高溫環境이 反芻家畜의 체온 및 혈장 Cortisol 농도에 미치는 影響 (Effect of Hot Environment on the Body Temperature and Plasma Cortisol Concentration in Ruminant)

  • 정태영;양영직;이상락;윤희섭
    • 한국축산시설환경학회지
    • /
    • 제1권1호
    • /
    • pp.39-45
    • /
    • 1995
  • Temperatures of blood and skin, respiratory rate and plasma cortisol concentration in sheep at a warm (average ambient temperature of $15.3^{\circ}C$) and a hot (average ambient temperature of $27.0^{\circ}C$ environment were measured to investigate the effect of hot environment on the physiological responses in ruminant. Temperatures of core, mean skin and mean body in sheep were tended to increase at day time and to decrease at night time at both warm and hot environment, while 24-hr average for those temperatures were significantly higher at hot environment than at warm environment (P<0.05). The calculated body heat content was higher in sheep at hot environment than at warm environment (P<0.05). Respiratory rate and plasma cortisol concentration had no significant differences between warm and hot environment, suggesting that sheep were not stress by the hot environment in this experiment. It is, therefore, suggested that sheep were well adopted to hot environment by increasing body heat content against heat stress.

  • PDF

더운 환경에서 산업용 각반 착용 시 인체생리반응 (Physiological Responses of Wearing Industrial Gaiters in a Hot Environment)

  • 최정화;박준회
    • 한국의류학회지
    • /
    • 제32권7호
    • /
    • pp.1129-1136
    • /
    • 2008
  • The gaiter is one of the personal protective equipments worn in various industrial sites. This study was performed on humans to investigate the physiological strain of wearing gaiters and to compare control gaiters that are currently on the market and new gaiters that are developed for alleviating heat stress. Experiments were conducted in a climatic chamber of WBGT $30.0\pm0.7^{\circ}C$ under five differed experimental conditions: None, Control A, Control B, New A, New B. The results were as follows. The temperature inside gaiters was significantly lower in both New A and New B than in both Control A and Control B and the difference between news and controls was 1$^{\circ}C$ (p<.01). The humidity inside gaiters in both New A and New B were higher than that in Control A, and lower than that in Control B (p<.01). The outermost surface temperature of the gaiter was the lowest in None and it increased in the following order: New B < New A < Control A < Control B. Mean skin temperature was higher by 0.14$^{\circ}C$ in wearing gaiters than in no gaiters. Skin temperatures in lower body were lower in Control than in New and skin temperature in upper body were higher in Control than in New (p<.01). Local sweat rate, total weight loss and subjective sensations did not show a significant difference according to the gaiters. It was concluded that wearing gaiters affected distribution of skin temperature and local sweat rate.

발가락 양말 소재별 인체생리반응 및 착용감 (Physiological Responses and Wearing Sensation of Different Toes Socks Materials)

  • 이지은;권영아
    • 한국의류학회지
    • /
    • 제32권7호
    • /
    • pp.1056-1064
    • /
    • 2008
  • Toes socks are used widely for the health of feet. However, discomfort is one of the major complains from toes socks users. The purpose of this study is to determine the effect of functional fibers on the physiological response and wearing sensation of toes socks. For experiment, two different toes socks with cotton/warm fiber(WS) and cotton/chitosan fiber(CS) were knitted automatically by a computer controlled flat knitting machine. The control toes socks with cotton/nylon/polyurethan(TS) were prepared to compare the properties. Experiments were conducted in a climate room of $16\pm2^{\circ}C$, $50\pm5%$ R.H. The results of this study were as follows. The change of heart rate, pulse rate, and mean skin temperature showed no difference among three different socks. However, skin temperature of TS was evaluated higher than that of WS and CS. After exercise wearing WS both instep temperature and sole temperature of women tend to higher compared to men. Wet sensation and overall comfort sensation of toes socks were significantly influenced by different fiber contents. Subjects evaluated WS and CS more comfortable than TS.

한랭환경하에서 운동발한시 인체의 체온조절반응에 대한 내의소재의 생리학적 의의 (Physiological Effects of Different Underwear Materials Thermoregulatory Response during Exercise with Sweating at Cold Environments)

  • 권오경;김태규;손부헌;박승한
    • 한국의류산업학회지
    • /
    • 제1권1호
    • /
    • pp.43-49
    • /
    • 1999
  • This study conducted 4 different kinds of underwear materials, which were A (Cotton 100%), B (Wool 100%), C (Cotton/Wool, 50/50%) and D (Acrylic/Cotton, 50/50%) and were done in a climate chamber under cold ambient $10{\pm}1^{\circ}C$, $40{\pm}5%RH$ by 6 male subjects who were in good health. Physiological parameters such as rectal and local skin temperature(forehead, forearm, hand, trunk, thigh, leg, foot, back and chest), heart rate, body weight loss, clothing microclimate, blood lactic acid concentration, and wearing sensation were measured. Started with a 15-min rest period, 15-min of exercise 1 (the condition of 4.5 mile/hr walking speed equivalent to with 8.5 Kcal energy consumption on the treadmill) period, 15-min rest period, exercise 2 (after 3minutes warming-up at 3.0. 3.7, 4.5. 5.2. 6.0, 6.7 mile/hr) until exhaustion period, and final 15-min of recovery period were performed. The results were as follows: The lowest mean skin temperature was acrylic/cotton in order of wool > cotton/wool > cotton > acrylic/cotton (F=13. 79. p<0.00l). Most of all skin temperature by parts of body had turned out in sequence of temperature wool > cotton/wool > acrylic/cotton > cotton. Fore arm part showed highest temperature about $32.43^{\circ}C$ on wool and had a tendency approximately $1.8^{\circ}C$ higher than cotton which had the lowest temperature, and had the biggest difference among garments in terms of skin temperature. The back temperature within clothing showed about $2^{\circ}C$ higher than the chest temperature within clothing. but the back humidity within clothing showed about 4~12% higher than the chest humidity within clothing. Body weight loss by each garment was this sequence; cotton > acrylic/cotton > wool > cotton/wool.

  • PDF

비닐하우스 내에서의 발수발유가공 부직포와 복합가공 부직포로 만든 농약 방호복의 착용성능 (Wear Performance of Pesticide Protective Clothing in Vinyl Plastic Hothouse made with Water-Oil Repellent and Dual Functional Finished Nonwoven Fabrics)

  • 최종명;조정숙;조길수
    • 한국의류학회지
    • /
    • 제20권2호
    • /
    • pp.350-361
    • /
    • 1996
  • The objectives of this study mere 1) to investigate whether the different nonwoven fabric types influenced on the objective and subjective wear performances of the experimental pesticide protective pants, 2) to detect whether the different finishes treated to the nonwoven fabrics influenced on the objective and subjective wear performances of the experimental pants, and 3) to detect the relationships between objective wear performances and subjective wear sensation. Three types of nonwoven fabrics (T (Tyvek$\textregistered$), 5 (Sontara$\textregistered$) and K (Kimlon$\textregistered$)) were used as test specimens. By pad-dry.cure method, each of the specimen was treated with fluorocarbon compound for water-oil repellent finish (Tw, Sw, Kw). And each of specimen was treated with organic silicon quarternary ammonium salts and then treated with fluorocabon compound for dual functional finish (76, 50, Kd). Using the three water-oil repellent finished fabrics and the three dual functional finished fabrics, six experimental protective pants (Cl (Tw), C2 (Sw), C3 (Kw), C4 (76), C5 (56), C6 (Kd)) were made according to the same pattern suggested by the Rual Guidance Office. The wear trials of experimental pesticide protective pants were performed in a conditioned vinyl plastic hothouse ($30\pm1^{\circ}C$, $70\pm5%$R.H., 0.25m/sec air velocity). The measurements of skin temperature, microclimate temperature and humidity on the subjects were obtained by the themohygromenter. The subjective wear sensations were measured using previously developed thermal, humidity and overall comfort scales. The results obtained from this study were as follows: 1) There were siginificant differences among nonwoven fabric types on the objective and subjective wear performances, therefore, the skin temperature, microclimate temperature and humidity of subjects who wore the experimental pants made with Sontara were siginificantly lower than those who wore the others. And, the experimental pants made with Sontara were assessed as more comfortable than the others in terms of the subjective thermal, humidity and overall wear sensations. 2) There were no significant differences between two finish types on the objective and subjective wear Performances. 3) The microclimate humidity on the thigh was highly correlated with the overall subjective comfort sensations and the next highly correlated one was the mean skin temperature. That is, the higher the microclimate humidity and the mean skin temperature, the higher the overall subjective comfort sensation ratings which mean the overall subjective sensation was very uncomfortable.

  • PDF

탄성 압박 밴드를 이용한 인체 부위별 의복압 가압 수준에 관한 연구 (Determination of the Garment Pressure Level Using the Elastic Bands by Human Body Parts)

  • 백윤정;최정화
    • 한국의류학회지
    • /
    • 제32권10호
    • /
    • pp.1651-1658
    • /
    • 2008
  • This study was to decided the proper garment pressure level on the human body parts. Six volunteers (female: 30-40years) put on the same types of bands, a brief, and a non-woven gown. Garment pressure was measured in regular order with the elastic band on the human body parts such as the upper arm, the waist, the thigh, and the calf. At the same time, physiological responses such as the skin blood flow rate on 2 fingers, 7 different skin temperatures, rectal temperature, heat rates, and subjective responses about the pressure sensation, thermal sensation, and humidity sensation were measured and inquired. The results were as follows; 1. The thicker subcutaneous fat thickness, the higher the mean garment pressure on pressurizing the upper arm(p<.001). Also the thicker subcutaneous fat thickness. the thicker the upper arm circumference. 2. Heart rates increased pressured the upper arm and decreased pressured the waist, the thigh, and the calf. The higher the garment pressure, the higher heart rates on all body parts were pressured. Especially lean subjects showed higher physiological load than others. 3. On pressurizing the upper arm, heart rates, rectal temperature, and mean skin temperature were higher than without pressured state and pressured other body parts.4. The proper garment pressure levels were decided 30gf/$cm^2$ for fat people, 20gf/$cm^2$ for others on the upper arms and 24gf/$cm^2$ on the calf.

박스형 이중외피와 커튼월의 냉방기 열적성능에 관한 비교실험 연구 (A Comparative Experimental Study on Thermal Performance of Box-typed Double Skin and Curtain Wall in Cooling Period)

  • 박창영;이건호;윤용상;최창호
    • 한국태양에너지학회 논문집
    • /
    • 제27권2호
    • /
    • pp.111-119
    • /
    • 2007
  • The annual mean temperature of South Korea has risen by $1.3^{\circ}C$ for last 100 years by urbanization and industrialization. Especially, the frequency of unusual hot weather in summer increases for a long time and the frequency of unusual cold weather in winter clearly decreases. In recently, The considerable portion of curtain wall system is appled to building skin in domestic. As related to this, the Korea Institute of Construction Technology devised the box typed double skin facade(It is occasionally called as FDFS : Functional Double Facade System) as an alternative that reflects the distinctive local climate and saves cooling energy. Two mock-ups($49m^*4.9m$) applied to single skin(curtain wall) and double skin each were monitored under the outdoor condition. Therefore, the characteristics of natural ventilation and cooling energy consumption of each window had been analyzed in real time. The results of this study are summarized as follow, Analysis of the experiment on an air conditioner: the indoor temperature of the chamber with FDFS is lower than that of the chamber with single skin facades by $3{\sim}6$ degrees(C). A temperature variation of about $1{\sim}2$ degrees between the 0.2m and 1.7m height of the mock-up occurs in FDFS, while that of about maximum 7 degrees occurs in single skin facade at noon with abundant intensity of solar accident. Also, 67 percent of energy consumption for air conditioning has been saved.

적외선 라디오미터 관측 자료를 활용한 해양 피층 수온 산출 (Retrieval of Oceanic Skin Sea Surface Temperature using Infrared Sea Surface Temperature Autonomous Radiometer (ISAR) Radiance Measurements)

  • 김희영;박경애
    • 한국지구과학회지
    • /
    • 제41권6호
    • /
    • pp.617-629
    • /
    • 2020
  • 기후변화와 지구환경변화에 중요한 역할을 하고 있는 해수면온도는 인공위성 적외선 센서가 관측하는 피층 수온과 측기들이 관측하는 표층 수온으로 나누어질 수 있다. 국외 여러 기관에서 보급되고 있는 해수면온도 관측 자료들은 각각 서로 다른 깊이의 수온을 나타내고 있어서 해양 피층과 표층 수온 사이의 관계를 이해하는 것은 매우 중요하다. 본 연구에서는 적외선 라디오미터를 해양조사선에 장착하기 위한 시스템을 설계하고 부착하고 운용하여 국내에서 처음으로 해양 피층 수온을 산출할 수 있는 관측 환경을 구축하였다. 선박 관측 전에 실험실에서 라디오미터 기기의 검보정을 실시하여 보정 계수를 산출하였다. 관측된 해수면에서 방출된 복사에너지와 하늘 복사에너지를 피층 수온으로 산출하는 일련의 과정을 적용하였다. 산출된 피층 해수면온도를 현장 관측 표층 수온자료와 비교하여 표층과 피층 수온 차이를 정량적으로 조사하고자 하였으며, Himawari-8 정지궤도 위성 해수면온도 자료와의 비교를 통해 해양 상층 연직구조의 특성을 이해하고자 하였다. 2020년 4월 21일부터 5월 6일까지 남해안의 장목항과 동해 남부를 관측한 해양 피층 수온은 전체적으로 표층 수온과 0.76℃ 정도의 차이를 보였다. 또한 이 두 수온 차이의 평균제곱근오차는 약 0.6℃에서 0.9℃까지의 일간변화를 가지고 있었으며, 하루 중 1-3시에 0.83-0.89℃로 가장 크게 나타났으며, 15시에 0.59℃로 최소의 차이를 가지고 있었다. 또한 편차도 0.47-0.75℃의 일간변화를 나타내었다. 해양 피층 관측 수온과 위성 해수면 온도 간 차이는 약 0.74℃의 평균제곱근오차, 0.37℃의 편차를 나타냈다. 본 연구의 분석을 통해 관측 수심에 따른 피층-표층 수온의 차이를 확인할 수 있었으며, 피층-표층 수온 차의 계절적 변화를 정량적으로 이해하고 또 변동 요인과의 관련성을 연구하기 위하여 연구조사선을 이용한 추가적인 연안 및 대양 관측이 지속적으로 진행되어야 함을 시사한다.

스포츠웨어의 슬릿 벤틸레이션 시스템이 인체 생리반응에 미치는 효과 (Effect of Slit Ventilation System in Sportswear on Physiological Responses)

  • 연수민;김희은
    • 한국의류산업학회지
    • /
    • 제7권1호
    • /
    • pp.75-80
    • /
    • 2005
  • The purpose of this study was to investigate the effects of silt ventilation system on physiological responses. We measured rectal temperature, local skin temperature, clothing microclimate, blood pressure, heart rate, energy metabolism, body weight loss and subjective sensation during 70 minute, 50 min exercise period and 20 min rest period. The five women subjects randomly wore sportswear without slit ventilation system(NS sportswear) and sportswear with slit ventilation system(S sportswear) under the environmental condition of $25^{\circ}C$, 50%RH. The results of this study are as follows; Rectal temperature, mean skin temperature, clothing microclimate, blood pressure, heart rate, energy metabolism and body weight loss were significantly lower level in 'S sportswear'. In 'S sportswear', subjects replied less hot, less uncomfortable and less wet. Slit ventilation system can be used for bellow effect which is meaningful device of convection during exercise. We could find out that 'S sportswear' has advantage in physiological function.

체형별 발한 반응에 관한 연구 (A study of sweating reaction on somato type)

  • 심부자
    • 대한인간공학회:학술대회논문집
    • /
    • 대한인간공학회 1997년도 추계학술대회논문집
    • /
    • pp.72-96
    • /
    • 1997
  • To investigate the difference of sweating reaction on somato types. We measured total sweat rate, locl sweat rate, skin temperature, physiological reactions and psyschological reactions at $25{\pm}1^{\circ}C$ and $25{\pm}1^{\circ}C$ under laboratory conditions. Nine healthy adult females were divided into three somato types (slender(3), normal(3) and obese type(3)). The results were as follows; Total sweat rate was highest in obese type, and then comes normal type and slender type in order. Local sweat rate was highest in infrascapular area, and then breast, the back of the hand, upperarm, ant. leg, and ant. thigh in order in all somato types. Mean skin temperature was highest in slender type, and then normal type and obese type in order. Rectal temperature, blood pressure and pulse rate were highest in boese type. Psychological reactions were appeared 'hot' 'humid' 'sweat' as ambient temperature go up. And somato types make little difference in psychological reactions.

  • PDF