• Title/Summary/Keyword: Mean flow coefficient

Search Result 346, Processing Time 0.028 seconds

Detailed Measurement of Flow and Heat Transfer Downstream of Rectanglar Vortex Generators Using a Transient Liquid Crystal Technique (과도 액정 기법을 이용한 와동발생기 하류의 유동장 및 열전달 측정)

  • Hong, Cheol-Hyun;Yang, Jang-Sik;Lee, Ki-Baik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.11
    • /
    • pp.1618-1629
    • /
    • 2003
  • The effects of the interaction between flow field and heat transfer caused by the longitudinal vortices are experimentally investigated using a five hole probe and a transient liquid crystal technique. The test facility consists of a wind tunnel with vortex generators protruding from a bottom surface and a mesh heater. In order to control the strength of the longitudinal vortices, the angle of attack of vortex generators used in the present experiment is 20$^{\circ}$, and the spacing between the vortex generators is 25mm. The height and cord length of the vortex generator is 20mm and 50mm, respectively. Three-component mean velocity measurements are made using a f-hole probe system, and the surface temperature distribution is measured by the hue capturing method using a transient liquid crystal technique. The transient liquid crystal technique in measuring heat transfer has become one of the most effective ways in determining the full surface distributions of heat transfer coefficients. The key point of this technique is to convert the inlet flow temperature into an exponential temperature profile using the mesh heater set up in the wind tunnel. The conclusions obtained in the present experiment are as follows: The two maximum heat transfer values exist over the whole domain, and as the longitudinal vortices move to the farther downstream region, these peak values show the decreasing trends. These trends are also observed in the experimental results of other researchers to have used the uniform heat flux method.

Design of Asymmetric Pre-swirl Stator for LNG Carrier according to Variation of Stator Shapes (날개의 형상 변화에 따른 LNG선용 비대칭 전류고정날개 설계)

  • Lee, Choel-Min;Shin, Yong-Jin;Kim, Moon-Chan;Choi, Jung-Eun;Chun, Ho-Hwan
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.53 no.1
    • /
    • pp.37-44
    • /
    • 2016
  • Recently researchers are conducting a lot of research related to EEDI in order to satisfy IMO resolution MEPC. Especially they are interested in design of energy saving device. This paper is to design the asymmetric pre-swirl stator for 160K LNG carrier in order to reduce energy. Two types of the asymmetric pre-swirl stator are taken into account; constant and variable pitch angle stators. “constant” and “variable” mean state that the pitch of stators change by radius. The dimensions of the stators are initially determined using potential-flow code. The propulsion performances of the stators are predicted using viscous-flow code. The model test is carried out in towing tank in PNU. Prediction of ship performance generally follow ITTC recommended. Ship wake prediction was done by two method, ITTC 1978 and ITTC 1999. Therefore propulsion performances were compared ITTC 1978 with ITTC 1999 methods. Comparison components are delivered power and thrust deduction coefficient of the model. Final pre-swirl stator is selected by comparing experiment and CFD.

Heat transfer performance of a helical heat exchanger depending on coil distance and flow guide for supercritical cryo-compressed hydrogen

  • Cha, Hojun;Choi, Youngjun;Kim, Seokho
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.3
    • /
    • pp.62-67
    • /
    • 2022
  • Liquid hydrogen (LH2) has a higher density than gaseous hydrogen, so it has high transport efficiency and can be stored at relatively low pressure. In order to use efficient bulk hydrogen in the industry, research for the LH2 supply system is needed. In the high-pressure hydrogen station based on LH2 currently being developed in Korea, a heat exchanger is used to heat up supercritical hydrogen at 700 bar and 60 K, which is pressurized by a cryogenic high-pressure pump, to gas hydrogen at 700 bar and 300 K. Accordingly, the heat exchanger used in the hydrogen station should consider the design of high-pressure tubes, miniaturization, and freezing prevention. A helical heat exchanger generates secondary flow due to the curvature characteristics of a curved tube and can be miniaturized compared to a straight one on the same heat transfer length. This paper evaluates the heat transfer performance through parametric study on the distance between coils, guide effect, and anti-icing design of helical heat exchanger. The helical heat exchanger has better heat transfer performance than the straight tube exchanger due to the influence of the secondary flow. When the distance between the coils is uniform, the heat transfer is enhanced. The guide between coils increases the heat transfer performance by increasing the heat transfer length of the shell side fluid. The freezing is observed around the inlet of distribution tube wall, and to solve this problem, an anti-icing structure and a modified operating condition are suggested.

Unsteady galloping of sharp-edged bluff bodies: experimental observations on the effect of the wind angle of attack

  • Chen, Cong;Dai, Bingyu;Wieczorek, Niccolo;Unglaub, Julian;Thiele, Klaus
    • Wind and Structures
    • /
    • v.35 no.4
    • /
    • pp.255-268
    • /
    • 2022
  • Light-weight or low-damped structures may encounter the unsteady galloping instability that occurs at low reduced wind speeds, where the classical quasi-steady assumption is invalid. Although this unsteady phenomenon has been widely studied for rectangular cross sections with one side perpendicular to the incidence flow, the effect of the mean wind angle of attack has not been paid enough attention yet. With four sectional models of different side ratios and geometric shapes, the presented research focuses on the effect of the wind angle of attack on unsteady galloping instability. In static tests, comparatively strong vortex shedding force was noticed in the middle of the range of flow incidence where the lift coefficient shows a negative slope. In aeroelastic tests with a low Scruton number, the typical unsteady galloping, which is due to an interaction with vortex-induced vibration and results in unrestricted oscillation initiating at the Kármán vortex resonance wind speed, was observed for the wind angles of attack that characterize relatively strong vortex shedding force. In contrast, for the wind angles of attack with relatively weak shedding force, an "atypical" unsteady galloping was found to occur at a reduced wind speed clearly higher than the Kármán-vortex resonance one. These observations are valid for all four wind tunnel models. One of the wind tunnel models (with a bridge deck cross section) was also tested in a turbulent flow with an intensity about 9%, showing only the atypical unsteady galloping. However, the wind angle of attack with the comparatively strong vortex shedding force remains the most unfavorable one with respect to the instability threshold in low Scruton number conditions.

Measurement of Shunt Amount Using Radionuclide Angiocardiography: Accuracy According to Level of Shunt and Associated Lesion (방사성 동위원소 심혈관 조영술을 이용한 단락량 측정법: 정확성에 영향을 미치는 인자)

  • Kim, Yang-Min
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.4
    • /
    • pp.200-204
    • /
    • 2006
  • Purpose: Determination of pulmonary to systemic blood flow ratio (QP/QS) is important for the management of patients with left-to-right shunt. This study was performed to assess the agreement of Qp/Qs ratio using the radionuclide method and oxymetry, to investigate the factors influencing the agreement, and to know how interchangeable the results of each technique. Materials and Methods: We compared the Qp/Qs measured by single-pass radionuclide angiocardiography and oxymetry during catheterization in 207 patients who underwent both studies. In radionuclide method, Qp/Qs was calculated from the pulmonary time-activity curves using a gamma variate fit. The correlation and Bland-Altman analysis were performed according to the levels of shunt and associated lesions. Results: The mean Qp/Qs was $1.83{\pm}0.50$ by radionuclide, and $1.74{\pm}0.51$ by oxymetry. The overall correlation coefficient was 0.86(p<0.001), and Bland-Altman range of agreement encompassing 4SD was 1.05. For atrial septal defect, ventricular septal defect, patent ductus arteriosus, tricuspid and mitral insufficiency, the correlation coefficient was 0.78, 0.90, 0.84, 0.63 and 0.44, and Bland-Altman range was 1.51, 0.74, 0.96, 1.57, and 1.50, respectively. Conclusion: There is good agreement but wide variance between the Qp/Qs ratios by radionuclide method and oxymetry. Associated atrioventricular valvar insufficiency decreases the correlation coefficient and widens the variance. Wide overall variance suggests that Qp/Qs measurements by two techniques should not be used interchangeably.

Estimation of stream flow discharge using the satellite synthetic aperture radar images at the mid to small size streams (합성개구레이더 인공위성 영상을 활용한 중소규모 하천에서의 유량 추정)

  • Seo, Minji;Kim, Dongkyun;Ahmad, Waqas;Cha, Jun-Ho
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.12
    • /
    • pp.1181-1194
    • /
    • 2018
  • This study suggests a novel approach of estimating stream flow discharge using the Synthetic Aperture Radar (SAR) images taken from 2015 to 2017 by European Space Agency Sentinel-1 satellite. Fifteen small to medium sized rivers in the Han River basin were selected as study area, and the SAR satellite images and flow data from water level and flow observation system operated by the Korea Institute of Hydrological Survey were used for model construction. First, we apply the histogram matching technique to 12 SAR images that have undergone various preprocessing processes for error correction to make the brightness distribution of the images the same. Then, the flow estimation model was constructed by deriving the relationship between the area of the stream water body extracted using the threshold classification method and the in-situ flow data. As a result, we could construct a power function type flow estimation model at the fourteen study areas except for one station. The minimum, the mean, and the maximum coefficient of determination ($R^2$) of the models of at fourteen study areas were 0.30, 0.80, and 0.99, respectively.

Wind load and wind-induced effect of the large wind turbine tower-blade system considering blade yaw and interference

  • Ke, S.T.;Wang, X.H.;Ge, Y.J.
    • Wind and Structures
    • /
    • v.28 no.2
    • /
    • pp.71-87
    • /
    • 2019
  • The yaw and interference effects of blades affect aerodynamic performance of large wind turbine system significantly, thus influencing wind-induced response and stability performance of the tower-blade system. In this study, the 5MW wind turbine which was developed by Nanjing University of Aeronautics and Astronautics (NUAA) was chosen as the research object. Large eddy simulation on flow field and aerodynamics of its wind turbine system with different yaw angles($0^{\circ}$, $5^{\circ}$, $10^{\circ}$, $20^{\circ}$, $30^{\circ}$ and $45^{\circ}$) under the most unfavorable blade position was carried out. Results were compared with codes and measurement results at home and abroad, which verified validity of large eddy simulation. On this basis, effects of yaw angle on average wind pressure, fluctuating wind pressure, lift coefficient, resistance coefficient,streaming and wake characteristics on different interference zone of tower of wind turbine were analyzed. Next, the blade-cabin-tower-foundation integrated coupling model of the large wind turbine was constructed based on finite element method. Dynamic characteristics, wind-induced response and stability performance of the wind turbine structural system under different yaw angle were analyzed systematically. Research results demonstrate that with the increase of yaw angle, the maximum negative pressure and extreme negative pressure of the significant interference zone of the tower present a V-shaped variation trend, whereas the layer resistance coefficient increases gradually. By contrast, the maximum negative pressure, extreme negative pressure and layer resistance coefficient of the non-interference zone remain basically same. Effects of streaming and wake weaken gradually. When the yaw angle increases to $45^{\circ}$, aerodynamic force of the tower is close with that when there's no blade yaw and interference. As the height of significant interference zone increases, layer resistance coefficient decreases firstly and then increases under different yaw angles. Maximum means and mean square error (MSE) of radial displacement under different yaw angles all occur at circumferential $0^{\circ}$ and $180^{\circ}$ of the tower. The maximum bending moment at tower bottom is at circumferential $20^{\circ}$. When the yaw angle is $0^{\circ}$, the maximum downwind displacement responses of different blades are higher than 2.7 m. With the increase of yaw angle, MSEs of radial displacement at tower top, downwind displacement of blades, internal force at blade roots all decrease gradually, while the critical wind speed decreases firstly and then increases and finally decreases. The comprehensive analysis shows that the worst aerodynamic performance and wind-induced response of the wind turbine system are achieved when the yaw angle is $0^{\circ}$, whereas the worst stability performance and ultimate bearing capacity are achieved when the yaw angle is $45^{\circ}$.

An Experimental Study of the Performance Characteristics on a Multi-Stage Micro Turbine with Various Stages (다단 마이크로터빈에서 단수 변화에 따른 터빈의 성능에 관한 실험적연구)

  • Cho, Chong-Hyun;Cho, Soo-Yong;Choi, Sang-Kyu
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.12
    • /
    • pp.76-82
    • /
    • 2005
  • An experimental study on an axial-type micro turbine which consists of maximum 6 stages is conducted to measure aerodynamic characteristics on each stage. This turbine has a 2.0 flow coefficient, 3.25 loading coefficient and 25.8mm mean diameter. The solidity of stators and rotors is within a 0.67~0.75, and the off-design performance is measured by changing the load after adjusting the mass flowrate and the total pressure to constant at inlet. A maximum specific output power of 2kW/kg/sec is obtained in one stage, but the increment of the specific output power with increasing stages is alleviated. In case of torque, the increment of the torque maintains to constant at low RPM region, but its increment become dull at high RPM region. The efficiency of the micro turbine becomes low because the tip gap effect is great due to the small blade, but it could be improved by increasing the stages.

Performance Evaluation of a Double Layer Biofilter System to Control Urban Road Runoff (I) - System Design - (이중층 토양 여과시설을 이용한 도로 강우 유출수 처리성능 평가 (I) - 시설 설계인자 결정을 중심으로 -)

  • Cho, Kang Woo;Kim, Tae Gyun;Lee, Byung Ha;Lee, Seul Bi;Song, Kyung Guen;Ahn, Kyu Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.5
    • /
    • pp.599-608
    • /
    • 2009
  • This manuscript covers the results of field investigation and lab-scale experiments to design a double-layered biofilter system to control urban storm runoff. The biofilter system consisted of a coarse soil layer (CSL) for filtration and fine soil layer (FSL) for adsorption and biological degradation. The variations of flow rate and water quality of runoff from a local expressway were monitored for seven storm events. Laboratory column experiments were performed using seven kinds of soil and mulch to maximize pollutants removal. The site mean concentration (SMC) of storm runoff from the drainage area (runoff coefficient: 0.92) was measured to be 203 mg/L for SS, 307 mg/L for $TCOD_{Cr}$, 12.3 mg/L for TN, 7.3 mg/L for ${NH_4}^+-N$, and 0.79 mg/L for TP, respectively. This study employed a new design concept, to cover the maximum rainfall intensity with one month recurrence interval. Effective storms for last ten years (1998-2007) in seoul suggested the design rainfull intensity to be 8.8 mm/hr Single layer soil column showed the maximum removal rate of pollutants load when the uniformity coefficient of CSL was 1.58 and the silt/clay contents of FSL was virtually 7%. The removal efficiency during operation of double layer soil column was 98% for SS and turbidity, 75% for TCODCr, 56% for ${NH_4}^+-N$, 87% for TP, and 73-91% for heavy metals. The hydraulic conductivity of the soil column, 0.023 cm/sec, suggested that the surface area of the biofilter system should be about 1% of the drainage area to treat the rainfall intensity of one month recurrence interval.

A Novel Water Surface Detection Method Based on Correlation Analysis for Rectangular Control Area (직사각형 검사영역의 상관도 분석을 통한 수면위치 탐색 방법)

  • Lee, Chan Joo;Seo, Myoung Bae;Kim, Dong Gu;Kwon, Sung Il
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.12
    • /
    • pp.1227-1241
    • /
    • 2012
  • In this study, a novel water surface detection method was proposed. In the method water surface is detected by analysis on correlation coefficients obtained from rectangular control areas of the same vertical position in two successive images including both water surface and staff gauge. Four methods respectively based on threshold, peak, slope and variance ratio, are used to identify water surface from vertical distribution of correlation coefficient. In addition, swaying correction algorithm and statistical filtering are applied to minimize outliers caused by positional image mismatch. Images taken from 28 different sites during low flow were tested to evaluate the method. Mean relative error to eye measurement was approximately from 3.4 to 5.7 cm. As long as water surface moves, this method can be used to improve image stage gauge by supplementing the previous water surface detection method.