• Title/Summary/Keyword: Maximum amplitude

Search Result 761, Processing Time 0.022 seconds

Stuctural Characteristics on Drilling Center Column made of Epoxy-granite Material (드릴링 센타용 에폭시-그래나이트재 컬럼의 구조물 특성 연구)

  • 원시태
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1995.03a
    • /
    • pp.158-165
    • /
    • 1995
  • A new fungible materal named Epoxy-Granite composite is applied to the column structure of drilling center in order to investigate the advanced dynamic chatateristics comparing with a conventional cast iron material. The dimensions of new colum structure are adjusted to keep the same stiffness (El value) and the manufacturing conditions are formulated based on the preceeding research experience about the development of Epoxy-Granite structural material. The two kinds of experiments are set up. one of which is for the measurement of natural mode and frequency using experimental modal analysis and the other one is for the measurement of vibration amplitude during idling operation of a machine fool. The comparison of maximum, accelerance values at each natural frequency of bending mode shows a Epoxy-Granite column have larger modal damping ratios(over 2times) than a cast iron column. The vibration amplitude of Epoxy-Granite column measued on the bed motor base and top of column are also much smaller (up to 12%) than the case of cast iron column. It is therefore confirmed that a Epoxy-Granite materal exhibits a good anti-vibrational property even if it is used under the actual operational environments of machine eool as a practical structural element.

  • PDF

Study on NMR Measurment of Flowing Water by a Separated Detector (분리형 감지기를 이용한 흐르는 물의 핵자기공명 측정연구)

  • ;;;;V. Ya. Shifrin
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.3
    • /
    • pp.165-170
    • /
    • 1995
  • NMR measurement has been studied for protons in pre-polarized flowing water by a separated detector working at high field far away from the measured field region where the transition of protons is occurred by the pertur-bation of RF energy. The conditions for NMR signal were optimized on the amplitude and frequency of modulation field, the RF field of detector, water speed, and RF field at the measured field region. The NMR signal with the full width of 320 nT at the half maximum in Lorentzian curve and with signal to noise ratio of 10.5 was measured in the range from a few ${\mu}T$ to mT, and its shape and amplitude were independent of the measured field intensity and its uniformity.

  • PDF

A Study of the Digital Modulation using DSP (DSP를 이용한 디지털 변조에 관한 연구)

  • 최상권;최진웅;김정국
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2001.06a
    • /
    • pp.89-92
    • /
    • 2001
  • In this paper, as a study of programmable software radio digital communication, we implemented ASK(Amplitude Shift Keying), FSK(Frequency Shift Keying), and PSK(Phase Shift Keying) modulation using programmable software(algorithm) of DSP(Digital Signal Processor). Moreover, it is possible to select one of those three modulation methods by realizing on single DSP. We adopted Motorola DSP56002 and Crystal CS4215(A/D and D/A converter) for our purpose. The DSP56002 is 24-bit and operates 20 MIPS at 40 MHz, and the CS4215 is 16-bit and supports the maximum 50 kHz sampling frequency.

  • PDF

DEVELOPMENT OF A TOY INTERFEROMETER FOR EDUCATION AND OBSERVATION OF SUN AT 21 cm

  • Park, Yong-Sun;Kim, Chang-Hee;Choi, Sang-In;Lee, Joo-Young;Jang, Woo-Min;Kim, Woo-Yeon;Jeong, Dae-Heon
    • Journal of The Korean Astronomical Society
    • /
    • v.41 no.3
    • /
    • pp.77-81
    • /
    • 2008
  • As a continuation of a previous work by Park et al. (2006), we have developed a two-element radio interferometer that can measure both the phase and amplitude of a visibility function. Two small radio telescopes with diameters of 2.3 m are used as before, but this time an external reference oscillator is shared by the two telescopes so that the local oscillator frequencies are identical. We do not use a hardware correlator; instead we record signals from the two telescopes onto a PC and then perform software correlation. Complex visibilities are obtained toward the sun at ${\lambda}\;=\;21\;cm$, for 24 baselines with the use of the earth rotation and positional changes of one element, where the maximum baseline length projected onto UV plane is ${\sim}\;90{\lambda}$. As expected, the visibility amplitude decreases with the baseline length, while the phase is almost constant. The image obtained by the Fourier transformation of the visibility function nicely delineates the sun, which is barely resolved due to the limited baseline length. The experiment demonstrates that this system can be used as a "toy" interferometer at least for the education of (under)graduate students.

Performance Analysis of 16 star-QAM with Diversity Reception in Microcell Systems (마이크로셀 시스템에서 다양성 기법을 도입한 16 star-QAM의 성능 해석)

  • 지수복;고봉진
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.1A
    • /
    • pp.1-9
    • /
    • 2000
  • This paper presents the error performance of 16 star-QAM with diversity reception in microcell systems in the presence of additive white Gaussian noise(AWGN) and cochannel interference. The differential detection of 16 star-QAM is split into phase detection and amplitude detection. This technique can reduce the degradation of error performance which is due to fading and the complexity of receiver. Diversity reception is proposed to improve the degradation of error performance due to fading. Equal gain and maximal ratio combinings were adopted for the phase detection and the amplitude detection, respectively. The performance of 16 star-QAM was evaluated for various of Rician factor K, maximum Doppler frequency f_DT, signal to cochannel interference ratio and diversity branch L.

  • PDF

A Prediction of Coronary Perfusion Pressure Using the Extracted Parameter From Ventricular Fibrillation ECG Wave (심실세동 심전도 파형 추출 파라미터를 이용한 관상동맥 관류압 예측)

  • Jang Seung-Jin;Hwang Sung-Oh;Yoon Young-Ro;Lee Hyun-Sook
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.4
    • /
    • pp.274-283
    • /
    • 2005
  • Coronary Perfusion Pressure(CPP) is known for the most important parameter related to the Return of Spontaneous Circulation (ROSC), however, clinically measuring CPP is difficult either invasive or non-invaisive method. En this paper, we analyze the correlation between the extracted parameter from VF ECG wave and the CPP with the statistical method, and predict CPP value using the extracted parameters within significance level. the extracted parameters are median frequency(MF), peak frequency(PF), average segment amplitude(ASA), MSA(maximum segment amplitude), Two parameters, MF, and ASA are selected in order to predict CPP value with general regression neural network, and then we evaluated the agreement statistics between the simulated CPP and the measured CPP. In conclusion, the mean and variance of the difference between the simulated CPP and the measured CPP are 8.9716±1.3526 mmHg, and standard deviation 6.4815 mmHg with one hundred-times training and test results. the simulated CPP and the measured CPP are agreed with the overall accuracy $90.68\%$ and kappa coefficient $81.14\%$ as a discriminant parameter of ROSC.

Mechanical Properties of Mica/Epoxy Composite Materials used in Genrator Stator Windings (발전기 고정자 권선에 사용되는 마이카/에폭시 복합재료의 기계적 특성에 관한 연구)

  • 김희동;김희곤;김태완;강도열
    • Electrical & Electronic Materials
    • /
    • v.10 no.4
    • /
    • pp.327-333
    • /
    • 1997
  • Experiments on mechanical fatigue were conducted using the specimens which were cut from hydrogen cooled generator(rated 22kV and 50OMW) stator windings. We have investigated the aged mechanism of mica/epoxy insulation systems under air or hydrogen by both the tensile and compressive loadings. The fracture of generator stator windings is generally affected by mechanical stress. Thus, the tensile strength test were conducted. In this case, the maximum strength and strain are quite different between sound and aged specimens. It is observed that low bonded interface parts of tapes generally have lower strength than those of normal tapes which causes stress. In order to estimate the effects of cyclic load by the electromagnetic forces while the generator starts/stops, the mechanical fatigue test was also conducted. It is confirmed that the equation of expected life depends on stress amplitude and number of cycles. Though the stress amplitude and number of cycles are very tiny, the tensile fatigue of aged specimens under hydrogen atmosphere is bigger than those under air. In the case of hydrogen atmosphere, the tensile stress gives bigger effect than the compressive one.

  • PDF

Low cycle fatigue and ratcheting failure behavior of AH32 steel under uniaxial cyclic loading

  • Dong, Qin;Yang, Ping;Xu, Geng
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.11 no.2
    • /
    • pp.671-678
    • /
    • 2019
  • In this paper, the low cycle fatigue failure and ratcheting behavior, as well as their interaction of AH32 steel were experimentally investigated under uniaxial cyclic loading. The effects of mean stress, stress amplitude and stress ratio on the low cycle fatigue life and ratcheting strain were discussed. It was found that the ratcheting strain increased while the fatigue life decreased with the increase of mean stress and stress amplitude, and the increasing stress ratio would result in smaller ratcheting and larger fatigue life. Two kinds of failure modes, i.e. low cycle fatigue failure due to crack propagates and ratcheting failure due to large plastic strain will take place respectively. Based on the experimental results, considered the effect of ratcheting on fatigue life, a model with the maximum stress and ratcheting strain rate was proposed. Comparison with the experimental result showed that the new model provided a good prediction for AH32 steel.

A Study of Preventing Pressure Oscillation for Supersonic Inlet of IRR at the Boosting Mode (부스팅 모드에서 IRR(Integral Rocket Ramjet) 초음속 흡입구의 압력진동 감쇄 방안 연구)

  • Park, Geun-Hong;Yoon, Hyun-Gull;Lim, Jin-Shik
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.563-564
    • /
    • 2010
  • A Numerical analysis of preventing pressure oscillation for the supersonic inlet of IRR at the boosting mode was conducted in this study. To reduce the fluctuation of pressure, the supersonic inlet was equipped with annular slit. By decreasing the entrained air mass, the amplitude of fluctuation and maximum pressure at the inlet were decreased while the frequency was increased. In case, the optimal trade-off value is obtained between frequency and amplitude, it is expected that the pressure oscillation declining method using the slit will be helpful in various boosting and transition mode problem for IRR.

  • PDF

A Study on the Development of R-R Interval Analyzer using Microcomputer (1) (Microcomputer를 이용한 R-R Interval Analyzer 개발에 관한 연구 (1))

  • Lee, Joon-Ha;Choi, Soo-Bong
    • Journal of Yeungnam Medical Science
    • /
    • v.2 no.1
    • /
    • pp.77-80
    • /
    • 1985
  • The R-R interval analyzer was developed to measure the autonomic nervous system function using microcomputer. The system based on 8 bit microcomputer including bandpass filter, R-wave detector and clock generator in order to obtain the mean value, standard deviation, total time, CV value, maximum value and minimum value in the specific view point of R-R interval variation. The pattern of R-R interval change after resting, voluntary standing and deep breathing can be analysed in normal subjects and diabetics with autonomic nervous dysfunction. The amplitude of the R-R interval variation showed sensitive pattern for normal subjects at resting, standing and deep breathing. On the contrary, the periodicities of amplitude for abnormal subjects with autonomic nervous dysfunction showed dull pattern. It was suggested that R-R interval analyzer is a good detection method for dysfunction of autonomic nervous system.

  • PDF