experiments of vertical and horizontal heat transfer tubes were carried out to validate and calibrate the improved outer wall temperature measurement method. The results showed that the average outer wall temperature deviation measured by the improved wall temperature measurement method ranged from - 0.82% to +2.29% for vertical tubes and - 4.75% to - 1.44% for horizontal tubes, and the improved measurement method had good measurement accuracy.

A PORTABLE TORQUE AND POWER MEASUREMENT SYSTEM FOR SMALL FARM EQUIPMENT BASED ON AN INSTRUMENTED PULLEY

  • Pasikatan, M.C.;Quick, G.R.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.298-306
    • /
    • 1993
  • A portable torque and power measurement system for small farm equipment based on instrumented pulley was developed. The prototype pulley was machined from mild steel, with spokes serving as strain beams. Strain gages mounted to the spokes sense the bending strain due to the torque and convert this into millivolt output. Calibration results showed the torque-millivolt relationship was linear, while hysterisis and error were less than 1% fs. For power measurements, an additional tachmeter with dcvoltage output is necessary. With the tachometer , error in power measurement was +-1.03W or 0.2% fs. Field tests showed that for ease of installation, no machine alteration needed and safety, this system had advantage over other methods for small farm equipment.

  • PDF

Evaluation Technique of Linearity of Ratio Error and Phase Angle Error of Voltage Transformer Comparison Measurement Equipment (전압변성기 비교 측정 장치의 비오차 및 위상각 오차의 직선성 평가기술)

  • 정재갑;박영태;권성원
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.9
    • /
    • pp.470-474
    • /
    • 2004
  • Both ratio error and phase angle error in voltage transformer(VT) depend on values of burden of VT used. A method of evaluation for linearity of ratio error and phase angle error in VT measurement equipment have been developed using the standard resistance burdens, with negligible AC-DC resistance difference less than $10^-6$. These burden consists of five standard resistors, with nominal resistance of 100 $\Omega$, 1 k$\Omega$, 10 k$\Omega$, 100 k$\Omega$, and 1 M$\Omega$. The developed method has been applied in VT measurement equipment of industry and the validity of the developed method has been verified by showing the consistency of the result of linearity obtained using VT with wide ratio error.

A Study on Image Processing Algorithm fur Inspection of LCD Panel (LCD Panel 불량 검사를 위한 영상처리 알고리즘 연구)

  • Cho S.Y.;Ko K.W.;Ko K.C.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.59-60
    • /
    • 2006
  • It is bringing out the importance of automated LCD testing equipment that satisfy a definite quality, confidence and testing speed, as LCD enterprises are recently expanding the production and facility investment in proportion to the sudden increase of LCD demand. So far, LCD inspection is however conducted by manual, or the confidence of existing testing equipment falls short of LCD enterprises's standard. It is therefore important to develop the testing equipment that determines the quality of product for production of an excellent LCD.

  • PDF