• 제목/요약/키워드: Maximum removal

검색결과 1,137건 처리시간 0.026초

Cobalt ferrite nanotubes and porous nanorods for dye removal

  • Girgis, E.;Adel, D.;Tharwat, C.;Attallah, O.;Rao, K.V.
    • Advances in nano research
    • /
    • 제3권2호
    • /
    • pp.111-121
    • /
    • 2015
  • $CoFe_2O_4$ nanotubes and porous nanorods were prepared via a simple one-pot template-free hydrothermal method and were used as an adsorbent for the removal of dye contaminants from water. The properties of the synthesized nanotubes and porous nanorods were characterized by electron diffraction, transmission electron microscopy and x-ray powder diffraction. The Adsorption characteristics of the $CoFe_2O_4$ were examined using polar red dye and the factors affecting adsorption, such as, initial dye concentration, pH and contact time were evaluated. The overall trend followed an increase of the sorption capacity reaching a maximum of 95% dye removal at low pHs of 2-4. An enhancement in the removal efficiency was also noticed upon increasing the contact time between dye molecules and $CoFe_2O_4$ nanoparticles. The final results indicated that the $CoFe_2O_4$ nanotubes and porous nanorods can be considered as an efficient low cost and recyclable adsorbent for dye removal with efficiency 94% for Cobalt ferrite nanotubes and for Cobalt ferrite porous nanorods equals 95%.

다중 모래 여재를 적용한 부분 포기 Biological Aerated Filter의 효과적인 Total Nitrogen (TN) 제거 (Effective Total Nitrogen (TN) Removal in Partially Aerated Biological Aerated Filter (BAF) with Dual Size Sand Media)

  • 강정희;송지현;하정협
    • 상하수도학회지
    • /
    • 제24권1호
    • /
    • pp.5-14
    • /
    • 2010
  • A pilot-scale biological aerated filter (BAF) was operated with an anaerobic, anoxic and oxic zone at $23{\pm}1^{\circ}C$. The influent sCOD and total nitrogen concentrations in the feedwater were approximately 250 mg/L and 35 mg N/L, respectively. sCOD removal at optimum hydraulic retention time (HRT) of 3 hours with recirculation rates of 100, 200 and 300% in the column was more than 96%. Total nitrogen removal was consistently above 80% for 4 and 6 hours HRT at 300% recirculation. For 3 hours HRT and 300% recirculation, total nitrogen removal was approximately 79%. Based on fitting results, the kinetic parameter values on nitrification and denitrification show that as recirculation rates increased, the rate of ammonia and nitrate transformation increased. The ammonium loading rates for maximum ammonium removed were 0.15 and 0.19 kg $NH_3$-N/$m^3$-day for 100% and 200% recirculation, respectively. The experimental results demonstrated that the BAF can be operated at an HRT of 3 hours with 200 - 300% recirculation rates with more than 96 % removal of sCOD and ammonium, and at least 75% removal of total nitrogen.

Removal of sulphate from landfill leachate by crystallization

  • Aygun, Ahmet;Dogan, Selim;Argun, Mehmet Emin;Ates, Havva
    • Environmental Engineering Research
    • /
    • 제24권1호
    • /
    • pp.24-30
    • /
    • 2019
  • The present study explores the applicability of response surface methodology (RSM) in conjunction with central composite design (CCD) matrix to statistically optimize ettringite crystallization process for the removal of sulphate from landfill leachate. A three factor-five coded level CCD with 20 runs, was performed to estimate the best fitted model. The RSM results indicated that the fitted quadratic regression model could be appropriate to predict sulfate removal efficiency. The pH was identified as the most dominant parameter affecting sulphate removal. 61.6% of maximum sulphate removal efficiency was obtained at pH of 11.06 for a 1.87 of $Ca/SO_4$ and 0.51 of $Al/SO_4$ molar ratios. The operating cost for ettringite crystallization at optimized conditions was calculated to be 0.52 $/$m^3$. The significance of independent variables and their interactions were tested by analysis of variance. Scanning electron microscope (SEM) and SEM coupled with energy dispersive X-Ray spectroscopy results confirmed the formation of ettringite crystal and were used to describe its morphology features.

간극에서의 역방향 유동 제한 현상 연구 (Counter-Current Flow Limit in Narrow Gap)

  • 김용훈;서균렬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1054-1060
    • /
    • 1998
  • Previous counter-current flow limitation (CCFL) and critical heat flux (CHF) studies included investigations on the inlet entrance, inclined channel and gap effects for the most part. In this study, the local CHF correlation was presented to be used in the numerical analysis for the 3 dimensional hemispherical geometry. Also, first-principle analyses were performed to determine the maximum heat removal capability from the debris through the gap that may be formed during a core melt accident. The maximum heat removal capability by gap cooling can be applied in quantitatively assessing the severe accident management measures.

  • PDF

펄스지속시간에 따른 형상방전가공 특성 (Characteristics of Die Sinking Electical Discharge Machining for Pulse Duration)

  • 우정윤;왕덕현;윤존도
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.827-831
    • /
    • 1997
  • Conductive veramic matrix composite(CMC) workpiece of TiC 33%/Al /sab 2/O /sab 3/ 66% Y /sab 2/ O /sab 3/ was machined by die sinking electrical discharge machining(EDM) according to different pulse duration and suty factor for reverse polarity of electrode. Material removal rate(MRR) was examined by process under various operating conditions. The surface morphology was evaluated by surface roughness values and scanning electron microscopy(SEM) research. The more MRR was obtained according to increase pulse duration and duty factor. Also the maximum surface roughness(Rmax) of EDMed surface was slightly changed with increased pulse duration and duty factor. The SEM photographs of EDMed surface showed wide recast wide recast distribution region of melting materials in purse duration 0.130(ms) than 0.048(ms).

  • PDF

Characteristics of arsenic sorption on furnace slag in groundwater

  • S. R. Kanel;Saurabh Sharma;Park, Hechul
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2002년도 추계학술발표회
    • /
    • pp.96-98
    • /
    • 2002
  • Furnace slag, a steel industry waste, has been converted into an inexpensive and efficient adsorbent. The product obtained has been utilized for the removal of arsenic from ground water. Kinetic studies have bepn described with the mechanism of adsorption The results from batch studies showed that the As(III) can be removed from the ground water within the pH range 3-7 However the maximum removal was experienced at pH 7.0. Equilibrium was attained within 24 hours. Adsorption data of arsenic correlate well with the Freundlich and Langmuir adsorption models. The maximum sorption capacity as calculated using Freundlich adsorption isotherm was found to be of 0.004 mg g-1 at pH 7 and $25^{\circ}C$.

  • PDF

간극에서의 역방향 유동 제한 현상 연구 (Counter-Current Flow Limit in Narrow Gap)

  • 김용훈;서균렬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.706-712
    • /
    • 1998
  • Previous counter-current flow limitation (CCFL) and critical heat flux (CHF) studies included investigations on the inlet entrance, inclined channel and gap effects for the most part. In this study, the local CHF correlation was presented to be used in the numerical analysis for the 3 dimensional hemispherical geometry. Also, first-principle analyses were performed to determine the maximum heat removal capability from the debris through the gap that may be formed during a core melt accident. The maximum heat removal capability by gap cooling can be applied in quantitatively assessing the severe accident management measures.

  • PDF

간극에서의 역방향 유동 제한 현상 연구 (Counter-Current Flow Limit in Narrow Gap)

  • 김용훈;서균렬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.386-392
    • /
    • 1998
  • Previous counter-current flow limitation (CCFL) and critical heat flux (CHF) studies included investigations on the inlet entrance, inclined channel and gap effects for the most part. In this study, the local CHF correlation was presented to be used in the numerical analysis for the 3 dimensional hemispherical geometry. Also, first-principle analyses were performed to determine the Maximum heat removal capability from the debris through the gap that may be formed during a core melt accident. The maximum heat removal capability by gap cooling can be applied in quantitatively assessing the severe accident management measures.

  • PDF

The Effect of the Mixture of Nonionic Surfactant and Bioactive Agent for Surfactant-enhanced Soil Flushing (SESF) of TCB Contaminated Soil

  • Lee, Dal-Heui;Cho, Heuy Nam;Chung, Sung-Lae
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제19권2호
    • /
    • pp.1-6
    • /
    • 2014
  • The objective of this study was to find the effect of the mixture of the nonionic surfactant and bioactive agent that solubilizes trichlorobenzene (TCB) present as a contaminant for surfactant-enhanced soil flushing (SESF). Three different nonionic surfactants and two different bioactive agents were obtained from four companies. Separate funnel experiments and shaker table agitation / centrifugation experiments were used for the test. Based on the separate funnel experimental results, three suitable mixture agents (APG + OSE, Brij 35 + MOSE, T-Maz 60 + MOSE) were selected. In the shaker table agitation / centrifugation experiments, these three different mixture agents were reduced to one (T-Maz 60 +MOSE). The maximum removal (95%) of TCB was obtained using a mixture of the nonionic surfactant and bioactive agent. Therefore, the used test methods and results can be used for SESF.

진공청소기 분진을 모델로 한 고형오염의 세척성에 관한 연구 (Studies on the Detergency of Particulate Soil using Vacuum Cleaner Dirt as Model)

  • 강인숙;김성련
    • 한국의류학회지
    • /
    • 제13권3호
    • /
    • pp.286-294
    • /
    • 1989
  • This Study has treated the effects of fiber, surfactants, temperature, surfactant concentration, pH, electrolyte, fatty acid contents and mechanical force on the removal of particulate soil from fabric, vacuum cleaner dirt was used as model particulate soil. The fabrics were soiled with mixture of vacuum cleaner dirt and fatty soil, and washed in Terg-O-tometer. The detergency was evaluated by measuring reflectance of a fabric before and after washing. The results were as follows. 1. The fiber type showed a different pattern of soil removal with surfactants. In general, particulate soil removal increased in the following order Acetate>PET. Nylon>Cotton. Particulate soil removal, which is affected by the surfactant type, increased in the following order NPE $(EO)_{10}\leqq$Soap>SLS>DBS>Tween 80. 2. The influence of temperature on the particulate soil removal was very complex because efficiency of removal was varied with surfactant and fiber types. The washing efficiency of NPE $(EO)_{10}$ was highest at around $40^{\circ}C\;and\;60^{\circ}C$ with cotton and PET but the washing efficiency of DBS was the highest at $60^{\circ}C$ with cotton, decreased monotonously with increasing temperature with PET 3. The detergency of particulate soil increased with increasing surfactant concentration at relatively low concentration and then levelled off above some optimum concentration. 4. The removal of particulate soil increased with increasing pH and mechanical force. 5. Effect of electrolyte on the particulate soil removal was depended on the concentration of the surfactant. At low concentration of surfactant, addition of electrolytes improved soil removal but above the some concentration no effect was observed. At high concentration of surfactant, Vie., $0.6\%$ , the maximum washing effect is reached without added electrolyte. These result indicate that added electrolyte only influence the adsorption of surfactant on the soil and fiber 6. Fatty acid content in the soil did not influence on particulate soil removal without regard to surfactants.

  • PDF