• Title/Summary/Keyword: Maze procedure

Search Result 46, Processing Time 0.02 seconds

The Cox-Maze Procedure for Atrial Fibrillation not Associated with Mitral Valve Disease -Report of three cases- (승모판막질환을 동반하지 않은 심방세동에서의 Cox-Maze 술식 -3례 보고-)

  • 강창현;김기봉
    • Journal of Chest Surgery
    • /
    • v.31 no.12
    • /
    • pp.1230-1233
    • /
    • 1998
  • The Cox-Maze procedure was developed as a cure for atrial fibrillation. The recovery rate of both atrial contractility is reported low in the atrial fibrillation associated with mitral valvular heart disease than that of loan atrial fibrillation. We performed the Cox-Maze procedure (Maze III) in three cases who suffered from non-mitral heart diseases associated with atrial fibrillation: A ruptured sinus of Valsalva aneurysm, a ventricular septal defect, and an aortic stenoinsufficiency. The Cox-Maze procedure was performed concomitantly with correction of the underlying heart disease. Conversion to sinus rhythm was achieved in all three patients, and both right and left atrial mechanical activities could be identified echocardiographically after three postoperative months.

  • PDF

Surgical Outcomes of Cox-maze IV Procedure Using Bipolar Irrigated Radiofrequency Ablation and Cryothermy in Valvular Heart Disease

  • Kim, Jun-Sung;Lee, Jae-Hang;Chang, Hyoung-Woo;Kim, Kyung-Hwan
    • Journal of Chest Surgery
    • /
    • v.44 no.1
    • /
    • pp.18-24
    • /
    • 2011
  • Background: We evaluated the efficacy of Cox-maze IV procedure using bipolar irrigated radiofrequency ablation and cryothermy in chronic atrial fibrillation associated with valvular heart disease. Material and Methods: From November 2005 to June 2009, ninety four patients have undergone valvular heart surgery with Cox-maze IV procedure. Preoperative duration of atrial fibrillation was $7.6{\pm}6.5$ years and follow-up duration was $22.7{\pm}12.3$ months. Results: There were two (2.1%) postoperative deaths not related to maze procedure. Two cerebrovascular accidents, five low cardiac output syndromes and two permanent pacemaker implantations have occurred after surgery. Preoperative ejection fraction on echocardiography was $55.3{\pm}8.1%$ and ejection fraction of postoperative six month was $54.7{\pm}6.5%$. Left atrial size of preoperative and postoperative were $61.5{\pm}11.6\;mm$ and $53.1{\pm}8.4\;mm$ at each. Freedom from atrial fibrillation rate at postoperative six-month was 80.7% and the cases of recurrence of atrial fibrillation after six months were three (3.3%). Risk factors for failure or recurrence of maze procedure were old age (p=.010) and preoperative moderate or severe tricuspid regurgitation (p=.033). Conclusion: The Cox-maze IV procedure using RFBP2 and cryothermy is quite safe and freedom from atrial fibrillation at postoperative 6 month was 82.5%. Risk factors for failure or recurrence of atrial fibrillation after Cox-maze IV were old age and preoperative over moderate tricuspid regurgitation.

Modification of the Cox-Maze Procedure for Atrial Fibrillation with Large Left Atrium ; Development of Surgical Technique to Increase the Left Atrial Contractility (좌심방 확장을 동반한 심방세동에 대한 Cox-Maze 수술법의 변형 -수술후 좌심방 수축력의 증진을 위한 수술법의 개량-)

  • 강창현;김기봉;손대원
    • Journal of Chest Surgery
    • /
    • v.32 no.3
    • /
    • pp.249-254
    • /
    • 1999
  • Background: Recovery of the left atrial contractile function after the Cox-Maze procedure is related to the size of the left atrium. We have postulated that if too wide area of the atrium were isolated electrically, then the atrial contractile function would be impaired postoperatively. We have modified the Cox-Maze procedure to dissect each pair of the pulmonary veins separately instead of the conventional pulmonary vein encircling incision, and compared the atrial contractile function after each procedure. Material and Method: From February 1995 to October 1997, 55 cases of the Cox-Maze procedure were performed in mitral valvular heart disease. We excluded the cases that did not covert to sinus rhythm. The patient groups were divided according to the interpulmonary vein distance(IPVD) and the procedure performed. Group I was IPVD under 6.5 cm(n=30), group II was IPVD over 6.5cm and the conventional Cox-Maze III procedure was performed(n=16), and group III was IPVD over 6.5cm and the modified Cox-Maze procedure was performed(n=9). Result: Atrial contractile function was evaluated by the echocardiography follow-up between 6 months to 12 months. The right atrial contractile function recovered gradually, the recovery rate after long-term follow-up was 90% in group I, 81% in group II, and 100% in group III(p>0/05). In the left atrium the recovery rate was 63% in group I, 31% in group II(p=0.03), and 66% in group III(p>0.05). Conclusion: The modified Cox-Maze procedure may have beneficial effects on the recovery of the left atrial contractile function, however, there are no statistically significant values. Therefore, further evaluation of this procedure is necessary.

  • PDF

The Influence of Simplified Surgical Procedures on the Surgical Treatment for Atrial Fibrillation with using the Cut-and-Sew Technique (절개봉합법을 이용한 심방세동 수술의 중단기 결과)

  • Choi, Jong-Bum;Kim, Jong-Hun;Lee, Mi-Kyung;Lee, Sam-Youn;Kim, Min-Ho;Kim, Kong-Su
    • Journal of Chest Surgery
    • /
    • v.41 no.3
    • /
    • pp.313-319
    • /
    • 2008
  • Background: The Cox maze-III procedure is considered as the most effective surgical treatment for atrial fibrillation. Because this procedure takes a long time and it complicates the concomitant cardiac surgery, some surgeons perform a left atrial maze procedure or pulmonary vein isolation only to reduce the operation time. This study was performed to evaluate how the modified procedures, with using cut-and-sew techniques, can influence the treatment of atrial fibrillation. Material and Method: Between Feb 1999 and June 2005, 40 patients (17 males and 23 females) with organic heart disease and atrial fibrillation underwent the Cox maze-III procedure (23), the left atrial maze procedure (10) or pulmonary vein isolation (7). The cut-an-sew technique was used to ablate the atrial wall, but cryoablation was used instead of the cut-and-sew technique for the coronary sinus and the inferior wall between the pulmonary vein and the mitral annulus. Result: After a mean follow-up period of $50.0{\pm}21.6$ months, all (100%) of the 23 patients who underwent the Cox maze-III procedure had regular sinus or atrial rhythm conversion, and 7(70%) of 10 with a left atrial maze procedure and 4(57.1%) of 7 with pulmonary vein isolation had regular sinus or atrial rhythm conversion (p=0.002). Conclusion: To obtain a high conversion rate from atrial fibrillation to a regular sinus rhythm or a regular atrial rhythm, the standard Cox maze-III procedure should be performed in both atria. The limited modified procedures like the left atrial maze procedure or pulmonary vein isolation may reduce the cure rate of atrial fibrillation.

An Experience of Cox-maze III Procedure for Chronic Atrial Fibrillation (만성 심방세동에 대한 Cox-maze III 수술의 임상경험)

  • 김삼현;박이태;서필원;박성식;류재욱;최창휴;김명아;이명용;김영권
    • Journal of Chest Surgery
    • /
    • v.31 no.7
    • /
    • pp.668-673
    • /
    • 1998
  • During the past several years, the maze operation has become the most effective method of treatment for chronic atrial fibrillation. When the maze procedure is done concomittantly with other cardiac operations, surgeons, in their initial experiences, may be concerned about the additional operative risks and uncertainty of the results. We performed the Cox-maze III procedure in six cases of chronic atrial fibrillation associated with mitral, mitral & aortic, or coronary arterial disease. Maze III procedure was done with open mitral commissurotomy(3 cases), mitral valve replacement(1 case), aortic and mitral valve replacement(1 case), and two-vessel coronary bypass graft(1 case). In spite of rather prolonged aortic cross clamp time, cardiac recovery was uneventful in all cases. No cases required reexploration for postoperative bleeding. All patients showed regular sinus rhythms immediate or between 2 and 20 days postoperateratively. Transient postoperative supraventricular arrhythmarias were easily controlled by various antiarrhythmic agents. In follow up evaluations, all cases showed regular sinus rhythm on ECG and the right and left atrial transport function was confirmed by Doppler echocardiography in all except one. Though our experience was limited in case number, the Cox-maze III procedure was effective in controlling the chronic atrial fibrillation without serious additional operative risks.

  • PDF

Result of Cox Maze Procedure with Bipolar Radiofrequency Electrode and Cryoablator for Persistent Atrial Fibrillation - Compared with Cut-sew Technique - (양극고주파전극과 냉동프로브를 이용한 지속성 심방세동의 수술 결과 - 절개/봉합술식과 비교 -)

  • Lee, Mi-Kyung;Choi, Jong-Bum;Lee, Jung-Moon;Kim, Kyung-Hwa;Kim, Min-Ho
    • Journal of Chest Surgery
    • /
    • v.42 no.6
    • /
    • pp.710-718
    • /
    • 2009
  • Background: The Cox maze procedure has been used as a standard surgical treatment for atrial fibrillation for about 20 years. Recently, the creators have used a bipolar radiofrequency electrode (Cox maze IV procedure) instead of the incision and suture (cut-sew) technique to make atrial ablation lesions for persistent atrial fibrillation. We investigated clinical outcomes for the Cox maze procedure with a bipolar radiofrequency electrode and cryoablator in patients with persistent atrial fibrillation, and compared results with clinical outcomes of the cut-sew procedure. Material and Method: Between April 2005 and July 2007, 40 patients with persistent atrial fibrillation underwent Cox maze IV procedure with a bipolar radiofrequency electrode and cryoablator (bipolar radiofrequency group). Surgical outcomes were compared with those of 35 patients who had the cut-sew technique for the Cox maze III procedure. All patients had concomitant cardiac surgery. Postoperatively, the patients were followed up every 1 to 2 months. Result: At 6 months postoperatively, the conversion rate to regular sinus rhythm was not significantly different between the two groups: 95.0% for the bipolar radiofrequency ablation group; 97.1% for the cut-sew technique (p=1.0). At the end of the follow-up period, the conversion rate to regular sinus rhythm was also not significantly different (92.5% vs. 91.6%, p=1.0). In multivariate analysis using a Cox-regression model, the postoperative atrial dimension was an independent determinant of sinus conversion in the bipolar radiofrequency ablation group (hazard ratio 31, p=0.005). In the Cox-regression model for both groups, atrial fibrillation at 6 months postoperatively (hazard ratio 92.24, p=0.003) and the postoperative left atrial dimension (hazard ratio 16.05, p=0.019) were independent risk factors of continuance or recurrence of atrial fibrillation after Cox maze procedures. Aortic cross-clamp time and cardiopulmonary bypass time were significantly shorter in the radiofrequency group than in the cut-sew group. Conclusion: In the Cox maze procedure for patients with persistent atrial fibrillation, the use of bipolar radiofrequency ablation and a cryoablator is as good as the cut-sew technique for conversion to sinus rhythm. The postoperative left atrial dimension is an independent determinant of postoperative continuance and recurrence of atrial fibrillation.

Is It Safe to Preserve Left Atrial Appendage During Maze Procedure?

  • Kyungsub Song;Woo Sung Jang;Namhee Park;Yun Seok Kim;Jae Bum Kim
    • Korean Circulation Journal
    • /
    • v.53 no.8
    • /
    • pp.566-577
    • /
    • 2023
  • Background and Objectives: The left atrial appendage (LAA) can contribute significantly to LA mechanical contraction. Nevertheless, the preventive effect of LAA occlusion during the maze procedure against cerebral infarction remains controversial. In this study, we compared the surgical, cardiac hemodynamic, and neurologic outcomes between LAA preservation and occlusion performed during the maze procedure. Methods: Between January 2015 and August 2021, 252 patients underwent the maze procedure using cryoablation at our medical center. After excluding patients according to our exclusion criteria (i.e., mechanical prosthesis implantation, preexisting LAA thrombus), LAA was preserved in 113 patients (non-occlusion group) and occluded in 75 patients (occlusion group). Outcomes were compared using propensity score matching (PSM). Results: PSM did not reveal significant intergroup differences in baseline characteristics between the non-occlusion (n=53) and occlusion (n=53) groups. During a median follow-up of 44 months, 2 patients in the non-occlusion group (3.8%) experienced ischemic strokes. There was no significant difference in the rate of freedom from stroke (p=0.19) and major adverse cardiac events (p=0.43) between the 2 groups. Through echocardiography at 1-year follow-up, a statistically significant difference in LA mechanical contraction was observed between the non-occlusion group and occlusion group (24 of 33 [72.7%] vs. 18 of 37 [48.6%], respectively; p=0.04). Conclusions: In this study, preservation of the LAA during the maze procedure resulted in better LA function than LAA occlusion, with similar rates of stroke.

Outcome of Concomitant Cox Maze Procedure with Narrow Mazes and Left Atrial Volume Reduction

  • Choi, Jong Bum;Kim, Jong Hun;Cha, Byong Ki
    • Journal of Chest Surgery
    • /
    • v.47 no.4
    • /
    • pp.358-366
    • /
    • 2014
  • Background: To improve sinus rhythm conversion, the Cox maze III procedure with narrow mazes (width: ${\leq}3.0cm$) was performed in combination with left atrial volume reduction. Methods: From October 2007 to April 2013, 87 patients with atrial fibrillation (paroxysmal in 3, persistent in 14, and permanent in 70) underwent the Cox maze procedure concomitant with another cardiac procedure. They were followed-up with serial electrocardiographic and echocardiographic studies. We used 24-hour Holter monitoring tests to evaluate postoperatively symptomatic patients. Results: At the mean follow-up time of 36.4 months, 81 patients (94.2%) had sinus rhythm and two were on anti-arrhythmic medication (one on a beta-blocker and the other on amiodarone). Five patients (5.8%) with postoperative recurrent and persistent atrial fibrillation never experienced sinus rhythm conversion; however, they did not require any medication for rate control. On postoperative echocardiography, the left atrial A waves were more frequently observed after concomitant mitral valve repair than after concomitant mitral valve replacement (82.4% vs. 40.4%, respectively; p<0.001). Conclusion: For the Cox maze procedure, narrow mazes and atrial volume reduction resulted in excellent sinus rhythm conversion without the preventive use of anti-arrhythmic drugs, and they did not affect the presence of the left atrial A waves on echocardiography.

Efficacy of Cox Maze IV Procedure Using Argon-Based Cryoablation: A Comparative Study with $N_2O$-Based Cryoablation

  • Lee, Kyung-Hak;Min, Jooncheol;Kim, Kyung-Hwan;Hwang, Ho Young;Kim, Jun Sung
    • Journal of Chest Surgery
    • /
    • v.47 no.4
    • /
    • pp.367-372
    • /
    • 2014
  • Background: We compared the mid-term results of the Cox maze IV procedure using argon-based cryoablation with a procedure using $N_2O$-based cryoablation. Methods: From May 2006 to June 2012, 138 patients (mean age, $58.2{\pm}11.0$ years) underwent the Cox maze IV procedure. Eighty-five patients underwent the maze procedure using an $N_2O$-based cryoprobe (group N), and 53 patients underwent the maze procedure using an argon-based cryoprobe (group A). Bipolar radiofrequency ablation was concomitantly used in 131 patients. The presence of atrial fibrillation immediately, 6 months, 1 year, and 2 years after surgery was compared. Results: Early mortality occurred in 6 patients (4.3%). There were no differences in early mortality or postoperative complications between the two groups. Nineteen of 115 patients (16.5%) remained in atrial fibrillation at postoperative 12 months (14 of 80 patients (17.5%) in group N and 5 of 35 patients (14.3%) in group A, p=0.669). There were no differences in the number of patients who remained in atrial fibrillation at any of the time periods except in the immediate postoperative period. A multivariable analysis revealed that the energy source of cryoablation was not associated with the presence of atrial fibrillation at 1 year (p=0.862) and that a fine F wave (<0.1 mV) was the only risk factor predicting the presence of atrial fibrillation at 1 year (p<0.001, odds ratio=20.287). Conclusion: The Cox maze IV procedure using an argon-based cryoprobe was safe and effective compared with the maze procedure using an $N_2O$-based cryoprobe in terms of operative outcomes and the restoration of sinus rhythm for up to 2 years after surgery.

The Absence of Atrial Contraction as a Predictor of Permanent Pacemaker Implantation after Maze Procedure with Cryoablation

  • Jeon, Chang-Seok;Shim, Man-shik;Park, Seung-Jung;Jeong, Dong Seop;Park, Kyoung-Min;On, Young Keun;Kim, June Soo;Park, Pyo Won
    • Journal of Chest Surgery
    • /
    • v.50 no.3
    • /
    • pp.163-170
    • /
    • 2017
  • Background: The absence of atrial contraction (AC) after the maze procedure has been reported to cause subsequent annular dilatation and to increase the risk of embolic stroke. We hypothesized that the lack of AC could increase the risk of permanent pacemaker (PPM) implantation in patients undergoing the maze procedure. Methods: In 376 consecutive patients who had undergone a cryo-maze procedure and combined valve operation, recovery of AC was assessed at baseline and at immediate (${\leq}2$ weeks), early (${\leq}1$ year, $4.6{\pm}3.8$ months), and late (>1 year, $3.5{\pm}1.1$ years) postoperative stages. Results: With a median follow-up of 53 months, 10 patients underwent PPM implantation. Seven PPM implants were for sinus node dysfunction (pauses of $9.6{\pm}2.4$ seconds), one was for marked sinus bradycardia, and two were for advanced/complete atrioventricular block. The median (interquartile range) time to PPM implantation was 13.8 (0.5-68.2) months. Our time-varying covariate Cox models showed that the absence of AC was a risk factor for PPM implantation (hazard ratio, 11.92; 95% confidence interval, 2.52 to 56.45; p=0.002). Conclusion: The absence of AC may be associated with a subsequent risk of PPM implantation.