• 제목/요약/키워드: Mc. Master

검색결과 230건 처리시간 0.022초

Novel Voltage Source Converter for 10 kV Class Motor Drives

  • Narimani, Mehdi;Wu, Bin;Zargari, Navid Reza
    • Journal of Power Electronics
    • /
    • 제16권5호
    • /
    • pp.1725-1734
    • /
    • 2016
  • This paper presents a novel seven-level (7L) voltage source converter for high-power medium-voltage applications. The proposed topology is an H-bridge connection of two nested neutral-point clamped (NNPC) converters and is referred to as an HNNPC converter. This converter exhibits advantageous features, such as operating over a wide range of output voltages, particularly for 10-15 kV applications, without the need to connect power semiconductors in series; high-quality output voltage; and fewer components relative to other classic seven-level topologies. A novel sinusoidal pulse width modulation technique is also developed for the proposed 7L-HNNPC converter to control flying capacitor voltages. One of the main features of the control strategy is the independent application of control to each arm of the converter to significantly reduce the complexity of the controller. The performance of the proposed converter is studied under different operating conditions via MATLAB/Simulink simulation, and its feasibility is evaluated experimentally on a scaled-down prototype converter.

Helper-Independent Live Recombinant Adenovirus Vector Expressing the Hemagglutinin-Esterase Membrane Glycoprotein

  • YOO, DONGWAN;ICK-DONG YOO;YOUNG-HO YOON;FRANK L GRAHAM;LORNE A. BABIUK
    • Journal of Microbiology and Biotechnology
    • /
    • 제2권3호
    • /
    • pp.174-182
    • /
    • 1992
  • The hemagglutinin-esterase glycoprotein (HE) gene of bovine coronavirus, coupled with a simian virus 40 early promoter and polyadenylation signal, was inserted into a human adenovirus transfer vector. The transfer vector was used to co-transfect 293 cells along with adenovirus genomic DNA. The hemagglutinin-esterase transcription unit was rescued into the adenovirus genome by homologous in vivo DNA recombination between the vector plasmid DNA and the adenovirus genomic DNA, and a recombinant adenovirus was isolated by several rounds of plaque assays. Thus the recombinant adenovirus carries the hemagglutinin-esterase gene in the early transcription region 3 (E3) of the adenovirus genome in the parallel orientation to the E3 transcription. The recombinant adenovirus synthesized the HE polypeptide in HeLa cells as demonstrated by immunoprecipitation with anti-coronavirus rabbit antisera. The recombinant HE polypeptide could be labelled by $[^3H]$glucosamine, demonstrating that the recombinant HE was glycosylated. Cells expressing the HE polypeptide exhibited hemadsorption activity when incubated with mouse erythrocytes. The HE was transported to the plasma membrane as shown by the cell surface immunofluorescence, indicating that the recombinant HE polypeptide retained its biological activities. Potential for the use of infectious recombinant adenovirus as a live virus-vectored vaccine candidate for bovine coronavirus disease is discussed.

  • PDF

연충감염우에 있어서 충란검사(蟲卵檢査)에 의한 구충효능(驅蟲效能) 평가방법(評價方法)에 관한 연구(硏究) (Studies on Evaluation Techniques of Anthelmintic Efficacy by Fecal Egg Counts in Cattle Naturally Infected with Helminths)

  • 지차호;장두환;윤희정
    • 대한수의학회지
    • /
    • 제24권1호
    • /
    • pp.83-90
    • /
    • 1984
  • In the evaluation of anthelmintic efficacy by fecal egg counts for cattle naturally infected with helminths, the reasonable technique of fecal egg counts and the reliable guidelines were determined as follows; 1. Modified technique of Harashigeru and Kim's sedimental tube was the most reasonable in fluke egg counts. 2. Universal egg counting technique was preciser than McMaster egg counting technique and was lower in coefficient variation. 3. Fecal egg counts of pretreatment should be carried out twice and mean of the epg should be calculated. 4. Fecal egg counts of posttreatment should be carried out 3 times and established at suitable intervals in consideration of anthelmintic mechanism and withdrawal days of anthelmintics. 5. If nematodal eggs are not found by UECT in posttreatment, direct flotation method should be carried out. And if positive, this epg was calculated at 20 (factor of UECT; $40{\times}1/2$).

  • PDF

Obesity as a Possible Risk Factor for Lost-time Injury in Registered Nurses: A Literature Review

  • Jordan, Gillian;Nowrouzi-Kia, Behnam;Gohar, Basem;Nowrouzi, Behdin
    • Safety and Health at Work
    • /
    • 제6권1호
    • /
    • pp.1-8
    • /
    • 2015
  • Time-loss injuries are still a major occurrence in Canada, injuring thousands of Canadian workers each year. With obesity rates on the rise across the country, as well as around the world, it is important that the possible effects of obesity in the workplace be fully understood, especially those effects linked to lost-time injuries. The aim of this paper was to evaluate predictors of workplace lost-time injuries and how they may be related to obesity or high body mass index by examining factors associated with lost-time injuries in the health care sector, a well-studied industry with the highest number of reported time loss injuries in Canada. A literature review focusing on lost-time injuries in Registered Nurses (RNs) was conducted using the keywords and terms: lost time injury, workers' compensation, occupational injury, workplace injury, injury, injuries, work, workplace, occupational, nurse, registered nurse, RN, health care, predictors, risk factors, risk, risks, cause, causes, obese, obesity, and body mass index. Data on predictors or factors associated with lost-time injuries in RNs were gathered and organized using Loisel's Work Disability Prevention Management Model and extrapolated upon using existing literature surrounding obesity in the Canadian workplace.

추나요법과 경근첩대요법이 내반슬 교정치료에 미치는 효과 (The Effect of Chuna Manual and Taping Treatment on Genu Varum)

  • 김경석;이종수
    • 한방재활의학과학회지
    • /
    • 제20권3호
    • /
    • pp.93-107
    • /
    • 2010
  • Objectives : The purpose of this study was to assess the efficacy of Chuna and taping treatment in patients with genu varum. Methods : Twenty-seven patients(male:10, female:17) with genu varum were recruited in this study. Chuna treatment at pelvic, and taping treatment at both legs were applied to whole participants. Outcomes were assessed using Q-angle(Quadriceps angle, QA), tibiofemoral angle(TFA), width and length of lesser trochanter(LT), pelvic incidence(PI), pelvic(PT), sacral slope(SS), lumber lordosis angle(LLA), meridian-electromyography(MEMG), Korean western ontario and McMaster universities osteoarthritis index(KWOMAC), and distance of femoral intercondylar distance(ICD). Results : 1. QA, LT width and LT length in radiograph were significantly increased. 2. PI, SS, PT and TFA in radiograph were significantly decreased. 3. The left vastus medialis portion contraction of female was significantly decreased after treatment. 4. The left rectus femoris portion fatigue was significantly decreased after treatment in male subjects. 5. The vastus medialis portion fatigue was significantly decreased after treatment in female subjects. 6. The distance of femoral ICD was significantly decreased. Conclusions : This study showed that Chuna and taping treatment could be used as an effective method for the treatment of genu varum.

반도체 소자용 자동 Die Bonder 기계장치의 개발 (Development of Die Bonder Machine for Semiconductor Automatic Assembly)

  • 변증남;윤명중;오상록;오영석;서일홍;안태영;권구빈;김제옥;김정덕
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 전기.전자공학 학술대회 논문집(I)
    • /
    • pp.284-287
    • /
    • 1987
  • In this paper, the design and implementation of a multiprocessor based Die Bonder Machine for the semiconductor will be described. This the partial research result, that is, the 1st year portion of the project to be performed for a period of two years from June, 1986 to May, 1988. The mechanical system consists of the following three subsystems : (i) transfer head unit, (ii) die feeding XY-table unit, and (iii) plunge up unit. The overall control system is designed to be essentially a master-slave type in which each slave is functionally fixed in view of software and also the time shared common bus structure with hardwired bus arbitration scheme is utilized, the control system consists of the following three subsystems each of which employs a 16 bits microprocessor MC 68000 : (i) die bonder processor controller, (ii) visual recognition/inspection and display system, (iii) the servo control system. It is reported that the proposed control system were applied to Working Sample and tested in real system, and the results are successful as a working sample phase.

  • PDF

Flexural behavior of steel storage rack base-plate upright connections with concentric anchor bolts

  • Zhao, Xianzhong;Huang, Zhaoqi;Wang, Yue;Sivakumaran, Ken S.
    • Steel and Composite Structures
    • /
    • 제33권3호
    • /
    • pp.357-373
    • /
    • 2019
  • Steel storage racks are slender structures whose overall behavior and the capacity depend largely on the flexural behavior of the base-plate to upright connections and on the behavior of beam-to-column connections. The base-plate upright connection assembly details, anchor bolt position in particular, associated with the high-rise steel storage racks differ from those of normal height steel storage racks. Since flexural behavior of high-rise rack base connection is hitherto unavailable, this investigation experimentally establishes the flexural behavior of base-plate upright connections of high-rise steel storage racks. This investigation used an enhanced test setup and considered nine groups of three identical tests to investigate the influence of factors such as axial load, base plate thickness, anchor bolt size, bracket length, and upright thickness. The test observations show that the base-plate assembly may significantly influence the overall behavior of such connections. A rigid plate analytical model and an elastic plate analytical model for the overall rotations stiffness of base-plate upright connections with concentric anchor bolts were constructed, and were found to give better predictions of the initial stiffness of such connections. Analytical model based parametric studies highlight and quantify the interplay of components and provide a means for efficient maximization of overall rotational stiffness of concentrically anchor bolted high-rise rack base-plate upright connections.

만성 골관절염 노인을 위한 지역사회 간호사 주도 복합운동 프로그램의 효과 (Effect of Nurse-led Community Comprehensive Exercise Program for Elderly with Chronic Osteoarthritis)

  • 백희정;임원지
    • 가정∙방문간호학회지
    • /
    • 제26권1호
    • /
    • pp.102-110
    • /
    • 2019
  • Purpose: This study aimed to investigate the effects of a nurse-led community comprehensive exercise program on the body composition, physical function, and health-related quality of life in elderly patients with osteoporosis. Method: The study was conducted with one group pretest-posttest design. A total of 57 elderly patients participated in 8 weeks of intervention. Data was analyzed with the SPSS ver. 23.0 using descriptive statistics and paired t-test. Results: At the end of the intervention, body mass index was significantly increased (t=2.93, p=.005), but right leg balance (t=2.40, p=.02) was significantly improved. In addition, the total Korean-Western Ontario and McMaster Universities Osteoarthritis Index (K-WOMAC) (t=3.48, p=.001), knee pain (t=2.61, p=.012), stiffness (t=2.53, p=.014), and physical function (t=3.51, p=.001) were significantly decreased. EuroQoL Visual Analogue Scale (EQ-VAS) scores (t=4.25, p<.001) were significantly improved. Conclusion: The nurse-led eight-week community comprehensive exercise program did not show desirable change in the body composition but was effective on the physical function and health-related quality of life for older people with osteoartritis.

Inactivation of Escherichia coli and MS2 coliphage by Cu(II)-activated peroxomonosulfate in natural water

  • Kim, Hyung-Eun;Lee, Hye-Jin;Kim, Min Sik;Choi, Joon-Young;Lee, Changha
    • Membrane and Water Treatment
    • /
    • 제10권3호
    • /
    • pp.231-237
    • /
    • 2019
  • Peroxymonosulfate (PMS) in combination with Cu(II) was examined to inactivate E. coli and MS2 coliphage in natural water. The combined system (i.e., the Cu(II)/PMS system) caused a synergistic inactivation of E. coli and MS2, in contrast with either Cu(II) or PMS alone. Increasing the concentration of PMS enhanced the inactivation of E. coli and MS2, but after a certain point, it decreased the efficacy of the microbial inactivation. In the Cu(II)/PMS system, adding reactive oxidant scavengers marginally affected the E. coli inactivation, but the inhibitory effects of copper-chelating agents were significant. Fluorescent assays indicated that the Cu(II)/PMS system greatly increased the level of reactive oxidants inside the E. coli cells. The sequential addition of Cu(II) and PMS inactivated more E. coli than did adding the two simultaneously; in particular, the inactivation efficacy was much higher when Cu(II) was added first. The observations from the study collectively showed that the microbial inactivation by the Cu(II)/PMS system could be attributed to the toxicity of Cu(I) as well as the intracellular oxidative stress induced by Cu(III) or radical species.

Sorption of Np(IV) on MX-80 in Ca-Na-Cl Type Reference Water of Crystalline Rock

  • Nagasaki, Shinya
    • 방사성폐기물학회지
    • /
    • 제19권1호
    • /
    • pp.1-7
    • /
    • 2021
  • The pH dependence of sorption distribution coefficient (Kd) of Np(IV) on MX-80 in Ca-Na-Cl type solution with the ionic strength of 0.3 M, which was similar to one of the reference groundwaters in crystalline rock, was experimentally investigated under the reducing conditions. The overall trend of Kd on MX-80 was independent of pH at 5 ≤ pH ≤ 10 but increased as pH increased at pH ≤ 5. The 2-site protolysis non-electrostatic surface complexation and cation exchange model was applied to the experimentally measured pH dependence of Kd and the optimized surface complexation constants of Np(IV) sorption on MX-80 were estimated. The values of surface complexation constants in this work agreed relatively well with those in the Na-Ca-Cl solution previously evaluated, suggesting that compared to Na+, the competition of Ca2+ with Np(IV) for surface complexation on MX-80 was not much strong in Ca-Na-Cl solution. The sorption model well predicted the pH dependence of Kd values but slightly overestimated the sorption at the low pH region.