• Title/Summary/Keyword: McDonald

Search Result 167, Processing Time 0.039 seconds

In Sacco Ruminal Degradation Characteristics of Chemical Components in Fresh Zoysia japonica and Miscanthus sinensis Growing in Japanese Native Pasture

  • Ogura, S.;Kosako, T.;Hayashi, Y.;Dohi, H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.1
    • /
    • pp.41-47
    • /
    • 2001
  • Ruminal degradation characteristics of dry matter (DM), neutral detergent fiber (NDF) and crude protein (CP) in fresh leaves of two Japanese native grasses (Zoysia japonica and Miscanthus sinensis) and one sown temperate grass (Dactylis glomerata) were investigated by an in sacco method in spring (mid-May), summer (mid-July) and autumn (mid-September). Japanese native grasses had higher NDF and lower CP concentrations than D. glomerata, and the CP concentration in native grasses decreased in autumn. Ruminal degradability of DM, NDF and CP was lower in native grasses than in D. glomerata (p<0.05) in all seasons. DM and NDF degradability decreased in summer for Z. japonica and D. glomerata, while it decreased in autumn for M. sinensis. CP degradability in Z. japonica was constant throughout the seasons, whereas that in M. sinensis greatly decreased in summer and autumn (p<0.05). It was concluded that Z. japonica could stably supply ruminally digestible nutrients for grazing animals in Japanese native pasture. However, the degradation characteristics of freshly chopped native grasses did not fit the exponential model of $D=a+b(1-e^{-ct})$ proposed by Ørskov and McDonald.

IGRINS MIRROR MOUNT DESIGN FOR FIVE FLAT MIRRORS (다섯 개의 평면경을 위한 IGRINS 미러 마운트 설계)

  • Oh, Jae Sok;Park, Chan;Kim, Kang-Min;Chun, Moo-Young;Yuk, In-Soo;Oh, Heeyoung;Jeong, Ueejeong;Yu, Young Sam;Lee, Hanshin;Lee, Sungho
    • Publications of The Korean Astronomical Society
    • /
    • v.30 no.1
    • /
    • pp.17-29
    • /
    • 2015
  • The IGRINS is a near infrared high resolution spectrograph jointly developed by the Korea Astronomy and Space Science Institute and the University of Texas at Austin. We present design and fabrication of the optomechanical mount for the five mirrors, i.e., an input fold mirror, a slit mirror, a dichroic, and two camera fold mirrors. Based on the structure analysis and the thermal analysis of finite element methods, the optomechanical mount scheme satisfies the mechanical and the thermal design requirements given by the optical tolerance analysis. The performance of the fabricated mirror mounts has been verified through three IGRINS commissioning runs.

IGRINS Mirror Mount Design for Five Flat Mirrors

  • Oh, Jae Sok;Park, Chan;Kim, Kang-Min;Chun, Moo-Young;Yuk, In-Soo;Yu, Young Sam;Oh, Heeyoung;Jeong, Ueejeong;Lee, Hanshin;Jaffe, Daniel T.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.91.2-91.2
    • /
    • 2014
  • A near infrared wide-band high resolution spectrograph, immersion grating infrared spectrometer (IGRINS) has been jointly developed by the Korea Astronomy and Space Science Institute and the University of Texas at Austin. The compact white-pupil design of the instrument optics includes five cryogenic flat mirrors including a slit mirror, an input fold mirror, a dichroic mirror, and H&K camera fold mirrors. In this study, we introduce the optomechanical mount designs of the five cryogenic mirrors. In order to meet the structural stability and thermal requirements of the mount models, we conducted the design work with the aid of 3-dimensional computer modeling and the finite element analysis (FEA) method. We also present the actual fabricated parts and assemblies of the mounts and mirrors as well as their CAD models.

  • PDF

Correlation between galaxy mergers and AGN activity

  • Hong, Ju-Eun;Im, Myung-Shin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.1
    • /
    • pp.47.2-47.2
    • /
    • 2012
  • Using deep images taken at Maidanak 1.5m telescope, at McDonald 2.1m telescope and Canada-France-Hawaii Telescope, Dupont 2.5m telescope we investigated the fraction of merging galaxies in hosts of 39 AGN which are brighter than M = -22 mag and nearer than z = 0.3. We found that 16 to 17 of 39 AGN host galaxies show the evidence of mergers like tidal tail, shell via careful visual inspection. We also studied with the merging fraction of a control sample, SDSS Stripe82 early type galaxies of which surface brightness limit and bulge magnitude are similar to that of the AGN sample. We found that merging fraction of the AGN sample is higher than that of early type galaxy samples in the whole range of bulge magnitude. This result implies that AGN activity may be correlated with merging. We also investigated the detailed morphology of merging feature. At least - 1/4 of control samples classified as a tidal and tidal+dust are shell structures. On the other hand only one (5.9%) of AGN sample classified as merger shows shell structures, and almost all merging AGNs show tidal tail features. From point of view that tidal tail may be at the early stage of merging, and shell may be at the late stage of mergers, this result suggests that AGN might be evolved into early-type galaxies after merging.

  • PDF

Photometric Reverberation Mapping of Active Galactic Nuclei with Medium-band Filters and a Large FOV Telescope.

  • Hwang, Sungyong;Im, Myungshin;Ji, Tae-Geun;Lee, Hye-In;Pak, Soojong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.2
    • /
    • pp.78.1-78.1
    • /
    • 2017
  • We present a noble method to determine BH mass of many AGNs directly through reverberation mapping using a small telescope with wide-field of view. In 2017 August we installed five medium-band filters to a 0.25m diameter $5deg^2$ FOV telescope at the McDonald observatory. The width of these filters (FWHM ~ 50nm) are matched to the broad line width of type-1 AGNs at various redshifts. From recently obtained data, about r ~ 19 magnitude AGNs can be detected in line component with 150s exposure. With this magnitude limit, about 20~30 AGNs can be studied in one field. We plan to carry out at one day cadence observation over 20~30 fields, enabling us to monitor up to ~1000 AGNs over a wide range of variability. This poster presents out plan and early results from test observation.

  • PDF

Design of Linear Astigmatism Free Three Mirror System (LAF-TMS) for Sky Monitoring Programs

  • Park, Woojin;Pak, Soojong;Chang, Seunghyuk;Kim, Sanghyuk;Kim, Dae Wook;Lee, Hanshin;Lee, Kwangjo
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.2
    • /
    • pp.88.1-88.1
    • /
    • 2017
  • We report a novel design of the "linear astigmatism-free" three mirror system (LAF-TMS). In general, the linear astigmatism is one of the most dominant aberration degrading image qualities in common off-axis systems. The proposed LAF-TMS is based on a confocal off-axis three mirror system, where higher order aberrations are minimized via our numerical optimization. The system comprises three pieces of aluminum-alloy freeform mirrors that are feasible to be fabricated with current single-point diamond turning (SPDT) machining technology. The surface figures, dimensions, and positions of mirrors are carefully optimized for a LAF performance. For higher precision-positioning mechanism, we also included alignment parts: shims (for tilting) and L-brackets (for decentering). Any possible mechanical deformation due to assembly process as well as 1-G gravity, and its influence on optical performances of the system are investigated via the finite element (FE) analysis. The LAF-TMS has low f-number and a wide field of view, which is promising for sky monitoring programs such as supernova surveys.

  • PDF

Factors Associated with Underscreening for Cervical Cancer among Women in Canada

  • Schoueri-Mychasiw, Nour;McDonald, Paul Wesley
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.11
    • /
    • pp.6445-6450
    • /
    • 2013
  • Background: Cervical cancer is the second most common cancer among women worldwide. Failure to prevent cervical cancer is partly due to non-participation in regular screening. It is important to plan and develop screening programs directed towards underscreened women. In order to identify the factors associated with underscreening for cervical cancer among women, this study examined Pap test participation and factors associated with not having a time-appropriate (within 3 years) Pap test among a representative sample of women in Ontario, Canada using Canadian Community Health Survey (CCHS) data. Materials and Methods: Univariate analyses, cross-tabulations, and logistic regression modeling were conducted using cross-sectional data from the 2007-2008 CCHS. Analyses were restricted to 13,549 sexually active women aged 18-69 years old living in Ontario, with no history of hysterectomy. Results: Almost 17% of women reported they had not had a time-appropriate Pap test. Not having a time-appropriate Pap test was associated with being 40-69 years old, single, having low education and income, not having a regular doctor, being of Asian (Chinese, South Asian, other Asian) cultural background, less than excellent health, and being a recent immigrant. Conclusions: Results indicate that disparities still exist in terms of who is participating in cervical cancer screening. It is crucial to develop and implement cervical cancer screening programs that not only target the general population, but also those who are less likely to obtain a Pap tests.

A Study on The Sound Transmission Properties of Sound-Structure Interaction Plate Structure (구조-음향 연성 평판 구조물의 음향전달 특성에 관한 연구)

  • 오재응;이동익;조준호;송재은;도중석
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.56-61
    • /
    • 1995
  • 많은 공학자들은 기계 재료의 종류 및 형태에 따른 정적, 동적 특성 연구를 수행해 왔다. 특히 산업적으로 그 활용도가 높은 평판 재료에 대한 진동 특성 연구는 많이 이루어졌다. 최근에는 진동 특성을 해석하는 방법도 부분구조합성법, 감도해석법 등의 방법으로 연구가 활발히 이루어지고 있다. 한편 평판의 진동이 공기와 같은 매질로 상호 작용을 하며, 막힘이 없는 공간으로 음향을 방사하는 현상에 대한 연구도 이루어지고 있다. 그러나 평판 재료를 사용하여 기계 구조물을 제작하는 경우 많은 경우에 구조물간 결합에 의해 폐공간이 형성되고 이러한 폐공간에 의해 평판의 진동이 구조-음향 연성 현상이 발생되고, 이에 따라 평판의 진동 특성도 달라지게 된다. 이러한 구조-음향 연성에 대한 연구는 1978년 Wayne B.McDonald와 C.Kearney Barton, 1979년 R.Vaicatis에 의해 폐공간 내로의 음향 전달 현상을 연구하며 이루어졌다. 최근에 연구 동향은 이장명의 FEM과 BEM을 이용한 폐공간 내로의 음향 전달 현상을 연구하였고, V.B.Bokil에 의해 구조-음향 연성된 평판의 모드 해석 방법이 연구되었다. 한편 V.Martin에 의해 능동 소음 제어의 모델링을 좀더 정확히 하기 위해 구조 연성계를 고려한 연구도 수행되었다. 연구 결과 구조-음향 연성에 의한 평판의 고유진동수 변화를 구하였고 이 때에 경계조건을 만족하는 직교다항식을 이용한 Rayleigh-Ritz 방법을 이용하였다. 또한 이러한 해석은 실험과도 매우 잘 일치함을 알 수 있었다.

  • PDF

PROTO-MODEL OF AN INFRARED WIDE-FIELD OFF-AXIS TELESCOPE

  • Kim, Sang-Hyuk;Pak, Soo-Jong;Chang, Seung-Hyuk;Kim, Geon-Hee;Yang, Sun-Choel;Kim, Myung-Sang;Lee, Sung-Ho;Lee, Han-Shin
    • Journal of The Korean Astronomical Society
    • /
    • v.43 no.5
    • /
    • pp.169-181
    • /
    • 2010
  • We develop a proto-model of an off-axis reflective telescope for infrared wide-field observations based on the design of Schwarzschild-Chang type telescope. With only two mirrors, this design achieves an entrance pupil diameter of 50 mm and an effective focal length of 100 mm. We can apply this design to a mid-infrared telescope with a field of view of $8^{\circ}{\times}8^{\circ}$. In spite of the substantial advantages of off-axis telescopes in the infrared compared to refractive or on-axis reflective telescopes, it is known to be difficult to align the mirrors in off-axis systems because of their asymmetric structures. Off-axis mirrors of our telescope are manufactured at the Korea Basic Science Institute (KBSI). We analyze the fabricated mirror surfaces by fitting polynomial functions to the measured data. We accomplish alignment of this two-mirror off-axis system using a ray tracing method. A simple imaging test is performed to compare a pinhole image with a simulated prediction.

Software Design of CQUEAN

  • Jeong, Hyeon-Ju;Park, Won-Kee;Kim, Eun-Bin;Choi, Chang-Su;Pak, Soo-Jong;Im, Myung-Shin;Kim, Jung-Hoon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.39.1-39.1
    • /
    • 2010
  • We are developing a CCD camera named CQUEAN (Camera for Quasars in Early Universe) to search for quasars at z > 7. CQUEAN has a 1024*1024 deep depletion CCD chip and will be attached to 2.1m Otto-Struve Telescope at McDonald Observatory, USA. Although commercial software for the CCD camera is provided by the vendor, we are going to develop our own software to control the other instruments as well, to carry out efficient observation. There are four major parts in our software: Instrument control part controls the camera and filter wheel to obtain imaging data. Quick look window is to display acquired imaging data for quick inspection. Telescope control part interfaces with Telescope Control System (TCS) to move the telescope and to get time or coordinate information. Finally, Observation scripting facility part carries out a series of short exposures in a batch. The whole software will be written in python on linux platform, using the instrument control software libraries provided by the vendors.

  • PDF