• 제목/요약/키워드: Mean Load

검색결과 981건 처리시간 0.025초

비점오염원 관리지역의 선정 기법에 관한 연구 (A Study for the Selection Method of Control Area of Nonpoint Pollution Source)

  • 박상현;정우혁;이상진;임봉수
    • 한국물환경학회지
    • /
    • 제26권5호
    • /
    • pp.761-767
    • /
    • 2010
  • This study introduces a model of territorial analysis on Chungcheongnam-do Nonsan-chun valley area, which gives an example of a method of selecting the management area for non-point pollution source from land use to help eliminate its source. High discharge load per unit area signify high level of land ratio with high level of basic unit of development load (including factory sites, school sites, roadways), which mean that there are a significant level of urbanization. It is these areas with the examination of the water quality of the nearby river that should be considered as the management area for non-point pollution source. Thus, the management area for non-point pollution source should be sought in areas with high discharge load per unit area and high density of water pollution area. When level of drainage is high the pollution density level is relatively lower, and when the level of drainage is low the density level is relatively higher. The level of pollution from non-point pollution source is much lower with more water flowing through. The possible non-point pollution source areas that were selected with these standards were then examined with the distance from the river, the slope angle, land usage, elevation, BOD discharge density load, T-N discharge density load, T-P discharge density load, and were given a level one through five. Out of the possible areas Nonsan-si Yeonmu-eup Anshim-li was the densest area, and it was given level one. The level one area should be examined further with the field analysis to be selected as the actual management area for non-point pollution source.

일관성에 기초한 적응 부하 평형 (Adaptive Load Balancing based on Consistency)

  • 김준형;오하령;이재문
    • 한국정보처리학회논문지
    • /
    • 제2권3호
    • /
    • pp.288-298
    • /
    • 1995
  • 부하 평형은 과부하 사이트의 부하종 일부를 다른 사이트로 옮김으로써 분산 처리 시스템의 성능 개선을 꾀한다. 본 논문에서는 source-initiate와 server-initiate 방 식을 모두 지원하며 극단적인 예로서 m/m/1 대기행렬(부하 비평형)과 m/m/n 대기 행렬 (완전한 부하 평형)도 모델화 할 수 있는 부하 평형 방식을 제안하였다. 이 방식은 상 태 변수를 각 사이트에 복제하고 각 복사본의 일치성을 완화한다. 그리고 오래된 스케 줄러가 통신을 하지 않고도 부하 평형을 보장할 수 있는 충분조건을 요도하였다. 이 모델을 이용하면 부하 평형의 문제가 상태의 일관성을 유지하는 문제로 바뀌게 되며 기존의 비딩 알고리즘보다 통신량이 적어지게 된다. 이벤트 트레이싱 방법으로 모의 실험하였으며 2개의 극단적인 경우 및 비딩알고리즘과 비교하였다. 그 결과 평균 응답 시간과 통신량에 있어서 비딩알고리즘보다 각각 0-35%, 40-100%의 성능향상을 보였다. 마지막으로 각 시스템 피라미터의 영향을 분석하였다.

  • PDF

컨테이너 크레인의 전산유동해석과 풍동실험에 의한 풍하중 분석 (Wind Load Analysis owing to the Computation Fluid Dynamics and Wind Tunnel Test of a Container Crane)

  • 이수홍;한동섭;한근조
    • 한국항해항만학회지
    • /
    • 제33권3호
    • /
    • pp.215-220
    • /
    • 2009
  • 컨테이너 크레인은 강풍으로부터 보호를 받기 위한 차폐물이 없는 곳에 존재하기 때문에 이상 기후 조건에 취약성이 있는 구조물이다. 본 연구에서는 붐 각도의 변화에 따라 풍동실험과 전산유동 해석을 사용하여 컨테이너 크레인의 구조물에 대한 풍하중의 영향을 수행하였다. 그리고 75m/s의 풍속을 컨테이너 크레인에 적용하였다고 가정하였을 때 컨테이너 크레인의 풍력 내구성 설계에 사용되는 데이터를 컨테이너 크레인 설계자에게 제공하고자 한다. 본 연구에서는 건축물 하중기준의 풍하중 설계기준에 따라 풍하중을 적용하였으며 풍향에 따른 영향을 분석하기 위해서 유동장을 $10^{\circ}$ 간격으로 분할하였다. 이를 바탕으로 풍동실험과 전산 유동해석을 수행하였으며 얻어진 결과들을 비교 연구함으로써 컨테이너 크레인의 구조설계에 필요한 풍하중을 분석하였다.

Wind loads on fixed-roof cylindrical tanks with very low aspect ratio

  • Lin, Yin;Zhao, Yang
    • Wind and Structures
    • /
    • 제18권6호
    • /
    • pp.651-668
    • /
    • 2014
  • Wind tunnel tests are conducted to investigate the wind loads on vertical fixed-roof cylindrical tanks with a very low aspect ratio of 0.275, which is a typical ratio for practical tanks with a volume of $100,000m^3$. Both the flat-roof tank and the dome-roof tank are investigated in present study. The first four moments of the measured wind pressure, including the mean and normalized deviation pressure, kurtosis and skewness of the pressure signal, are obtained to study the feature of the wind loads. It is shown that the wind loads are closely related to the behavior of flow around the structure. For either tank, the mean wind pressures on the cylinder are positive on the windward area and negative on the sides and the wake area, and the mean wind pressures on the whole roof are negative. The roof configurations have no considerable influence on the mean pressure distributions of cylindrical wall in general. Highly non-Gaussian feature is found in either tank. Conditional sampling technique, envelope method, and the proper orthogonal decomposition (POD) analysis are employed to investigate the characteristics of wind loads on the cylinder in more detail. It is shown that the patterns of wind pressure obtained from conditional sampling are similar to the mean pressure patterns.An instantaneous pressure coefficient can present a wide range from the maximum value to the minimum value. The quasi-steady assumption is not valid for structures considered in this paper according to the POD analysis.

Influence of second order wave excitation loads on coupled response of an offshore floating wind turbine

  • Chuang, Zhenju;Liu, Shewen;Lu, Yu
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제12권1호
    • /
    • pp.367-375
    • /
    • 2020
  • This paper presents an integrated analysis about dynamic performance of a Floating Offshore Wind Turbine (FOWT) OC4 DeepCwind with semi-submersible platform under real sea environment. The emphasis of this paper is to investigate how the wave mean drift force and slow-drift wave excitation load (Quadratic transfer function, namely QTF) influence the platform motions, mooring line tension and tower base bending moments. Second order potential theory is being used for computing linear and nonlinear wave effects, including first order wave force, mean drift force and slow-drift excitation loads. Morison model is utilized to account the viscous effect from fluid. This approach considers floating wind turbine as an integrated coupled system. Two time-domain solvers, SIMA (SIMO/RIFLEX/AERODYN) and FAST are being chosen to analyze the global response of the integrated coupled system under small, moderate and severe sea condition. Results show that second order mean drift force and slow-drift force will drift the floater away along wave propagation direction. At the same time, slow-drift force has larger effect than mean drift force. Also tension of the mooring line at fairlead and tower base loads are increased accordingly in all sea conditions under investigation.

균질화법을 이용한 충돌 최적화 기초 연구(II) (A Basic Study of Crashworthiness Optimization Using Homogenization Method(II))

  • 조용범;신효철
    • 한국자동차공학회논문집
    • /
    • 제10권4호
    • /
    • pp.181-191
    • /
    • 2002
  • The homogenization method is applied to maximize crash energy absorption for a given volume. Optimization analysis off closed-hat type example problem is conducted with different impact velocities and thicknesses. The results show that the bending-type deformation for the original design is changed to the folding-type deformation for a new design with a hole, which is partly due to the increase of the crash energy absorption for the new design. Dynamic mean crushing loads of the original and new design are compared with those by the theoretical equation by Wierzbicki. It shows that the dynamic mean crushing loads of new designs are very close to those by Wierzbicki's equation.

혼합모드 피로문제에서의 최소 변형에너지 밀도기준의 적용 (An Application of Minimum Strain Energy Density Criterion in Mixed Mode Fatigue Problem)

  • 심규석;구재민
    • 한국안전학회지
    • /
    • 제17권2호
    • /
    • pp.1-7
    • /
    • 2002
  • In this paper, the maximum minimum strain energy density criterion was applied to the mixed mode fatigue test of A5052 H34 alloy. In this study result we can have seen that the authors stress intensity factor for the finite width specimen and method of determining testing load, based on the plastic zone size and the limited maximum stress intensity factor by ASTM STANDARD E-647-95, is useful.

운전조건변화에 따른 피스톤-링 결합체 마찰특성 (Friction Characteristics of the Piston-Ring Assembly Varying Engine Operation Coditions)

  • 윤정의;김승수
    • 대한기계학회논문집
    • /
    • 제18권6호
    • /
    • pp.1510-1519
    • /
    • 1994
  • It is important to understand the friction characteristics between piston-ring assembly and cylinder wall for the friction loss reduction as well as the solution of problem such as scuffing wear and oil consumption. A new system was developed for the piston-ring assembly friction force measurement. This system was applied to the friction force measurement to find its functional relationship with variables such as engine speed, oil viscosity, and engine load. The friction mean effective pressure(fmep) was found to have a linear relationship with$(\vpsilon{U})^{0.42}$ under motering and with$(\vpsilon{U})^{0.45}$ under firing operations, where $\vpsilon$ is the kinematic oil viscosity and U is mean piston speed.

비대선(肥大船)의 항주중(航走中)의 자세변화(姿勢變化)와 형상영향계수(形狀影響係數)에 관(關)하여 (An Experimental Study on Mean Sinkage and Trim Change in Run, and Form Factor of Full Hull Form)

  • 홍성완
    • 대한조선학회지
    • /
    • 제8권1호
    • /
    • pp.29-40
    • /
    • 1971
  • In order to study the problem on form factor of hull form, towing test of a full ship model was carried out for different initial trims under both full and half load conditions. The results were fully discussed on the mutual relations among initial trim, mean sinkage and trim change in run, and form factor. There exists optimum initial trim in regard to form factor. Mean sinkage and trim change in run can be expressed in a uninominal approximation in the form of $k_i{\cdot}{F_n}^{2.2}$. The coefficients of this approxmation are related linearly with the initial trim. Form factor changes according to Froude number. It is considered that the trim change in run is a main reason of the fact.

  • PDF