• 제목/요약/키워드: Measure of evaluation

Search Result 3,397, Processing Time 0.028 seconds

Evaluation of Effective Dose in Dental Radiography (치과 방사선 검사에서 유효선량 평가)

  • Han, Su-Chul;Lee, Bo-Ram;Shin, Gwi-Soon;Choi, Jong-Hak;Park, Hyok;Park, Chang-Seo;Chang, Kye-Yong;Kim, Bo-Ram;Kim, You-Hyun
    • Journal of radiological science and technology
    • /
    • v.34 no.1
    • /
    • pp.27-33
    • /
    • 2011
  • Along with the developments of science technology, up-to-date medical radiation equipments are introduced. Those equipments has brought many progresses in diagnosing patients not only in the quantitative aspects but in the qualitative ones. Especially, in the case of dental radiography, patients can be exposed more than CT, cone beam computed tomography (CBCT). In this study, we used human phantom and TLD-100H to measure the organ dose in each dental radiography and computed the effective dose according to ICRP (International Committee for Radioactivity Prevention) 60, 103. We measured the effective dose to be 5.1 and $29.5{\mu}Sv$ in the panoramic radiography and 11.2 and $14.4{\mu}Sv$ in the cephalometric radiography respectively. We also executed the CBCT and CT test on the maxillaries and the mandibles and found the amounts of effective dose were 53.7, 209.6, 129, and $391.5{\mu}Sv$ respectively in the CBCT and $93.3{\mu}$, 139.5, 282.7 and $489.7{\mu}Sv$ in the CT test. Consequently, it was shown that the effective dose in the CBCT test was lower than one in the CT test, but was higher in both panoramic and cephalometric radiography.

Evaluation of Sustainability for Olive Flounder Production by the Systems Ecology I. EMERGY Analysis of Olive Flounder Production (시스템 생태학적 접근법에 의한 넙치생산의 지속성 평가 I. 넙치생산에 대한 EMERGY 분석)

  • KIM Nam Kook;SON Ji Ho;KIM Jin Lee;LEE Suk Mo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.34 no.3
    • /
    • pp.218-224
    • /
    • 2001
  • Olive flounder is one of the most important aquaculture species in Korea. Interest in the aquaculture of olive flounder has increased recently because of its good growth characteristics and high market price, However, the productivity of olive flounder aquaculture depends on economic inputs such as fuels, facilities, and labor, In this study, EMERGY concepts was used to compare the environment and economy of two olive flounder production methods, fishing fisheries and aquaculture, and to evaluate the sustainability of olive flounder production, EMERGY spelled with an 'm' is a universal measure of real wealth of the work of nature and society made on a common basis. Calculations of EMERGY production and storage provide a basis for making choices about environment and economy following. the general public policy to maximize real wealth, production and use. EMERGY flows from environment were $94.13\%$ for olive flounder fishing fisheries, and $2.20\%$ for aquaculture. EMERGY yield ratio, environmental loading ratio and sustainability index were 17.05, 1.02 and 274 for fishing fisheries and 0.06, 44.41 and 0.023 for aquaculture, respectively. These ratios indicate that the fishing fisheries will yield more net EMERGY, while the aquaculture requires a lower investment of EMERGY.

  • PDF

The Study of Radiation Exposed dose According to 131I Radiation Isotope Therapy (131I 방사성 동위원소 치료에 따른 피폭 선량 연구)

  • Chang, Boseok;Yu, Seung-Man
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.653-659
    • /
    • 2019
  • The purpose of this study is to measure the (air dose rate of radiation dose) the discharged patient who was administrated high dose $^{131}I$ treatment, and to predict exposure radiation dose in public person. The dosimetric evaluation was performed according to the distance and angle using three copper rings in 30 patients who were treated with over 200mCi high dose Iodine therapy. The two observer were measured using a GM surverymeter with 8 point azimuth angle and three difference distance 50, 100, 150cm for precise radion dose measurement. We set up three predictive simulations to calculate the exposure dose based on this data. The most highest radiation dose rate was showed measuring angle $0^{\circ}$ at the height of 1m. The each distance average dose rate was used the azimuth angle average value of radiation dose rate. The maximum values of the external radiation dose rate depending on the distance were $214{\pm}16.5$, $59{\pm}9.1$ and $38{\pm}5.8{\mu}Sv/h$ at 50, 100, 150cm, respectively. If high dose Iodine treatment patient moves 5 hours using public transportation, an unspecified person in a side seat at 50cm is exposed 1.14 mSv radiation dose. A person who cares for 4days at a distance of 1 meter from a patient wearing a urine bag receives a maximum radiation dose of 6.5mSv. The maximum dose of radiation that a guardian can receive is 1.08mSv at a distance of 1.5m for 7days. The annual radiation dose limit is exceeded in a short time when applied the our developed radiation dose predictive modeling on the general public person who was around the patients with Iodine therapy. This study can be helpful in suggesting a reasonable guideline of the general public person protection system after discharge of high dose Iodine administered patients.

Evaluation of sleep quality and stress response in patients requiring dental prosthetic treatment (치과보철치료를 요하는 환자에서의 수면질과 스트레스 반응 평가)

  • Jeon, Hye-Mi;Jung, Kyoung-Hwa;Choi, Na-Rae;Song, Jae-Min;Lee, So-Hyoun;Kim, So-Yeun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.2
    • /
    • pp.181-189
    • /
    • 2021
  • Purpose: The purpose of this study is to investigate the stress response and sleep state of the new patients who visit the hospital for prosthodontic treatment due to tooth loss to make reference to further treatment direction. Materials and methods: Examinations, consultations, and surveys were conducted on 236 patients (94 males, 142 females, and 24-86 years old), who newly registered at the department of prosthodontics at Pusan national university hospital, for 2 years from 2018. The number of remaining teeth, edentulous arch, possibility of mastication, and future prosthetic treatment directions were recorded. The visual analogue scale (VAS), stress response inventory (SRI) and Insomnia severity index (ISI) were used as tools to measure patient's subjective discomfort, stress response, and sleep status. Results: Among the entire prosthodontic patient group, the average value of 'fatigue' was significantly higher among the 7 items of SRI, and the value of 'aggression' was significantly lower (P<.001). There are a significant difference between the edentulous and full dentition in the oral discomfort value measured by VAS (P=.004). In cases where less than 20 teeth remain, mastication is impossible, and patients who are planning treatment with removable prostheses, VAS value and 'depression' and 'fatigue' values in SRI were higher than those in the reverse case (P<.05). The patients showed severe level in VAS value have high value of 'tension', 'somatization', 'depression', 'fatigue'and 'frustration'in SRI than non-serious patients (P<.05). Clinical insomnia occurred in 11.4% of all patients, and women had significantly lower sleep quality than men (P=.044). Patients with insomnia showed significantly higher scores on the VAS value and all 7 SRI items than those of normal sleepers (P<.05). Conclusion: The new prosthetics had high 'fatigue' value among the 7 items of SRI. The oral condition, number of residual teeth and mastication function and clinical insomnia affected oral discomfort and the stress response.

Comparison and evaluation of treatment plans using Abdominal compression and Continuous Positive Air Pressure for lung cancer SABR (폐암의 SABR(Stereotactic Ablative Radiotherapy)시 복부압박(Abdominal compression)과 CPAP(Continuous Positive Air Pressure)를 이용한 치료계획의 비교 및 평가)

  • Kim, Dae Ho;Son, Sang Jun;Mun, Jun Ki;Park, Jang Pil;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.35-46
    • /
    • 2021
  • Purpose : By comparing and analyzing treatment plans using abdominal compression and The Continuous Positive Air Pressure(CPAP) during SABR of lung cancer, we try to contribute to the improvement of radiotherapy effect. Materials & Methods : In two of the lung SABR patients(A, B patient), we developed a SABR plan using abdominal compression device(the Body Pro-Lok, BPL) and CPAP and analyze the treatment plan through homogeneity, conformity and the parameters proposed in RTOG 0813. Furthermore, for each phase, the X, Y, and Z axis movements centered on PTV are analyzed in all 4D CTs and compared by obtaining the volume and average dose of PTV and OAR. Four cone beam computed tomography(CBCT) were used to measure the directions from the center of the PTV to the intrathoracic contacts in three directions out of 0°, 90°, 180° and 270°, and compare the differences from the average distance values in each direction. Result : Both treatment plans obtained using BPL and CPAP followed recommendations from RTOG, and there was no significant difference in homogeneity and conformity. The X-axis, Y-axis, and Z-axis movements centered on PTV in patient A were 0.49 cm, 0.37 cm, 1.66 cm with BPL and 0.16 cm, 0.12 cm, and 0.19 cm with CPAP, in patient B were 0.22 cm, 0.18 cm, 1.03 cm with BPL and 0.14 cm, 0.11 cm, and 0.4 cm with CPAP. In A patient, when using CPAP compared to BPL, ITV decreased by 46.27% and left lung volume increased by 41.94%, and average dose decreased by 52.81% in the heart. In B patient, volume increased by 106.89% in the left lung and 87.32% in the right lung, with an average dose decreased by 44.30% in the stomach. The maximum difference of A patient between the straight distance value and the mean distance value in each direction was 0.05 cm in the a-direction, 0.05 cm in the b-direction, and 0.41 cm in the c-direction. In B patient, there was a difference of 0.19 cm in the d-direction, 0.49 cm in the e-direction, and 0.06 cm in the f-direction. Conclusion : We confirm that increased lung volume with CPAP can reduce doses of OAR near the target more effectively than with BPL, and also contribute more effectively to restriction of tumor movement with respiration. It is considered that radiation therapy effects can be improved through the application of various sites of CPAP and the combination with CPAP and other treatment machines.

IMRT and IMRS Checking the Dose Distribution in the Small Field Evaluation of Measurement by Changes in SAD (IMRT 및 IMRS에서 Small Field의 선량분포 확인시 SAD 변화에 따른 측정의 유용성 평가)

  • Ko, Seung-Young;Kim, Sung-Joon;Park, Gir-Yong;Son, Mi-Suk;Lee, Nam-Ki;Kim, Jin-Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.33-39
    • /
    • 2010
  • Purpose: It is very important to confirm conformance of dose distribution that is formed with treatment planning from IMRS or IMRT. It has been a problem dropped accuracy and conformance when the field size is getting smaller because of character of the 2D ion chamber. Verification of MatriXX Phantom dose distribution with a change in the SAD. Dose distribution measurement and analysis to improve the accuracy and should be useful to evaluate the award. Materials and Methods: A use of Novalis linear accelerator 6 MV photon beams. In general, IMRS were 25 patients with small field size. The selected patients were divided into three groups on the basis of the field size. SAD was changed from 80 to 130 cm and field size to determine the dose distribution to the change, each dose was measured using MatriXX Phantom. Analysis of measured values obtained from the program for each patient through the treatment planning system comparison and analysis of the dose distribution and gamma values were expressed. Result: SAD 80, 100, and 120 cm in size in the gamma value to the investigation of patients less than $3\;cm^2$ average 0.939, 0.969, and 0.979, respectively. Patients with more than $5\;cm^2$ 0.962, 0.983, and 0.988, respectively. $5\;cm^2$ or more patients 0.982, 0.990, and 0.992, respectively. Conclusion: The error rate of less than $3\;cm^2$ field size is increased rapidly. If the field size is increased, resolution is increased by 2D ion chambers. It has been approved that it can be credible if it is around $3\;cm^2$ when measuring dose distribution using MatriXX. Adjusting geometric field size by changing SAD is likely to be very useful when you measure dose distribution using MatriXX.

  • PDF

A Hybrid Forecasting Framework based on Case-based Reasoning and Artificial Neural Network (사례기반 추론기법과 인공신경망을 이용한 서비스 수요예측 프레임워크)

  • Hwang, Yousub
    • Journal of Intelligence and Information Systems
    • /
    • v.18 no.4
    • /
    • pp.43-57
    • /
    • 2012
  • To enhance the competitive advantage in a constantly changing business environment, an enterprise management must make the right decision in many business activities based on both internal and external information. Thus, providing accurate information plays a prominent role in management's decision making. Intuitively, historical data can provide a feasible estimate through the forecasting models. Therefore, if the service department can estimate the service quantity for the next period, the service department can then effectively control the inventory of service related resources such as human, parts, and other facilities. In addition, the production department can make load map for improving its product quality. Therefore, obtaining an accurate service forecast most likely appears to be critical to manufacturing companies. Numerous investigations addressing this problem have generally employed statistical methods, such as regression or autoregressive and moving average simulation. However, these methods are only efficient for data with are seasonal or cyclical. If the data are influenced by the special characteristics of product, they are not feasible. In our research, we propose a forecasting framework that predicts service demand of manufacturing organization by combining Case-based reasoning (CBR) and leveraging an unsupervised artificial neural network based clustering analysis (i.e., Self-Organizing Maps; SOM). We believe that this is one of the first attempts at applying unsupervised artificial neural network-based machine-learning techniques in the service forecasting domain. Our proposed approach has several appealing features : (1) We applied CBR and SOM in a new forecasting domain such as service demand forecasting. (2) We proposed our combined approach between CBR and SOM in order to overcome limitations of traditional statistical forecasting methods and We have developed a service forecasting tool based on the proposed approach using an unsupervised artificial neural network and Case-based reasoning. In this research, we conducted an empirical study on a real digital TV manufacturer (i.e., Company A). In addition, we have empirically evaluated the proposed approach and tool using real sales and service related data from digital TV manufacturer. In our empirical experiments, we intend to explore the performance of our proposed service forecasting framework when compared to the performances predicted by other two service forecasting methods; one is traditional CBR based forecasting model and the other is the existing service forecasting model used by Company A. We ran each service forecasting 144 times; each time, input data were randomly sampled for each service forecasting framework. To evaluate accuracy of forecasting results, we used Mean Absolute Percentage Error (MAPE) as primary performance measure in our experiments. We conducted one-way ANOVA test with the 144 measurements of MAPE for three different service forecasting approaches. For example, the F-ratio of MAPE for three different service forecasting approaches is 67.25 and the p-value is 0.000. This means that the difference between the MAPE of the three different service forecasting approaches is significant at the level of 0.000. Since there is a significant difference among the different service forecasting approaches, we conducted Tukey's HSD post hoc test to determine exactly which means of MAPE are significantly different from which other ones. In terms of MAPE, Tukey's HSD post hoc test grouped the three different service forecasting approaches into three different subsets in the following order: our proposed approach > traditional CBR-based service forecasting approach > the existing forecasting approach used by Company A. Consequently, our empirical experiments show that our proposed approach outperformed the traditional CBR based forecasting model and the existing service forecasting model used by Company A. The rest of this paper is organized as follows. Section 2 provides some research background information such as summary of CBR and SOM. Section 3 presents a hybrid service forecasting framework based on Case-based Reasoning and Self-Organizing Maps, while the empirical evaluation results are summarized in Section 4. Conclusion and future research directions are finally discussed in Section 5.

Comparison of Noise Power Spectrum Methodologies in Measurements by Using Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료시 전자포털영상장치를 이용한 잡음전력스펙트럼 방법론 측정비교)

  • Son, Soon-Yong;Choi, Kwan-Woo;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Kim, Ki-Won;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.99-105
    • /
    • 2016
  • The noise power spectrum (NPS) is one of the most general methods for measuring the noise amplitude and the quality of an image acquired from a uniform radiation field. The purpose of this study was to compare different NPS methodologies by using megavoltage X-ray energies. The NPS evaluation methods in diagnostic radiation were applied to therapy using the International Electro-technical Commission standard (IEC 62220-1). Various radiation therapy (RT) devices such as TrueBeam$^{TM}$(Varian), BEAMVIEW$^{PLUS}$(Siemens), iViewGT(Elekta) and Clinac$^R$ iX (Varian) were used. In order to measure the region of interest (ROI) of the NPS, we used the following four factors: the overlapping impact, the non-overlapping impact, the flatness and penumbra. As for NPS results, iViewGT(Elekta) had the higher amplitude of noise, compared to BEAMVIEW$^{PLUS}$ (Siemens), TrueBeam$^{TM}$(Varian) flattening filter, Clinac$^{R}$iXaS1000(Varian) and TrueBeam$^{TM}$(Varian) flattening filter free. The present study revealed that various factors could be employed to produce megavoltage imaging (MVI) of the NPS and as a baseline standard for NPS methodologies control in MVI.

A Study on the Evaluation of Distribution Stability of Refrigerated Rice Cake Using Natural Antibiotics (천연항균제를 사용한 냉장떡류의 유통 안정성 평가연구)

  • Yoo, Seung Jin;Chin, Jong-eon;Oh, Sung Hoon;Ryu, Min Jung;Hwang, Kwontack
    • Journal of Chitin and Chitosan
    • /
    • v.23 no.4
    • /
    • pp.244-255
    • /
    • 2018
  • Natural extract in liquid phase was adjusted to 0, 0.25, 0.5, 1, 2, and 4% concentration to check microbial changes and to measure 4, 8, $12^{\circ}C$ for refrigeration temperature. In the case of grapefruit extract, the microbial safety was maintained at all the concentrations at $4^{\circ}C$ storage, but the antimicrobial activity was maintained at $12^{\circ}C$ storage and at $8^{\circ}C$ and 21 days storage. In the case of grape seed extract, only the 4% of the culture at $8^{\circ}C$ satisfied the requirement of safety of food distribution for the last 21 days, and the safety criterion was satisfied only at 4% concentration at $12^{\circ}C$ for 18 days. Complex Scutellaria baicalensis extract showed the total number of microbial cells treated by concentration. It was confirmed that microbial flow safety was maintained at low temperature ($4^{\circ}C$). However, at $8^{\circ}C$ and $12^{\circ}C$, Exceeded the distribution limit. When polylysine was applied to brown rice cake, it showed activity in all groups except $4^{\circ}C$, but these properties were not observed at $8^{\circ}C$ and $12^{\circ}C$. At a concentration of 0.5% or more of chitosan, the growth of the microorganism is suppressed by the 21st day very stably, and a similar tendency is observed at 8 and $12^{\circ}C$, so that it may be an antimicrobial material that inhibits microorganisms. At the first day, the distribution standards for general bacterial counts were exceeded.Ethyl-pyruvate showed that microorganism safety was maintained at $4^{\circ}C$ and 1% concentration, and food safety was stable even at 2 or 4%. Glycine showed very good and stable distribution stability at $4^{\circ}C$. However, at $8^{\circ}C$ and $12^{\circ}C$, the shelf life of 14 days could not be maintained as with the addition of other antimicrobial active substances.

Relationship between Incidence of Endometritis and Metabolic Status during Peri- and Postpartum Periods in Dairy Cows (젖소의 자궁내막염 발생과 분만 전·후 대사 상태와의 상관관계)

  • Jeong, Jae-Kwan;Choi, In-Soo;Kang, Hyun-Gu;Jung, Young-Hun;Hur, Tai-Young;Kim, Ill-Hwa
    • Journal of Veterinary Clinics
    • /
    • v.32 no.5
    • /
    • pp.426-432
    • /
    • 2015
  • This study compared blood metabolites during peri- and postpartum periods among cows with clinical or subclinical endometritis and cows without endometritis. Blood samples from 207 Holstein dairy cows were collected at 4 weeks prepartum, just after calving, and at 1, 2, 4, and 6 weeks postpartum to measure serum concentrations of calcium, magnesium, non-esterified fatty acids (NEFAs), total cholesterol, albumin, urea nitrogen, ${\beta}$-hydroxybutyrate (BHBA), aspartate aminotransferase (AST), ${\gamma}$-glutamyltransferase, glucose, and phosphorus. Clinical endometritis was diagnosed by the observation of vaginal discharge (> 50% pus) and subclinical endometritis was diagnosed by the evaluation of uterine cytology (> 18% neutrophils) at 4 weeks postpartum. Cows were divided into three groups based on the presence or absence of clinical or subclinical endometritis: the control group (n = 104), the clinical endometritis group (n = 66), and the subclinical endometritis group (n = 37). Calcium and magnesium concentrations were lower in the clinical endometritis group than in the control and subclinical endometritis groups throughout the study period (p < 0.05 to 0.0001), whereas the NEFAs concentration was higher in the clinical endometritis group than in the control group throughout the study period (p < 0.01). The total cholesterol concentration was lower in the clinical endometritis group than in the control and subclinical endometritis groups throughout the pre- and postpartum periods (p < 0.05 to 0.001). The albumin concentration was lower in the clinical endometritis group than in the control and subclinical endometritis groups during the postpartum period (p < 0.05 to 0.001). The urea nitrogen concentration was lower in the clinical endometritis group than in the control and subclinical endometritis groups at 4 and 6 weeks postpartum (p < 0.01). At 1 week postpartum, the BHBA concentration was higher in the clinical endometritis group than in the control group (p < 0.05), whereas the AST concentration was higher in the clinical endometritis and subclinical endometritis groups than in the control group (p < 0.05). In conclusion, lower serum concentrations of calcium, magnesium, total cholesterol, albumin, and urea nitrogen, but higher concentrations of NEFAs, BHBA, and AST during the postpartum period were associated with the incidence of clinical endometritis, indicating the importance of balanced nutrition during the transition period.