• Title/Summary/Keyword: Measure point

Search Result 2,055, Processing Time 0.027 seconds

Work Stress and Affecting Factors of Emergency Medical Technicians (응급구조사의 업무 스트레스와 그 영향 요인)

  • Jo, Hyeon Tae
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.15 no.3
    • /
    • pp.95-103
    • /
    • 2014
  • Objectives: To identify work stress and affecting factors of the emergency medical technicians(EMT) and to provide basic data for work circumstance improvement and emergency medical service and duty efficiency elevation. Methods: The data were collected by questionnaire from 635 emergency medical technicians throughout the whole country from August 5 to September 20 2013 and analyzed by using the SPSS(version 18.0) program. Factors affecting stress were analyzed by Multiple Linear Regression Analysis(${\alpha}=0.05$). Results: Mean level of job stress was markedly high in the spot situation(3.43 point), user awareness(3.31 point), burden related to work(3.21 point), role and conflict as a professional job(3.10 point), unsuitable treatment(2.95 point) but was lowest in specialty demand of knowledge and skill(2.76 point). Conclusions: To diminish work stress, understanding and cooperation of the residents and reduction of burden related to work must be improved. Above all, positive interest of 119 and related organ and duty environment improvement will and effort and continuous measure establishment and support and cooperation of the government are needed.

  • PDF

An Enhanced Function Point Model for Software Size Estimation: Micro-FP Model (소프트웨어 규모산정을 위한 기능점수 개선 Micro-FP 모형의 제안)

  • Ahn, Yeon-S.
    • Journal of the Korea Society of Computer and Information
    • /
    • v.14 no.12
    • /
    • pp.225-232
    • /
    • 2009
  • Function Point Method have been applied to measure software size estimation in industry because it supports to estimate the software's size by user's view not developer's. However, the current function point method has some problems for example complexity's upper limit etc. So, In this paper, an enhanced function point model. Micro FP model, was suggested. Using this model, software effort estimation can be more efficiently because this model has some regression equation. This model specially can be applied to estimate in detail the large application system's size Analysis results show that measured software size by this Micro FP model has the advantage with more correlative between the one of LOC, as of 10 applications operated in an large organization.

Uncertainty Assessment: Relative versus Absolute Point Dose Measurement for Patient Specific Quality Assurance in EBRT

  • Mahmood, Talat;Ibrahim, Mounir;Aqeel, Muhammad
    • Progress in Medical Physics
    • /
    • v.28 no.3
    • /
    • pp.111-121
    • /
    • 2017
  • Verification of dose distribution is an essential part of ensuring the treatment planning system's (TPS) calculated dose will achieve the desired outcome in radiation therapy. Each measurement have uncertainty associated with it. It is desirable to reduce the measurement uncertainty. A best approach is to reduce the uncertainty associated with each step of the process to keep the total uncertainty under acceptable limits. Point dose patient specific quality assurance (QA) is recommended by American Association of Medical Physicists (AAPM) and European Society for Radiotherapy and Oncology (ESTRO) for all the complex radiation therapy treatment techniques. Relative and absolute point dose measurement methods are used to verify the TPS computed dose. Relative and absolute point dose measurement techniques have a number of steps to measure the point dose which includes chamber cross calibration, electrometer reading, chamber calibration coefficient, beam quality correction factor, reference conditions, influences quantities, machine stability, nominal calibration factor (for relative method) and absolute dose calibration of machine. Keeping these parameters in mind, the estimated relative percentage uncertainty associated with the absolute point dose measurement is 2.1% (k=1). On the other hand, the relative percentage uncertainty associated with the relative point dose verification method is estimated to 1.0% (k=1). To compare both point dose measurement methods, 13 head and neck (H&N) IMRT patients were selected. A point dose for each patient was measured with both methods. The average percentage difference between TPS computed dose and measured absolute relative point dose was 1.4% and 1% respectively. The results of this comparative study show that while choosing the relative or absolute point dose measurement technique, both techniques can produce similar results for H&N IMRT treatment plans. There is no statistically significant difference between both point dose verification methods based upon the t-test for comparing two means.

A Study on the Comparison of Methods for the Measurement of Hydrocarbon Dew Point of Natural Gas (천연가스의 탄화수소 이슬점 측정방법 비교 연구)

  • Lee, Kang-Jin;Ha, Young-Cheol;Her, Jae-Young;Woo, Jin-Chun;Kim, Yong-Doo;Bae, Hyun-Kil
    • Korean Chemical Engineering Research
    • /
    • v.53 no.4
    • /
    • pp.496-502
    • /
    • 2015
  • Hydrocarbon dew point(HCDP), a property which is the most generally used for describing natural gas condensation, is a very important parameter of natural gas quality specifications. HCDP is strongly influenced by the concentration of the heavier hydrocarbon components, especially $C_6+$, so, along with compliance with gas quality specifications, build up of procedures for obtaining accurate HCDP is essential for gas transmission company, because hydrocarbon condensation present may cause serious operational and safety problems. This study has been carried out in an attempt to measure HCDP accurately by the automatic hydrocarbon dew point meter under the actual field conditions. Measured HCDP also has been compared with calculated HCDP using the composition determined by gas chromatograph and industry accepted equation of state at multiple pressures, along with the cricondentherm. The test results are 1) the automatic hydrocarbon dew point meter was able to measure stable HCDP continuously 2) the automatic hydrocarbon dew point meter has been performed reference measurement by pure propane with a known dew point from literature, and 3) A meaningful differences was observed when comparing the automatic hydrocarbon dew point meter and gas chromatograph results for synthetic standard gas mixtures and real gas mixtures.

𝔻-SOLUTIONS OF BSDES WITH POISSON JUMPS

  • Hassairi, Imen
    • Journal of the Korean Mathematical Society
    • /
    • v.59 no.6
    • /
    • pp.1083-1101
    • /
    • 2022
  • In this paper, we study backward stochastic differential equations (BSDEs shortly) with jumps that have Lipschitz generator in a general filtration supporting a Brownian motion and an independent Poisson random measure. Under just integrability on the data we show that such equations admit a unique solution which belongs to class 𝔻.

On the Measurement of the Depth and Distance from the Defocused Imagesusing the Regularization Method (비초점화 영상에서 정칙화법을 이용한 깊이 및 거리 계측)

  • 차국찬;김종수
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.32B no.6
    • /
    • pp.886-898
    • /
    • 1995
  • One of the ways to measure the distance in the computer vision is to use the focus and defocus. There are two methods in this way. The first method is caculating the distance from the focused images in a point (MMDFP: the method measuring the distance to the focal plane). The second method is to measure the distance from the difference of the camera parameters, in other words, the apertures of the focal planes, of two images with having the different parameters (MMDCI: the method to measure the distance by comparing two images). The problem of the existing methods in MMDFP is to decide the thresholding vaue on detecting the most optimally focused object in the defocused image. In this case, it could be solved by comparing only the error energy in 3x3 window between two images. In MMDCI, the difficulty is the influence of the deflection effect. Therefor, to minimize its influence, we utilize two differently focused images instead of different aperture images in this paper. At the first, the amount of defocusing between two images is measured through the introduction of regularization and then the distance from the camera to the objects is caculated by the new equation measuring the distance. In the results of simulation, we see the fact to be able to measure the distance from two differently defocused images, and for our approach to be robuster than the method using the different aperture in the noisy image.

  • PDF

Validity of TOEFL, TOEIC and TEPS as a measure of communicative competence (의사소통 능력 측정 도구로서의 공인 영어 표준화 시험 타당도)

  • Lee, Hyun-Oo;Lee, So-Young
    • English Language & Literature Teaching
    • /
    • v.10 no.3
    • /
    • pp.191-210
    • /
    • 2004
  • The scores of TOEFL, TOEIC and TEPS have been increasingly used for many purposes in Korea In particular, these test scores are being used as a measure of the test-takers' overall communicative competence. Nonetheless, few studies have been conducted that investigate the validity of the test scores used for this purpose. As a preliminary step to explore the validity of the test scores, we conducted a small scale study by comparing 30 university students' scores in TOEFL, TOElC and TEPS with their class performances in English conversation and composition courses. The correlations between the test scores and the grade point averages of the courses show that the test scores are much harder to use as a valid measure of test-takers' overall communicative competence than usually thought to be and that the score in TOEFL is, nonetheless, a more reliable measure than the ones in the other tests. Although tins study has a few limitations such as the small number of participants, the homogeneity of the sample as a group, etc, it provides some insight into the use of the three tests for measurement of overall communicative proficiency and suggests need for conducting further validation studies in these areas.

  • PDF

An Interactive Multi-criteria Group Decision Making with the Minimum Distance Measure (최소 거리척도를 이용한 대화형 다기준 그룹 의사결정)

  • Cho, Namwoong;Kim, Jaehee;Kim, Sheung-Kown
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.32 no.1
    • /
    • pp.42-50
    • /
    • 2006
  • The multi-criteria group decision making (MCGDM) problem is to determine the best compromise solution in a set of competing alternatives that are evaluated under conflicting criteria by decision maker (DM)s. In this paper, we propose a mixed-integer programming (MIP) model to solve MCGDM. The existing method based on minimizing a distance measure such as Median Approach can not guarantee the best compromise solution because the element of median point vector is defined with respect to each criteria separately. However, by considering all criteria simultaneously, we generate median point that is better for locating the best compromise solution. We also utilize the concept of spatial dispersion index (SDI) to produce a threshold value, which is used as a guideline to choose either the Utopian Approach or the Median Approach. And we suggest using CBITP (Convex hull of individual maxima Based Interactive Tchebycheff Procedure) to provide DMs with various Pareto-optimal solutions so that DMs have broad range of selection.

Error-compensating Techniques in 3-Point Weighing Method to Measure Unbalance Properties (3점 방식 불평형량 측정법에서의 오차보상 기법)

  • Lee, Sun-Pyo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.11 s.188
    • /
    • pp.42-49
    • /
    • 2006
  • In this paper error-compensating techniques in three-point weighing method to precisely measure unbalance properties such as center of gravity and unbalance moment. In the conventional static methods, 1) fixture-errors, 2) effects of the contact between the fixture and the load scales, and 3) side effect due to the lateral frictional forces acting on the contact points between the fixture and the load scales are the major factors that lead to measurement errors. The proposed error-compensating method perfectly eliminates both the fixture-error and the contact-error simultaneously by manipulating the three measured reaction forces at three different angular locations. Also the friction-error is calibrated by comparing the sum of three reactions with the actual mass of the specimen. A set of measurement is performed using the same measuring system as Lee's, and a comparison of the results from the convectional, Lee's, and the proposed method is provided. The results show that the proposed method effectively compensates the errors listed above.

A Real Time Measurement of Ice Concentration of Ice Slurry in Pipe (배관내 흐르는 아이스슬러리의 실시간 얼음분율 측정)

  • Jung, Hae-Won;Peck, Jong-Hyeon;Kim, Yong-Chan;Kang, Chae-Dong;Hong, Hi-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.8
    • /
    • pp.599-606
    • /
    • 2007
  • An experimental study was performed to measure a ice concentration of ice slurry flowing in a pipe in a real time. In the present paper, we suggested a measuring method by a refractive index and compared it to other methods by a freezing point and a density. To measure the refractive index of the solution, ice particles in the ice slurry should be completely removed and a hydro-cyclone was introduced instead of a mesh. The measuring method through the refractive index coincided with the density method using the real-time solution density within ${\pm}5%$ error range, having the error range less than the other two methods. In the other hand, the measuring method through the density has a good resolution, but the result using the initial density of the solution was different more than 10% error from that using the real-time density. And it has an error range 1.5 times greater than the method through the refractive index.