• Title/Summary/Keyword: Maximum amplitude

Search Result 762, Processing Time 0.031 seconds

Experimental and Analytical Study of a Cooling Mechanism Using Acoustic Streaming by Ultrasonic Vibrations (초음파진동에 의한 음향유동을 활용한 냉각 메카니즘의 실험 및 이론적 연구)

  • Loh, Byoung-Gook;Lee, Dong-Ryul
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.9
    • /
    • pp.694-702
    • /
    • 2003
  • A cooling mechanism using acoustic streaming by ultrasonic vibrations and associated convective heat transfer enhancement is investigated experimentally and analytically. Acoustic streaming pattern and associated heat transfer characteristics are presented. Analytical transient temperature profile of the heated plate following Nyborgs theory is accomplished along with experimental measurement. A temperature drop of 30 C is obtained in 4 minutes with vibration amplitude of 10${\mu}{\textrm}{m}$. As the vibration amplitude is further increased to 25${\mu}{\textrm}{m}$ a temperature drop of 40 C is achieved that is the maximum temperature drop obtained with the current experimental apparatus. Analytical heat transfer solutions verified a temperature drop of 4$0^{\circ}C$ with a vibration amplitude of 25${\mu}{\textrm}{m}$ at 28.4 kHz which is experimentally obtained.

A New Design of Signal Constellation of the Spiral Quadrature Amplitude Modulation (나선 직교진폭변조 신호성상도의 새로운 설계)

  • Li, Shuang;Kang, Seog Geun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.3
    • /
    • pp.398-404
    • /
    • 2020
  • In this paper, we propose a new design method of signal constellation of the spiral quadrature amplitude modulation (QAM) exploiting a modified gradient descent search algorithm and its binary mapping rule. Unlike the conventional method, the new method, which uses and the constellation optimization algorithm and the maximum number of iterations as a parameter for the iterative design, is more robust to phase noise. And the proposed binary mapping rule significantly reduces the average Hamming distance of the spiral constellation. As a result, the proposed spiral QAM constellation has much improved error performance compared to the conventional ones even in a very severe phase noise environment. It is, therefore, considered that the proposed QAM may be a useful modulation format for coherent optical communication systems and orthogonal frequency division multiplexing (OFDM) systems.

The effect of transverse shear deformation on the post-buckling behavior of functionally graded beams

  • Meksi, Ali;Youzera, Hadj;Sadoun, Mohamed;Abbache, Ali;Meftah, Sid Ahmed;Tounsi, Abdelouahed;Hussain, Muzamal
    • Steel and Composite Structures
    • /
    • v.44 no.1
    • /
    • pp.81-89
    • /
    • 2022
  • The purposes of the present work it to study the effect of shear deformation on the static post-buckling response of simply supported functionally graded (FGM) axisymmetric beams based on classical, first-order, and higher-order shear deformation theories. The behavior of postbuckling is introduced based on geometric nonlinearity. The material properties of functionally graded materials (FGM) are assumed to be graded in the thickness direction according to a simple power law distribution in terms of the volume fractions of the constituents. The equations of motion and the boundary conditions derived using Hamilton's principle. This article compares and addresses the efficiency, the applicability, and the limits of classical models, higher order models (CLT, FSDT, and HSDT) for the static post-buckling response of an asymmetrically simply supported FGM beam. The amplitude of the static post-buckling obtained a solving the nonlinear governing equations. The results showing the variation of the maximum post-buckling amplitude with the applied axial load presented, for different theory and different parameters of material and geometry. In conclusion: The shear effect found to have a significant contribution to the post-buckling behaviors of axisymmetric beams. As well as the classical beam theory CBT, underestimate the shear effect compared to higher order shear deformation theories HSDT.

Response Characteristics of the PZT Transducers during Glass Capillary Breakage (유리모세관 파괴시 방출된 탄성파에 대한 PZT 변환기의 응답특성)

  • Lee, Jong-Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.18 no.1
    • /
    • pp.33-41
    • /
    • 1998
  • The response characteristics of the PZT transducers during glass capillary breakage were studied at the epicenter of the glass plate. The PZT transducers had been made by using EC-65 PZT ceramics(supplied by Edo co.) with a constant area and a various thickness. The theoretical displacement and velocity at the epicenter of glass plate with an air boundary condition were calculated by assuming the point load of 1N force strength and a rise time of 280 ns with a ramped functional dependence, and the 1st pulses of the PZT transducer may be considered as the vertical velocity incident on the electrode of the PZT ceramic. The responses of the PZT transducer may be depended on the thickness mode of the PZT ceramic below 0.33 in the ratio of the thickness to the diameter of PZT ceramic, but the reponse of the PZT transducer may be depended on the other modes of PZT transducer in the addition of the thickness mode of the PZT ceramic above 0.33. The full time of half maximum at the 1st pulse was nearly 280 ns without a variation of applied breakage load and the resonant frequency of the PZT transducer, and then may be considered as the rise time of a AE source. The maximum amplitude of the 1st pulse depended on the incident vertical velocity and capacitance of the PZT transducer. Therefore, the full time of half maximum and maximum amplitude of the 1st pulse may be considered as the rise time and strength of acoustic emission source respectively.

  • PDF

The Value of Isotope Nephrography in Carcinoma of Cervix - Follow up Studies of Pre and Post Irradiation (자궁경부암(子宮頸部癌) 방사선치료(放射線治療) 전후(前後) Renogram의 의의(意義))

  • Yoo, H.S.;Suh, J.H.;Park, C.Y.;Choi, B.S.;Jung, S.O.;Kwak, H.M.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.9 no.1
    • /
    • pp.51-58
    • /
    • 1975
  • It is a great value to find an early detection of involvement of ureteric obstruction in the carcinoma of cervix. Little or no knowledge of the condition of the kidneys or the lower urinary tract are able to elucidate by the biochemical studies such as blood nitrogen or urine creatinine in carcinoma of cervix. Findings of urography delineates the condition of urinary tract stasis in the renal pelvis and ureters, however, slight stasis maybe difficult to demonstrate. On the other hand isotope nephrography is accepted as a sensitive method to observe renal function especially in regarding to the excretory function of kidney. It was attempted to analysis the findings of urography conjunction with isotope nephrography in 50 cases of unselected patients with invasive carcinoma of cervix through pre and post irradiation follow up studies. Urography was done as a routine procedure and.analysed emphasising changes of collecting systems and ureter condition. Isotope nephrography was carried out by means of $15{\mu}ci\;I^{131}$-Hippuran injected intravenously and the curves were analysed as follows. Parameter were; time of maximum amplitude ($T_{max}$), half time of maximum amplitude ($T\frac{1}{2}$), Kac and Kex value calculated from these two parameters in Tobe's method. The excretion index by Aurell defines the ratio between the maximum activity and the activity measured on the slope of the third phase ten minites after it has reached its maximum. Results: 1. 28.8% had an abnormal IVP suggestive of ureteric involvement before irradiation therapy and the patient of stage III and IV were the great part. 2. 21.7% had abnormal findings of per-irradiation renogram whom showed normal IVP. The other group showed normal IVP which group also showed normal renogram prior irradiation. 3. The more severe the ureteric involvement, the change of excretion index was greater. 4. Even in stage I and II patient, abnormal renogram was revealed in 12 cases (39.4%) among 31 cases. 5. All cases of TAH showed abnormal findings of IVP and renogram. 6. No. definite change of renogram was obtained just after the irradiation therapy (point $A:8000{\sim}9000rads,\;B:5000{\sim}6000rads,\;Co:11000{\sim}13000rads$). Each 3 month follow up study was performed and comparing with preirradiation study which showed significant changes of excretion index of renogram were 42.8% in $6{\sim}9$ month follow-up and 75% in $9{\sim}12$ month, respectively. 7. It seems to be important to observe the parameter Kex and excretion index of renogram to determine early abnormality of kidney excretory function by means of post-irradiation follow up study.

  • PDF

Changes of Hysteresis Loop Characteristics of the Tendon Under Tensile Stress (Tendon의 인장응력에 따른 자기이력특성 변화의 측정)

  • Kang, Sunju;Son, Derac;Joh, Changbin;Lee, Jungwoo
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.4
    • /
    • pp.123-128
    • /
    • 2015
  • The iron is an element having a high yield strength, mechanical hardness, good electrical conductivity, and also it has been used in various fields because of ease machining. In bridges have been used tendon made of a steel wire for large loads and light weight. Tension measurement of tendon employed in PreStressed Concrete (PSC) bridge is very important for the bridge safety check. NDT (Non-Destructive Testing) is essential for the safety check, however, magnetic NDT is difficult to apply due to the non-linear magnetization curve and hysteresis loop in the magnetic properties. In this work, for basic study of magnetic NDT application, we have constructed a B-H loop measuring system for 7-strand tendon of which diameter is 15.5 mm, and which can apply tensile stress up to 2.0 GPa. We have measured hysteresis loops of two kinds of tendons under different tensile stress. Amplitude permeability and maximum magnetic induction near knee show the most sensitive and high linearity depends on tensile stress. Relative amplitude permeability was decreased from 500 to 200 and maximum magnetic flux density changed 0.6 T.

A study on monitoring for process time and process properties by measuring vibration signals transmitted to the mold during injection molding (사출성형공정에서 금형에 전달되는 진동 신호 측정을 이용한 성형 단계별 공정시간과 공정특성의 모니터링에 대한 연구)

  • Lee, Jun-han;Kim, Jong-Sun
    • Design & Manufacturing
    • /
    • v.14 no.3
    • /
    • pp.8-16
    • /
    • 2020
  • In this study, the vibration signal of the mold was measured and analyzed to monitoring the process time and characteristics during injection molding. A 5 inch light guide plate mold was used to injection molding and the vibration signal was measured by MPU6050 acceleration sensor module attached the surface of fixed mold base. Conditions except for injection speed and packing pressure were set to the same value and the change of the vibration signal of the mold according to injection speed and packing pressure was analyzed. As a result, the vibration signal had a large change at three points: "Injection start", "V/P switchover", and "Packing end". The time difference between "injection start" and "V/P switchover" means the injection time in the injection molding process, and the time difference between "V/P switchover" and "Packing end" means the packing time. When the injection time and packing time obtained from the vibration signal of the mold are compared with the time recorded in the injection molding machine, the error of the injection time was 2.19±0.69% and the error of the packing time was 1.39±0.83%, which was the same level as the actual value. Additionally, the amplitude at the time of "injection start" increased as the injection speed increased. In "V/P switchover", the amplitude tended to be proportional to the pressure difference between the maximum injection pressure and the packing pressure and the amplitude at the "packing end" tended to the pressure difference between the packing pressure and the back pressure. Therefore, based on the result of this study, the injection time and packing time of each cycle can be monitored by measuring the vibration signal of the mold. Also, it was confirmed that the level and trend of process variables such as the injection speed, maximum injection pressure, and packing pressure can be evaluated as the change of the mold vibration during injection molding.

Extra-phase Image Generation for Its Potential Use in Dose Evaluation for a Broad Range of Respiratory Motion

  • Lee, Hyun Su;Choi, Chansoo;Kim, Chan Hyeong;Han, Min Cheol;Yeom, Yeon Soo;Nguyen, Thang Tat;Kim, Seonghoon;Choi, Sang Hyoun;Lee, Soon Sung;Kim, Jina;Hwang, JinHo;Kang, Youngnam
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.3
    • /
    • pp.103-109
    • /
    • 2019
  • Background: Four-dimensional computed tomographic (4DCT) images are increasingly used in clinic with the growing need to account for the respiratory motion of the patient during radiation treatment. One of the reason s that makes the dose evaluation using 4DCT inaccurate is a change of the patient respiration during the treatment session, i.e., intrafractional uncertainty. Especially, when the amplitude of the patient respiration is greater than the respiration range during the 4DCT acquisition, such an organ motion from the larger respiration is difficult to be represented with the 4DCT. In this paper, the method to generate images expecting the organ motion from a respiration with extended amplitude was proposed and examined. Materials and Methods: We propose a method to generate extra-phase images from a given set of the 4DCT images using deformable image registration (DIR) and linear extrapolation. Deformation vector fields (DVF) are calculated from the given set of images, then extrapolated according to respiratory surrogate. The extra-phase images are generated by applying the extrapolated DVFs to the existing 4DCT images. The proposed method was tested with the 4DCT of a physical 4D phantom. Results and Discussion: The tumor position in the generated extra-phase image was in a good agreement with that in the gold-standard image which is separately acquired, using the same 4DCT machine, with a larger range of respiration. It was also found that we can generate the best quality extra-phase image by using the maximum inhalation phase (T0) and maximum exhalation phase (T50) images for extrapolation. Conclusion: In the present study, a method to construct extra-phase images that represent expanded respiratory motion of the patient has been proposed and tested. The movement of organs from a larger respiration amplitude can be predicted by the proposed method. We believe the method may be utilized for realistic simulation of radiation therapy.

Development of Ultrasound Diagnostic System for Functional Gastrointestinal Disorders using Finite Difference Method (유한차분법을 이용한 기능성 위장 장애 진단용 초음파 시스템의 개발)

  • Park, Won-Pil;Woo, Dae-Gon;Ko, Chang-Yong;Lee, Qyoun-Jung;Lee, Yong-Heum;Choi, Seo-Hyoung;Shin, Tae-Min;Kim, Han-Sung;Lim, Do-Hyung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.9
    • /
    • pp.130-139
    • /
    • 2007
  • The disaster from functional gastrointestinal disorders (FGID) has detrimental impact on the quality of life of the affected population. There are, however, rare diagnostic methods for FGID. Our research group identified recently that the gastrointestinal tract well of the patients with FGID became more rigid than that of healthy people when palpating the abdominal regions overlaying the gastrointestinal tract. The objective of the current study is, therefore, to identify feasibility of a diagnostic system for FGID based on ultrasound technique, which can quantify the characteristics above. Two-dimensional finite difference (FD) models (one normal and two rigid models) were developed to analyze the reflective characteristic (displacement) on each soft-tissue layer responded after application of ultrasound signals. Based on the results from FD analysis, the ultrasound system for diagnosis of the FGID was developed and clinically tested via application of it to 40 human subjects with/without FGID who were assigned to Normal and Patient Groups. The results from FD analysis showed that the maximum displacement amplitude in the rigid models (0.12 and 0.16) at the interface between the fat and muscle layers was explicitly less than that in the normal model (0.29). The results from actual specimens showed that the maximum amplitude of the ultrasound reflective signal in the rigid models $(0.2{\pm}0.1Vp-p)$ at the interface between the fat and muscle layers was explicitly higher than that in the normal model $(0.1{\pm}0.0Vp-p)$. Clinical tests using our customized ultrasound system showed that the maximum amplitudes of the ultrasound reflective signals near to the gastrointestinal tract well for the patient group $(2.6{\pm}0.3Vp-p)$ were generally higher than those in normal group $(0.1{\pm}0.2Vp-p)$. These findings suggest that our customized ultrasound system using the ultrasound reflective signal may be helpful to the diagnosis of the FGID.

HF-Band Magnetic-Field Communication System Using Bias Switching Circuit of Class E Amplifier (E급 증폭기의 바이어스 스위칭 회로를 이용한 HF-대역 자기장 통신 시스템)

  • Son, Yong-Ho;Lee, June;Cho, Sang-Ho;Jang, Byung-Jun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.9
    • /
    • pp.1087-1093
    • /
    • 2012
  • In this paper, we implemented a HF-band magnetic-field communication system consisting of an amplitude shift keying(ASK) transmitter, a pair of loop antennas, and an ASK receiver. Especially, we suggested a new ASK transmitter architecture, where a drain bias of class E amplifier is switched alternatively between two voltage levels with respect to input data. A maximum 5 W class E amplifier was designed using a low cost IRF510 power MOSFET at the frequency of 6.78 MHz. A measured sensitivity of the designed ASK receiver is -78 dBm, which consists of a log amplifier, a filter, and a comparator. Maximum communication range of magnetic-wave communication system with loop antennas was calculated using magnetic field equations in both near-field and far-field ranges. Also, in order to verify the calculated values, an indoor propagation loss was measured using a pair of loop antennas whose dimensions are $30{\times}30cm$. Maximum operating range is estimated about 35 m in case of transmitter's output power of 1 W and receiver sensitivity of -70 dBm, respectively. Finally, the communication field test using the designed ASK transmitter and receiver was successfully done at the distance of 5 m.