• 제목/요약/키워드: Measurement Devices

검색결과 1,571건 처리시간 0.031초

완전 결핍 SOI MOSFET의 계면 트랩 밀도에 대한 급속 열처리 효과 (Effect of rapid thermal annealing on interface trap density by using subthreshold slope technique in the FD SOI MOSFETs)

  • Jihun Oh;Cho, Won-ju;Yang, Jong-Heon;Kiju Im;Baek, In-Bok;Ahn, Chang-Geun;Lee, Seongjae
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 II
    • /
    • pp.711-714
    • /
    • 2003
  • In this presentation, we investigated the abnormal subthreshold slope of the FD SOI MOSFETs upon the rapid thermal annealing. Based on subthreshold technique and C-V measurement, we deduced that the hump of the subthreshold slope comes from the abnormal D$_{it}$ distribution after RTA. The local kink in the interface trap density distribution by RTA drastically degrades the subthreshold characteristics and mini hump can be eliminated by S-PGA.A.

  • PDF

다수의 계수구역간의 검사체적을 이용한 소형 세포농도센서 (Micro Cell Counter Using a Fixed Control Volume Between Double Electrical Sensing Zones)

  • 이동우;이소연;조영호
    • 대한기계학회논문집A
    • /
    • 제29권12권
    • /
    • pp.1615-1620
    • /
    • 2005
  • We present a novel flow-rate independent cell counter using a fixed control volume between double electrical sensing zones. The previous device based on the single electrical cell sensing in a given flow-rate requires an accurate fluid volume measurement or precision flow rate control. The present cell counter, however, offers the flow-rate independent method for the cell concentration measurement with counting cells in a fixed control volume of $22.9{\pm}0.98{\mu}{\ell}$. In the experimental study, using the RBC (Red Blood Cell), we have compared the measured RBC concentrations from the fabricated devices with those from Hemacytometer. The previous and present devices show the maximum errors of $20.3\%\;and\;16.1\%$, which are in the measurement error range of Hemacytometer (about $20\%$). The present device also shows the flow-rate independent performance at the constant flow-rates ($5{\mu}{\ell}/min$ and $10{\mu}{\ell}/min$) and the varying flow-rate (4, 2, and $4{\mu}{\ell}/min$). Therefore, we demonstrate that the present cell counter is a simple and automated method for the cell concentration measurement without requiring an accurate fluid measurement and precision flow-rate control.

A Measurement System for 3D Hand-Drawn Gesture with a PHANToMTM Device

  • Ko, Seong-Young;Bang, Won-Chul;Kim, Sang-Youn
    • Journal of Information Processing Systems
    • /
    • 제6권3호
    • /
    • pp.347-358
    • /
    • 2010
  • This paper presents a measurement system for 3D hand-drawn gesture motion. Many pen-type input devices with Inertial Measurement Units (IMU) have been developed to estimate 3D hand-drawn gesture using the measured acceleration and/or the angular velocity of the device. The crucial procedure in developing these devices is to measure and to analyze their motion or trajectory. In order to verify the trajectory estimated by an IMU-based input device, it is necessary to compare the estimated trajectory to the real trajectory. For measuring the real trajectory of the pen-type device, a PHANToMTM haptic device is utilized because it allows us to measure the 3D motion of the object in real-time. Even though the PHANToMTM measures the position of the hand gesture well, poor initialization may produce a large amount of error. Therefore, this paper proposes a calibration method which can minimize measurement errors.

저전류 측정을 위한 반도체 소자 특성 분석 시스템에서의 보상 기법 (Calibration Techniques for Low-Level Current Measurement in the Characteristic Analysis System for Semiconductor Devices)

  • 최인규;박종식
    • 센서학회지
    • /
    • 제11권2호
    • /
    • pp.111-117
    • /
    • 2002
  • 본 논문에서는 반도체 소자의 특성 분석을 위한 시스템에서 측정 회로에 의해 발생하는 오차를 감소시켜 측정 정밀도를 개선시키기 위한 보정 과정을 제안하였다. 또한 pA 수준의 저전류 측정을 위해서 누설 전류, 오프셋 전류와 같은 오차 전류를 감소시키기 위한 보상 기법을 제안하였다. 보정계수는 마이크로프로세서에 의해 보정 과정에서 수집된 데이터로부터 구해진다. 수집된 데이터를 최소 자승 오차법을 사용하여 다항식으로 근사하는 방법으로 보정 계수를 계산하고 저장한다. 측정 시에는 마이크로프로세서가 저장된 보정 계수를 사용하여 측정 오차를 교정하여 준다. 실험 결과에서 nA 이상의 전류를 측정할 경우 측정 오차가 0.02% 이하를 가지며 pA 수준의 저전류도 0.2% 정도의 오차로 측정 가능함을 확인하였다.

직류전류측정기의 안전성 향상을 위한 고내구성 보호소자의 가용체 설계 (Design for a Fuse of High Durability Protection Elements for Improving the Safety of DC Current Measurement Device)

  • 이예지;윤재서;조성철;노성여
    • 한국전기전자재료학회논문지
    • /
    • 제33권3호
    • /
    • pp.201-207
    • /
    • 2020
  • With the expansion in the use of DC power systems and increased need for system maintenance, the development of measurement devices for maintenance requires high stability. Of the different kinds of DC current measurement devices, the single-shot measurement device causes the input signal of the current measuring unit to initially generate a high inrush current. The high inrush current flows into the signal processor of the meter, shortening the life of the internal fuses and causing failure. Therefore, in this study, the I2t value for increasing the durability of the fuse is designed using the available wire diameter. Operating characteristics for 210~400% over-current of the rated current, which is relatively low over-current, are realized by the plating of low melting tin metal. As a result, a method of designing a fuse element for a DC power supply, which improves the safety of the DC current measurement device by blocking the failure caused by the inrush current, is presented.

토노메트리 방식 맥파 측정의 가압 각도에 따른 변동성 평가 (Variation Factor Assessment of Radial Artery Pulse by the Tonometry Angle of the Pulse Pressure Sensor)

  • 정창진;조정희;전민호;전영주;김영민
    • 센서학회지
    • /
    • 제25권2호
    • /
    • pp.138-142
    • /
    • 2016
  • A pulse measurement by tonometry provides useful information for diagnosis, including not only blood pressure and heart rate but also parameters for estimating a condition of the cardiovascular system. Currently, various pulse measurement devices based on the tonometry have been developed. A reliability of these devices is determined by a positioning technic between the sensor and the blood vessel and a controlling technique of the pressurization level. An angle of the sensor for the pulse measurement seems to be highly related with a measured signal, however, the objective studies for this issue have been not published. In this paper, the variation of the pulse signals by tonometry direction was experimentally assessed according to the angle of the sensor. In order for guaranteeing the repeatability of the experiment, we used a pulse generator device, which can generate human pulse signal by using silicon tube and fluid pump, and developed a structure for precise adjustment of the angle and the pressurization level of the sensor. The angle of the sensor was acquired by an inclinometer, which was attached at the opposite side of the sensor. As results, a coefficient of variation (CV) of a maximum amplitude (MA) of the pulse wave was largely increased over the angle range of $-9{\sim}9^{\circ}$. Furthermore, the changes of the pulse shape showed different aspects according to the sign of the angle tilted along the blood vessel. It is expected that the results of this study can be helpful for developing more precise pulse measurement devices based on the tonometry and applying in clinic.

A Study on Displacement Measurement by A Laser Interferometry using Common-path Fiber-optical Devices

  • Lee, Seok-Soon;Lee, Dong-Wook;Park, Min-Hyeok;Choi, Jin-Gyu;Nam, Kwang-Sik;Zhao, Shang
    • International Journal of Aerospace System Engineering
    • /
    • 제1권1호
    • /
    • pp.29-33
    • /
    • 2014
  • A displacement measurement system that uses fiber-optical common-path interferometry has been developed. The system includes fiber-optic devices and a collimator attached to a linear translation stage. The interferometry effect was detected with a photodetector whose signal was measured on an oscilloscope. Experiments showed that vibration of the stage disturbed the signal by causing nanoscale interference. Under stable conditions, the measured distance was the almost the same as the value calculated from the linear translation stage parameters.

Apparatus and Method of Visual Lifetime Measurement of Organic Light Emitting Devices

  • Yang, Yong-Suk;Chu, Hye-Yong;Oh, Ji-Young;Lee, Jeong-Ik;Kim, Gi-Heon;KoPark, Sang-He;Hwang, Chi-Sun;Kim, Mi-Kyung;Do, Lee-Mi;Chung, Sung-Mook;Ko, Young-Wook
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.623-624
    • /
    • 2004
  • The coating and estimation of gas and moisture barriers on polymer and glass substrates are receiving very much attention in passivation of organic light emitting devices (OLEDs). In this study, the encapsulation and lifetime measurement techniques of OLEDs were presented. The degradation mechanisms of bare and encapsulated OLEDs were investigated by the visual lifetime measurement (VLM) system with the parameters such as a pixel luminance(L), a luminance rms roughness(dL), a brightness area ratio(R), an edge degradation depth(D), etc.

  • PDF

마이크로 성형기에서 미세 변위 측정을 위한 레이저 간섭계 개발에 관한 연구 (A Study on Laser Interferometer Development for Micro Displacement Measurement in Micro Former)

  • 최재원;김대현;최경현;이석희;김승수;나경환
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1195-1198
    • /
    • 2003
  • Micro former has been known as a useful tool for machining micro parts. It makes micro holes automatically with punches, a hole-shape die and material by rotation of crank shaft synchronously. Micro displacement in micro forming affects on the performance of machining because micro forming size is similar with its mechanical displacement. Therefore, the measurement of this micro displacement is essential to be guaranteed to obtain high forming precision in the whole machine as well as its devices. This paper addresses the development of a laser interferometer to measure micro displacement for a micro former. The laser interferometer is able to measure micro displacement during a few micro seconds with non-contact. For the experiment, a laser probe is installed on the optical table with optical devices and a micro displacement generating device. The velocity decoding board is also added to calculate doppler shift frequency directly. Finally simple experiments are conducted to confirm its functional operation.

  • PDF

유무선송수신을 이용한 심층혼합처리공법 수직도 및 심도 자동측정에 관한 연구 (Wire and Wireless Transmitting-Receiving Set for Vertical Angle and Depth Measurement of Deep Mixing Method)

  • 한우선;유찬;한만복
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.629-634
    • /
    • 2002
  • Demands for the automatic measurement on angle and depth of equipment were arisen for the better construction in deep mixing method and grouting method. Civil, geotechnical, electronic, and communication experts worked together for the development of automatic measuring devices using wire and wireless transmitting-receiving set. The results on the development of automatic devices in an industrial installation will be presented.

  • PDF