• 제목/요약/키워드: Maximum power coefficient

검색결과 331건 처리시간 0.028초

Study on Performance Improvement of an Axial Flow Hydraulic Turbine with a Collection Device

  • Nishi, Yasuyuki;Inagaki, Terumi;Li, Yanrong;Hirama, Sou;Kikuchi, Norio
    • International Journal of Fluid Machinery and Systems
    • /
    • 제9권1호
    • /
    • pp.47-55
    • /
    • 2016
  • The portable hydraulic turbine we previously developed for open channels comprises an axial flow runner with an appended collection device and a diffuser section. The output power of this hydraulic turbine was improved by catching and accelerating an open-channel water flow using the kinetic energy of the water. This study aimed to further improve the performance of the hydraulic turbine. Using numerical analysis, we examined the performances and flow fields of a single runner and a composite body consisting of the runner and collection device by varying the airfoil and number of blades. Consequently, the maximum values of input power coefficient of the Runner D composite body with two blades (which adopts the MEL031 airfoil and alters the blade angle) are equivalent to those of the composite body with two blades (MEL021 airfoil). We found that the Runner D composite body has the highest turbine efficiency and thus the largest power coefficient. Furthermore, the performance of the Runner D composite body calculated from the numerical analysis was verified experimentally in an open-channel water flow test.

ChlorophyII and suspended sediment specific absorption coefficient in the sea.

  • Ahn, Yu-Hwan;Moon, Jeong-Eon
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 1998년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.399-403
    • /
    • 1998
  • Absorption coefficient per mass unit of particles, specific absorption coefficient, is one of main parameters in developing algorithms for ocean color remote sensing. Specific absorption coefficient of chlorophyll (a$^*_{ph}$) and suspended sediment (SS) were analyzed by "wet filter technique" and "Kishino method" for data sets observed in the Yellow and Mediterranean Seas. A new data-recovering method for the filter technique was also developed using spectrum slopes. This method recovered the baseline of spectrum that was often missed in the Kishino method. High a$^*_{ph}$($\lambda$) values in the oligotrophic Mediterranean Sea and low values in the Yellow Sea were observed, spanning over the range of 0.02 to 0.12 $m^2$/mg, at the chlorophyll maximum absorption wavelength 440nm. The empirical relationship between a$^*_{ph}$ and chlorophyll concentration was found to fit a power function, which was slightly different from that proposed by Bricaud et ai. (1995). Absorption specific coefficients for suspended sediment (a$^*_{SS}$) didn't show any relationship with concentrations of suspended sediment. However, the average value of a$^*_{SS}$ at 440nm was close to the specific absorption coefficient of soil (loess) measured by Ahn (1990). The more-pronounced variability of a$^*_{SS}$ than a$^*_{ph}$ perhaps can explain more wide range of size-distribution for SS, which were determined by their specific gravity and agitation of water mass in the sea surface.

  • PDF

수직축 조류 터빈 발전효율 평가를 위한 유동-터빈 연동 CFD 해석 (I) (Flow-Turbine Interaction CFD Analysis for Performance Evaluation of Vertical Axis Tidal Current Turbines (I))

  • 이진학;오상호;박진순;이광수;이상열
    • 한국해양공학회지
    • /
    • 제27권3호
    • /
    • pp.67-72
    • /
    • 2013
  • In this study, numerical analyses that considered the dynamic interaction effects between the flow and a turbine were carried out to investigate the power output performance of an H-type Darrieus turbine rotor, which is one of the representative lifting-type vertical-axis tidal-current turbines. For this purpose, a commercial CFD code, Star-CCM+, was utilized for an example three-bladed turbine with a rotor diameter of 3.5 m, a solidity of 0.13, and the blade shape of an NACA0020 airfoil, and the optimal tip speed ratio (TSR) and corresponding maximum power coefficient were evaluated through exhaustive simulations with different sets of flow speed and external torque conditions. The optimal TSR and maximum power coefficient were found to be approximately 1.84 and 48%, respectively. The torque and angular velocity pulsations were also investigated, and it was found that the pulsation ratios for the torque and angular velocity were gradually increased and decreased with an increase in TSR, respectively.

Impact of cable sag on the efficiency of an inertial mass damper in controlling stay cable vibrations

  • Wang, Zhi-hao;Gao, Hui;Xu, Yan-wei;Chen, Zheng-qing;Wang, Hao
    • Smart Structures and Systems
    • /
    • 제24권1호
    • /
    • pp.83-94
    • /
    • 2019
  • Passive negative stiffness dampers (NSDs) that possess superior energy dissipation abilities, have been proved to be more efficient than commonly adopted passive viscous dampers in controlling stay cable vibrations. Recently, inertial mass dampers (IMDs) have attracted extensive attentions since their properties are similar to NSDs. It has been theoretically predicted that superior supplemental damping can be generated for a taut cable with an IMD. This paper aims to theoretically investigate the impact of the cable sag on the efficiency of an IMD in controlling stay cable vibrations, and experimentally validate superior vibration mitigation performance of the IMD. Both the numerical and asymptotic solutions were obtained for an inclined sag cable with an IMD installed close to the cable end. Based on the asymptotic solution, the cable attainable maximum modal damping ratio and the corresponding optimal damping coefficient of the IMD were derived for a given inertial mass. An electromagnetic IMD (EIMD) with adjustable inertial mass was developed to investigate the effects of inertial mass and cable sag on the vibration mitigation performance of two model cables with different sags through series of first modal free vibration tests. The results show that the sag generally reduces the attainable first modal damping ratio of the cable with a passive viscous damper, while tends to increase the cable maximum attainable modal damping ratio provided by the IMD. The cable sag also decreases the optimum damping coefficient of the IMD when the inertial mass is less than its optimal value. The theoretically predicted first modal damping ratio of the cable with an IMD, taking into account the sag generally, agrees well with that identified from experimental results, while it will be significantly overestimated with a taut-cable model, especially for the cable with large sag.

Optimal earthquake intensity measures for probabilistic seismic demand models of ARP1400 reactor containment building

  • Nguyen, Duy-Duan;Thusa, Bidhek;Azad, Md Samdani;Tran, Viet-Linh;Lee, Tae-Hyung
    • Nuclear Engineering and Technology
    • /
    • 제53권12호
    • /
    • pp.4179-4188
    • /
    • 2021
  • This study identifies efficient earthquake intensity measures (IMs) for seismic performances and fragility evaluations of the reactor containment building (RCB) in the advanced power reactor 1400 (APR1400) nuclear power plant (NPP). The computational model of RCB is constructed using the beam-truss model (BTM) for nonlinear analyses. A total of 90 ground motion records and 20 different IMs are employed for numerical analyses. A series of nonlinear time-history analyses are performed to monitor maximum floor displacements and accelerations of RCB. Then, probabilistic seismic demand models of RCB are developed for each IM. Statistical parameters including coefficient of determination (R2), dispersion (i.e. standard deviation), practicality, and proficiency are calculated to recognize strongly correlated IMs with the seismic performance of the NPP structure. The numerical results show that the optimal IMs are spectral acceleration, spectral velocity, spectral displacement at the fundamental period, acceleration spectrum intensity, effective peak acceleration, peak ground acceleration, A95, and sustained maximum acceleration. Moreover, weakly related IMs to the seismic performance of RCB are peak ground displacement, root-mean-square of displacement, specific energy density, root-mean-square of velocity, peak ground velocity, Housner intensity, velocity spectrum intensity, and sustained maximum velocity. Finally, a set of fragility curves of RCB are developed for optimal IMs.

풍하중을 받는 태양광 추적 구조물의 응력해석 (Stress Analysis on a Structure of Solar Tracker Subjected to Wind Load)

  • 김용우;김원봉
    • 한국생산제조학회지
    • /
    • 제21권5호
    • /
    • pp.747-754
    • /
    • 2012
  • A solar power generator is usually installed outdoors and it is exposed to extreme environments such as snow weight and wind loading. The solar tracker structure should be designed to have sufficient stiffness and strength against such loads. In this paper, simulations are performed by varying the parameters such as wind directions, wind speeds and the pose of the solar panel to evaluate the effects of extreme wind on solar tracker. As the effects of wind load, maximum displacement and maximum equivalent stress in the solar tracker are calculated. Finite element stress analysis is carried out by using the pressure distribution that is obtained by prior wind load analysis due to the flow around the solar tracker. The stress analysis of solar tracker to check and/or improve structural robustness provides some useful instructions for structural design or revision of solar tracker.

ASSESSMENT OF THE SAFETY OF ULCHIN NUCLEAR POWER PLANT IN THE EVENT OF TSUNAMI USING PARAMETRIC STUDY

  • Kim, Ji-Young;Kang, Keum-Seok
    • Nuclear Engineering and Technology
    • /
    • 제43권2호
    • /
    • pp.175-186
    • /
    • 2011
  • Previous evaluations of the safety of the Ulchin Nuclear Power Plant in the event of a tsunami have the shortcoming of uncertainty of the tsunami sources. To address this uncertainty, maximum and minimum wave heights at the intake of Ulchin NPP have been estimated through a parametric study, and then assessment of the safety margin for the intake has been carried out. From the simulation results for the Ulchin NPP site, it can be seen that the coefficient of eddy viscosity considerably affects wave height at the inside of the breakwater. In addition, assessment of the safety margin shows that almost all of the intake water pumps have a safety margin over 2 m, and Ulchin NPP site seems to be safe in the event of a tsunami according to this parametric study, although parts of the CWPs rarely have a margin for the minimum wave height.

나노유체에서 파울링 현상이 유동 비등 열전달에 미치는 영향에 대한 연구 (A Study on Influence of Flow Boiling Heat Transfer on Fouling Phenomenon in Nanofluids)

  • 김우중;양용우;김영훈;박성식;김남진
    • 설비공학논문집
    • /
    • 제28권3호
    • /
    • pp.95-102
    • /
    • 2016
  • A boiling heat transfer is used in various industry such as power generation systems, heat exchangers, air-conditioning and refrigerations. In the boiling heat transfer system, the critical heat flux (CHF) is the important factor, and it indicated safety of the system. It has kept up studies on the CHF enhancement. Recently, it is reported the CHF enhancement, when working fluid used the nanofluid with high thermal properties. But it could be occurred nanoflouling phenomenon from nanoparticle deposition, when nanofluid applied the heat transfer system. And, it is reported that the safety and thermal efficiency of heat transfer system could decrease. Therefore, it is compared and analyzed to the CHF and the boiling heat transfer coefficient on effect of artificial nanofouling (coating) in oxidized multi-wall carbon nanotube nanofluids. As the result, the CHF of oxidized multi-wall carbon nanofluids and the CHF of artificial nanofouling in the nanofluids increased to maximum 99.2%, 120.88%, respectively. A boiling heat transfer coefficient in nanofluid increased to maximum 24.29% higher than purewater, but artificial nanofouling decreased to maximum -7.96%.

바나듐계 산화-환원 유동 전지의 최대 방전전류와 유량의 상관성에 대한 실험적 연구 (Discharged Maximum Current Density of Vanadium Redox Flow Battery with Increased Electrolyte Flow Rate)

  • 김정명;박희성
    • 대한기계학회논문집B
    • /
    • 제40권12호
    • /
    • pp.777-784
    • /
    • 2016
  • 바나듐 전해질 산화-환원 흐름전지(vanadium redox flow batteries, VRFBs)는 간헐적 에너지 저장 시스템의 에너지 저장장치로 사용된다. VRFBs는 재료 및 동작조건에 따라 성능의 차이를 보이며, 각 성능특성에 따른 VRFBs개발이 요구된다. 본 연구에 사용된 단위셀은 반응면적 $25cm^2$이며, 전해액은 0.6의 충전상태를 나타낸다. 방전전류밀도를 0에서 $520mA/cm^2$ 까지 변화시키면서 동시에 전해질 유량도 5mL/min에서 60mL/min까지 변화시켰다. 동일한 입구 전해액 상태에 따른 방전 성능 평가를 위해 4개의 탱크를 사용한 비순환 시스템을 구축하였다. 본 논문은 유량 및 전류밀도의 변화에 대한 단자전압을 측정하였으며, $25cm^2$ 반응면적을 가지는 바나듐계 산화-환원 유동전지 시스템의 최대전류밀도에 대한 실험식을 도출하였다.

안벽 앞에 설치된 진동수주형 파력발전장치의 반사율과 추출효율과의 상관관계 (Correlation of Reflection Coefficient and Extracted Efficiency of an Oscillating Water Column Device in Front of a Seawall)

  • 조일형;김정록
    • 한국해안·해양공학회논문집
    • /
    • 제32권4호
    • /
    • pp.242-251
    • /
    • 2020
  • 본 연구에서는 직립 안벽 앞에 설치된 2차원 진동수주형 파력발전장치의 추출효율과 반사율을 규칙파와 불규칙파에 대하여 살펴보고 둘 사이의 상관관계를 조사하였다. 해석이론으로 선형포텐셜 이론에 기반을 둔 고유함수전개법을 사용하였다. 공기실이 완전 개방되었을 때 입사파에 의한 산란문제와 공기실이 닫혀 있을 때 공기실내의 변동압력에 의한 파의 방사문제를 풀어 공기실 내부의 유량을 구하고, 이를 공기실내의 공기 흐름에 대한 연속방정식에 대입하여 변동압력을 구한다. 추출파워가 최대가 되는 최적 터빈계수를 적용하여 진동수주형 파력발전장치의 최대 추출효율과 반사율을 규칙파와 불규칙파에 대하여 구하였다. 파랑에너지를 효율적으로 흡수하도록 설계된 진동수주형 파력발전장치는 동시에 반사파를 줄이는데 기여하였다.