• Title/Summary/Keyword: Measurement Angle

Search Result 2,166, Processing Time 0.03 seconds

Analysis of the Surface Characterisitics of Microstickies by Contact Angle Measurement (접촉각 측정을 통한 스틱키의 표면화학적 특성 분석)

  • Park, Il;Lee. Hak-Lae
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.37 no.2 s.110
    • /
    • pp.21-29
    • /
    • 2005
  • Increase in the utilization rate of recycled paper has significantly increased the problem associated with stickies. Despite the effort to eliminate contaminants from recycled furnishes, stickies are still the most serious obstacle in using recycled paper. The amount of micro stickies that are too small to be eliminated by screening, tends to increase significantly as the closure level of white water system is increased and the quality of raw material deteriorates. To establish a process efficient in removing micro stickies is strongly required. In this study, the surface characteristic of micro stickies was investigated with contact angle measurement. Surface energies of MCC, PSA film and model micro stickies were 53.37 mN/m, 29.75mN/m, and 29.63mN/m, respectively. This indicates that the surface characteristic of MMS is very similar to PSA. Thus, solvent coating of PSA and evaporation of the solvent provided excellent model micro stickies for flotation experiment.

Study of Tunnel Face Mapping Using Tunnel Mapper (Tunnel Mapper를 이용한 Tunnel 막장면 조사에 관한 연구)

  • Kwak, No-Kyung;Cho, Sung-Jin;Lee, Song
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09b
    • /
    • pp.200-211
    • /
    • 2010
  • Tunnel Mapper, which is tunnel face survey system was used to conduct Face Mapping on the face of the tunnel that is under construction. Then, accuracy and utility value on the forecast of discontinuity were verified to verify the field application in order to present the measures for the use of the system for conducting research on the discontinuity. As result of the directivity verification following discontinuity‘s project, forecasted measurement and actually researched measurement error for the Dip direction and Dip angle was less than ${\pm}10$. Accuracy was 82.6% for Dip direction and 90.7% for Dip angle, which are high. Accordingly, face research discontinuity forecasting system's reliability level towards directivity is high. Tunnel Mapper, a tunnel face survey system can be leveraged to replace face's visual survey and to obtain objective information, enabling execution of the survey system that can automate face survey going beyond time and space related limitations.

  • PDF

A Study on the Fluid Flow with Ultrasonic Forcing by PIV Measurement - On the Incident Angle and Reflector - (초음파가 가진된 유체유동의 PIV계측에 의한 연구 - 입사각과 반사재료를 중심으로 -)

  • Ju, E.S.;Lee, Y.H.;La, W.J.;Park, Y.H.
    • Journal of Power System Engineering
    • /
    • v.4 no.4
    • /
    • pp.32-40
    • /
    • 2000
  • A study on the fluid flow with ultrasonic forcing was carried out to get the enhancement of turbulence by laying emphasis on the ultrasonic incidence angles and reflectors. A large water tank was made of the transparent acrylic plates and city water of $25^{\circ}C$ was used as working fluid. 7 angles ($30^{\circ},\;45^{\circ},\;60^{\circ},\;90^{\circ},\;120^{\circ},\;135^{\circ},\;150^{\circ}$) as the ultrasonic incidence angle and 4 materials (wood, acryl, glass, iron) as the reflector were selected arid experiments for the above were made. The velocity vector distribution, kinetic energy and turbulence intensity of the turbulence flow fields enhanced by ultrasonic forcing were measured, compared and discussed by using the PIV measurement which was possible to measure the velocities of simultaneous multipoints. In results, it was cleared that the incidence angle of ultrasonic and material of reflector influenced the enhancement of turbulence.

  • PDF

A Fault Diagnosis and Control Integrated System for an SP-100 Space Reactor (SP-100 우주선 원자로를 위한 고장진단 및 제어 통합 시스템)

  • Na, Man-Gyun;Yang, Heon-Young;Lim, Dong-Hyuk;Lee, Yoon-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.231-232
    • /
    • 2007
  • In this paper, a fault diagnosis and control integrated system (FDCIS) was developed to control the thermoelectric (TE) power in the SP-100 space reactor. The objectives of the proposed model predictive control were to minimize both the difference between the predicted TE power and the desired power, and the variation of control drum angle that adjusts the control reactivity. Also, the objectives were subject to maximum and minimum control drum angle and maximum drum angle variation speed. A genetic algorithm was used to optimize the model predictive controller. The model predictive controller was integrated with a fault detection and diagnostics algorithm so that the controller can work properly even under input and output measurement faults. With the presence of faults, the control law was reconfigured using online estimates of the measurements. Simulation results of the proposed controller showed that the TE generator power level controlled by the proposed controller could track the target power level effectively even under measurement faults, satisfying all control constraints.

  • PDF

A Study on the Correlation beween Visual Excess and Height Measuring Precision (과고감과 표고측정정밀도와의 상관관계에 관한 연구)

  • 최재화;운홍식
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.4 no.2
    • /
    • pp.10-26
    • /
    • 1986
  • In a stereoscopic measurements on the aerial photogrammetric works, it is in general understood that the larger and the larger is a vertical scale exaggeration, the better and the better is height measuring precision. Despite the success with which a stereoscopic measurement has been applied to contour mapping as well as spot height measurement, no generally accepted theory for visual excess has yet been developed. This experiments aim at arrangement of a correlation between visual excess and height measuring precision. The stereoscopic measurements with parallax bar in the mirror stereoscope are carried out on the test model of which consists normal angle, wide angle and super wide angle respectively. With the result of this experiments, it is conclued that height measuring precision is proportional to the magnitude of visual excess.

  • PDF

Evaluation of craniofacial morphology in short-statured children: growth hormone deficiency versus idiopathic short stature

  • Kim, Ki Bong;Kim, Eun-Kyong;Jang, Kyung Mi;Kim, Min Seon;Park, Eun Young
    • Journal of Yeungnam Medical Science
    • /
    • v.38 no.1
    • /
    • pp.47-52
    • /
    • 2021
  • Background: Short stature is defined as a height below the 3rd percentile or more than two standard deviations below the mean for a given age, sex, and population. There have been inconsistent results regarding craniofacial morphology in short-statured children. This study aimed to analyze the differences between short-statured children with growth hormone deficiency, idiopathic short-statured children, and normal children. Methods: Thirty-one short-statured children with growth hormone deficiency, 32 idiopathic short-statured children, and 32 healthy children were enrolled in this study. The measurements of their craniofacial structures from lateral cephalograms were evaluated. Results: There were statistically significant differences among the three groups seven variables (anterior cranial base length, posterior cranial base length, total cranial base length, upper posterior facial height, posterior total facial height, mandibular ramus length, and overall mandibular length) in the linear measurement and five variables (saddle angle, gonial angle, mandibular plane angle, position of mandible, and maxilla versus mandible) in the angular measurement. Conclusion: Compared to the control group, many linear and angular measurements of the craniofacial structures were significantly different in the two short-statured groups (p <0.05). Treatment plans by orthodontists should include these craniofacial structure characteristics.

Development of Head Mounted Display Interface System for Controlling Wireless Capsule Endoscope (무선 캡슐내시경 조종을 위한 머리부착형 디스플레이 인터페이스 시스템의 개발)

  • Young-Eun, Hwang;Young-Don, Son
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.6
    • /
    • pp.417-423
    • /
    • 2022
  • The present study proposed a new interface system for capsule endoscopy by using head mounted display (HMD) device, which can control the orientation of the capsule endoscope with electromagnetic actuator (EMA) system. The orientation information of the HMD user was detected by the gyroscope sensor built into the device and then calculated to as an angle increment using Unity Engine compiler. The measured angle changes from the HMD were converted to the current values of the corresponding coils to be changed in the EMA system. Two experiments were designed to measure the accuracy and the intuitiveness of the HMD interface system. In the angle accuracy measurement, the capsule endoscope driven by HMD interface system showed the averaged errors of 0.68 degrees horizontally and 1.001 degrees vertically for given test angles. In the intuitiveness measurement, HMD interface system showed 1.33 times faster manipulation speed rather than the joystick interface system. In this respect, the HMD interface system for capsule endoscopy was expected to improve the overall diagnostic environment while maintaining comfort of patients and clinicians.

Study on The Estimation Method of the Joint for the Operation of the Upper Limb Rehabilitation Equipment for Hemiplegic Patients II (편마비 환자의 상지 재활 기기 운용을 위한 관절 각 추정 기법에 관한 연구 II)

  • Song, K.S.;Eom, S.H.;Lee, E.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.8 no.4
    • /
    • pp.313-318
    • /
    • 2014
  • In this paper, we propose a method for correcting the measurement axis twist that occurs in the process of wearing and each estimation method of joint in which the inertial measurement unit based in health arm by the method of operation upper limb rehabilitation equipment of hemiplegic patients. In order to verify the proposed method, it is fitted with a inertial measurement unit of the upper arm and forearm of the experimenter left arm, verified by comparing actual joint angle is detected by photographing the arbitrary posture, the angle that the estimated joint. Then, it was verified by comparing the applied front / rear techniques for correcting the measurement axis twist. A result of the experiment, before applying the measurement axis twist correction, joint, after but each match rate showed a weak concordance rate in 89.16% and were corrected, measurement axis twist, each concordance rate of joint agreement of 93.28% I understand that it has been 4.12% improvement in the rate.

  • PDF

Realization of a High Precision Inspection System for the SOP Types of ICs (SOP형 IC의 고 정밀 외관검사 시스템 구현)

  • Tae Hyo Kim
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.5 no.2
    • /
    • pp.165-171
    • /
    • 2004
  • Owing to small sizes and high density to the semiconductor It, it is difficult to discriminate the defects of ICs by human eyes. High precision inspection system with computer vision is essentially established for the manufacturing process due to the variety of defective parts. Especially it is difficult to implement the algorithm for the coplanarity of IC leads. Therefore in this paper, the inspection system which can detect the defects of the SOP types of ICs having 1cm${\times}$0.5cm of the chip size is implemented and evaluated it's performance. In order to optimally detect various items, some principles of geometry are theoretically presented , length measurement, pitch measurement, angle measurement, brightness of image and correcton of position. The interface circuit is designed for implementation of inspection system and connected the HANDLER. In the result, the system could detect two ICs' defects per second and confirmed the resolution of 20$\mu$m per pixel.

  • PDF

Ultrasonographic evaluation of pennation angle in canine tibialis cranialis muscle in South Korea: an observational study

  • Jaehwan Kim;Tae Sung Hwang;Hee Chun Lee
    • Korean Journal of Veterinary Research
    • /
    • v.64 no.2
    • /
    • pp.14.1-14.6
    • /
    • 2024
  • In human, ultrasonography is used to measure the pennation angle in various muscles to identify muscle functions such as force production, and to study alterations of the pennation angle during muscle contraction, hypertrophy, and atrophy. However, assessments of the pennation angle have not yet been conducted in dogs. This study aims to assess the normal pennation angle of the tibialis cranialis muscle in dogs using ultrasound and to detect changes in this angle in dogs with muscular atrophy. Sixty-eight healthy dogs were examined to establish normal values, while 12 ataxic and 12 lame dogs with suspected hindlimb muscle atrophy were also included. The pennation angle was measured using ultrasound at the midpoint between the proximal end of the tibia and the malleolus, measuring the angle between the muscle bundle and the deep aponeurosis. To confirm the significance between the 5 breeds and to identify a difference between normal and atrophied muscles, statistical analysis was conducted. The study found no significant difference in pennation angle between breeds, with mean values (± standard deviation) of 4.97° (± 1.88) in neutral, 7.25° (± 2.68) in flexion, and 3.31° (± 1.33) in extension positions. Decrease of the pennation angle was identified in muscle atrophy and the flexion position was determined to be the most appropriate for pennation angle measurement of tibialis cranialis muscle. We recommend considering the pennation angle as a valuable indicator of muscle health in dogs, as it demonstrates significant potential for diagnosing and monitoring muscular conditions.