• Title/Summary/Keyword: Mean Flow Field

Search Result 474, Processing Time 0.03 seconds

Operation Results and Utility of Dynamic Pricing Response Control-Applied VRF System in Summer Season

  • Kim, Min-seok;Lee, Je-hyeon;Song, Young-hak
    • Architectural research
    • /
    • v.19 no.3
    • /
    • pp.71-77
    • /
    • 2017
  • Dynamic pricing refers to a system in which a tariff varies, according to a level of charging and applied time depending on time change. The power billing system used in the Korean Electric Power Corporation (KEPCO) is based on time of use (TOU) pricing, which is one of the dynamic pricing systems. This paper aimed to determine the operational results of a variable refrigerant flow system, to which a new control algorithm was applied, in order to respond to dynamic pricing, in summer and the utility of the new control. To do this, real measured data was acquired from a VRF system installed in a building for educational purposes, where dynamic pricing was applied for about 100 days during summer time. At the maximum load operation time period in TOU, the new control minimized operation within the indoor comfort range, an increase in refrigerant evaporation temperature in the indoor unit and the number of revolutions in a compressor in the outdoor unit was limited. As a result, power usage was decreased by 11%, and the operational cost by 14.6%. Furthermore, measurement results using the Predicted Mean Vote (PMV) model, that represented satisfaction of thermal environment, showed that 82.8% to 90.4% of the occupants of the building were satisfied during operation when the new control was applied.

A theoretical study on the extinction of the premixed flame in a tube caused by a logitudinal velocity variation (축방향 유속변동에 의한 관내 예혼합화염의 소화특성에 관한 이론적 연구)

  • Kim, Nam-Il;Shin, Hyun-Dong;Bae, Choong-Sik
    • 한국연소학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.111-118
    • /
    • 2001
  • Many previous researches on the premixed flame in a tube have treated the unsteady flame behaviors but more detailed and fundamental research has been necessary. The study on the flame stabilization condition in a tube and the unsteady behaviors were carried out in recent years. In this paper, a mean velocity variation larger than the burning velocity was introduced to the stabilized flame for a period longer than the reaction time scale in order to examine the unsteady behavior of flame propagation. Through our previous work it was found that the effects of non-unity Lewis number on the flame extinction was negligible in the extinction by the boundary layer even though they were important in the extinction by the acoustic instability. In this paper we carried out an analytic approach to explain the previous experimental results. It showed that the heat loss, from a flame to the wall, is not a sufficient condition but a required one for the growth of the extinction boundary layer. In addition, the quenching and the flame stretch, under a strong unsteady flow field, are the main causes of the eventual extinction.

  • PDF

Determination of 2D solar wind speed maps from LASCO C3 observations using Fourier motion filter

  • Cho, Il-Hyun;Moon, Yong-Jae;Lee, Jin-Yi;Nakariakov, Valery;Cho, Kyung-Suk
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.2
    • /
    • pp.68-68
    • /
    • 2017
  • Measurements of solar wind speed near the Sun (< 0.1 AU) are important for understanding acceleration mechanism of solar wind as well as space weather predictions, but hard to directly measure them. For the first time, we provide 2D solar wind speed maps in the LASCO field of view using three consecutive days data. By applying the Fourier convolution and inverse Fourier transform, we decompose the 3D intensity data (r, PA, t) into the 4D one (r, PA, t, v). Then, we take the weighted mean along speed to determine the solar wind speeds that gives V(r, PA, t) in every 30 min. The estimated radial speeds are consistent with those given by an artificial flow and plasma blobs. We find that the estimated speeds are moderately correlated with those from slow CMEs and those from IPS observations. A comparison of yearly solar wind speed maps in 2000 and 2009 shows that they have very remarkable differences: azimuthally uniform distribution in 2000 and bi-modal distribution (high speed near the poles and low speed near the equator) in 2009.

  • PDF

Study on the Behavior Characteristics of Gasoline-Fuel Spray by Using a Numerical Analysis (수치해석을 이용한 가솔린연료 분무 거동특성 연구)

  • Yeom, Jeong-Kuk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.12
    • /
    • pp.992-999
    • /
    • 2009
  • The focus of this study is placed on the behavior characteristics of gasoline spray under condition field of room temperature and pressure. To analyze the behavior and flow characteristics of injected fuel spray is important in speculation of mixture formation process. Also the exhausted emissions from actual engines can be controlled by the analyzed results. The ${\varphi}$(degree of freedom) and K(energy ratio of particle motion) are selected as the simulation parameter. The factors affect characteristics of spray structure, and the factors are included in the sub-program of the KIVA-II code. In this study, the simulation study by modified KIVA-II code was conducted and the calculated results obtained by the modified KIVA-II code show good agreements with experimental results. As a result, applying the improved TAB model with ${\varphi}$=8 and K=2 to simulation analysis of the KIVA-II code is sufficiently useful for analyzing the macro characteristics in spray structure, such as the spray tip penetration of injected fuel spray.

Twin Spray Characteristics Between Two Impinging F-O-O-F Type Injectors

  • Kang, Shin-Jae;Lee, Eun-Sang;Kwon, Ki-Chul;Oh, Je-Ha;Yu, Myoung-Jong
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.732-742
    • /
    • 2002
  • This paper presents twin spray characteristics of two impinging F-O-O-F type injectors in which fuel and oxidizer impinge on each other to atomize under the various conditions. The droplet size and velocity in the impinging spray flow field were measured using PDPA. The droplet size and velocity were investigated at the mixture ratios of 1.5, 2.0, 2.47 and 3.0 for four injectors in which two single F-O-O-F injectors were arranged at the intervals of 20.8, 31.2, 41.6 and 62.4mm respectively. In general, the arithmetic mean diameter, SMD and standard deviation of droplet size in the interaction area (X=0 and Y=0mm) were smaller, while the axial velocity in the interaction area was slightly higher. An empirical correlation is obtained for the (D$\_$10/)$\_$D//(D$\_$10/)$\_$c/ value under the assumptions of two identical droplets and these with different size and velocity. The droplets with low Weber numbers below 40 have possibility to coalesce, while those over 40 tend to disintegrate after impingement in the interaction area.

Spray Characteristics in the cross region of twin spray between impinging F-O-O-F type injectors (충돌형 F-O-O-F 인젝터의 이중분무 중첩영역에서의 분무특성에 관한 연구)

  • Kwon, K.C.;Lee, E.S.;Kang, S.J.;Rho, B.J.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.758-763
    • /
    • 2001
  • This paper presents twin spray characteristics of two impinging F-O-O-F type injectors in which fuel and oxidizer impinge on each other to atomize under the various conditions. The droplet size and velocity in the impinging spray flow field were measured using a PDPA. The droplet size and velocity were investigated at mixture ratios of 1.5, 2.0, 2.47 and 3.0 for four injectors in which two single F-O-O-F injectors were arranged at intervals of 20.8, 31.2, 41.6 and 62.4mm respectively. In general, the arithmetic mean diameter, SMD and standard deviation of droplet size in the interaction area (X=0 and Y=0mm) were smaller. The axial velocity in the interaction area was slightly higher. Considering the behavior of impinged droplets using the We number calculated by using the axial velocity instead of the relative velocity in line C in Fig. 1(b) for four injectors, it is consumed that the We number over 500 had the possibility to disintegrate, and the We number below 500 had it to cohere after impingement of twin spray. The results of this study can be used for the design of a nozzle for liquid propellant rockets.

  • PDF

A Case Study for Reasonable Emission Regulation of Odor Exhaust Stack (악취 배출구의 합리적인 배출규제를 위한 사례연구)

  • Park, Jeong-Ho;Lee, Hyung-Chun
    • Journal of Environmental Science International
    • /
    • v.25 no.1
    • /
    • pp.155-161
    • /
    • 2016
  • In this study, field experiment, odor simulator, and dispersion modeling were used to evaluate the odor impact from J sewage sludge treatment facility. The height and flow rate of exhaust stack at this facility were 22.3 m and $100Nm^3/min$. The mean odor concentrations of the wet scrubber inlet and exhaust stack were $267{\pm}160$ and $93{\pm}44OU/m^3$, respectively. The odor removal efficiency of wet scrubber showed 65%. The odor simulator is used for the regulated standard calculation of the exhaust pipe(stack). Resulting odor emission rate(OER) by odor simulator was $2.4{\times}10^6(24,000OU/m^3)$. The forecasting result by Screen3 modeling showed that odor exhaust concentration up to $30,000OU/m^3$ was't exceeded maximum allowable emission level on site boundary($15OU/m^3$).

Near-Wall Modelling of Turbulent Heat Fluxes by Elliptic Equation (타원방정식에 의한 벽면 부근의 난류열유속 모형화)

  • Shin, Jong-Keun;An, Jeong-Soo;Choi, Young-Don
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.5
    • /
    • pp.526-534
    • /
    • 2004
  • A new second-moment closure model for turbulent heat fluxes is proposed on the basis of the elliptic equation. The new model satisfies the near-wall balance between viscous diffusion, viscous dissipation and temperature-pressure gradient correlation, and also has the characteristics of approaching its respective conventional high Reynolds number model far away from the wall. The predictions of turbulent heat transfer in a channel flow have been carried out with constant wall heat flux and constant wall temperature difference boundary conditions respectively. The velocity field variables are supplied from the DNS data and the differential equations only fur the mean temperature and the scalar flux are solved by the present calculations. The present model is tested by direct comparisons with the DNS to validate the performance of the model predictions. The prediction results show that the behavior of the turbulent heat fluxes in the whole region is well captured by the present model.

Characteristics of Ultrafine SiO$_2$Particle Synthesized by Electro-Hydrodynamic Spray Injection in a Furnace (반응로내 전기-수력학적 분사에 의한 비응집 초미세 SiO$_2$ 입자 합성과 특성)

  • Yun, Jin-Uk;Yang, Tae-Hun;An, Gang-Ho;Choe, Man-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.5
    • /
    • pp.660-665
    • /
    • 2001
  • Ultrafine particles have been widely used in many high technology industrial areas. The spherical nonagglomerated and uniform nanometer-size SiO$_2$particles are synthesized by the direct injection of TEOS(Tetraethyorthosilicate) using electro-hydrodynamic spraying method. Electro-hydrodynamic spraying can generate submicron-size TEOS droplets having high electric charges by applying a high electric field between the liquid injection nozzle and the reaction tube. These TEOS droplets are evaporated, and thermally decomposed or oxidized to produce nanometresized SiO$_2$particles in the reaction tube. Spherical, nonagglomerated and ultrafine particles are generated in various conditions and examined by using SEM and SMPS. As the total gas flow rate in the furnace changes from 1.5 lpm, the mean diameter of SiO$_2$particle decreases from 120 nm to 68 nm. The synthesized particle charging fractions are also investigated.

Numerical Analysis of Stress Regimes in and around Inactive and Active Fault Zones (비활성 그리고 활성 단층지역 내부와 주변에서의 응력장에 대한 수치적 분석)

  • Jeong, Woo-Chang;Song, Jai-Woo
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.1 no.1 s.1
    • /
    • pp.117-125
    • /
    • 2001
  • This paper presented the analysis of stress regimes in and around inactive and active fault zones. The stress regime in the vicinity of an existing inactive fault zone is dependent on the orientation of the fault with respect to the current stress field and the contrast between the elastic properties of the faulted rock and those of the surrounding rock. In the analysis of stress regimes around an active fault zone, if the yielding stress is exceeded during loading, the localized shearing in a fault zone will result in weakness with mean stresses in the fault becoming lower than those in the surrounding rock. It can be expected that such stress gradients will induce fluid flow towards the faults zone.

  • PDF