The Corrosion Inhibition Characteristics of Sodium Nitrite Using an On-line Corrosion Rate Measurement System (온라인 부식속도 측정 시스템을 이용한 아질산 나트륨의 금속 부식억제 특성 연구)

  • Park, Mal-Yong;Moon, Jeon-Soo;Kang, Dae-Jin
    • Corrosion Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.85-92
    • /
    • 2015
  • An on-line corrosion rate measurement system was developed using a personal computer, a data acquisition board and program, and a 2-electrode corrosion probe. Reliability of the developed system was confirmed with through comparison test. With this system, the effect of sodium nitrite ($NaNO_2$) as a corrosion inhibitor were studied on iron and aluminum brass that were immersed in sodium chloride (NaCl) solution. Corrosion rate was measured based on the linear polarization resistance method. The corrosion rates of aluminum brass and iron in 1% NaCl solutions were measured to be 0.290 mm per year (mmpy) and 0.2134 mmpy, respectively. With the addition of 200 ppm of $NO{_2}^-$, the corrosion rates decreased to 0.0470 mmpy and 0.0254 mmpy. The addition of $NO{_2}^-$ caused a decrease in corrosion rates of both aluminum brass and iron, yet the $NO{_2}^-$ acted as a more effective corrosion inhibitor for iron. than aluminum brass.

Experiments on a Regenerator with Thermosyphon for Absorption Heat Pumps (기포 펌프를 적용한 흡수식 열펌프용 고온 재생기의 작동 특성 실험)

  • Park, C.W.;Jurng, J.;Nam, P.W.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.4
    • /
    • pp.463-472
    • /
    • 1996
  • Experiments were carried out to study the operation characteristics of a regenerator with a thermo-syphon pump and a surface-flame burner for a lithium bromide (LiBr)-water absorption heat pump. A cylindrical-shape metal-fiber burner and commercial grade propane were used. The emission of carbon monoxide and nitric oxide was measured by a combustion gas analyzer. Ther regeneration rate of water vapor as a refrigerant was measured. It could be as a reference value showing the performance of the regenerator. The circulation rate of the LiBr-water solution was also measured from both the tanks for the weak-and the strong-solution. Using a refractometer, the LiBr concetration in the solution was calculated from the measured refractory index of the solution. Temperature of the solution and the condensed water was recorded at several points in the experimental apparatus with thermocouples, using a personal computer. This data collecting system for measuring temperature was calibrated with a set of standard thermometers. The generating rate of water vapor as refrigerant increased linearly with heat supplied. It was about 4.0g/s with the heat supplied at a rate of 16,500kcal/h. The circulation rate of LiBr solution also increases with the heat supplied. The difference in LiBr concentrations between the weak and the strong solution was in the range of 1 to 5% when the concentration of the strong solution was about 60%. It was dependent upon both the heat supplied and the circulation rate of the solution. The initial concentration and the level of the LiBr solution in the regenerator were measured and recorded before experiments. The effect of them on the generating rate of water vapor and the circulation rate of the solution was also studied. The generating rate of water vapor was not strongly dependent upon both the level of the LiBr solution and the initial LiBr concentration. However, the concentration difference of the solution increases with the initial level of the LiBr solution.

  • PDF

Development of Real-Time Mental Work Load Measurement System using Heart Rate Variability base on Personal Computer (심박변화율을 이용한 PC 기반 실시간 정신작업부하 측정시스템 개발)

  • 고한우;윤용현;양희경;김동윤
    • Science of Emotion and Sensibility
    • /
    • v.4 no.1
    • /
    • pp.1-5
    • /
    • 2001
  • The evaluation of mental workload is measured by subjective ratings, physiological signals. It takes long time to analysis the measured signals and is very tedious and time-consumming work. Therefore, to evaluate the affect of workload effectively, real-time measurement system is required. In this paper, real-time mental workload measurement system using cardiac autonomic indiced which reflect well the mental workload was developed and evaluated. Analyzed indices were HR, IBI, Lorentz plot, CSI, CVI, and LF/HF ratio of heart rate variability. The system was applied to evaluate the affect of arithmetic task and showed good results. This system was consisted of ECG amplifier, A/D converter, and personal computer, and algorithm was implemented using LabVIEW.

  • PDF

The Properties of Boron-doped Zinc Oxide Film Deposited according to Oxygen Flow Rate

  • Kim, Dong-Hae;Son, Chan-Hee;Yun, Myoung-Soo;Lee, Jin-Young;Jo, Tae-Hoon;Seo, Il-Won;Jo, I-Hyun;Roh, Jun-Hyung;Choi, Eun-Ha;Uhm, Han-Sup;Kwon, Gi-Chung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.358-358
    • /
    • 2012
  • The application of BZO (Boron-doped Zinc Oxide) films use as the TCO(Transparent Conductive Oxide) material for display and solar cell industries, where the conductivity of the BZO films plays a critical role for improvement of cell performance. Thin BZO films are deposited on glass substrates by using RF sputter system. Then charging flow rates of O2 gas from zero to 10 sccm, thereby controlling the impurity concentration of BZO. BZO deposited on soda lime glass and RF power was 300 W, frequency was 13.56 MHz, and working pressure was $5.0{\times}10-6$ Torr. The Substrate and glass between distance 200 mm. We measured resistivity, conductivity, mobility by hall measurement system. Optical properties measured by photo voltaic device analysis system. We measured surface build according to oxygen flow rate from XPS (X-ray Photoelectron Spectroscopy) system. The profile of the energy distribution of the electrons emitted from BZO films by the Auger neutralization is measured and rescaled so that Auger self-convolution arises, revealing the detail structure of the valence band. It may be observed coefficient ${\gamma}$ of the secondary electron emission from BZO by using ${\gamma}$-FIB (Gamma-Focused Ion Beam) system. We observed the change in electrical conductivity by correlation of the valence band structure. Therefore one of the key issues in BZO films may be the valence band that detail structure dominates performance of solar cell devices. Demonstrating the secondary electron emission by the Auger neutralization of ions is useful for the determination of the characteristics of BZO films for solar cell and display developments.

  • PDF

A study on the measurement of plastic zone and crack growth length at the crack tip under cyclic loading using ESPI system

  • Kim, Kyung-Su;Kim, Ki-Sung;Shim, Chun-Sik
    • Structural Engineering and Mechanics
    • /
    • v.15 no.3
    • /
    • pp.367-378
    • /
    • 2003
  • The magnitude of the plastic zone around the crack tip of DENT (Double Edge Notched Tension) specimen and the crack growth length under cyclic loading were measured by ESPI (Electronic Speckle Pattern Interferometry) system. The measured magnitude of plastic zone was compared with the proposed by Irwin and calculated by a nonlinear static method of MSC/NASTRAN. The measured crack growth length by ESPI system was also compared with the obtained data by the image analysis system. From the study, it is confirmed that the plastic zone and crack growth length can be measured accurately with the high-tech equipment (ESPI System).

Glass Dissolution Rates From MCC-1 and Flow-Through Tests

  • Jeong, Seung-Young
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.257-258
    • /
    • 2004
  • The dose from radionuclides released from high-level radioactive waste (HLW) glasses as they corrode must be taken into account when assessing the performance of a disposal system. In the performance assessment (PA) calculations conducted for the proposed Yucca Mountain, Nevada, disposal system, the release of radionuclides is conservatively assumed to occur at the same rate the glass matrix dissolves. A simple model was developed to calculate the glass dissolution rate of HLW glasses in these PA calculations [1]. For the PA calculations that were conducted for Site Recommendation, it was necessary to identify ranges of parameter values that bounded the dissolution rates of the wide range of HLW glass compositions that will be disposed. The values and ranges of the model parameters for the pH and temperature dependencies were extracted from the results of SPFT, static leach tests, and Soxhlet tests available in the literature. Static leach tests were conducted with a range of glass compositions to measure values for the glass composition parameter. The glass dissolution rate depends on temperature, pH, and the compositions of the glass and solution, The dissolution rate is calculated using Eq. 1: $rate{\;}={\;}k_{o}10^{(ph){\eta})}{\cdot}e^{(-Ea/RT)}{\cdot}(1-Q/K){\;}+{\;}k_{long}$ where $k_{0},\;{\eta}$ and Eaare the parameters for glass composition, pH, $\eta$ and temperature dependence, respectively, and R is the gas constant. The term (1-Q/K) is the affinity term, where Q is the ion activity product of the solution and K is the pseudo-equilibrium constant for the glass. Values of the parameters $k_{0},\;{\eta}\;and\;E_{a}$ are the parameters for glass composition, pH, and temperature dependence, respectively, and R is the gas constant. The term (1-Q/C) is the affinity term, where Q is the ion activity product of the solution and K is the pseudo-equilibrium constant for the glass. Values of the parameters $k_0$, and Ea are determined under test conditions where the value of Q is maintained near zero, so that the value of the affinity term remains near 1. The dissolution rate under conditions in which the value of the affinity term is near 1 is referred to as the forward rate. This is the highest dissolution rate that can occur at a particular pH and temperature. The value of the parameter K is determined from experiments in which the value of the ion activity product approaches the value of K. This results in a decrease in the value of the affinity term and the dissolution rate. The highly dilute solutions required to measure the forward rate and extract values for $k_0$, $\eta$, and Ea can be maintained by conducting dynamic tests in which the test solution is removed from the reaction cell and replaced with fresh solution. In the single-pass flow-through (PFT) test method, this is done by continuously pumping the test solution through the reaction cell. Alternatively, static tests can be conducted with sufficient solution volume that the solution concentrations of dissolved glass components do not increase significantly during the test. Both the SPFT and static tests can ve conducted for a wide range of pH values and temperatures. Both static and SPFt tests have short-comings. the SPFT test requires analysis of several solutions (typically 6-10) at each of several flow rates to determine the glass dissolution rate at each pH and temperature. As will be shown, the rate measured in an SPFt test depends on the solution flow rate. The solutions in static tests will eventually become concentrated enough to affect the dissolution rate. In both the SPFt and static test methods. a compromise is required between the need to minimize the effects of dissolved components on the dissolution rate and the need to attain solution concentrations that are high enough to analyze. In the paper, we compare the results of static leach tests and SPFT tests conducted with simple 5-component glass to confirm the equivalence of SPFT tests and static tests conducted with pH buffer solutions. Tests were conducted over the range pH values that are most relevant for waste glass disssolution in a disposal system. The glass and temperature used in the tests were selected to allow direct comparison with SPFT tests conducted previously. The ability to measure parameter values with more than one test method and an understanding of how the rate measured in each test is affected by various test parameters provides added confidence to the measured values. The dissolution rate of a simple 5-component glass was measured at pH values of 6.2, 8.3, and 9.6 and $70^{\circ}C$ using static tests and single-pass flow-through (SPFT) tests. Similar rates were measured with the two methods. However, the measured rates are about 10X higher than the rates measured previously for a glass having the same composition using an SPFT test method. Differences are attributed to effects of the solution flow rate on the glass dissolution reate and how the specific surface area of crushed glass is estimated. This comparison indicates the need to standardize the SPFT test procedure.

  • PDF

Measurement of Rainfall Characteristics and Rain-Attenuation at 38 GHz in Worst Months Affected by El Nino Signal in 1998

  • Jang Won-Gyu;Choi Jae-Hoon
    • Journal of electromagnetic engineering and science
    • /
    • v.5 no.4
    • /
    • pp.189-192
    • /
    • 2005
  • The measurement of unique rainfall phenomenon and rain attenuation on 38 GHz terrestrial links at South Korea in 1998 is presented. It was one of the most severe rainfall years at the measured region due to increased EI Nino signal. The rainfall rate exceeded at $0.01\%$ was 97.4 mm/h during a worst month and annual rate was 63.5 mm/h. Experimentally measured results have been compared with some models and found that the rain attenuation by system level was underestimated by the existing prediction models. As it was measured only three months, further study and measurement of rainfall and rain attenuation in this region are needed for stable millimeter-wave system operation at all times.

MEASUREMENT OF THE D-D NEUTRON GENERATION RATE BY PROTON COUNTING

  • Kim, In-Jung;Jung, Nam-Suk;Choi, Hee-Dong
    • Nuclear Engineering and Technology
    • /
    • v.40 no.4
    • /
    • pp.299-304
    • /
    • 2008
  • A detection system was set up to measure the neutron generation rate of a recently developed D-D neutron generator. The system is composed of a Si detector, He-3 detector, and electronics for pulse height analysis. The neutron generation rate was measured by counting protons using the Si detector, and the data was crosschecked by counting neutrons with the He-3 detector. The efficiencies of the Si and He-3 detectors were calibrated independently by using a standard alpha particle source $^{241}Am$ and a bare isotopic neutron source $^{252}Cf$, respectively. The effect of the cross-sectional difference between the D(d,p)T and $D(d,n)^3He$ reactions was evaluated for the case of a thick target. The neutron generation rate was theoretically corrected for the anisotropic emission of protons and neutrons in the D-D reactions. The attenuations of neutron on the path to the He-3 detector by the target assembly and vacuum flange of the neutron generator were considered by the Monte Carlo method using the MCNP 4C2 code. As a result, the neutron generation rate based on the Si detector measurement was determined with a relative uncertainty of ${\pm}5%$, and the two rates measured by both detectors corroborated within 20%.

An Experimental Study on the Performance of Air/Water Direct Contact Air Conditioning System

  • Yoo, Seong-Yeon;Kwon, Hwa-Kil
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.1002-1009
    • /
    • 2004
  • Direct contact air conditioning systems, in which heat and mass are transferred directly between air and water droplets, have many advantages over conventional indirect contact systems. The purpose of this research is to investigate the cooling and heating performances of direct contact air conditioning system for various inlet parameters such as air velocity, air temperature, water flow rate and water temperature. The experimental apparatus comprises a wind tunnel, water spray system, scrubber, demister, heater, refrigerator, flow and temperature controller, and data acquisition system. The inlet and outlet conditions of air and water are measured when the air contacts directly with water droplets as a counter flow in the spray section of the wind tunnel, and the heat and mass transfer rates between air and water are calculated. The droplet size of the water sprays is also measured using a Malvern Particle Analyzer. In the cooling conditions, the outlet air temperature and humidity ratio decrease as the water flow rate increases and as the water temperature, air velocity and temperature decrease. On the contrary, the outlet air temperature and humidity ratio increase in the heating conditions as the water flow rate and temperature increase and as the air velocity decreases.

A study on the injection charateristics of the fuel injection system in a diesel engine (디젤기관 연료분사 시스템의 분사 특성에 관한 연구)

  • 이창식;김정헌
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.14 no.5
    • /
    • pp.54-60
    • /
    • 1992
  • This paper deals with the results of injection characteristics and the influence parameters upon the fuel injection performance of the inline injection system in a diesel engine. In this study, the characteristics of the injection rate, the injection pressure and the injection duration have been investigated by changing the injection parameters. The predicted results and injection performance are compared to the measured data from the injection test system.

  • PDF