• Title/Summary/Keyword: Mean Pressure Control

Search Result 486, Processing Time 0.025 seconds

Effect of Oxygenation of Cardioplegic Solution on Electrical Stability and Postischemic Recovery of Cardiac Function after Ischemic Arrest in Isolated Rat Heart[ I ] (백서의 적출된 심장에서 심정지액의 산소화가 허혈성 심정지후 심기능 회복에 미치는 영향[I])

  • 윤재도
    • Journal of Chest Surgery
    • /
    • v.25 no.2
    • /
    • pp.125-130
    • /
    • 1992
  • To evaluate the effect of oxygenation[95% O2+5% CO2] of St. Thomas Hospital No.2 cardioplegic solution[Plegisol], 20 isolated perfused rat hearts were studied under hyp-othermic[20oC] ischemic arrest for 2 hours with infusion of cardioplegic solution every 30 minutes throughout the ischemic period. Ten isolated hearts were studied with the oxygenated cardioplegic solution and 10 another isolated hearts with the nonoxygenated one. Mean oxygen tensions of the nonoxygenated and oxygenated cardioplegic solutions were 150mmHg and 470mmHg, respectively. Two in 10 hearts infused with the nonaxygenated cardioplegic solution were not recovered from nonworking heart due to persistent ventricular fibrillation. In comparing hem-odynamic parameters between both groups, the mean postischemic recovery[expressed as a percentage of its preischemic control value] was significantly greater with the oxygenated solution[in 10 recovered hearts] than the nonoxygenated solution[in 8 recovered hearts] [95.9$\pm$1.8% compared with 88.5$\pm$2.9% in peak aortic pressure, p<0.05, 75.7$\pm$5.2% compared with 43.5$\pm$6.5% in aortic flow, p<0.01, 75.5$\pm$4.6% compared with 54.1$\pm$5.6% in cardiac output, p<0.01, 78.3$\pm$4.6% compared with 60.3$\pm$4.6% compared with 60.3$\pm$6.2% in stroke volume, p<0.05, and 80.4$\pm$5.3% compared with 58.6$\pm$7.0% in dP/dT, p<0.05]. It is concluded that oxygenation of St. Thomas Hospital No.2 cardioplegic solution improves cardiac electrical stability and postischemic hemodynamic recovery after ischemic arrest in the isolated perfused rat heart.

  • PDF

Electroplating process for the chip component external electrode

  • Lee, Jun-Ho
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.1-2
    • /
    • 2000
  • In chip plating, several parameters must be taken into consideration. Current density, solution concentration, pH, solution temperature, components volume, chip and media ratio, barrel geometrical shape were most likely found to have an effect to the process yields. The 3 types of barrels utilized in chip plating industry are the onventional rotating barrel, vibrational barrel(vibarrel), and the centrifugal type. Conventional rotating barrel is a close type and is commonly used. The components inside the barrel are circulated by the barrel's rotation at a horizontal axis. Process yield has known to have higher thickness deviation. The vibrational barrel is an open type which offers a wide exposure to electrolyte resulting to a stable thickness deviation. It rotates in a vertical axis coupled with multi-vibration action to facilitate mixed up and easy transportation of components. The centrifugal barrel has its plated work centrifugally compacted against the cathode ring for superior electrical contact with simultaneous rotary motion. This experiment has determined the effect of barrel vibration intensity to the plating thickness distribution. The procedures carried out in the experiment involved the overall plating process., cleaning, rinse, Nickel plating, Tin-Lead plating. Plating time was adjusted to meet the required specification. All other parameters were maintained constant. Two trials were performed to confirm the consistency of the result. The thickness data of the experiment conducted showed thatbthe average mean value obtained from higher vibrational intensity is nearer to the standard mean. The distribution curve shown has a narrower specification limits and it has a reduced variation around the target value. Generally, intensity control in vi-barrel facilitates mixed up and easy transportation of components. However, it is desirable to maintain an optimum vibration intensity to prevent solution intrusion into the chips' internal electrode. A cathodic reaction can occur in the interface of the external and internal electrode. 2H20 + e $\rightarrow$M/TEX> 20H + H2.. Hydrogen can penetrate into the body and create pressure which can cause cracks. At high intensity, the chip's motion becomes stronger, its contact between each other is delayed and so plating action is being controlled. However, the strong impact created by its collision can damage the external electrode's structure there by resulting to bad plating condition.

  • PDF

Correlations between the Muscle Thickness of the Transverse Abdominis and the Multifidus Muscle with Spinal Alignment in College Students (대학생의 배가로근과 뭇갈래근 두께와 척추정렬간의 상관관계)

  • Lim, Jae-Heon
    • PNF and Movement
    • /
    • v.12 no.4
    • /
    • pp.243-248
    • /
    • 2014
  • Purpose: The transverse abdominis and themultifidus muscle are located in the core. They surround one's trunk and help in body stabilization. Specifically, they control spine articulation to maintain posture and balance. Therefore, weakened deep muscle in the trunk may cause spinal malalignment. This study aims to compare the correlation between the thickness of the transverse abdominis and the multifidus muscle and the spine alignment among college students in their 20s. Methods: This study measured the thickness of the transverse abdominis and the multifidus muscle of 42 healthy college students in their 20s using ultrasonic waves. The thickness of the muscle was measured for the length of the cross-section except for fascia. The thickness of the left and right muscles was measured, and the mean value was calculated. As the thickness of the transverse abdominis can increase because of pressure during exhalation, it was measured at the last moment of exhalation. Spinal alignment was measured by the kyphosis angle, lordosis angle, pelvic tilt, trunk inclination, lateral deviation, trunk imbalance, and surface rotation using Formetric III, which is a three-dimensional imaging equipment. They were measured for three times, and the mean values were calculated. The general characteristics of the subjects were analyzed using descriptive statistics. The correlations between each factor were analyzed using Pearson's correlation analysis. Results: The transverse abdominis showed asignificant correlation with trunk inclination (p<.05). The multifidus muscle showed a significant positive correlation with pelvic tilt and a negative correlation with surface rotation (p<.05). Conclusion: The thickness of transverse abdominis and the multifidus muscle appears to influence spinal alignment. Specifically, the multifidus muscle, which plays an important role on the sagittal plane, influences surface rotation, thus making it an important muscle for scoliosis patients. Therefore, a strengthening training program for the transverse abdominis and the multifidus muscle is necessary according to specific purposes among adults with spinal malalignment.

The Effects of Nitric Oxide Inhibitor on Hyperdynamic Circulation in Portal Hypertensive Rats (산화 질소 억제제가 문맥 고혈압 쥐의 혈역학 변화에 미치는 영향)

  • Kim, Pill-Young;Jang, Byeong-Ik;Kim, Tae-Nyeun;Chung, Moon-Kwan
    • Journal of Yeungnam Medical Science
    • /
    • v.16 no.2
    • /
    • pp.181-192
    • /
    • 1999
  • Background: Nitric oxide, a vasodilator synthesized from L-arginine by vascular endothelial cells, accounts for the biological activity of endothelium derived relaxing factor. Previous studies demonstrated that nitric oxide inhibitor, $N^{\omega}$-Nitro-L-Arginine(NNA) diminished the hyperdynamic splanchnic and systemic circulation in portal hypertensive rats The present study was done to determine the role of nitric oxide in the development of hyperdynamic circulations in the prehepatic portal hypertensive rat model produced by partial portal vein ligation. Methods: The portal hypertensive rats were divided into water ingestion group and NNA ingestion group. After partial portal vein ligation, NNA ingestion group and water ingestion group received NNA 1mg/kg/day and plain water through the mouth for 14 days, respectively. Cardiac output, mean arterial pressure, organ blood flow and porto-systemic shunting were measured by radioisotope labeled microsphere methods. Vascular resistances were calculated by standard equation. Results: There were significant decreases in mean arterial pressure, increases in cardiac output and cardiac index, and decreases in total systemic and splanchnic vascular resistance in portal hypertensive rats compared to normal control group (p<0.01). Compared to the water ingestion group, significantly increased mean arterial pressure with decreased cardiac output and cardiac index were developed in the NNA ingestion group. Total systemic and splanchnic vascular resistance were significantly increased in the NNA ingestion group compared to water ingestion group (p<0.05). But, there was no significant difference in portal pressure between the two groups. Conclusion: The hemodynamic results of this study indicate that hyperdynamic circulation in prehepatic portal hypertensive rat mode1 was attenuated by ingestion of NNA. Nitric oxide may play an important role in the development of hyperdynamic circulation with splanchnic vasodilation in chronic portal hypertension.

  • PDF

Mechanism of Palmul- Tang on the Change of Cerebral Hemodynamics in Rats (팔물탕이 뇌혈유력학 변화에 미치는 작용기전)

  • Park Cheol Hun;Kim Gye Yeop;Jeong Hyun Woo
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.18 no.6
    • /
    • pp.1714-1721
    • /
    • 2004
  • This experimental study was designed to investigate the mechanism of Palmul-Tang(PMT) on the changes of cerebral hemodynamics in rats. The changes of cerebral hemodynamics in normal rats were as follows ; The PMT-induced increase in regional cerebral blood flow was significantly inhibited by pretreatment with indomethacin(1㎎/㎏, i.p.), an inhibitor of cyclooxygenase, and was inhibited by methylene blue(10㎍/㎏, i.p.), an inhibitor of guanylate cyclase. The PMT-induced dilation in pial arterial diameter was significantly inhibited by pretreatment with indomethacin and methylene blue. The PMT-induced increase in mean arterial blood pressure was significantly inhibited by pretreatment with indomethacin but was increased by methylene blue. This results were suggested that the mechanism of PMT was mediated by cyclooxygenase. The changes of cytokine production in cerebral ischemic rats were as follows ; In cytokine production of serum by drawing from femoral arterial blood after middle cerebral arterial occlusion 1hr, sample group was decreased IL-1β and TNF-α production compared with control group, IL-10 production of sample group was similar to that of control group, but sample group was significantly increased TGF-β production compared with control group. In cytokine production of serum by drawing from femoral arterial blood after reperfusion 1hr, sample group was significantly decreased IL-1β production compared with control group and decreased TNF-α production compared with control group. IL-10 production of sample group was similar to that of control group, but sample group was significantly increased TGF-β production compared with control group. In cytokine production of serum by drawing from femoral arterial blood after reperfusion 4 hrs, sample group was significantly decreased IL-1β production compared with control group, but IL-10 production of sample group was similar to that of control group. sample group was increased TNF-α and TGF-β production compared with control group. These results suggested that PMT had inhibitive effect on the brain damage by inhibiting IL-1β and TNF-α production, but by accelerating TGF-β production. The present author thought that PMT had an anti-ischemic effect through the improvement of cerebral hemodynamics and inhibitive effect on the brain damage.

Experimental Investigations of Flow Characteristics by Wing Type Vortex Generators Set up Behind a Circular Cylinder in a Rectangular Channel (사각채널내 와동발생기가 부착된 원형실린더 하류 유동 특성에 대한 실험적 연구)

  • 이상민;하홍영;양장식;이기백
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.5
    • /
    • pp.1076-1085
    • /
    • 2001
  • Experimental investigations of the longitudinal vortices, which are produced by wing type vortex generators set up behind a circular cylinder in a rectangular channel, are presented. When the circular cylinder is set up in the rectangular channel, a horseshoe vortex is formed just upsteam of the circular cylinder. It generates a turbulent wake region behind the circular cylinder. Therefore, the region of the pressure loss behind the circular cylinder in increased and the size of the wake is small. These problems can be achieved by longitudinal vortices which are generated by wing-type vortex generator. In order to control the strength of longitudinal vortices, the angle of attack of the vortex generators is varied from 20 degree to 45, but the spacing between the vortex generators is fixed 6cm. The 3-dimensional mean velocity measurements are made using a five-hole probe. The vorticity field and streamwise velocity contour are obtained from the velocity field. The following results are obtained. Circulation strength is the maximum value when the angle of attack($\beta$) is $30^{\circ}$, and the vorticity field and streamwise velocity contour in case of $\beta$=$20^{\circ}$ show the trend similar to these in case of $\beta$=$30^{\circ}$, but do not in case of $\beta$=$45^{\circ}$.

  • PDF

An attenuation effect of noise according to the direction of secondary sound source in duct ANC system (Duct ANC 시스템에서 2차음원 방향별 소음감소효과)

  • Lee, Hyung-Seok;Lee, Eung-Suk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.497-502
    • /
    • 2008
  • In this paper, we studied on an attenuation effect of automobile exhaust noise according to the direction of secondary sound source in duct ANC system. Automobile exhaust noise was recorded at 800rpm. 3500rpm and 5000rpm of a diesel engine. Directions of loudspeaker(second sound source) can be exchanged to $30^{\circ}$, $90^{\circ}$ and $150^{\circ}$ against the primary noise flow by acrylic ducts to be made for experimentation. DSP board with TMS320C6416 chip of Texas Instrument Co used to control adaptive ANC system. This ANC system is based on the single-channel FxLMS algorithm. In experiment result, when the loud speaker direction was $150^{\circ}$, the attenuation effect showed largely. In case of $90^{\circ}$ duct, the noise was a little increased. In case of $30^{\circ}$ duct, the noise was a little increased or decreased according to the frequency range and the sound pressure(dB) of exhaust noise to comply with engine rpm.

  • PDF

Two-Dimensional Echocardiographic Preoperative Prediction of Prosthetic Valve Size (이면성 심초음파도로 구한 대동맥판륜부 크기와 실제 치환된 판막크기와의 비교연구)

  • 정태은
    • Journal of Chest Surgery
    • /
    • v.21 no.6
    • /
    • pp.979-983
    • /
    • 1988
  • Calcium channel blockers may prevent myocardial injury during cardioplegia and reperfusion. This study was done to evaluate the effects of diltiazem cardioplegia on myocardial protection during ischemic arrest and recovery of myocardial function after reperfusion. Four formulations of crystalloid cardioplegic solutions, GIK solution[group I, n=12], diltiazem[lug/ml GIK] in GIK solution[group II, n=7], ],diltiazem[2ug/ml GIK] in GIK solution[group III, n=6] and diltiazem[4ug/ml GIK] in GIK solution[group IV, n=6] were compared in isolated working rat heart subjected to a long period [2 hours] of hypothermic arrest with multi-dose infusion. Diltiazem cardioplegia[group II, III and IV]was found to be superior in nearly all aspects. Diltiazem cardioplegia showed faster recovery of regular rhythm and lower incidence of ventricular fibrillation than group I did. In comparing mechanical function in all experimental hearts, the mean postischemic recoveries of aortic flow, cardiac output, peak aortic pressure, stroke volume and stroke work[expressed as a percentage of its preischemic control] were significantly greater in group II, III and IV[diltiazem cardioplegia] than in group I. The infused amount of cardioplegic solution was more increased by the addition of diltiazem to GI K solution. [p < 0.01] Creatine kinase leakage tended to be lower in hearts receiving diltiazem cardioplegia, especially in group III and IV[p<0.05] than in those receiving GIK solution only[group I]. Diltiazem cardioplegia results in the increased flow of cardioplegic solution and the decreased ischemic injury of myocardium during ischemic arrest and the improved recovery of myocardial function after reperfusion, and a dose-response relation must be established before clinical use.

  • PDF

Relationship among Bone Mineral Density, Body Composition, and Metabolic Syndrome Risk Factors in Females

  • Kim, Tai-Jeon;Cha, Byung-Heun;Shin, Kyung-A
    • Biomedical Science Letters
    • /
    • v.16 no.3
    • /
    • pp.169-177
    • /
    • 2010
  • Osteoporosis is a disease that increases the fracture rates and a major cause of increased mortality and morbidity in the elderly people. This study is to determine which components of body composition and metabolic syndrome risk factors are important to bone health, we analysed the relationship among bone mineral density (BMD), body composition and metabolic syndrome risk factors in females. Totally 630 females participated in a medical check-up program (mean age 47 years) were selected for this study. Body composition analysis was performed by segmental bioelectrical impedance method, muscle mass, and percent body fat were measured. We also measured metabolic syndrome risk factors including abdominal obesity, HDL-cholesterol, triglyceride, blood pressure and fasting glucose level. Metabolic syndrome was defined by NCEP-ATP III criteria. The lumbar spine and femoral neck BMD were measured using the dual energy X-ray absorptiometry. Osteopenia and osteoporosis were observed in 180 and 51 persons, respectively. Muscle mass and HDL-cholesterol decreased in osteopenia and osteoporosis groups compared to the control group, and the grade was shown progressively by the symptoms. Significant positive correlation between BMD and muscle mass was observed. Multi variable regression analyses showed that % body fat and muscle mass were independent predictors of BMD after adjustment of age, height and weight. In conclusion, the BMD showed negative correlation with the metabolic and body composition was associated with BMD.

A Study on the Injection Characteristics of a Piezo Injector for Controlling Accurate Multiple Injection (커먼레일 타입 피에조 인젝터의 정밀 다단분사 제어를 위한 분사특성 연구)

  • Park, Heebum;Kim, Hyungik;Park, Sangki;Lee, Kihyung
    • Journal of ILASS-Korea
    • /
    • v.18 no.4
    • /
    • pp.176-181
    • /
    • 2013
  • In this study, injection quantity, rate and spray image of multiple injections which are important design parameters for a piezo type injector have been investigated. Interval of injections and a number of injections in multiple injection strategy has been controlled to verify interaction of each injection. Spray characteristics of multiple injections have been researched through optical process with a high speed camera in a high pressure chamber. In addition, a method of RMS(Root Mean Square) process has been used for comprehending the distribution of injection easily. As a result, in case of piezo type injector, characteristics of injection quantity according to charging voltage and the difference of injection quantity between single and triple injection were confirmed. Also, injection rate for increasing injection duration was confirmed. And spray characteristics of multiple injections were improved; multiple injections were possible in a shorter time interval between each injection. With this study, a possibilities of more accurate multiple injection control would be expected.