황산염이 UASB 반응조에서 혐기성 분해 반응에 미치는 영향 (The Effects of Sulfate on Anaerobic Treatment with UASB)

  • 정승현;양병수
    • 환경위생공학
    • /
    • 제13권2호
    • /
    • pp.47-56
    • /
    • 1998
  • Effects of sulfate on the anaerobic substrate utilization were evaluated using UASB (Upflow Anaerobic Sludge Blanket) reactor. Effect of sulfate on the organic removal rate was dependent on the relative amount of microorganisms in the reactor, the operational condition, and the characteristics of sludge. When the sulfate shock was applied to 0.0 - 3.0g SO$_{4}$$^{2-}$/d, more than 95% of COD removal efficiency was achieved. Therefore, if F/M ratio was kept to low sufficiently with recirculation, it is shown that operation of the reactor was not affected significantly, though sulfate shock load was doubled compared to the normal operation. Provided that it is shocked by high strength of sulfate or temporary shock load is applied frequently the efficiency of reactor may be disadvantageous as well as the wash-out of sludge will be increased by decreasing the size to the accumulated frequency of granular sludge and the size with maximum frequency.

  • PDF

서울 도시철도 9호선의 운영분야 혁신방안 (Renovation plans of operation field of Seoul Metro Line 9)

  • 한우진;박정수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1441-1446
    • /
    • 2008
  • Seoul Metro Line 9 (SML9) is the first subway line that private capital invests in Korea. SML9 will cross Seoul, linking the Gimpo Airport to the Gangnam district (25.5km) opening in the first half of 2009. SML9 has a new model in Korea constructed by metropolitan government and private company and operated by specialized public transportation service provider. SML9 is confronted with tough environment of stagnated public transportation and strong competitor, Olympic city expressway. And SML9 is under pressure for showing high efficiency as non-governmental organization from both customers and government. Consequently SML9 must lead the maximum efficiency by using its material and human resource. It is necessary that SML9 raise a competitive power and display its ability in active collaboration with relative organization and company. Hereupon, I propose renovation plans from viewpoint of operation field of SML9, (1) efficient train scheduling regime focusing on the combination of express and local train (2) close connection of other mean of transportation and (3) effective connection convention with Airport Railroad (AREX) as the line connected directly.

  • PDF

최적화 기법을 이용한 에너지 효율 프로그램의 지원금 수준 산정 (Estimation of Rebate Level for Energy Efficiency Programs Using Optimization Technique)

  • 박종진;소철호;김진오
    • 전기학회논문지
    • /
    • 제57권3호
    • /
    • pp.369-374
    • /
    • 2008
  • This paper presents the evaluation procedures and the estimation method for the estimation of optimal rebate level for EE(Energy Efficiency) programs. The penetration amount of each appliance is estimated by applying price function to preferred diffusion model resulted from model compatibility test. To estimate the optimal rebate level, two objective functions which express the maximum energy saving and operation benefit are introduced and by multi-objective function which can simultaneously consider two objective functions the optimal rebate level of each appliance is estimated. And then, using the decided rebate level and each penetration amount, the priority order for reasonable investment of each high-efficiency appliance is estimated compared to the results of conventional method. Finally, using a benefit/cost analysis based on California standard practice manual, the economic analysis is implemented for the four perspectives such as participant, ratepayer impact measure, program administrator cost and total resource cost.

동기 리럭턴스 전동기의 고성능 운전을 위한 효율 최적화 제어 (Efficiency Optimization Control for High Performance Operation of Synchronous Reluctance Motor)

  • 정동화;이정철;이홍균
    • 한국안전학회지
    • /
    • 제16권2호
    • /
    • pp.51-56
    • /
    • 2001
  • This paper is proposed an efficiency optimization control algorithm for a synchronous reluctance motor (SynRM) which minimizes the copper and iron losses. fen exists a variety of combinations of d and q-axis current which provide a specific motor torque. The objective of the efficiency optimization controller is to seek a combination of d and q-axis current components, which provides minimum losses at a certain operating point in steady state. It is shown that the current components which directly govern the torque production have been very well regulated by the efficiency optimization control scheme. The proposed algorithm allows the electromagnetic losses in variable speed and torque drives to be reduced while keeping good torque control dynamics. Simulation results are presented to show the validity of the proposed algorithm.

  • PDF

복합형 태양열 가열기의 일일 운전 특성 및 축열 성능에 관한 연구 (A Study on Thermal Storage Performance and Characteristics of Daily Operation of a Hybrid Solar Air-Water Heater)

  • 최휘웅;파쿠르 로커만;윤정인;손창효;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제35권3호
    • /
    • pp.73-79
    • /
    • 2015
  • In this study, a thermal storage performance and characteristics of daily operation were investigated when the air and the liquid were heated simultaneously by a hybrid solar air-water heater that can make hot water as well as heated air. The hybrid solar air-water heater is kind of a flat plate solar collector that can make hot water and heated air by installing air channel beneath absorber plate of traditional flat plate solar collector for hot water. As a result of daily operation, maximum water temperature reached in a thermal storage was shown $44^{\circ}C$ on 73kg/h of air mass flow rate and about $40^{\circ}C$ on 176kg/h of air mass flow rate. Thus, the necessity of heating water in thermal storage by operating only liquid side was confirmed when the temperature of liquid in thermal storage is lower than we need. In case of efficiency investigated on daily operation, the thermal efficiency of the liquid side was decreased with increment of the inlet liquid temperature and decrement of the solar radiation, but efficiency of the air side was increased with increment of inlet liquid temperature difference as the traditional solar air heater. Total thermal efficiency of the collector was shown from 65.85% to 78.23% and it was decreased with increment of the inlet liquid temperature and decrement of solar radiation same as the traditional system.

IPMSM의 비선형 적응 백스텝핑 속도 제어 (Nonlinear and Adaptive Back-Stepping Speed Control of IPMSM)

  • 전용호;정승환;최익;조황
    • 전력전자학회논문지
    • /
    • 제18권1호
    • /
    • pp.18-25
    • /
    • 2013
  • In this paper, a nonlinear controller based on adaptive back-stepping method is proposed for high performance operation of Interior Permanent Magnet Synchronous Motor (IPMSM). First, in order to improve the performance of speed tracking, a nonlinear back-stepping controller is designed. In addition, since it is difficult to achieve the high quality control performance without considering parameter variation, a parameter estimator is included to adapt to the variation of load torque in real time. Finally, for the efficiency of power consumption of the motor, controller is designed to operate motor with the minimum current for the required maximum torque. The proposed controller is tested through experiment with a 1-hp Interior Permanent Magnet Synchronous Motor (IPMSM) for the angular velocity reference tracking performance and load torque volatility estimation, and to test the Maximum Torque per Ampere (MTPA) operation. The result verifies the efficacy of the proposed controller.

패킷부분재전송기법의 수율 최저 한계 (Lower Bound of Partial Packet Recovery)

  • 정충교
    • 산업기술연구
    • /
    • 제28권A호
    • /
    • pp.113-117
    • /
    • 2008
  • Wireless carrier sense multiple access (CSMA) systems are widely used but show extremely different transmission efficiency according to the operation environment. Simulation or prototype deployment is needed to see the transmission efficiency of a wireless CSMA system with the partial packet retransmission scheme. The lower bound for the transmission efficiency of such a system is found mathematically in this work. This shows how much the partial packet retransmission scheme improves the transmission efficiency quantitatively. It also shows that the maximum throughput is obtained at higher offered load compared to the conventional CSMA system without the partial packet transmission. The result of this work can be applied to IEEE 802.11 networks or wireless mesh networks.

  • PDF

IPMSM 전동기의 비선형 적응 백스텝핑 속도 제어 (Nonlinear and Adaptive Back-Stepping Speed Control of IPMSM)

  • 전용호;조황
    • 한국전자통신학회논문지
    • /
    • 제6권6호
    • /
    • pp.855-864
    • /
    • 2011
  • 본 논문은 IPMSM(Interior Permanent Magnet Synchronous Motor)의 고성능 운전을 위해 비선형 제어를 기반으로 하는 적응 백스텝핑 제어기를 제안한다. 먼저 각속도의 추종성능을 향상시키기 위해서 비선형 백스텝핑 제어기를 설계한다. 파라메타 변동의 영향을 고려하지 않고 설계된 제어기는 고성능 운전이 어렵다. 부하토크의 변동에 대해 실시간 적응할 수 있는 파라메타 추정기를 설계에 포함하여 고성능 운전이 가능하게 한다. 또한 전동기의 효율적인 전력소비를 위하여 최대토크를 얻기 위한 최소전류의 운전을 할 수 있도록 제어기를 설계하였다. 제안된 제어기로 2마력급의 IPMSM에 적용하여 각속도 레퍼런스에 대한 추종성능과 부하토크 변동에 대한 추정, 그리고 MTPA(Maximum Torque per Ampere) 운전을 시험하여 일정토크 운전영역에서 안정화된 강건한 제어기임을 시뮬레이션을 통해 확인할 수 있었다.

Unbounded Binary Search Method for Fast-tracking Maximum Power Point of Photovoltaic Modules

  • Hong, Yohan;Kim, Yong Sin;Baek, Kwang-Hyun
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제5권6호
    • /
    • pp.454-461
    • /
    • 2016
  • A maximum power point tracking (MPPT) system with fast-tracked time and high power efficiency is presented in this paper. The proposed MPPT system uses an unbounded binary search (UBS) algorithm that continuously tracks the maximum power point (MPP) with a binary system to follow the MPP under rapid-weather-change conditions. The proposed algorithm can decide the correct direction of the MPPT system while comparing the previous power point with the present power point. And then, by fixing the MPP until finding the next MPP, there is no oscillation of voltage MPP, which maximizes the overall power efficiency of the photovoltaic module. With these advantages, this proposed UBS is able to detect the MPP more effectively. This MPPT system is based on a boost converter with a micro-control unit to control analog-to-digital converters and pulse width modulation. Analysis of this work and experimental results show that the proposed UBS MPPT provides fast, accurate tracking with no oscillation in situations where weather rapidly changes and shadow is caused by all sorts of things. The tracking time is reduced by 87.3% and 66.1% under dynamic-state and steady-state operation, respectively, as compared with the conventional 7-bit perturb and observe technique.

Development and Testing of a Prototype Long Pulse Ion Source for the KSTAR Neutral Beam System

  • Chang Doo-Hee;Oh Byung-Hoon;Seo Chang-Seog
    • Nuclear Engineering and Technology
    • /
    • 제36권4호
    • /
    • pp.357-363
    • /
    • 2004
  • A prototype long pulse ion source was developed, and the beam extraction experiments of the ion source were carried out at the Neutral Beam Test Stand (NBTS) of the Korea Superconducting Tokamak Advanced Research (KSTAR). The ion source consists of a magnetic bucket plasma generator, with multi-pole cusp fields, and a set of tetrode accelerators with circular apertures. Design requirements for the ion source were a 120kV/65A deuterium beam and a 300 s pulse length. Arc discharges of the plasma generator were controlled by using the emission-limited mode, in turn controlled by the applied heating voltage of the cathode filaments. Stable and efficient arc plasmas with a maximum arc power of 100 kW were produced using the constant power mode operation of an arc power supply. A maximum ion density of $8.3{\times}10^{11}\;cm^{-3}$ was obtained by using electrostatic probes, and an optimum arc efficiency of 0.46 A/kW was estimated. The accelerating and decelerating voltages were applied repeatedly, using the re-triggering mode operation of the high voltage switches during a beam pulse, when beam disruptions occurred. The decelerating voltage was always applied prior to the accelerating voltage, to suppress effectively the back-streaming electrons produced at the time of an initial beam formation, by the pre-programmed fast-switch control system. A maximum beam power of 0.9 MW (i.e. $70\;kV{\times}12.5\;A$) with hydrogen was measured for a pulse duration of 0.8 s. Optimum beam perveance, deduced from the ratio of the gradient grid current to the total beam current, was $0.7\;{\mu}perv$. Stable beams for a long pulse duration of $5{\sim}10\;s$ were tested at low accelerating voltages.